ME R A K I P R OJ E C T S I NDI A P V T . L T D.
ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS
A, 405-406, Kailas Business Park, Park Site, Vikhroli (West) Mumbai - 400079
Minutes of Meeting
Prepared by: Date: 20/10/2021
Priyanka Shivalkar (Manager Mechanical & Piping)
------------
Prepared for:
Orifood And Beverages Pvt. Ltd.
Sr. Prepared By Approved By Dated Revision Project No.
No. No.
1 Priyanka Mr. Manish Saxena 20th October 2021 R0 PSM- 21028
Shivalkar
CAPABALE, CONFIDENT & COMMITMENT
ME R A K I P R OJ E C T S I NDI A P V T . L T D.
ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS
A, 405-406, Kailas Business Park, Park Site, Vikhroli (West) Mumbai - 400079
Project Orifood And Beverages Pvt. Ltd.
Subject Rieco-Pneumatic Conveying System
Recorded by Vishal Agnihotri
Company Discipline Name
Meraki Projects (INDIA) Pvt. Ltd. Consultant Mr. Vishal Agnihotri
Mrs. Priyanka Shivalkar
Mr. Vijay Katke
Mr. Mahamuni
Rieco Industries Ltd. Supplier Mr. Ashwin Jadhav
Mr. Sahajad
CAPABALE, CONFIDENT & COMMITMENT
ME R A K I P R OJ E C T S I NDI A P V T . L T D.
ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS
A, 405-406, Kailas Business Park, Park Site, Vikhroli (West) Mumbai - 400079
No. Minutes Action by & Date
A review meeting was arranged in Meraki Office for approval of
Pneumatic Layout for Rieco – following deviations have been noted.
A MECHANICAL RELATED
1. Feed will be through screw conveyor & vibro sieve to day silo
Rieco
instead of Sack tip booth.
2. Fluidisation will be provided for Day Silo SMP & Day Silo WP. Rieco
3. Rieco is providing single feed screw conveyor instead of two feed
Rieco
screw conveyors for sachet feed silo to Multitrack sachet packing.
4. Blender to Blender distance changed to 1m instead of 1.4m. Rieco
5. FCS, SMP and WP dump hopper height is 1.1m instead of 0.6m. Rieco
B Instrumentation Related
1. MPIPL requested to share IO List based on P&ID’S. Rieco
2. MPIPL requested to share Instrument data sheets. Rieco
3. MPIPL suggested to have separate IO panel. Rieco
MPIPL Suggested to have Weighing system and VFD on
4. Rieco
Ethernet/Profinet communication.
Note: These minutes are official and automatically confirms if do not
responded. For any suggestions, additions, alterations,
interpretations, within 48hours to priyankas@[Link]