0% found this document useful (0 votes)
51 views54 pages

Report of Steel Gate 2

The document provides the structural analysis and design calculations for a steel box gate. It includes details on codes, material properties, geometry, loads, SAP2000 modeling, output from SAP2000 such as member forces and reactions, and design of base plate and connections.

Uploaded by

Ibrahim Ezzat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views54 pages

Report of Steel Gate 2

The document provides the structural analysis and design calculations for a steel box gate. It includes details on codes, material properties, geometry, loads, SAP2000 modeling, output from SAP2000 such as member forces and reactions, and design of base plate and connections.

Uploaded by

Ibrahim Ezzat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Design Calculation Report For STEEL GATE

01
Table of Contents
1 - INTRODUCTION. ……………………………………………………………………….3
2 - CODES, MATERIAL PROPERTIES…………………………………………3
2.1 - REFERENCES AND CODES………………………………………………3
2.2 - MATERIAL PROPERTIES …………………………………………………3
2.2.1 – STEEL TUBE……………………………………..……………………….3
2.2.2 – G.I STEEL BOLT/SCREW…………………………………………….…3
2.3 - GEOMETRY………………………………………………………………….4
3 - DESIGN [Link] LOADS……………………………………5
3.1 – DEAD LOAD ……………………………………..………………….……….5

3.2 – WIND LOAD ……………..……………….……………………………….…7


4- SAP IN PUT …………………………………..………………………………….…9

5- SAP OUT PUT …………………………….…………………………………….……. .30

6- DESIGN OF BASE PLATE ………………………..……………………………....42

7 - MEMBER TO MEMBER CONNECTION …………………….....…….50


8 - DESIGN OF BOLTE OF DOOR HINGE ...............………….....…….51
9- DRAWING ……….............................………………..……………………………....54

02
1- INTRODUCTION

this report prepared to provide the structural analysis and design


calculations of Steel Box Gate. Fixing with RC footing connecting by steel
plate and 6 bolt dia 24 mm L = 25 CM

2 - CODES, MATERIAL PROPERTIES.

2.1 - REFERENCES AND CODES.

Drawing attach with report


ASCE 7-10
QCS 2014

2.2 - MATERIAL PROPERTIES


2.2.1 – Steel Box
Yield Strength = 400 MPa
Density, Y = 7.8 T/m³

2.2.2 –STEEL BOLT/SCREW


Grade 8.8
Yield strength = 640 MPa I
Tensile Strength = 800 MPa
Shear strength ps = 375 MPa \
Tension strength pt = 560 MPa

03
2.3 - GEOMETRY

04
3 - DESIGN METHODOLOGY AND LOADS

3.1 DESIGN CONCEPT AND ASSUMPTIONS

The analysis Steel box was analyzed & designed using SAP 2000 based on reference
codes mentioned in section 2.1 of this report.
The steel box was modeled as frames .
Wind loads were added and applied normal in steel box and considered as uniformly
distributed load.
Support model reactions were considered in connection design.

DEAD LOAD

Automatic calculated by sap 200

LIVE LOAD

05
06
WIND LOAD ACCORDING TO ASCE -7-22

1- Velocity Pressure (qz)

Velocity Pressure (qz= 0.613 *kz*kzt*ke*v2) N/M2

GATE height = 2.90 M

Velocity Pressure Exposure coefficient kz= 0.57

Ground Elevation Factor ke = 0.85


Topographic Factor kzt = 1
Risk Category = II given
Building Exposure Category = B given

Ultimate Wind Speed v = 38 m/s

qz= 0.613 *0.57*1*.85*38*38= 0.428 KN/m2

2 :- Wind Pressure

Windward wind coefficient CP = 0.80


Windward Wind Pressure = 0.428 * 0.80 = 0.343 KN/M2 = 0.034T/M2

07
08
4- SAP 2000 IN PUT

09
SAP2000 1-29-24 [Link]

DOOR HINGES

SAP2000 v14.2.0 - File:GATE - Copy - 3-D View - Tonf, m, C Units


SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - 3-D View - Tonf, m, C Units


12
13
14
15
16
17
18
19
20
21
22
23
24
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Frame Span Loads (LIVE) (As Defined) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Frame Span Loads (WIND LOAD) (As Defined) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Frame Span Loads (WIND LOAD) (As Defined) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - X-Z Plane @ Y=0 - Tonf, m, C Units


SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - X-Z Plane @ Y=0 - Tonf, m, C Units


5- SAP 2000 OUT PUT

30
SAP2000 1-29-24 [Link]

0.00 0.50 0.70 0.90 1.00

SAP2000 v14.2.0 - File:GATE - Copy - Steel Design Sections (ASCE 10-97) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Moment 2-2 Diagram (1.2DEAD+1.6LIVE+TEMP) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Axial Force Diagram (1.2DEAD+1.6LIVE+TEMP) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Joint Reactions (1.2DEAD+1.6LIVE+TEMP) - Tonf, m, C Units


SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Joint Reactions (1.2DEAD + 1 WIND +LIVE+TEMP) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Joint Reactions (SRIVCE( DEAD + LIVE )) - Tonf, m, C Units
SAP2000 1-29-24 [Link]

SAP2000 v14.2.0 - File:GATE - Copy - Joint Reactions (1.2 DEAD + 1.6LIVE +Wind) - Tonf, m, C Units
TABLE: Joint Reactions
Joint OutputCase F1 F2 F3 M1 M2 M3
Text Text Tonf Tonf Tonf Tonf-m Tonf-m Tonf-m
190 SRIVCE( DEAD + LIVE ) 0.009628511 -0.191991277 0.334165302 -0.451842258 -0.011995915 -0.031777235
198 SRIVCE( DEAD + LIVE ) 0.060245802 -0.468005203 0.68690694 0.079059823 -0.00171618 -1.04457992
200 SRIVCE( DEAD + LIVE ) -0.009601045 -0.187174034 0.334653543 -0.461652993 0.011632311 0.029726858
202 SRIVCE( DEAD + LIVE ) -0.068996573 -0.489327275 0.687275475 0.088349591 -0.000255434 1.047830883
205 SRIVCE( DEAD + LIVE ) -0.033714987 -1.096929387 0.312926767 0 0 0
206 SRIVCE( DEAD + LIVE ) 0.03243313 -1.10155999 0.312258368 0 0 0
258 SRIVCE( DEAD + LIVE ) -0.25658514 0 -3.00E-02 0 0 0
259 SRIVCE( DEAD + LIVE ) -0.062971521 0 -2.97E-03 0 0 0
260 SRIVCE( DEAD + LIVE ) -1.277840869 0 4.33E-02 0 0 0
261 SRIVCE( DEAD + LIVE ) -1.981484338 0 -4.65E-02 0 0 0
272 SRIVCE( DEAD + LIVE ) -1.98 0 -5.13E-02 0 0 0
273 SRIVCE( DEAD + LIVE ) -1.305105124 0 4.75E-02 0 0 0
274 SRIVCE( DEAD + LIVE ) -0.039289926 0 -2.90E-03 0 0 0
275 SRIVCE( DEAD + LIVE ) -0.237609474 0 -3.94E-02 0 0 0
TABLE: Joint Reactions
Joint OutputCase F1 F2 F3 M1 M2 M3
Text Text Tonf Tonf Tonf Tonf-m Tonf-m Tonf-m
190 1.2DEAD+1.6LIVE+TEMP 29.68264513 -0.307186043 -2.084634962 -0.722947613 0.009061128 -0.050843576
198 1.2DEAD+1.6LIVE+TEMP -1.093815609 -0.748808324 2.528996009 0.126495717 0.266633363 -1.671327871
200 1.2DEAD+1.6LIVE+TEMP -29.65638112 -0.299478454 -2.277007502 -0.73864479 0.066890233 0.047562973
202 1.2DEAD+1.6LIVE+TEMP 1.263321882 -0.782923641 2.705853858 0.141359346 -0.266412008 1.676529413
205 1.2DEAD+1.6LIVE+TEMP -29.54143283 -1.75508702 1.156437763 0 0 0
206 1.2DEAD+1.6LIVE+TEMP 29.55791954 -1.762495984 1.172178507 0 0 0
258 1.2DEAD+1.6LIVE+TEMP -0.410536224 0 0.414358794 0 0 0
259 1.2DEAD+1.6LIVE+TEMP -0.100754434 0 0.271614235 0 0 0
260 1.2DEAD+1.6LIVE+TEMP -2.044545391 0 -6.916174789 0 0 0
