Morley-IAS Fire Alarm Repeater Overview

The document is a technical datasheet requesting approval for a Honeywell touch screen LCD repeater panel with 320 characters for a proposed cancer care foundation hospital project. It provides details of the item, manufacturer, location of use, and technical specifications. Attachments include a sample, brochure, and catalogues. Approval from the contractor, CBRE, and client is requested.

Uploaded by

sanjay dalvi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views3 pages

Morley-IAS Fire Alarm Repeater Overview

The document is a technical datasheet requesting approval for a Honeywell touch screen LCD repeater panel with 320 characters for a proposed cancer care foundation hospital project. It provides details of the item, manufacturer, location of use, and technical specifications. Attachments include a sample, brochure, and catalogues. Approval from the contractor, CBRE, and client is requested.

Uploaded by

sanjay dalvi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TECHNICAL DATA SHEET

APPROVAL REQUEST (TDS)


HCPL/02012021/01 Rev: 0 Page 1 of 1
PROJECT: PROPSED CANCER CARE FOUNDATION,CHANDRAPUR PROJECT No:
Contractor : Harsh Constructions Pvt. Ltd.

SERIAL NO: MAY 1 2 9 REV No: R 0 DATE : - 05 JUNE 21

Item: Repeater panel wih 320 character/ Manufacturer: Honeywell BOQ Sr. No.: 14.03
Touch screen LCD display

list of make praposed in tender : Honey well


Location Of Use : Chandrapur Cancer Care Foundation Hospital Project
Technical Details : As attached
Attachments :
Sample Size Brochure Others
YES NO YES NO
Catalogues

For Contractor : Technical Details Specification Attached for an approval.

Comments

Submitted by : Sanjay D Dalvi Date: Signature:


For CBRE
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:


For CLIENT: ( In Case Client Approval is Required )
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:


Repeaters Datasheet
Product Overview
The Morley-IAS repeaters are compact remote control Key Features
units for Morley-IAS intelligent multi protocol fire alarm
control panels.
• Compatible with all Morley-IAS intelligent multi-
These units, along with other I/O peripheral devices and protocol fire alarm control panels
the external printer further enhance the flexibility and
• Connects to RS485 peripheral bus
functionality of our fire alarm control panel range.
• Active or Passive options
The repeaters provide an extension to the operation
of the fire alarm control panel. There are two types • Backlit adjustable alphanumeric display
available - passive with indications only and no controls, • General status LEDs
or active with both controls and indicators. Both display • Controls for system reset, accept, mute, silence
the operational state of the control panel using the 80
alarms, and self test (active repeater only)
character LCD display and the 7 LED status indicators.
• “Access Enable” key-switch on active repeater
In addition to the general status indicators the Active
repeater is fitted with key operated “Access Enable”
switch for the control functions. Individual buttons are
provided for System Reset, Mute, Accept, Sound Alarms,
Silence/Re-sound Alarms and Self test. Thus enabling
control functions to be duplicated in strategic locations
around the installation.
The Active repeater includes an integral self test
sequence guiding the operator through a preset
sequence to test the functionality of the control buttons,
key-switch and display indicators.
Each repeater is connected to the Morley-IAS fire alarm
control panels using the RS485 peripheral data port as
shown in the schematic overleaf. A maximum of 31 active
repeaters can be connected to the peripheral data port.
The fire alarm control panel supervises the connection
between itself and the repeater, proving the integrity of
the cabling and indicating faults both on the repeater and
the fire alarm control panel.
Passive repeaters are not supervised, but a loss of
communication with the fire alarm control panel will be
indicated on the passive repeater.
The repeater requires an external power supply of
+24Vdc (nominal) to operate. Power may be taken from
the auxillary supply of the control panel or from any other
suitable dc power supply.
Mechanical:
Weight 1.7kg (approx)

Operating Temperature +5°C to +45°C

Maximum Humidity 5% - 95% non-condensing

Electrical:
Operating Voltage 18 to 32 Vdc

Operating Current 90mA (Quiescent) 120m (Alarm)

Terminals Maximum cross section 2.5mm2

LED Indicators Fire, Fault, Disables, Accepted, Silenced, Power, Communications, Loss

EXrA User Controls Keyswitch activated - System Reset, Sound Alarms, Silence/Resound, Mute, Accept

and Self Test

Part Numbers: 709-701-001

709-601-001 Morley-IAS Active Repeater


709-701-001 Morley-IAS Passive Repeater
709-752 Morley-IAS Stainless Steel Semi-flush Active Repeater
020-835 Spare key switch and keys for Morley-IAS repeaters
002-600-002 Bezel Kit for Active or Passive Repeaters
795-004-001 RS485 Communication Module.
709-752

For further details on these or any other Morley-IAS products please


contact your local distributor, Morley-IAS Business Manager or via our
contact details found below.

Caburn House T: +44 (0) 1273 897 000


DOC REF: MIAS
Repeater 0715

2B Brooks Road F: +44 (0) 1273 376 894

Every care has been taken in the preperation of this datasheet but no liability can be accepted for the use of the
Lewes, E. Sussex E: sales@morleyias.co.uk
information therein. Design features may be changed or amended without prior notice. © Morley-IAS by Honeywell 2015
BN7 2BY UK www.morley-ias.co.uk