0% found this document useful (0 votes)
531 views11 pages

RO1000lph 230829 162630

The document provides a techno-commercial offer from Hi-Tech Sweet Water Technologies Pvt Ltd for a 1000 LPH reverse osmosis water treatment system. Key details include: - The company offers domestic and commercial RO systems from 8-100,000 LPH - The proposed 1000 LPH system would operate 8-9 hours daily with 0.5-1 hours for backwashing and produce 1000 LPH of treated water from 2000 LPH of raw feed water. - The system includes pumps, filters, anti-scaling dosing, 5 micron sediment filters, high pressure pump, RO modules, and storage tank.

Uploaded by

abbasranala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
531 views11 pages

RO1000lph 230829 162630

The document provides a techno-commercial offer from Hi-Tech Sweet Water Technologies Pvt Ltd for a 1000 LPH reverse osmosis water treatment system. Key details include: - The company offers domestic and commercial RO systems from 8-100,000 LPH - The proposed 1000 LPH system would operate 8-9 hours daily with 0.5-1 hours for backwashing and produce 1000 LPH of treated water from 2000 LPH of raw feed water. - The system includes pumps, filters, anti-scaling dosing, 5 micron sediment filters, high pressure pump, RO modules, and storage tank.

Uploaded by

abbasranala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Hi-Tech Sweet Water

Technologies Pvt. Ltd.


Techno-Commercial Offer
August 25, 2023
HI-TECH SWEET WATER TECHNOLOGIES PRIVATE LIMITED
An ISO 9001:2008 CERTIFIED COMPANY

Head Office: 4, Gopal Nagar, Nandida Char Rasta, BARDOLI, Dist: Surat (INDIA). Phone:
(02622) 222755, 224726, 325930, Fax – (02622) 227315
Marketing Office: 229-30 Turning Point complex, Ghod Dod Road, Surat.
Phone: (0261) 2236426, 2233079, 3252432, Fax - (0261) 2234907
HELPLINE NO: 98980 47820, 98980 22557 • NATIONAL TOLL FREE NO: - 1800 2331 365
Email: [email protected] Site: www.hitechro.net

To, Date: - August 25, 2023

Subject: Techno-Commercial offer for RO-1000 LPH

Dear Sir/Madam,
Greetings from Hi-Tech Sweet Water Technologies.
At the outset I profusely thank you for your time and attention. We at Hi-tech Sweet Water
Technologies solicit your precious time to introduce ourselves and our outstanding line of
domestic as well as commercial reverse osmosis based water treatment products. We are
committed to unique customer experience, and delivering the highest standards of reliability
and quality with all of our products.

As a part of the complete customer care relationship, we provide intuitive, comprehensive


onsite service for our system after warranty also. True, our products are recognized for
reliability, but imagine being able to view all details of the products about our system, - all
with the click of the mouse. It's all found at www.hitechro.net
As discussed please find attached our best techno-commercial offer. We hope to cater to all
your future water treatment requirements.
Thanking your anticipation,
Truly yours,

For, Hi-Tech Sweet Water Technologies Pvt. Ltd.


Kamlesh patel
9974088718

Authorized Signatory
A Brief Introduction about our Company
Hi-Tech Sweet Water Technologies Pvt Ltd - is the first and leading manufacturer of all kinds of
Water Treatment Systems in India. Hi-tech is India based more than two decades old company,
having its PAN India with 45 branch offices & overseas network in U.S.A., U.A.E. Thailand & China
also. It is an ISO: 9001-2008, 14001-2004, 18001-2007 & CE certified company manufacturing &
marketing all kinds of water treatment plants, its all critical spares & components with complete
customer care.

Hi-Tech manufacture, market & sell RO, UV, UF water purifiers for domestic, Industrial,
commercial segments with specialized & customized total water solution on turnkey basis.
It also deals in Domestic / Industrial Softeners, DM plants, CETP, STP, Remote Control
based plant Operating & Monitoring systems and many more.

Hi-Tech is the first and only manufacturing company in India to produce R.O. Membranes
for complete range of domestic and industrial segments. Our best quality RO Membranes
had been recognized and awarded consequently for two years by Water Digest & UNESCO
for years 2014-15 & 2015 – 16. Hi-Tech is Awarded for Categories like “Best Company to
give Rural Drinking Water Solution” by Water Digest Water Awards & UNESCO also. And
Hi-Tech is also Awarded as "The Most Promising Brand For Water Treatment In India" for
2015 Leader's Award by 24 MRC

Hi-Tech is the first company to be “I.S.O.: 9001:2008” certified for its Quality Management
System and Product Design, Manufacturing, Installation and After Sales Service of
Commercial & Industrial R.O. water treatment plants and Domestic R.O. water purifiers by
KVQA, And the present Certification is for ISO 9001:2008. Company is also Certified for ISO
14001:2004 & 18001:2007. All the Hi-Tech Brand Products are certified by C.E. for Product
Conformities. We are certified by N.S.I.C.