261 1.2DEAD+1.6LIVE+TEMP -3.17037494 0 7.182805067 0 0 0
272 1.2DEAD+1.6LIVE+TEMP -3.163569119 0 7.644135159 0 0 0
273 1.2DEAD+1.6LIVE+TEMP -2.088168199 0 -7.36846937 0 0 0
274 1.2DEAD+1.6LIVE+TEMP -0.062863882 0 0.235473793 0 0 0
275 1.2DEAD+1.6LIVE+TEMP -0.380175158 0 0.653720718 0 0 0
TABLE: Joint Reactions
Joint OutputCase F1 F2 F3 M1 M2 M3
Text Text Tonf Tonf Tonf Tonf-m Tonf-m Tonf-m
190 1.2DEAD + 1 WIND +LIVE+TEMP 29.68264513 -0.282262093 -2.084634962 -0.664290291 0.009061128 -0.046718314
198 1.2DEAD + 1 WIND +LIVE+TEMP -1.093815609 -0.688052759 2.528996009 0.116232318 0.266633363 -1.535722448
200 1.2DEAD + 1 WIND +LIVE+TEMP -29.65638112 -0.275179869 -2.277007502 -0.678713856 0.066890233 0.043703887
202 1.2DEAD + 1 WIND +LIVE+TEMP 1.263321882 -0.719400083 2.705853858 0.129889966 -0.266412008 1.540501955
205 1.2DEAD + 1 WIND +LIVE+TEMP -29.54143283 -1.612685686 1.156437763 0 0 0
206 1.2DEAD + 1 WIND +LIVE+TEMP 29.55791954 -1.619493513 1.172178507 0 0 0
258 1.2DEAD + 1 WIND +LIVE+TEMP -0.377226819 0 0.414358794 0 0 0
259 1.2DEAD + 1 WIND +LIVE+TEMP -9.26E-02 0 0.271614235 0 0 0
260 1.2DEAD + 1 WIND +LIVE+TEMP -1.878658465 0 -6.916174789 0 0 0
261 1.2DEAD + 1 WIND +LIVE+TEMP -2.913142327 0 7.182805067 0 0 0
272 1.2DEAD + 1 WIND +LIVE+TEMP -2.906888705 0 7.644135159 0 0 0
273 1.2DEAD + 1 WIND +LIVE+TEMP -1.918741878 0 -7.36846937 0 0 0
274 1.2DEAD + 1 WIND +LIVE+TEMP -5.78E-02 0 0.235473793 0 0 0
275 1.2DEAD + 1 WIND +LIVE+TEMP -0.349329137 0 0.653720718 0 0 0
TABLE: Joint Reactions
Joint OutputCase F1 F2 F3 M1 M2 M3
Text Text Tonf Tonf Tonf Tonf-m Tonf-m Tonf-m
190 1.2 DEAD + 1.6LIVE +Wind 0.011554213 -0.397456859 0.400998362 -0.935395646 -0.014395097 -0.065784655
198 1.2 DEAD + 1.6LIVE +Wind 0.072294962 -0.96885588 0.824288328 0.163668211 -0.002059416 -2.1624704
200 1.2 DEAD + 1.6LIVE +Wind -0.011521254 -0.387484289 0.401584252 -0.955705652 0.013958773 0.061540002
202 1.2 DEAD + 1.6LIVE +Wind -0.082795887 -1.012996448 0.82473057 0.182899721 -0.000306521 2.169200485
205 1.2 DEAD + 1.6LIVE +Wind -0.040457984 -2.270843318 0.37551212 0 0 0
206 1.2 DEAD + 1.6LIVE +Wind 0.038919755 -2.280429507 0.374710041 0 0 0
258 1.2 DEAD + 1.6LIVE +Wind -0.531177903 0 -0.035984924 0 0 0
259 1.2 DEAD + 1.6LIVE +Wind -0.130362501 0 -0.003569534 0 0 0
260 1.2 DEAD + 1.6LIVE +Wind -2.645362986 0 0.051970411 0 0 0
261 1.2 DEAD + 1.6LIVE +Wind -4.10203293 0 -0.055807144 0 0 0
272 1.2 DEAD + 1.6LIVE +Wind -4.093227124 0 -0.06158746 0 0 0
273 1.2 DEAD + 1.6LIVE +Wind -2.701804952 0 0.056992711 0 0 0
274 1.2 DEAD + 1.6LIVE +Wind -0.081337293 0 -0.003484123 0 0 0
275 1.2 DEAD + 1.6LIVE +Wind -0.491894822 0 -0.047318513 0 0 0
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Anchor (name) MIT-SE Plus 4.6 Dimension MIT-SE Plus 300ml

