CAESAR II Stress Analysis Report

This document contains a stress summary report from a piping analysis software for a job called "BR BEND". It lists 3 load cases that were analyzed and provides the results of the stress checks for 2 of the load cases. Load case 2 passed with the highest stress being 7.3% of the allowable at node 80. Load case 3 resulted in stresses at 72% of the allowable at node 40, indicating the stress check was passed for both load cases analyzed.

Uploaded by

Agus Supriadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views3 pages

CAESAR II Stress Analysis Report

This document contains a stress summary report from a piping analysis software for a job called "BR BEND". It lists 3 load cases that were analyzed and provides the results of the stress checks for 2 of the load cases. Load case 2 passed with the highest stress being 7.3% of the allowable at node 80. Load case 3 resulted in stresses at 72% of the allowable at node 40, indicating the stress check was passed for both load cases analyzed.

Uploaded by

Agus Supriadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

1

CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: NOV 7, 2018 Time: 15:19
Job:: BR BEND
Licensed To:: SPLM: Edit company name in <system>\[Link]

Table of Contents
LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS...................................................................................2
Stress Summary : Multiple................................................................................................................................ 3
2
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: NOV 7, 2018 Time: 15:19
Job:: BR BEND
Licensed To:: SPLM: Edit company name in <system>\[Link]

LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS

1 (OPE) W+D1+T1
2 (SUS) W
3 (EXP) L3=L1-L2
3
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: NOV 7, 2018 Time: 15:19
Job:: BR BEND
Licensed To:: SPLM: Edit company name in <system>\[Link]

STRESS SUMMARY REPORT: Highest Stresses Mini Statement


Various Load Cases

LOAD CASE DEFINITION KEY

CASE 2 (SUS) W
CASE 3 (EXP) L3=L1-L2

Piping Code: B31.3 = B31.3 -2012, Jan 10, 2013

CODE STRESS CHECK PASSED : LOADCASE 2 (SUS) W

Highest Stresses: ( KPa ) LOADCASE 2 (SUS) W


Ratio (%): 7.3 @Node 80
Code Stress: 10101.7 Allowable Stress: 137895.1
Axial Stress: 0.0 @Node 15
Bending Stress: 10101.7 @Node 80
Torsion Stress: 0.0 @Node 15
Hoop Stress: 0.0 @Node 15
Max Stress Intensity: 10101.7 @Node 80

CODE STRESS CHECK PASSED : LOADCASE 3 (EXP) L3=L1-L2

Highest Stresses: ( KPa ) LOADCASE 3 (EXP) L3=L1-L2


Ratio (%): 72.0 @Node 40
Code Stress: 242354.0 Allowable Stress: 336758.6
Axial Stress: 0.0 @Node 15
Bending Stress: 242354.0 @Node 40
Torsion Stress: 0.0 @Node 15
Hoop Stress: 0.0 @Node 15
Max Stress Intensity: 242354.0 @Node 40