NAME OF SUPPORT: TYPE H3(Bracing) DATE: 15-04-2024
MAIN MEMBER: CH125x65x15 REVISION: R00
NODE NUMBER: DONE BY: AN
BEAM NUMBER: CHECKED BY: MA
LOAD COMBINATION: APPROVED BY: JJ
Support Reactions
1 Gravity shear in X axis, FX = 14.39 kN
2 Axial tensile force in Y axis, FY = 0.646 kN
3 Lateral shear in Z axis, FZ = 0.178 kN
4 Gravity moment in X axis, MX = 0.654 kN-m
5 Torsional moment in Y axis, MY = 0.266 kN-m
6 Lateral moment in Z axis, MZ = 0.066 kN-m
Considering DIAMOND WALRAVEN M12x53 DROP-IN Anchor bolt
7 Proposed Bolt diameter, φ = 12 mm
8 Tension capacity bolts, Fy’ = 6.43 kN
9 Shear capacity bolts, Fz’ = 6.43 kN
10 Total No. of bolts considered = 4 No.s
11 Direct pull-out force per bolt, fy = 0.16 kN FY / No. of bolts
12 Lever arm distance RX1 = 30.00 mm Ref.Drawing
13 Total number of bolts in Lever arm distance RX1 = 2 No.s Ref.Drawing
14 Lever arm distance RX2 = 170.00 mm Ref.Drawing
15 Total number of bolts in Lever arm distance RX2 = 2 No.s Ref.Drawing
16 Pull out force on extreme bolt due to pull-out moment, fyx” = 1.87 kN ∑MX*R / ∑R²
17 Lever arm distance, RZ1 = 30.00 mm Ref.Drawing
18 Total number of bolts in Lever arm distance, RZ1 = 2 No.s Ref.Drawing
19 Lever arm distance, RZ2 = 170.00 mm Ref.Drawing
20 Total number of bolts in Lever arm distance, RZ2 = 2 No.s Ref.Drawing
21 Pull out force on extreme bolt due to pull-out moment, fyz” = 0.19 kN ∑MZ*R / ∑R²
22 Hence, total pull-out force on extreme bolt, ƩFy = 2.22 kN fy + fyx” + fyz”
23 Direct shear force per bolt, ƩFzvx = 3.60 kN FX / No.of bolts
24 Direct shear force per bolt, ƩFzvz = 0.04 kN FZ / No.of bolts
25 Radial distance, RD1 = 120.20 mm Ref.Drawing
26 Total number of bolts in Radial distance, RD1 = 4 No.s
27 Radial distance, RD2 = 0.00 mm Ref.Drawing
28 Total number of bolts in Radial distance, RD2 = 0 No.s
2
29 Shear from twisting moment force per bolt, ƩFzr = 0.00 kN MY / ƩRD
30 Total Shear stress per bolt, ƩFz = 3.65 kN ƩFzr + ƩFzvx + ƩFzvz
31 Bolt utilization ratio = 0.912 <1; Hence Safe {(ƩFy / Fy’) + (ƩFz / Fz’)}
Base plate/Anchor plate design calculation
32 Proposed anchor plate Length along X-axis, Lpx = 200 mm Ref.Drawing
33 Proposed anchor plate Length along Z-axis, Lpz = 200 mm Ref.Drawing
34 Bolt edge distance required = 30 mm 2.5*Diameter of bolt
35 Provided edge distance = 30 mm
2
36 Yield stress of steel, Fyield = 250 N/mm
37 Permissible bending stress factor = 0.66
Plate thickness calculations
About X - Axis
38 Number of bolts in nearest line of bolts adjacent to column = 2 No.s
39 Restraint force on extreme bolt line, WX = 4.05 kN (fy + fyx”) * Number of bolts
40 Free length between nearest line of bolts & column face, LZ = 47.00 mm Ref.Drawing
41 Moment on plate at centre due to bolt force, Mpx = 0.191 kN-m WX*LZ
42 Hence, plate thickness required at centre; treqd = 5.89 mm √(6Mpx/(0.66*Lpx*Fyield))
About Z - Axis
43 Number of bolts in nearest line of bolts adjacent to column = 2 No.s
44 Restraint force on extreme bolt line, WZ = 0.70 kN (fy + fyz”) x Number of bolts
45 Free length between nearest line of bolts & column face, LX = 7.50 mm Ref.Drawing
46 Moment on plate at centre due to bolt force, Mpz = 0.005 kN-m WZ*LX
47 Hence, plate thickness required at centre; treqd = 0.98 mm √(6Mpz/(0.66*Lpz*Fyield))
48 Maximum plate thickness required, tmax = 5.89 mm
= 8.00 mm; Round up
Supporting member to plate welded connection design
49 Considered weld thickness all around the member = 4 mm
50 Effective throat thickness of weld = 2.8 mm 0.7*weld thickness
2
51 Allowable tensile stress on weld, f yt = 150 N/mm 0.6*250 (AISC)
2
52 Allowable compressive stress on weld, f yc = 150 N/mm 0.6*250 (AISC)
2
53 Allowable shear stress on weld, f ys = 75 N/mm 0.3*250 (AISC)
2 2
54 Resultant Shear acting on the plate, Frs = 14.39 kN √(F x + F z)
2
55 Effective area of weld = 1428.56 mm Ref.Drawing
4
56 Effective moment of inertia of weld in primary axis of weld, Izz = 3413437.22 mm Ref.Drawing
4
57 Effective moment of inertia of weld in secondary axis of weld, Ixx = 759466.28 mm Ref.Drawing
4
58 Polar moment of inertia of weld w.r.t support C.G, Irr = 4172903.5 mm Izz + Ixx
59 Distance to extreme weld from weld CG in Z axis; ymax.xx = 66.50 mm Ref.Drawing
60 Distance to extreme weld from weld CG in X axis; ymax.zz = 46.00 mm Ref.Drawing
61 Radial distance to extreme weld from weld CG; ymax.rr = 80.90 mm Ref.Drawing
3
62 Full weld section modulus in Z axis; Zzz = 51329.8831 mm Izz/ymax.xx
3
63 Full weld section modulus in X axis; Zxx = 16510.1365 mm Ixx/ymax.zz
3
64 Full weld polar section modulus Zrr = 51581.0075 mm Irr/ymax.rr
[(FY/Aw)/f yt] + [(MZ/Zzz)/f yt] + [(MX/Zxx)/f yt] +
65 Combined stress utility ratio on weld = 0.479 <1; Hence safe
[(Frs/Aw)/f ys] + [(MY/Zrr)/f ys]
Summary:
Bolt specification: DIAMOND WALRAVEN M12x53 DROP-IN
Number of bolts: 4 No.S
Plate Size: 200 mm x 200 mm x 8 mm
Size of Weld: 4mm full length fillet weld between the supporting member and the plate