rigelmedical.
com
PatSim 200
A cost effective, easy to use
Patient Simulator
The PatSim 200 from Rigel was Why buy the PatSim 200? Key Features:
designed to make every patient
> The PatSim 200 saves and recall 5 > Simple, fast navigation
simulation quicker.
of your most used simulations at the
> High contrast and low luminance
Unlike other Patient Simulators, the touch of just 3 buttons
colour display
PatSim uses a home and recall function
> An instant low-cost replacement for
to easily move between tests and store > Recall most used simulations
old patient simulators - the PatSim
your most used sequences, no more > Foetal / maternal monitoring
200 is compatible with legacy IBP and
clicking and scrolling through ‘tree style’
temperature cables. > Over 40 selectable arrythmias
hierarchy to perform each test.
> Rechargeable Li-Ion battery offering 8
hours of operation between charging
Passionate about patient safety.
T: +44 (0) 191 587 8730 E:
[email protected]See the PatSim 200 for yourself, request your FREE live
online demonstration today at rigelmedical.com/patsim200
rigelmedical.com
What’s in the box? Technical Specification:
> Quick start guide General ECG
Simulation Full 12 lead ECG with independent
> Universal USB power supply
outputs for each signal lead
> 10 x applied part adaptors Lead I 70%
Lead II 100%
> Calibration certificate
Lead III 30%
> PatSim 200 Simulator Lead V1 24%
Lead V2 48%
> PatSim 200 carry case
Lead V3 100%
Optional Accessories: Lead V4 120%
Lead V5 112%
> Replacement battery (404A954) Lead V6 80%
> Temperature cable - unterminated ECG Normal Sinus Rhythm
(404A955) Simulation Full 12 lead ECG with independent
> IBP cable - unterminated (404A956) outputs for each signal lead
Heart Rate 18 selectable values 30-300 bpm
> Replacement carry case (404A950) Accuracy ±1BPM or 1%
> Applied part adaptors (404A951) Amplitude (lead II) 0.05 mV to 0.45 mV (0.05 mV steps)
0.5 mV to 5.5 mV (0.5 mV steps)
> Universal USB power supply Amplitude Accuracy ± 2%
(404A952) ST Segments 18 selectable values, 8 elevated &
8 depressed
Neonatal Mode ECG R wave width is reduced
to 40ms
Arrhythmia Waveforms (Atrial)
Amplitude (lead II) 0.05 mV to 0.45 mV (0.05 mV steps)
0.5 mV to 5.5 mV (0.5 mV steps)
Amplitude Accuracy ± 2%
Ventricular Waveforms Asystole
Bigeminy
Trigeminy
Ventricular Fibrillation (coarse)
Ventricular Fibrillation (fine)
Ventricular Tachycardia
Supraventricular Waveforms Atrial Fibrillation coarse
Atrial Fibrillation fine
Atrial Flutter
Atrial Tachycardia
Missing beat
Nodal rhythm
Paroxysmal Atrial Tachycardia
Sinus Arrhythmia
Supraventricular Tachycardia
Passionate about patient safety.
T: +44 (0) 191 587 8730 E:
[email protected]See the PatSim 200 for yourself, request your FREE live
online demonstration today at rigelmedical.com/patsim200
rigelmedical.com
Service and Warranty Technical Specification (Continued):
The PatSim 200 comes with a free Arrhythmia Waveforms (Atrial) (Continued)
upgraded 5-year warranty, subject to Atrial Conduction Waveforms First Degree AV Block
terms and conditions, available at Left Bundle Branch Block
Right Bundle Branch Block
rigelmedical.com/register Second Degree AV Block - Mobitz I
Second Degree AV Block - Mobitz II
Third Degree AV Block
Premature Waveforms Premature Atrial Contraction
Premature Nodal Contraction
Premature Left Ventricle
Contraction
Premature Left Ventricle
Contraction - early
Premature Right Ventricle
Contraction - R on T
Premature Ventricular Contraction -
6 / min
Premature Ventricular Contraction -
12 / min
Premature Ventricular Contraction -
24 / min
Premature Ventricular Contraction -
frequent multifocal
Performance Waveforms
Square Waves 2 Hz, 0.125 Hz
Triangle Wave 2 Hz
Pulse 60bpm or 240bpm
Sine Waves 0.05, 0.5, 1, 10, 25, 30, 40, 50, 60,
and 100 Hz
R-Wave Detector Test 60 BPM haver-triangle wave with
selectable width and amplitude
Haver-triangle Width 12 selectable values between 8
and 200 ms
Performance amplitude 0.5 to 5.0 mV in 0.5 mV steps
Pacer Waveforms
Simulated Rhythms Asynchronous at 75 bpm
Demand with frequent sinus beat
Demand with occasional sinus
beat
A-V sequential
Non-capture
Non-function
Pulse Amplitude 1.0, 2.0, 5.0, 10.0 mV
Accuracy ±10%
Width 5 selectable values 0.1-2.0 ms
Accuracy ± 5%
Passionate about patient safety.