Article code 1710017 Approval ETA-10/0130


Vinylester mortar, styrene free

PRODUCT
MIT-SE Plus Vinylester mortar, styrene free. European Technical Approval Option 1 for cracked and non-cracked concrete with anchor rod
and with rebar used as anchor. Fire resistance test certification F30-F120. VOC free according to Swiss legislation and certified A+ according
to DEVL 1101903D / DEVL 1104875A. LEED - Test Report. Certification for drinking water Systems. The anchor may also be used under
seismic influence for performance category C1. Universal mortar for highest loads in almost all building materials. Application also in damp
and water-filled drill holes. Variable setting depth. Suitable for overhead Fixings. Simple and speedy working. Styrene free and low odour.
Colour of mortar: grey, Indoor (zinc plated) and outdoor (stainless steel) applications.

DESIGN CALCULATION
This calculation is based on specific values exclusively for the product above.
Any changes to the brand or physical conditions for design will require a recalculation of the anchor design.

ANCHOR PLATE
The design program assumes, in accordance with EOTA TR029, that the anchor plate does not deform as a result of applied actions.
Thus, and in accordance with EOTA TR029, the anchor plate shall be sufficiently stiff and its design should be carried out according to
standards for steel structures ensuring elastic behaviour.

INSTALLATION
All conditions of the European Technical Approval (ETA) and Mungo technical publications shall be complied with in all detail.
The load values are valid only if the installation has been carried out correctly.

ADDITIONAL PROOFS
The designing and calculation of the anchorage should be carried out in accordance with EOTA TR029.

ATTENTION
The loads as well as the installation data can vary. Please consult our website [Link] to download the newest version.

Tension Reinforcement
N Sd,Z 6.74 kN Diameter 11 mm
Distance rebars 120 mm
Shear Distance stirrups 120 mm

V Sd,X 0.68 kN Edge reinforcement No

V Sd,Y -4.82 kN
Anchor Plate
Bending b fixX 600 mm

M Sd,X 0.87 kNm b fixY 350 mm

M Sd,Y 0.02 kNm t fix 20 mm

Edge distance
Torsion
C Xp 200 mm
M Sd,Z 10.28 kNm
C Xn 200 mm

Lever arm C Yp 150 mm


C Yn 150 mm
No lever arm has been applied

Spacing
Concrete
SX 200 mm
C20/25 Uncracked
SY 200 mm
Member height h 500 mm
Profile
No Profile has been applied

29-Jan-24 MIT-SE Plus 4.6 page 1


Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Anchor/thread diameter: d 20 mm
Outside diameter of anchor: d nom 20 mm
Drill hole diameter: d0 24 mm
Depth of drilled hole: h1 175 mm
Bonded setting depth h nom 170 mm
Effective anchorage depth: h ef 170 mm
Diameter of clearance hole in fixture: df 22 mm
Thickness of fixture: t fix 20 mm
Spanner: SW 0 mm
Max setting torque T inst 120 Nm
Max long term temperature +24 °C
Max short term temperature +40 °C
Use category, concrete Dry/Wet
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Concrete

Uncracked concrete strength C20 (20/25)

f ck = 20 MPa
f ck,cube = 25 MPa
Ψc = 1.00

Calculated design loads on anchor(s)

Tension

N Sd,Z = 6.74 kN
M Sd,X = 0.87 kNm
M Sd,Y = 0.02 kNm
N Sd,Z anchor 1 = 2.41 kN
N Sd,Z anchor 2 = 2.40 kN
N Sd,Z anchor 3 = 2.39 kN
N Sd,Z anchor 4 = 0.40 kN
N Sd,Z anchor 5 = 0.39 kN
N Sd,Z anchor 6 = 0.38 kN

