QUALITY NDT SERVICES
[Link]: PLOT NO B.G.A. 1/1,2,3 BHOSARI GENERAL BLOCK,
M.I.D.C., BHOSARI PUNE 411 026, PH: 020-27121843, 27119490
RADIAOGRAPHY, ULTRASONIC, MAGNETIC PARTICLE AND PENETRANT TESTING SERVICES
E-mail: bkp_qndt@[Link]/bhausaheb@[Link]
RADIOGRAPHIC EXAMINATION REPORT Page No : 1
Report No.: QNDT/23-24/3394 Date : 19/12/2023
To
Job : AL. Tension Bracket 30A
Accurate Technologies
F-2 Block,Plot No-W57/1/18, Material Specification : ALUMINIUM
MIDC, Pimpri,
RT : 100% [Link]. : ---
Pune: 411018
Joint ID : As Below [Link](mm) : 2 Reinforcement (mm) : 0.0
Equipment : X- Ray FOD(mm): 700 FSOFD(mm): 2
Kv: 150 mA : 5 Focal Spot(mm): 2mm X 2mm
Exposure Time (Min) : 0.5 Film : Agfa - D5 Screen F & B : 0.1 mm
Exp Tech : SWSI No of walls viewed : 1
No of Flims / Cassette : 1 ASTM : 1A DIN / BS : - --
IQI ASME : --- Sensitivity : W5 Film Density : 1.80 to 4.00
Welding Technique : --- Welder Name : --
Specification : ASME-SEC-V
Accept. Stand : ASTM-E505 Procedure No. :
Insp.
Sr. Film Size
Identification No. Observations Remarks Authority
No. (in inches)
/ Remark
[Link]-49-TB-30A
1 3X5 1-AB Porosity/Cat.A Level-I
2 3X5 2-AB Porosity/Cat.A Level-I
Shrinkage/Cat.C Level-I
3 3X5 3-AB Porosity/Cat.A Level-I
Shrinkage/Cat.C Level-II
4 3X5 4-AB Porosity/Cat.A Level-I
*NSD- No Significant Discontinuity
FOR QUALITY NDT SERVICES CUSTOMERS REPRESENTATIVE INSPECTION AUTHORITY