0% found this document useful (0 votes)
92 views36 pages

FieldMaxII SoftwareInstallationAndQuickStartGuide 1176436RevAA

This document provides instructions for installing the FieldMaxII software and connecting sensors to begin taking laser measurements. It includes mini-tutorials for tuning a laser and measuring energy, average power, and single-pulse energy using various FieldMaxII sensors. Safety information is also presented to avoid injury and damage to the meter or sensors.

Uploaded by

info
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views36 pages

FieldMaxII SoftwareInstallationAndQuickStartGuide 1176436RevAA

This document provides instructions for installing the FieldMaxII software and connecting sensors to begin taking laser measurements. It includes mini-tutorials for tuning a laser and measuring energy, average power, and single-pulse energy using various FieldMaxII sensors. Safety information is also presented to avoid injury and damage to the meter or sensors.

Uploaded by

info
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Software Installation and

Quick Start Guide

FieldMaxII ™
Software Installation and Quick Start Guide

FieldMaxII

27650 SW 95th Ave.


Wilsonville, OR 97070
FieldMaxII Software Installation and Quick Start Guide

This document and software is copyrighted with all rights


reserved. Under the copyright laws, this document and
software may not be copied in whole or in part or reproduced
in any other media without the express written permission of
Coherent, Inc. Permitted copies must carry the same
proprietary and copyright notices as were affixed to the
original. This exception does not allow copies to be made for
others, whether or not sold, but all the material purchased may
be sold, given or loaned to another person. Under the law,
copying includes translation into another language.

Coherent and the Coherent Logo are registered trademarks of


Coherent, Inc. FieldMaxII is a trademark of Coherent, Inc.
LabVIEW is a trademark of National Instruments Corporation.

Every effort has been made to ensure that the data given in
this document and software is accurate. The information,
figures, tables, specifications, part numbers, schematics and
software contained herein are subject to change without
notice. Coherent makes no warranty or representation, either
expressed or implied with respect to this document and
software. In no event will Coherent be liable for any direct,
indirect, special, incidental or consequential damages
resulting from any defects in its documentation.

ii
FieldMaxII Software Installation and Quick Start Guide

TABLE OF CONTENTS
Preface ...................................................................................... v
Publication Updates.................................................................. v
Symbols Used in This Document............................................. v

Software Installation ..............................................1


Quick Start: FieldMaxII-TOP ..........................11
Tuning a Laser With a Thermopile of Optical Sensor............ 12
Measuring Energy and Average Power With a Pyroelectric
Sensor ..................................................................................... 13
Measuring Power With a Thermopile or Optical Sensor ....... 14
Measuring Single-Pulse Energy With a Thermopile Sensor .. 15

Quick Start: FieldMaxII-TO.............................17


Tuning a Laser With a Thermopile of Optical Sensor............ 18
Measuring Power With a Thermopile or Optical Sensor ....... 19

Quick Start: FieldMaxII-P ................................21


Tuning a Laser With a Pyroelectric Sensor ............................ 22
Measuring Energy With a Pyroelectric Sensor ...................... 23

iii
FieldMaxII Software Installation and Quick Start Guide

iv
FieldMaxII Software Installation and Quick Start Guide

Preface
This guide includes:
• A section that explains how to install the FieldMaxII™ soft-
ware.
• A series of “mini-tutorials” that presents step-by-step instruc-
tions on connecting a sensor to your FieldMaxII meter and
begin taking measurements within minutes.

For detailed information on FieldMaxII, refer to the User


manual that shipped with your system.

Publication Updates
To view information that may have been added or changed since this
publication went to print, connect to www.Coherent.com.
Symbols Used in This Document

This symbol is intended to alert the operator to


the presence of exposure to hazardous visible
and invisible laser radiation.

This symbol is intended to alert the operator to


the presence of important operating and main-
tenance instructions.

v
FieldMaxII Software Installation and Quick Start Guide

vi
FieldMaxII Software Installation and Quick Start Guide

SOFTWARE INSTALLATION
This section explains how to install the FieldMaxII software.

Do not connect the FieldMaxII to the USB PC


port at this time. The software must be
installed before physically connecting the
meter to the computer.

Insert the FieldMaxII CD into your CD-ROM


drive. If Autorun is enabled on your system,
installation will start automatically; otherwise,
select Run from the Start menu and then type
D:\Setup.exe (substitute the appropriate letter
of your CD-ROM drive for D).
X

1
FieldMaxII Software Installation and Quick Start Guide

Click "Next" on the Welcome screen.


Y

Read the License Agreement and then select


"I accept the license agreement."
Z

[ Click "Next" to continue.

2
FieldMaxII Software Installation and Quick Start Guide

Fill in your name and organization.


\

(your name)

] Select "Only for me (your name)" and then click


"Next."

^ Select the default destination folder by clicking


"Next."

3
FieldMaxII Software Installation and Quick Start Guide

Click "Next" to automatically install the LabVIEW


TM

drivers and create a FieldMaxII desktop icon.


_

Click "Finish" to complete the software


installation and view the README file.
`

4
FieldMaxII Software Installation and Quick Start Guide

Connect the FieldMaxII to the USB PC port


before continuing with this installation.