N gsd = 8.37 kN
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Shear

V Sd,X = 0.68 kN V gsd = 4.87 kN


V Sd,Y = -4.82 kN α = 278.0 deg
M Sd,Z = 10.28 kNm
V Sd anchor 1 = 11.13 kN α1 = 245.8 deg
V Sd anchor 2 = 4.63 kN α2 = 190.0 deg
V Sd anchor 3 = 9.68 kN α3 = 118.1 deg
V Sd anchor 4 = 11.22 kN α4 = 295.2 deg
V Sd anchor 5 = 4.85 kN α5 = 350.5 deg
V Sd anchor 6 = 9.79 kN α6 = 60.7 deg

Calculation of Utilizations according to: TECHNICAL REPORT TR029

( β - is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

N Rk,s = 98.00 kN
γ Ms = 1.40

N Rd,s = 70.00 kN β N, Steel Failure 3%

Tension - Combined Pull Out and Concrete Cone Failure (group of anchors 1, 2, 3, 4, 5 and 6 )

N 0Rk,p = 101,333 N
A0 p,N = 160,000 mm2
A p,N = 400,000 mm2
Ψs,Np = 0.925
Ψre,Np = 1.000
Ψec,Np = 0.783
Ψg,Np = 1.000
N Rk,p = 183.557 kN
γ Mc = 1.20
N Rd,p = 152.964 kN β N, Combined Failure 5%
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Tension - Concrete Cone Failure(group of anchors 1 2 3 4 5 6)

N 0Rk,c = 77,750 N
A0 c,N = 160,000 mm2
A c,N = 400,000 mm2
Ψs,N = 0.925
Ψre,N = 1.000
Ψec,N = 0.783
N Rk,c = 140.838 kN
γ Mc = 1.20
N Rd,c = 117.365 kN β N, Concrete Cone Failure 7%

Tension - Splitting Failure(group of anchors 1, 2, 3, 4, 5 and 6 )

N 0Rk,c = 77,750 N
A 0c,N = 160,000 mm2
A c,N = 400,000 mm2
Ψs,N = 0.92
Ψre,N = 1.00
Ψec,N = 0.78
Ψh,sp = 1.42

N Rk,sp = 200.61 kN
γ Msp = 1.20

N Rd,sp = 167.18 kN β N, Splitting Failure 5%

Calculation of Utilisations - Shear loads

Shear - Steel Failure Without Lever Arm

V Rk,s = 49.00 kN
γ Ms = 1.40

V Rd,s = 35.00 kN β v Steel Failure Without Lever Arm 32%

Steel Failure With Lever Arm

No Lever Arm has been applied


Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Shear - Concrete Pryout Failure (anchor 1 alone )

V Rk,cp = 59.93 kN
γ Mc = 1.40
V Rd,cp = 42.81 kN β v Concrete Pryout Failure 26%

Shear - Concrete Edge Failure(group of anchors 1, 2, 3, 4, 5 and 6 edge Yn)

V 0Rk,c = 121,192 N
A 0c,V = 500,000 mm2
A c,V = 400,000 mm2
Ψs,V = 0.82
Ψh,V = 1.00
Ψa,V = 1.44
Ψec,V = 0.76
Ψre,V = 1.00

V Rk,c = 87.51 kN
γ Mc = 1.40

V Rd,c = 62.50 kN β v Concrete Edge Failure 83%

The selected edge distance does not allow ETAG001 Annex C or TR029 design methods to be applied.
Consequently, for anchor groups, the calculation is carried out on all possible subgroups made of two anchors
only. Additionally only the anchor row closer to the considered edge, which could consist in one anchor only, is
assumed to take up entirely the shear load. The reported results are referred to the most unfavorable conditions.
Please refer to the ACP-Method I design guide for more information.

