0% found this document useful (0 votes)
59 views2 pages

Datasheet 20 36kW en

The document provides information about CPS SCA20/25/30/36kW three phase grid-tied PV inverters. It details the specifications, features, efficiency curve, protection functions, dimensions, and standards of the inverters.

Uploaded by

Usman Amjad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views2 pages

Datasheet 20 36kW en

The document provides information about CPS SCA20/25/30/36kW three phase grid-tied PV inverters. It details the specifications, features, efficiency curve, protection functions, dimensions, and standards of the inverters.

Uploaded by

Usman Amjad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Inverter-Asia/Europe

20/25/30/36kW Three Phase Grid-tied PV Inverters

NEW
GENERATION

CPS SCA20/25K TL-DO and SCA30/36K TL-DO grid-tied PV inver ters are
tranformerless, three phase products. The maximum input voltage is 1000V which
makes the configuration more flexible. Patented 3-level control algorithm and
thermal design provide 98.6% maximum efficiency and 98.1% Euro efficiency. This
type three phase string inverters are designed with the DC switch integrated. And
provide an option for fuse which designed in the wiring box. Integrated PV input
string fault detection circuit and PV input arcing fault detection circuit to ensure
the safty.

Efficiency Curve
Asia / Europe

CPS SCA30KTL-DO @400Vac

0.98

0.96
Efficiency(%)

DC INPUT VOLTAGE
480
0.94
630
CPS SCA20KTL-DO CPS SCA30KTL-DO
790
0.92 CPS SCA25KTL-DO CPS SCA36KTL-DO

0.9
0 5000 10000 15000 20000 25000 30000
Output Power(W) Broad Adaptability
Low voltage ride through, and provide reactive power to
High Efficiency support the grid
IP65, outdoor application
Maximum efficiency of 98.6%, Euro efficiency of 98.1%
Active power derating and Reactive power adjustable
3-level technology and enhanced control mechanism to
achieve high efficiency over wide load range Separate wiring box design

2 MPP trackers to achieve higher system efficiency BDEW compatible

Transformerless design 1000V maximum input voltage enable flexible configuration


Broad MPPT range enable flexible PV string configuration
Suitable for multi-inverter parallel application

High Reliability Dimensions


Comprehensive protection functions
Enhanced DSP system
Integrated PV input string fault detection
Integrated PV input arcing fault detection and interruption circuit
Advanced thermal design, with variable speed fans
Anti-Islanding protection
Ground-fault detection and interruption circuit
Optional DC SPD
Electrolyte-free design” for improved long-term reliability
5 years standard warranty, optional extension up to 20 years

16
Inverter-Asia/Europe

Model Name CPS SCA20KTL-DO CPS SCA25KTL-DO CPS SCA30KTL-DO CPS SCA36KTL-DO-480
DC Input
Nominal DC Input Power 21kW 26kW 31kW 37kW
Max. DC Input Power for each 12kW 14kW 16kW 19kW
Max. DC Input Voltage 1000Vdc 1000Vdc 1000Vdc 1000Vdc
Operating DC Input Voltage Range 300-900Vdc
Start-up DC Input Voltage / Power 330V/300W
Nominal DC Input Voltage 635Vdc 710Vdc
Number of MPP Trackers 2
MPPT Voltage Range 400-800Vdc 480-800Vdc 540-800Vdc
Max. Input Current 2x27A 2x32A 2x32A 2x34A
Number of DC Inputs 4 strings x 2
DC Disconnection Type Integrated DC switch
AC Output
Rated AC Output Power 20kW 25kW 30kW 36kW

Asia / Europe
Max. AC Output Power 20kW 25kW 30kW 36kW
Rated Output Voltage 230/400Vac 277/480Vac
Output Voltage Range* 320-460Vac 422-528Vac
Grid Connection Type 3Φ/N/PE 3Φ/PE
Max AC Output Current 32A 40A 43.3A 43.3A
Rated Output Frequency 50Hz/60Hz
Output Frequency Range* 47-53Hz/57-63Hz
Power Factor >0.99 (±0.8 adjustable)
Current THD <3%
AC Inrush Current 99A Peak/203us 149A Peak/211us
Maximum Output Fault Current L-N/PE:100A Peak@320ms;56.6A RMS@20ms;
System
Topology Transformerless
Max. Efficiency 98.4% 98.6%
Euro Efficiency 98.0% 98.1%
Stand-by / Night Consumption <20W/<2W
Protective Class I
Overvoltage Category PV(II), Mains(III)
Environment
Protection Degree IP65
Cooling Variable speed cooling fans
Operating Temperature Range - 25°C to +60°C (derating from +45°C)
Operating Humidity 0-100%, non-condensing
Operating Altitude 4000m (derating from 2000m)
Display and Communication
Display LCD+LED
Communication Standard: RS485, USB, Mulit-function Relay Option: Ethernet, Zigbee
Mechanical Data
Dimensions (WxHxD) (mm) 600x1000x230
Weight (kg) 50 (Inverter)+5 (Wiring Box)
Safety
LVD: 2006/95/EC EMC: 2004/108/EC, IEC/EN 62109-1: 2010,
Safety and EMC Standard
IEC/EN 62109-2: 2011; IEC/EN61000-6-2: 2005, IEC/EN61000-6-3: 2007
Grid Standard BDEW; VDE AR-N-4105/VDE 0126-1-1/A1;CEI 0-21; G83/1/1; G59/2; C10/11; NB/T32004;
* The "Output Voltage Range" and "Output Frequency Range" may differ according to specific grid codes.