Hi- Tech deals with Commercial, Domestic and Industrial RO Systems. It also manufactures
packaged RO systems for ground, bore well, well, river and tap water applications in
standard capacities of portable water production. The capacities range anywhere from 8
Liter/hour to 1,00,000 Liter/hour and we are produce single, double, and triple tube water
filters which come with and without UV and UF attachments as well as softeners and
water vending machines in various capacities. As per the requirement of our customer, Hi-
Tech can customize design, manufacture and install its systems to meet specific
requirements. We have supplied more than 15000 industrial plants for various needs such
as Turnkey based ISI Certified bottled water manufacturing projects, soft drink
manufacturing projects, hospitals, villages, schools, colleges, industries, corporate offices,
etc. and more than 2,00,000 domestic RO plants till date and we strive to maintain state of
the art technology and equipment to assist our engineers in the selection and designing of
the most effective RO systems according to the type of raw water available to each of our
clients.

Please visit our website www.hitechro.net


BASIS OF DESIGN AND TREATMENT SCHEME
PLANT INTRODUCTION:
The proposed Water Treatment scheme is designed to produce product water based on
Reverse Osmosis Technology.

1. The proposed water treatment system can even work continuously for 8-9 Hours per
day leaving aside 0.5 – 1 Hours for the recommended Backwashing of the Filtration
2. The proposed water treatment system based on RO Technology is designed with the
Recovery level of 60-65%.

RAW WATER ANALYSIS (ASSUMED):


We have designed the proposed Water Treatment System based on following Water
Analysis,

Sr. No. Parameter Analysis Value.


1 Total Dissolved Solids 2000 ppm (Max.)

2 Turbidity <1 NTU

3 SDI <5

4 Heavy metals NIL

5 Organics And Bacteria NIL

6 Oil And Grease NIL

7 Residual Chlorine NIL

8 Temperature ( °C ) < 40.

9 Color Color Less

10 Odor Odor Less

11 BOD & COD NIL

12 Silica < 1 mg/lit

END WATER QUALITY:


TDS < 50 ppm.
PH 7.0 +/ - 0.2

Turbidity Nil or < 1 NTU


Color Nil.

RO PLANT OPERATING CONDITION:


Sr. No. Parameter Value.
1 Feed Flow Rate. 2000 LPH

2 Product Flow Rate 1000 LPH

3 Recovery. 40-50 %

TREATMENT SCHEME:
Sr. No. Description
1 Raw Water Pump

2 Sand Media vessel + carbon media vessel

3 Anti Scaling Dosing System

4 20 Micron Sediment Pre Filter

5 5 Micron Sediment Pre Filter

6 High Pressure Pump

7 RO Module

8 RO Product water storage Tank (By Client)

The End Water quality shall be achieved subjected to:

1. Feed quality is same as specified in your enquiry. In case of any change in the quality of
raw water, the same may have an implication on the Operating parameters and End-
water quality of the system.

2. Feed limiting condition mentioned in our offer is strictly maintained.

3. Operation of Water treatment plant is strictly followed in totality as per our operating
manual & instructions.
TECHNICAL SPECIFICATION 1,000 lph
1 Skid
MOC SS
No. 1
Make HI-TECH
Capacity RO 1000 Ltr.
Type Rectangle
2 Feed Pump
Type Self Priming
No. 1
Make Crompton/lubi/LEO
Capacity 2000 LPH
Pressure 3 KG/ CM2

3 Sand Filter
Type Vertical
Diameter 13 Inch
Height 54 Inch
MOC FRP
Type of Operation Manual
Back wash Time 10-15 minutes
Size of multi port valve 1”
3 Carbon Filter
Type Vertical
Diameter 13 Inch
Height 54 Inch
MOC FRP
Type of Operation Manual
Back wash Time 10-15 minutes
Size of multi port valve 1”
4 Anti Scaling dosing system
Pump 1 Set
Make Hi-tech
Quantity 1
Type Electronic Diaphragm Type
Capacity 0 to 4 LHP
5 Cartridge Filter Housing
Flow rate 4 M3/hr.
MOC FRP
Length of Housing 20”
Dia. Of Housing 4”
No. of Cartridge Housing 2 Nos.
6 Micron Cartridge Filter
Flow rate 1 M3/hr.
MOC PP
Length of Cartridge 20”
Dia. Of cartridge 4”
No. of Cartridge 2 Nos.
Rating 5 Micron
Make Hitech
7 Pressure Pump
Type Vertical centrifugal multi stage
No. 1
Make LUBI/CRI/LEO
Power consumption 2 HP
Flow 4 M3
Pressure 10-12 kg
8 Pressure Tube
Item RO module consisting of membrane Housing With RO
membrane mounted on skid.
MOC FRP
Dia. 4”
Length 42”
Qty. 4 Nos.
9 Membrane
Type TFC POLYAMIDE
Size 4” dia. x 40”
Qty. 4 Nos.
Make HITECH
Rating 0.0001 Micron.
INSTRUMENTATION:
A Digital Conductivity OR TDS Meter
Quantity 1 Nos.
Maximum Temperature 40 Degree Centigrade
Location RO Permeate.
B Flow Indicators
Quantity 2 Nos.
Type Float Type Panel Mounted.
Maximum Op. Temp. 40 Degree Centigrade.
Measuring Points RO Module Feed & Product Flow
C Pressure Gauges
Quantity 2 Nos.
Range 0-4 & 0-35 Kg / Cm2.
Location 1) RO Module Inlet.
2) RO Module Reject Flow
D High Pressure Switch And Low Pressure Switch
Quantity 1+1 Nos.
Location Before & After High Pressure Pump.
E Pressure Control Valve
Location Reject Water Line
Nos. 1 Nos.
F Auto Flushing switch with Solenoid Valve.
G MICRO BASE PENAL

