SA5000 Flow Sensor Operating Manual

This document provides specifications for the SA5000 Flow sensor model SAD10XDBFRKG/US-100. It has 2 digital outputs, 1 analog output, and can measure flow rates from 0.04-6 m/s with temperatures from -20-90°C and pressures up to 100 bar. It communicates via an IO-Link interface and has configurable outputs for switching signals, frequency, or analog signals.

Uploaded by

Abdul Kurniadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
246 views5 pages

SA5000 Flow Sensor Operating Manual

This document provides specifications for the SA5000 Flow sensor model SAD10XDBFRKG/US-100. It has 2 digital outputs, 1 analog output, and can measure flow rates from 0.04-6 m/s with temperatures from -20-90°C and pressures up to 100 bar. It communicates via an IO-Link interface and has configurable outputs for switching signals, frequency, or analog signals.

Uploaded by

Abdul Kurniadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

SA5000

Flow sensor
SAD10XDBFRKG/US-100

1 LEDs Display unit / Switching status


2 alphanumeric display 4-digit red/green
3 Programming buttons
4 upper part of the housing can be rotated 345°

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Process connection threaded connection M18 x 1,5 Internal thread
Application
System gold-plated contacts
Media water; glycol solutions; air; oils
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
Note on media
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C] -20...90
Pressure rating [bar] 100
Pressure rating [Mpa] 10
MAWP (for applications
[bar] 100
according to CRN)

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SA5000-01 — 26.04.2021 —
SA5000
Flow sensor
SAD10XDBFRKG/US-100

Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching
[V] 2.5
output DC
Permanent current rating of
[mA] 250
switching output DC
Number of analog outputs 1
Analog current output [mA] 4...20; (scalable)
Max. load [Ω] 350
Short-circuit protection yes
Type of short-circuit
yes (non-latching)
protection
Overload protection yes
Frequency of the output [Hz] 0...1000
Measuring/setting range
Probe length L [mm] 45
relative; absolutely liquid; absolutely gaseous;
Operating mode
(absolute: reference measurement recommended)
Note on factory setting Operating mode: relative
Temperature monitoring
Measuring range [°C] -20...90
Resolution [°C] 0.2
Liquid media - absolute operating mode
Setting range [m/s] 0.04...3
Greatest sensitivity [m/s] 0.04...3
Liquid media - relative operating mode
Setting range [m/s] 0.04...6
Greatest sensitivity [m/s] 0.04...3
Gases - operating mode "absolute"
Setting range [m/s] 0...100
Greatest sensitivity [m/s] 30...100

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SA5000-01 — 26.04.2021 —
SA5000
Flow sensor
SAD10XDBFRKG/US-100

Gases - operating mode "relative"


Setting range [m/s] 0...200
Greatest sensitivity [m/s] 30...100
Accuracy / deviations
Temperature drift [cm/s x 1/K] 0,003 m/s x 1/K (< 20 °C; > 70 °C)
Max. temperature gradient of
[K/min] 100
medium
Absolute operating mode
Repeatability 0,05 m/s; (water; Flow velocity: 0,05...3 m/s)
Relative operating mode
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum
sensitivity under the following conditions:; water: 20...70 °C; inlet
Accuracy
length: 1.5 m; DN25 (DIN 2448); mounting position according to
instructions; Accuracy can differ for other media and mounting positions.)
Repeatability 0,05 m/s; (water; Flow velocity: 0,05...3 m/s)
Temperature monitoring
Temperature drift ± 0,005 K/°C
Accuracy [K] ± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s)
Reaction times
Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09 [s] 1,5 (T09); (water; Flow velocity: 0,3...3 m/s)
Software / programming
hysteresis / window; normally open / closed; switching logic; current/
Parameter setting options frequency output; medium selection; Damping; Teach function; display can be
rotated and switched off; standard unit of measurement; process value color
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time [ms] 3
Type of operation DeviceID
Factory setting / ModE = (REL) 533
Supported DeviceIDs
ModE = (LIQU) 540
ModE = (GAS) 547
Operating conditions
Ambient temperature [°C] -40...80
Storage temperature [°C] -40...100
Protection IP 65; IP 67

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SA5000-01 — 26.04.2021 —
SA5000
Flow sensor
SAD10XDBFRKG/US-100

Tests / approvals
EMC DIN EN 60947-5-9
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 132
UL approval UL approval number I003
Mechanical data
Weight [g] 314
Material stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts) stainless steel (1.4404 / 316L); Gasket: FKM
Process connection threaded connection M18 x 1,5 Internal thread
Displays / operating elements
Display unit 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
Display Switching status 2 x LED, yellow
Measured values alphanumeric display, red/green 4-digit
Remarks
MW = Measured value
Remarks
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SA5000-01 — 26.04.2021 —
SA5000
Flow sensor
SAD10XDBFRKG/US-100

Connection

Colors to DIN EN 60947-5-2


OUT1:
- Switching output Volumetric flow quantity monitoring
- Frequency output Volumetric flow quantity monitoring
- IO-Link
OUT2:
- Switching output Volumetric flow quantity monitoring
- Switching output Temperature monitoring
- analog output Volumetric flow quantity monitoring
- analog output Temperature monitoring
- Frequency output Volumetric flow quantity monitoring
- Frequency output Temperature monitoring
- Input External Teach
Core colors :
BK = black
BN = brown
BU = blue
WH = white

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SA5000-01 — 26.04.2021 —