0% found this document useful (0 votes)
153 views2 pages

Medium Voltage Transformer Specs

This document provides specifications for the Medium Voltage Indoor Voltage Transformer Model 3PT3-60. It is a 60 Hz transformer with a rated primary voltage ranging from 2400 to 4800 volts and a standard secondary voltage of 120 volts. The transformer has an accuracy class of 0.3% and is rated for a maximum system voltage of 5.6kV. It has a thermal rating of 700VA at 30°C ambient or 450VA at 55°C ambient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
153 views2 pages

Medium Voltage Transformer Specs

This document provides specifications for the Medium Voltage Indoor Voltage Transformer Model 3PT3-60. It is a 60 Hz transformer with a rated primary voltage ranging from 2400 to 4800 volts and a standard secondary voltage of 120 volts. The transformer has an accuracy class of 0.3% and is rated for a maximum system voltage of 5.6kV. It has a thermal rating of 700VA at 30°C ambient or 450VA at 55°C ambient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

M

Meed
diiu
umm V
Voollt
taag
gee

I
Innd
dooo
orr V
Voollt
taag
gee T
Trra
anns
sffo
orrm
meer
r

Model 3PT3-60
REGULATORY AGENCY APPROVALS

E145172 LR89403

Manufactured to meet the requirements of ANSI/IEEE C57.13.

ACCURACY CLASS:
0.3 WX, 0.6M,1.2Y at 100% rated voltage

with 120V based ANSI burden.

FREQUENCY:

60 Hz.

THERMAL RATING:
o

700 VA total 350 VA per phase, at 30 C. amb.

450 VA total, 225 VA per phase, at 55 C. amb.

STANDARD SECONDARY VOLTAGE:

120 volts.

MAXIMUM SYSTEM VOLTAGE:

5.6kV, BIL 60kV.

Primary terminals are No.10-32 brass screws

with one flatwasher and lockwasher.

Approximate weight 38 lbs.

CATALOG NUMBER RATED SUGGESTED


CATALOG
FUSES CLIPS PRIMARY RATIO FUSE
GROUP NUMBER FUSES
ONLY VOLTAGE RATING**

1 3PT3-60-242FFF 3PT3-60-242CCC 2400 20:1 1.0E

2 *3PT3-60-332FFF * 3PT3-60-332CCC 3300 30:1 1.0E

2 3PT3-60-422FFF 3PT3-60-422CCC 4200 35:1 0.5E

2 3PT3-60-482FFF 3PT3-60-482CCC 4800 40:1 0.5E

o o

* RATED 50/60Hz., 03W, 500 VA TOTAL @ 30 C, 350 VA TOTAL @ 55 C.

Medium Voltage 33
M
Mood
deell 3
3PPT
T33-
-660
0

Connection Diagram

** See Page 32, Primary Fuse Rating

Fuse is 0.81” Diameter, 5.62” Long.

• The core and coil assembly is encased in a

plastic enclosure and vacuum encapsulated in

polyurethane resin.

RECOM MENDED MINIMUM SPACINGS

A = Case to Ground = 1.50” minimum.

Recommended spacing are for guidance only. User needs to set

appropriate values to assure performance for high potential test ,

impulse test , high humidity, partial discharge, high altitude, and other

considerations like conf iguration.

USA, Canada, Asia, Latin America Europe, Middle East , Africa

Tel: +1-800-547-8629 Tel: +34-94-485-88-00

Fax: +1-905-201-2455 Fax: +34-94-485-88-45

e-mail: [Link]@[Link] e-mail: [Link]@[Link]

34 Medium Voltage Please refer to our website [Link] for more detailed contact information CS00A40646 Rev.

You might also like