PIPE LINE
1. CPVC pipe line

SKID
1. SS box pipe frame.

Price RO -1000 liters per hour:

Rs. 1, 60,000

SCHEDULE OF EXCLUSIONS AND


TERMINATION
SCHEDULE OF EXCLUSION:

1. All Civil Works such as plant foundation of the equipments, mass concreting etc.
2. Supply of power to Motors, regeneration chemicals for trial run and commissioning.
3. Laboratory testing facility, Instruments and reagents.
4. Lubricants, oil and Greece as and when required.
5. Raw water storage tank.
6. All equipments, works and services not specifically mentioned in our proposal.
7. Storage and site security.

CLIENT TO PROVIDE:
No Items Scope
1 Control & Power supply Three phase for high pressure pump and all instrumentation

2 Service Water As per the offered capacity of RO for its inlet of RWP

3 Lab. Testing Facility For analysis of client’s feed water.

4 Labor As and when required

5 Chemicals Special Anti-Scaling Chemical

Terms & Conditions:


1. Tax: 18% GST Extra
2. Installation: client scope
3. Delivery: 2 to 3 weeks after confirmation of purchase order along with
advance.
4. Freight Charges: Extra as on actual
5. Insurance is optional at extra charges
6. Packing charges are separate at per requirement

For, Hi-Tech Sweet Water Technologies Pvt. Ltd.

Authorized Signatory

SITE INSPECTION REPORT


Dt. & Time_________________

Name of Party/Company __________________________________________


Address __________________________________________
__________________________________________
Phone number __________________________________________
Authorized Contact Person __________________________________________
Site of Inspection __________________________________________
__________________________________________
Site In charge __________________________________________
Phone number __________________________________________

Parameters Checked:

1. Type of water Bore well/Tube well/River/Canal/Pond/Corporation.


2. Row water TDS ___________________PPM.
3. Chemical analysis/Micro. Bio. Analysis available or Not________
4. Location_____________________.
5. Covered Room for Plant _________________________ sq.ft/
6. Room Size W_________ft. X W_________ft. X H_________ ft.
7. Power Supply available single phase/ Three phase.
8. Available H.P _______________.
9. Capacity of overhead tank ___________lts.
10. Type of overhead tank _______________lts.
11. Appx. Height of overhead tank __________________.
12. Appx. Height of overhead tank from ground level/plant__________ft.
13. Type of pipeline from overhead tank to plant____________________.
14. Diameter of pipeline______________________________.
15. Electric point and water point provision in the plant room______________.
16. Provision for waste water outlet__________________________.
17. Final water storage tank req.______________________.lts
18. Type of storage tank req.______________________________.
19. Application of final RO water___________________________.
20. No. of people in the premises_________________________.
21. Type of distribution of final RO water _________________________.
22. Capacity of model of the RO plant to be installed_________________LPH.

Note: Data for Items in bold has to be provided by clients

_______________ ____________ ____________ ___________


Name Name Name Name

(Autho. Contact person) (Site Incharge) (Company Head) (Company eng)

RAW WATER ANALYSIS REPORT


1. Raw Water Source: _____________ (Surface Water, Bore Well Water, Sea Water)

Sr. no Particulars Unit Design Value

1 pH -----

2 TSS ppm
3 Sulphate ppm

4 Total Dissolved Solids ppm

5 Fluoride ppm

6 Chloride ppm

7 Calcium ppm

8 Magnesium ppm

9 Silica ppm

10 BOD ppm

11 COD ppm

12 Total hardness ppm

13 Oil & Grease ppm

14 Free Chlorine ppm

15 Turbidity NTU

Note: Raw water Analysis report has to be provided by client