When the Found New Hardware Wizard


appears, select "No, not at this time."
a

Click "Next" to continue.

5
FieldMaxII Software Installation and Quick Start Guide

Click "Next" to automatically install the software.

Click "Finish" to close the Wizard.

6
FieldMaxII Software Installation and Quick Start Guide

The FieldMaxII installation requires the


Found New Hardware Wizard to run twice—
the following step is the beginning of the second
Wizard cycle.

When the Found New Hardware Wizard


appears, select "No, not at this time."

Click "Next" to continue.

7
FieldMaxII Software Installation and Quick Start Guide

Click "Next" to automatically install the software.

Click "Next" to complete the installation.

If this FieldMaxII meter is connected to a new USB port, the


Found New Hardware Wizard will activate and must be completed
again.

8
FieldMaxII Software Installation and Quick Start Guide

9
FieldMaxII Software Installation and Quick Start Guide

10
FieldMaxII Software Installation and Quick Start Guide

QUICK START: FIELDMAXII-TOP


This section presents a series of “mini-tutorials” that explains how
to connect a sensor to your FieldMaxII-TOP meter and begin taking
measurements. For in-depth information about the FieldMaxII-TOP
meter, refer to the FieldMaxII-TOP User Manual (1086235).
Tutorials include:
• Tuning a laser with a thermopile or optical sensor (page 12)
• Measuring energy and average power with a pyroelectric sensor
(page 13)
• Measuring power with a thermopile or optical sensor (page 14)
• Measuring single-pulse energy with a thermopile sensor
(page 15)
Carefully review the following safety information to avoid personal
injury and to prevent damage to this meter or any sensor connected
to it.

Follow all laser safety procedures. The laser


must be blocked or switched OFF before begin-
ning the procedures described in this section.

Power to the FieldMaxII-TOP meter must be


OFF before beginning the procedures
described in this section.

11
FieldMaxII Software Installation and Quick Start Guide

Do not exceed the power/energy density limits


of the sensor.

Tuning a Laser With a Thermopile of Optical


Sensor

nConnect a thermopile or optical sensor to the


FieldMaxII-TOP 25-pin connector.
Tuning Needles

Apply power to
the meter.
o
Zone Indicator Bars

p
Use the Up and Down
arrows to select the
appropriate measurement
range (meter is
automatically placed in
Manual Ranging).
Tuning is shown on the display using tuning needles and
zone indicator bars. The tuning needles (at the top of the
display) are now zoomed in to enhance laser tuning. For
detailed information about Tuning mode, refer to the
FieldMaxII-TOP User Manual (1086235).

12
FieldMaxII Software Installation and Quick Start Guide

Measuring Energy and Average Power With a


Pyroelectric Sensor
The following illustration outlines how to set up a pyroelectric
sensor to take an energy or average power measurement.

Connect a pyroelectric sensor to the


25-pin connector. Note: If your sensor
has a BNC plug, you will need to attach
a 25-pin adapter.
n

Select Joules mode


to measure energy,
or Watts mode to J (indicates Joules mode)
measure average W (indicates Watts mode)
power.
o p
Press either the Up or
Down arrow to manually
select the range.
Note: Auto Range is not
available for this type of
sensor.
q
Adjust the trigger threshold from 2 to 20% of range. Make
sure the trigger threshold is set below the energy you plan
to measure.

rTake the measurement and observe the result on the


display.

13
FieldMaxII Software Installation and Quick Start Guide

Measuring Power With a Thermopile or Optical


Sensor
The following illustration describes how to take a power measure-
ment using a thermopile or optical sensor.

Connect a thermopile or optical sensor


to the 25-pin connector.
n

If Joules mode is currently


selected, press the J/W button
to select Watts
mode.
o
J (indicates Joules mode)
W (indicates Watts mode)

p
Press the Auto button
to turn on Auto Range.

qBlock the beam and then press the Zero button to set
the baseline for the measurement.

rUnblock the beam, take the measurement, and observe


the result on the display. Note: Thermopile sensors must
reach steady-state to obtain an accurate measurement.

14
FieldMaxII Software Installation and Quick Start Guide

Measuring Single-Pulse Energy With a


Thermopile Sensor
The following illustration explains how to take a single long-pulse
(1 ms to 10 sec.) energy measurement using a thermopile sensor.

Connect a thermopile sensor to the


25-pin connector.
n

Press the J/W button to select Watts mode and then


find the appropriate watts range by taking a couple of
sample measurements. The
appropriate range is the
lowest range available that
does not give an overrange J (indicates Joules mode)
W (indicates Watts mode)
error during the test
measurement.
o

p
After the sensor has settled to a minimum reading, block the
beam and then press the Zero button to set the baseline for
the measurement.

15
FieldMaxII Software Installation and Quick Start Guide

Press the J/W button to select Joules mode. The Range


(Up and Down arrows), Zero button, and Auto button should
not be used from this point
on. If an overrange error
occurs, the range must be
adjusted by returning to J (indicates Joules mode)
W (indicates Watts mode)
the Watts mode.
q

When FieldMaxII-TOP is prepared for the first measurement,


the TRIG? annunciator displays at the top of the display.

r
Expose the sensor to one laser pulse, take the measurement,
and observe the result on the display. The TRIG annunciator
displays during the measurement, showing that the meter is
currently calculating the measurement. The Zero button
should not be pressed between measurements.

