Condition

The document describes standards for testing the lightfastness of various materials using xenon arc lamps. It provides details on testing cycles, including lamp filters used, irradiance levels, temperatures and humidity levels during testing.

Uploaded by

kittiya.b024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views16 pages

Condition

The document describes standards for testing the lightfastness of various materials using xenon arc lamps. It provides details on testing cycles, including lamp filters used, irradiance levels, temperatures and humidity levels during testing.

Uploaded by

kittiya.b024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Standard

Type ID No. Topic

Standard Practice for Operating Xenon Arc


General ASTM G155
Lamp Apparatus for Exposure of Materials

Standard Test Methods for Evaluating the


Printing ink /Paper ASTM D3424 Relative Lightfastness and Weatherability of
Printed Matter
Standard Test Methods for Evaluating the
Printing ink /Paper ASTM D3424 Relative Lightfastness and Weatherability of
Printed Matter

Textiles-Tests for colour fastness Part B02


Textile ISO 105-B02 colour fastness to artificial light xenon arc
fading lamp test

Graphic technology – Prints and printing inks –


Printing ink /Paper ISO 12040 Assessment of light fastness using filtered
xenon arc light

Standard Practice for Xenon-Arc Exposures of


Coating ASTM D6695
Paint and Related Coatings

-
Cycle/ Filter Irradiance Wavelength
Method

- W/m2 nm

1 Daylight 0.35 ± 0.02 340

2 Daylight 0.35 ± 0.02 340

3 Daylight 0.35 ± 0.02 340

4 Window Glass 0.30 ± 0.02 340

5 Window Glass 1.10 ± 0.02 420

6 Window Glass 1.10 ± 0.02 420

7 Extended UV 0.55 ± 0.02 340

7A Daylight 0.55 ± 0.02 340

8 Extended UV 0.55 ± 0.02 340

9 Daylight 180 ± 2 300-400

10 Window Glass 162 ± 2 300-400

11 Window Glass 1.50 ± 0.02 420

12 Daylight 0.35 ± 0.02 340

real sunlight
1 Window Glass* -
(0.5 MJ/m2)
real sunlight
2 Window Glass* -
(0.5 MJ/m2)

3 Window Glass 0.35 ± 0.02 340


4 Daylight 0.40 ± 0.02 340

1.10 ± 0.02 420


A1 Daylight
42 ± 2 300-400
1.10 ± 0.02 420
A2 Daylight
42 ± 2 300-400
1.10 ± 0.02 420
A3 Daylight
42 ± 2 300-400
1.10 ± 0.02 420
B Daylight
42 ± 2 300-400
Cycle 1

Humidity

Temperature Temperature
Cycle
(Black Panel) (Chamber Air)
Effective humidity

- ̊C ̊C %

Light 63 ± 2.5 - -

Light 63 ± 2.5 - -

Light 77 ± 2.5 - -

Light 55 ± 2.5 - -

Light 63 ± 2.5 - -

Light 63 ± 2.5 - -

Light 70 ± 2.0 47 ± 2.0 -

Light 70 ± 2.0 47 ± 2.0 -

Light 89 ± 3.0 62 ± 2.0 -

Light - 63 ± 2.0 -

Light - 89 ± 2.0 -

Light - 63 ± 2.0 -

Light - 64 ± 2.0 -

- - - -

- - - -

Light 63 ± 3 - -
Light 63 ± 3 - -

Light 45 ± 3 - 40

Light 60 ± 3 - 15

Light 40 ± 3 - 85

Light 63 ± 3 -
Test Method

Cycle 2

Humidity

Temperature
Exposure time Cycle
(BPT)
Relative humidity

% RH min - ̊C

- 102 Light & WaterSpray -

- 102 Light & WaterSpray -

70 ± 10 90 Light & WaterSpray -

55 ± 10 up to user* - -

35 ± 10 102 Light & WaterSpray -

35 ± 10 228 Dark 43 ± 2.5

50 ± 10 40 Light & WaterSpray -

50 ± 5 40 Light & WaterSpray -

50 ± 10 228 Dark 38 ± 2.5

- 102 Light & WaterSpray -

50 ± 10 up to user* - -

30 ± 10 up to user* - -

30 ± 10 1,080 Dark -

- - - -

- - - -

40 ± 5 up to user* - -
40 ± 5 102 - -

- 102 - -

- 102 - -

- 90 - -

30 ± 5 up to user* - -
st Method

Cycle 2

Temperature
Relative humidity Exposure time Cycle
(Chamber Air)

̊C % min -

- - 18 -

- - 102 Dark

- - 30 -

- - - -

- - 18 -

- 90 ± 10 60 -

- - 20 Light

- - 20 Light

38 ± 2.0 95 ± 10 60 -

- - 18 -

- - - -

- - - -

35 ± 2.0 90 ± 10 360 -

- - - -

- - - -

- - - -
- - - -

- - - -

- - - -

- - - -

- - - -
Cycle 3

Temperature Temperature
Relative humidity Exposure time
(BPT) (Chamber Air)

̊C ̊C % min

- - - -

24 ± 2.5 - 95 ± 4 360

- - - -

- - - -

- - - -

- - - -

70 ± 2.5 47 ± 2.0 50 ± 10 60

70 ± 2.5 47 ± 2.0 50 ± 10 60

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -
- - - -

- - - -

- - - -

- - - -

- - - -
Cycle 4

Temperature Temperature Relative Exposure


Cycle
(BPT) (Chamber Air) humidity time

- ̊C ̊C % min

- - - - -

Dark 24 ± 2.5 - 95 ± 4 360

- - - - -

- - - - -

- - - - -

- - - - -

Dark & WaterSpray 38 ± 2.0 38 ± 2.0 95 ± 10 60

Dark & WaterSpray 38 ± 2.0 38 ± 2.0 95 ± 10 60

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -
- - - - -

- - - - -

- - - - -

- - - - -

- - - - -
Note

Step1&2 Repeat 9 time for total of 18h. And followed step 3

Time to exposure specified by user

Time to exposure specified by user

Step2 spray on specimen face and step4 spray on specimen front and back

Step2 spray on specimen face and step4 spray on specimen front and back

Step1 use to continuous light

open racks at an angle of 45 ̊ on outdoor exposure testing.

open racks at an angle of 45 ̊ on outdoor exposure testing.

-
-

You might also like