Type L6E Load Cell
Short Description
• Aluminium-alloy IP65 single point load cell Test certificate no. TC7838 Revision 1
• Colourless anodized C of C no R60/2000-NL1-15.08
• Suitable for pricing scales, bench scales, etc.
• Maximum platform size: 400 x 400 mm Certificate no. 11-062
Available Models
Capacity Accuracy Full Article Description
30kg C3 (excluded from OIML) L6E-C3-30kg-2B
50kg C3/C4/C5 L6E-C3/C4/C5-50kg-2B
60kg C3/C4/C5 L6E-C3/C4/C5-60kg-2B
80kg C3/C4/C5 L6E-C3/C4/C5-80kg-2B
100kg C3/C4/C5 L6E-C3/C4/C5-100kg-2B
150kg C3/C4/C5 L6E-C3/C4/C5-150kg-2B
200kg C3/C4/C5 L6E-C3/C4/C5-200kg-2B
300kg C3/C4/C5 L6E-C3/C4/C5-300kg-2B
500kg C3/C4/C5 L6E-C3/C4/C5-500kg-2B
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.08 L6E Rev12 info@[Link]
Page 1/3 [Link]
Type L6E Load Cell
Technical Specifications L6E
Accuracy Class C3 OIML R60 C3
OIML R60 C4 OIML R60 C5
Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) kg 30 50, 60, 80, 100, 150, 200, 300, 500
Max. Number of Load Cell Intervals nLC 3000 4000 5000
Ratio of min. LC Verification Interval Y = Emax / vmin 10000 15000 20000
Combined Error %FS ≤± 0.0230 ≤± 0.0175 ≤± 0.014
Creep Error (30 minutes) %FS ≤± 0.0167 ≤± 0.0125 ≤± 0.010
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.0200 ≤± 0.0120 ≤± 0.009
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.0175 ≤± 0.0131 ≤± 0.010
Zero Balance %FS ≤ ± 2.0
Safe Overload %FS 150
Ultimate Overload %FS 200
Maximum Deflection mm 30kg – 150kg: 0.6 ~ 0.96 200kg – 500kg: 0.9 ~ 1.3
Eccentric Loading Error %LD/cm ≤ 0.002
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 406 ± 6
Output Resistance Ω 350 ± 3
Insulation Resistance (50V) MΩ ≥5000
Compensated Temperature °C -10 ~ + 40
Operating Temperature °C -35 ~ +65
Storage Temperature °C -40 ~ +70
Load Cell Weight kg ~0.45
Element Material Aluminium
Ingress Protection (acc. to EN 60529) IP65
Recommended Torque on Fixation Bolts Nm M6: 20
Wiring
Features:
Cable type: Shielded, 4 conductor cable , conductor AWG 24
Cable diameter: Ø 5.3mm
Cable length: 2.0m
Cable jacket: PVC
Shield not connected to element
4-Wire Connection Diagram
Input(+) Red
Output(-) White
Input (-) Black
Output(+) Green
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.08 L6E Rev12 info@[Link]
Page 2/3 [Link]
Type L6E Load Cell
Dimensions in mm
Top View
Front View
Side View Isometric View
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2022.08 L6E Rev12 info@[Link]
Page 3/3 [Link]