16
FieldMaxII Software Installation and Quick Start Guide

QUICK START: FIELDMAXII-TO

This section includes two “mini-tutorials” that explain how to


connect a sensor to your FieldMaxII-TO meter and begin taking
measurements. For in-depth information about the FieldMaxII-TO
meter, refer to the FieldMaxII-TO User Manual (1086239).
Tutorials include:
• Tuning a laser with a thermopile or optical sensor (page 18)
• Measuring power with a thermopile or optical sensor (page 19)
Carefully review the following safety information to avoid personal
injury and to prevent damage to this meter or any sensor connected
to it.

Follow all laser safety procedures. The laser


must be blocked or switched OFF before begin-
ning the procedures described in this section.

Power to the FieldMaxII-TO meter must be


OFF before beginning the procedures
described in this section.

Do not exceed the power density limits of the


sensor.

17
FieldMaxII Software Installation and Quick Start Guide

Tuning a Laser With a Thermopile of Optical


Sensor

Connect a thermopile or optical sensor to the


FieldMaxII-TO 25-pin connector.
n

Tuning Needles

Apply power o
to the meter.
Stat Area

Avg Atten Hold

Auto Zero
Zone Indicator Bars

p
Use the Up and Down
arrows to select the
appropriate measurement range
(meter is automatically placed in
Manual Ranging).
Tuning is shown on the display using tuning needles and
zone indicator bars. The tuning needles (at the top of the
display) are now zoomed in to enhance laser tuning. For
detailed information about Tuning mode, refer to the
FieldMaxII-TO User Manual (1086239).

18
FieldMaxII Software Installation and Quick Start Guide

Measuring Power With a Thermopile or Optical


Sensor
The following illustration describes how to take a power measure-
ment using a thermopile or optical sensor.

Connect a thermopile or optical sensor to the


FieldMaxII-TO 25-pin connector.
n

Press the Auto


button to turn on
Auto Ranging.
o Stat

Avg Atten
Area

Hold

Auto Zero

p
Block the beam
and then press
the Zero button to set the
baseline for your new
measurement.
q
Unblock the beam, take the measurement, and observe
the result on the display.

19
FieldMaxII Software Installation and Quick Start Guide

20
FieldMaxII Software Installation and Quick Start Guide

QUICK START: FIELDMAXII-P

This section includes two “mini-tutorials” that explain how to


connect a sensor to your FieldMaxII-P meter and begin taking
measurements. For in-depth information about the FieldMaxII-P
meter, refer to the FieldMaxII-P User Manual (1086242).
Tutorials include:
• Tuning a laser with a pyroelectric sensor (page 22)
• Measuring energy with a pyroelectric sensor (page 23)
Carefully review the following safety information to avoid personal
injury and to prevent damage to this meter or any sensor connected
to it.

Follow all laser safety procedures. The laser


must be blocked or switched OFF before begin-
ning the procedures described in this section.

Power to the FieldMaxII-P meter must be OFF


before beginning the procedures described in
this section.

Do not exceed the power density limits of the


sensor.

21
FieldMaxII Software Installation and Quick Start Guide

Tuning a Laser With a Pyroelectric Sensor

Connect a pyroelectric sensor to the


FieldMaxII-P 25-pin connector.
Note: If your sensor has a BNC plug,
you will need to attach
a 25-pin adapter.
n

Tuning Needles

Apply power to the


meter.
o Zone Indicator Bars

pUse the Up and


Down arrows to select the
appropriate measurement
range.

Tuning is shown on the display using tuning needles


and zone indicator bars. The tuning needles (at the
top of the display) are now zoomed in to enhance
laser tuning. For detailed information about Tuning
mode, refer to the FieldMaxII-P User Manual (1086242).

22
FieldMaxII Software Installation and Quick Start Guide

Measuring Energy With a Pyroelectric Sensor


The following illustration outlines how to set up a pyroelectric
sensor to take an energy measurement.

Connect a pyroelectric sensor to the


FieldMaxII-P 25-pin connector.
Note: If your sensor has a BNC plug,
you will need to attach a 25-pin adapter.
n

Press either the Up


or Down arrow to
manually select the
range.
o
p
Adjust the trigger
threshold from
2 to 20% of range.
Make sure the trigger
threshold is set below the energy
you plan to measure.
q
Take the measurement and observe the result on the
display.

23
FieldMaxII Software Installation and Quick Start Guide

24
FieldMaxII Software Installation and Quick Start Guide

THIS PAGE INTENTIONALLY BLANK

25
FieldMaxII Software Installation and Quick Start Guide

THIS PAGE INTENTIONALLY BLANK

26
FieldMaxII ™ Software Installation and
Quick Start Guide
© Coherent, Inc., 3/2010. Printed in the U.S.A.
Part No. 1176436, Rev. AA

You might also like