T: +44 (0) 191 587 8730 E:
[email protected]See the PatSim 200 for yourself, request your FREE live
online demonstration today at rigelmedical.com/patsim200
rigelmedical.com
Technical Specification (Continued):
R Wave Detection
Heart Rate 6 selectable values 30-250 BPM
Amplitude 0.05 mV to 0.50 mV (0.05 mV steps)
R wave width 13 selectable values 8-200ms
Respiration Simulation
Rates 0, 5, 10, 15, 30, 40, 60, 80, 120, 180
brpm
Resistance Variations 0.2, 0.5, 1.0, 3.0 Ω
Accuracy ±10%
Base resistances 500, 1000, 1500 and 2000 Ω
Accuracy ±5%
Lead selection 1 (LA), 2(LL) user selectable
Apnoea Simulation Manual on/off
Temperature Simulation
Simulation YSI 400 / 700A / 700B Static
Temperature unit °C or °F, user selectable
Range pre-set 4 values at 0.0, 24.0, 37.0,
and 40.0°C
pre-set 4 values at 32.0, 75.2, 98.6,
104.0°F
Accuracy ± 0.1 °C / °F
Connector mini-DIN style
Invasive Blood Pressure Simulation
Channels 2 channels
Static Pressure -10, 5,0,20,40,50,60,80,100,150,160,
200,240,320, 400mmHg
Dynamic Simulation Arterial [ART] 120/80
Radial Artery [RA] 120/80
Left Ventricle [LV] 120/00
Right Ventricle [RV] 25/00
Right Atrium (central venous)
[CVP] 15/10
Pulmonary Artery [PA] 25/10
Pulmonary Artery Wedge [PAW]
10/2
Left Atrium [LA] 14/4
Invasive Blood Pressure Simulation (Continued)
Auto sequence (C1 only) Cycle through simulations with 15
second step duration:
Arterial [ART] 120/80
Radial Artery [RA] 120/80
Left Ventricle [LV] 120/00
Right Ventricle [RV] 25/00
Pulmonary Artery Wedge
[PAW] 10/2
Passionate about patient safety.
T: +44 (0) 191 587 8730 E:
[email protected]See the PatSim 200 for yourself, request your FREE live
online demonstration today at rigelmedical.com/patsim200
rigelmedical.com
Technical Specification (Continued):
Invasive Blood Pressure Simulation (Continued)
[PAW] 10/2
Pulmonary Artery [PA] 25/10
Right Atrium (central venous)
[CVP] 15/10
Accuracy ± 1mmHg
Excitation voltage 2V to 16V
Impedance 350Ω Nominal
Simulated sensitivity 5µV/V/mmHg or 40µV/V/mmHg
(user selectable)
Connector mini-DIN style
General Specification:
Mains power/Battery info 3.7V 3900mAh 14.4WH Li-Ion
battery
5V 1A USB micro-B power supply
100-240V ~ 50/60Hz 0.18A max.
Charge time (new battery) Up to 6 hours
Battery life Up to 8 hours (depending on
simulation and screen brightness)
Weight 0.70 Kg / 1.5 lbs
Dimensions 180 x 150 x 55 mm, 7.1 x 5.9
x 2.2 inch
Serviceability
Warranty: 5 years
[terms and conditions apply]
Calibration: 1 year
Environmental
Operating conditions 10 - 40°C (50 - 104°F) 0-90%
RH – NC
Storage environment -15 - 60°C (5 - 140°F) 0-90%
RH – NC
Environmental protection IP40
Impact Rating IK08
Electrical Interfaces
ECG (& respiration) 10 x 4 mm sockets
BP 1 – 2 6 pin mini DIN
Temperature 8 pin mini-DIN
USB Port micro
Rev 3
Passionate about patient safety.
T: +44 (0) 191 587 8730 E:
[email protected]See the PatSim 200 for yourself, request your FREE live
online demonstration today at rigelmedical.com/patsim200