Data Sheet M&EUR619EN

UR619 Series
AthalonTM Return Line Filters

Athalon™ maximum-life filters deliver the highest level of sustained fluid • Keeps fluids the cleanest, longest,
system protection, across all applications, regardless of severity. for the greatest value
Featuring an industry leading BetaX(C)=2000* filter efficiency; the • Provides consistent, reliable,
highest rated filter performance available today. protection of system components
(* per ISO 16889) over the full service life of the filter
element
Notes and Specifications Filter Housing • Rapidly achieves and sustains
required fluid system cleanliness
• Flows to 835 L/min (220 US gpm)
• Delivers maximum filter capacity in
• Pressures to 28 bar (400 psi)
the smallest footprint
• Port Size 2” and 2½”
• Prevents electrostatic discharge
• Rated Fatigue Pressure: from damaging your filter and
0-23 bar (330 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million degrading your fluid
cycles), verified by testing at 0-27 bar (392 psi) for 1 million cycles.
• Filter Element Burst Pressure: Features
10 bard (150 psid) • Patented Ultipleat (laid-over pleat)
• Fluid Compatibility: filter medium pack
Compatible with all petroleum oils and most water glycols, water-oil • Pall Stress-Resistant Technology
emulsions, and synthetic hydraulic and lubrication fluids (SRT) Media
• Temperature Range: • Coreless filter element
Fluorocarbon Seals: configuration
-29 ˚C to 120 ˚C (-20 ˚F to 248 ˚F) • Low clean differential pressure for
60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids low energy operation
• Bypass Valve Setting:
1.7 bard (25 psid) or
4.5 bard (65 psid) UR619 Series
• Indicator Pressure Setting: filter housing

1.1 bard (16 psid) or


3.5 bard (50 psid)
• Materials of Construction: Element Pressure Drop
Head and tube: Aluminium 610 Series Filter Elements – bard/1000 L/min (psid/US gpm)
Cover: Steel/cast iron
Length Code AZ AP AN AS AT
• Filter Element: 20 1.31 (0.072) 0.56 (0.030) 0.43 (0.023) 0.31 (0.017) 0.19 (0.011)
Inorganic fibers impregnated and bonded with epoxy resins. Polymer 40 0.70 (0.038) 0.30 (0.016) 0.23 (0.013) 0.17 (0.009) 0.10 (0.006)
endcaps. Anti-static media design
Multiply actual flow rate times factor in table below to determine
Pressure Drop Information pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other
fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.
Housing pressure drop using fluid with 0.9 S.G. Note: factors are per 1000 L/min and per 1 US gpm.
Housing pressure drop is directly proportional to specific gravity.
Sample ∆P calculation
Flow (L/min)
UR619 Series 40” length housing with F40 ( 2 1/2” ISO 6162) split
225 300 400 500 600 700 800 flange ports using AN grade media. Operating conditions 600 L/min
20 flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ∆P
16 1.1
= ∆P housing + ∆P element
12 0.8 = (0.45 x 1.2/0.9) bard (housing)
-24 and -32 Ports + ((600 x 0.23/1000) x 50/32 x 1.2/0.9) bard (element)
8 0.6 = 0.6 (housing) + 0.29 bard (element)
-40 Ports = 0.89 bard (9.3 psid)
P (bard)
P (psid)

4 0.3

0 0
60 80 100 120 140 160 180 200 220

Flow (US gpm)


Ordering Information
For new installations, select one complete
part number from each section below

Section 1 Housing P/N: UR619 9 Section 2 Element P/N: UE 610


Table A Table 4 Note: Z indicates fluorocarbon seals are standard. Table 5 Table 3
Other options are available; contact Pall.
Note: Pall Athalon filter housings are supplied without filter elements or
warning devices fitted. Never operate the filter unless a filter element is
Table 5: Filter Element Options
fitted and all warning device ports are sealed.
Code ßx(c) ≥2000 based on ISO 16889 CST Rating* * CST: Cyclic
Note: Z indicates fluorocarbon seals are standard. Other options are available; Stabilization Test
AZ 3 07/04/01 to determine filter
contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.
AP 5 11/08/03 rating under stress
conditions, based
Table A AN 7 13/09/04 on SAE ARP4205
Port & Length Options AS 12 15/11/06
Tables 1, 2 and 3 AT 25 16/14/08

