0% found this document useful (0 votes)
60 views5 pages

ASEbrochure

This document summarizes three products from Stryker - HipMap, HipCheck, and Pivot Guardian - that create an advanced surgical experience for hip arthroscopy. HipMap is a pre-operative planning tool that provides 3D modeling of the hip to assist with clinical decision making. HipCheck is an intra-operative tool that allows surgeons to measure and resect cam lesions to a desired angle. Pivot Guardian is a hip distraction system designed to improve surgical workflow and patient outcomes.

Uploaded by

davidgusmao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views5 pages

ASEbrochure

This document summarizes three products from Stryker - HipMap, HipCheck, and Pivot Guardian - that create an advanced surgical experience for hip arthroscopy. HipMap is a pre-operative planning tool that provides 3D modeling of the hip to assist with clinical decision making. HipCheck is an intra-operative tool that allows surgeons to measure and resect cam lesions to a desired angle. Pivot Guardian is a hip distraction system designed to improve surgical workflow and patient outcomes.

Uploaded by

davidgusmao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

The advanced

surgical experience
HipMap, HipCheck and Pivot Guardian

Establishing the
next frontier in FAI
The future of
hip arthroscopy.
Now.
HipMap, HipCheck, and Pivot Guardian create an
advanced surgical experience for physicians and patients.
This is a platform designed to advance FAI through enhanced
workflow and improved patient-specific results.
HipMap HipCheck
A pre-operative planning tool that delivers a patient-specific, interactive 3D An intra-operative resection planning and execution tool that allows surgeons to
representation of the hip designed to assist with clinical decision making. measure and resect cam lesions to a desired alpha angle.

Plan
HipMap leverages advanced imaging to
deliver a report with cam and pincer
analysis, version/torsion measurements,
indications for potential instability, 3D heat
maps, measurement scales, and other visual
tools.

HipMap utilizes complex analytics to provide


surgeons with an advanced approach to
pre-operative clinical decision making.

Educate
HipMap will help patients understand the
pathology affecting their hip joint and will
contribute to a more robust discussion on
the surgical approach.

Patient-specific cam pathology Improve workflow


Proprietary technology allows surgeons to localize Introduces a visualization tool to the sterile field to
and address cam pathology on a patient-specific augment a surgeon’s cam resection.
basis.
Touchscreen
Advanced and reproducible approach to The touchscreen interface is designed to integrate
femoroplasty into current workflow and put the surgeon in
Case review functionality allows surgeons to view a control.
side-by-side comparison of pre-resection and post-
resection fluoroscopy to verify the resection plan Post-Op communication
was executed. This checklist provides confidence Pre-resection and post-resection comparison images
that the full 3D volume of a cam lesion has been
demonstrate the cam was resected appropriately.
addressed.
Explore the Discover the next
innovative design generation boot
State-of-the-art design and manufacturing focused on improving the patient Designed to mitigate heel slip for improved patient outcomes.2
experience and operating room efficiency.
A A. Boa System
Deliver precise fit and
adjustment to distraction
B system boots, designed to
enhance the comfort and safety
of the patient.
B. Achilles block
Designed to secure the patient’s
ankle during distraction.
C
D
B
A
A. Traction force gauge C. Post-free
The system includes a traction force gauge The Pivot Guardian Distraction System
that estimates the amount of force on the is designed to mitigate post related
patient. complications.
B. Fine and gross traction controls D. Carbon fiber construction
Designed to provide precise control and Radiolucent carbon fiber construction
better range-of-motion. The surgeon can minimizes the amount of metal
easily make adduction, abduction, as well components surrounding the hip,
as extension and flexion hip adjustments. allowing for full anterior and posterior
It also allows for internal and external visualization during surgery, a “true AP
rotation of the hip. radiographic shot”.1
OR turnover
The Pivot Guardian Distraction System is designed to minimize the time and effort required for
transport, setup and takedown.
Sports Medicine
This document is intended solely for the use of healthcare professionals. A surgeon must always rely on his or her own professional clinical Stryker
judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and Sports Medicine
recommends that surgeons be trained in the use of any particular product before using it in surgery. 5670 Greenwood Plaza Blvd, Ste 200
Greenwood Village, CO 80111
The information presented is intended to demonstrate a Stryker product. A surgeon must always refer to the package insert, product label and/
or instructions for use, including the instructions for cleaning and sterilization (if applicable), before using any Stryker product. Products may www.stryker.com
not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please
contact your Stryker representative if you have questions about the availability of Stryker products in your area.

Stryker Corporation or its affiliates own, use, or have applied for the following trademarks or service marks: HipCheck, HipMap, Pivot Guardian
Distraction System, Stryker. All other trademarks are trademarks of their respective owners or holders.

1. Data on file, Stryker, DHD13364, “Hip Distractor, Evaluation of Distracted Space and Imaging”
2. Data on file, Stryker, DHD13315, “Hip Distractor Competitor Boot Heel Slip, Flame Deflection, and Table Top Pad Shear Detachment Force
Benchmarking Report”

Literature Number: 1000903001 Rev A


Copyright © 2019 Stryker

You might also like