CA3220Z
CA3240Z
CC3220Z Section 3 (At least one Differential Pressure Indicator or
‘B’ type blanking plug must be ordered)
CC3240Z
CD3220Z
Differential Pressure Indicator P/N:
CD3240Z
CD4020Z RC Z Z
CD4040Z Table 6 Table 7 Table 8
CF3220Z Note: If no differential pressure indicator Note: Z indicates fluorocarbon
CF3240Z is selected, ‘B’ type blanking plug (P/N seals are standard. Other
HC9000A104Z) must be ordered separately options are available;
CF4020Z
and fitted to replace the plastic shipping plug. contact Pall.
CF4040Z
Table 6: Indicator Options
Table 1: Housing Port Options Code Brass Option indicator
Code Port Style A218M Electrical switch (SPDT) with Hirschmann connector
A SAE J1926 straight thread A218R Electrical switch (SPDT) with Hirschmann connector
C BSP ISO 228 threads with Red and Green LED indicators
D Flange J518C code 61 A219D Visual indicator
F ISO 6162 split flange
Code Stainless Steel indicator
Table 2: Port Size Table 3: Housing Length and Seal Options 778N Visual filter with thermal lockout
Code Port Style Code Length and Seal Material 861C* Electrical switch (SPDT) with Hirschmann connector
32 2” nominal 20Z 20” nominal length, fluorocarbon seals 771B Electrical switch (SPDT) with 3-pin
40 2 ½” nominal 40Z 40” nominal length, fluorocarbon seals
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 7.
Table 4: Bypass Valve and Service Options
Code Bypass Valve and Service Type Table 7: Indicator Pressue Setting Option
A 1.7 bard (25 psid) bypass valve, cover service Code Valve
G 4.5 bard (65 psid) bypass valve, cover service 084 For ‘A’ Valve Option - Housings (1.1 bard - 16 psid)

N No bypass valve 091 For ‘G’ and ‘N’ Valve Options - Housings (3.5 bard - 50 psid)
Other setting options are available; contact Pall.

Seal Kit P/N: UR619SKZ Table 8: Differential Pressure Indicator Material


*Other seal material options are available; Contact Pall.
Code Description
Omit If Brass indicator is chosen in Table 6
SS If Stainless Steel Indicator is chosen in Table 6.
Note: SS indicator is recommended for high pressure cycle
applications with pressure >200 bar (3000 psi)

Other setting options are available; contact Pall.


Dimensional Drawings Length Overall length Element Removal Empty Weight
Code mm (in) Clearance mm (in) kg (lb)
Dimensions in mm (inches)
20 762 (30) 443 (17.5) 26 (58)
40 1270 (50) 951 (37.5) 36 (80)

ELEMENT
REMOVAL DIFFERENTIAL
CLEARANCE PRESSURE INDICATOR
HANDLE -UNSCREW PORT
TO REMOVE COVER
AND LIFT ELEMENT

BLEED PORT FILL PORT


1/8 BSP ISO228 3/8 BSP ISO228
(1/4 SAE J514) (1/2 SAE J514)
195.6 mm
(7.70 in)

181.1 mm
(Ø7.13 in) 127.0 mm
(5.0 in)

OVERALL
LENGTH
203.5 mm
(8.01 in)
176.8 mm
(6.96 in)
MOUNTING
BRACKET 2.3 mm
88.9 mm (0.09 in) BRACKETS CAN BE
(3.50 in) REMOVED UP OR DOWN
10.7 mm
(Ø0.422 in)
TYP
10.7 mm
(0.422 in)
DIFFERNTIAL
PRESSURE
OUTLET INDICATOR 2 x DRAIN PORT
PORT 1/2 BSP ISO228
(1/2 SAE J514)

63.8 mm
‘H’ DIM.
(2.51 in)
INLET

4X .500-13 UNC-2BTHD 101.6 mm


FOR A & D PORT OPTIONS (4.0 in) 197.9 mm
4X M12X1.75-6HTHD (Ø7.79 in)
FOR C&F PORT OPTIONS

101.6 mm
(4.0 in)

109.2 mm The equipment has been assessed


(4.30 in)
in accordance with the guidelines
laid down in The European Pressure
Directive 97/23/EC and has been
classified within Sound Engineering
126.0 mm 111.0 mm Practice S.E.P. Suitable for use with
(4.96 in) (4.37 in)
Group 1 and 2 fluids only. Consult Sales
for other fluid gas group suitability.

25 Harbor Park Drive Visit us on the Web at www.pall.com


Port Washington, NY 11050
+1 516 484 3600 telephone Pall Corporation has offices and plants throughout the world. For Pall representatives in your area, please go to
+1 800 289 7255 toll free US www.pall.com/contact

Portsmouth - UK Because of technological developments related to the products, systems, and/or services described herein, the data
+44 (0)23 9233 8000 telephone and procedures are subject to change without notice. Please consult your Pall representative or visit www.pall.com
to verify that this information remains valid.
+44 (0)23 9233 8811 fax
www.pall.com/contact © Copyright 2018, Pall Corporation. Pall, , and Athalon are trademarks of Pall Corporation.
® Indicates a trademark registered in the USA. Better Lives. Better Planet. and Filtration. Separation. Solution.SM
are service marks of Pall Corporation.

M&EUR619EN Produced in the UK November 2018

You might also like