UTILISATIONS (Anchor 1)

Steel βN = 3% βV = 32% β = β 2N + β 2V = 10%


Concrete βN = 7% βV = 83% β = (βN + βV ) /1.2 = 75%

RESULT

Ok. The product meets the design criteria


Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be found
inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming that the anchor
plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate shall be sufficient stiff. The
user must verify this condition, since the base plate stiffness is not automatically calculated by the software. The transfer of loads from
anchors into base material must be verified in accordance with ETAG 001 Annex C or TR29 Section 7. The design method is valid only
for clearance hole in the fixture with a diameter not larger than the values given in ETAG 001 Annex C or TR29 Table 4.1.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and complies
with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and safety
regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any errors or
omissions are the responsibility of the user. The user must ensure that the most current version of the program is installed by way of
the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines, without any
guarantee of suitability for any specific application.
Case: 2 base blate connection
Check on All Around Weld: Connection: Box 400x200x7mm
Properties Of Weld: Detail:
Sw= 0.5 cm
L= 40 cm
H= 20 cm
2
A= 61 cm
Ix= 16660.083 cm4
Iy= 7645.083 cm4
Sx= 833.0042 cm3
Sy= 764.5083 cm3

Straining Actions :
Mx= 0.08000 t.m
My= 0.00200 t.m
Qx= 0.06000 t
Qy= 0.46000 t
N= 0.68000 t
Mt= 0.96000 t.m

Check On Weld:
2
f= + + = 0.021013 t/cm

qx= = 0.0015 t/cm

qy= = 0.023 t/cm

feff= = 0.045114 t/cm2

τ= = 0.12 t/cm2 (ASIC Design Guide 09 - P.13 - Table 4.1)

+ = 0.223629 < 1 Safe

49
7- MEMBER TO MEMBER CONNECTION

Case: 2 member to member weld


Check on All Around Weld: Connection: Box 200x100x4mm
Properties Of Weld: Detail:
Sw= 0.5 cm
L= 20 cm
H= 100 cm
2
A= 121 cm
Ix= 91525.083 cm4
Iy= 10280.083 cm4
Sx= 4576.2542 cm3
Sy= 1028.0083 cm3

Straining Actions :
Mx= 0.60000 t.m
My= 1.03000 t.m
Qx= 0.55000 t
Qy= 2.43000 t
N= 0.53000 t
Mt= 1.22000 t.m

Check On Weld:
2
f= + + = 0.117685 t/cm

qx= = 0.0275 t/cm

qy= = 0.0243 t/cm

feff= = 0.133753 t/cm2

τ= = 0.061 t/cm2 (ASIC Design Guide 09 - P.13 - Table 4.1)

+ = 0.253603 < 1 Safe

50
51
8-

53
230 225 225 303 250 225 271 211 204 280 230 299 250 225 225 225 225 303 250 227 227 250 303 225 225 225 225 250 299 230 280 204 211 271 225 250 303 225 225 230

1004
150
2 SECTION

275

South
50
200

150 100 1 SECTION

50 Ø40

North 80
150 400 600
10220
1999 250 Key Plan: BOUNDARY GATE-1

GATE
OUTSIDEINSIDE

GATE
N

100 BOUNDARY GATE-2

GATE
OUTSIDE

INSIDE

+1.05
+1.05

DA
GATE +1.05

+1.05

+1.05

+1.05

1950 3095 3095 1930


200
2 700

Detail A Gate Hing


UP

1 2964
2804 10 mm metal Sheet cut to curve

2054
2264 10 mm dia anchor

Detail C lock
Detail B ground guide rail detail
at side door
50
APPROVAL STATUS
50
50
110
2000
6240 1980

DB

QATAR

QATAR

Gate Guide supporting wheel


REFERENCE DRAWINGS

STONE WALL CLADDING EDGE

EDGE OF KERB
50

-DIPPED

L 350 x 600 x
20mm THK.
PLATE. HOT

GALVANIZED PAINTED
200 x 400mm STEEL POST

FINISH 300 x 600 x 20mm THK. PLATE. HOT-DIPPED 00 ISSUED FOR APPROVAL 7/11/23 ---
GALVANIZED PAINTED FINISH
TOP OF KERB 40mm NON-SHRINK GROUT REV. DESCRIPTION DATE DWN CHKD APPD APPD

ANCHOR BOLT WITH COVER CAP; 20Ø


250mm LONG Chemical anchor bolt; GRADE 8.8

K SC1
SC1

SECTION

South
J 250mm DEEP DRILL + HILTI HIT HY 200R
OR 500 V3 PLANT REINFORCEMENT
EXISTING FOOTING
LC

North
50 ±1545 200 ±6200 200 ±1555 50
200 200

EDGE OF KERB
±1880

CLADDING EDGE
STONE WALL
350 x 600 x 20mm THK. PLATE. HOT-DIPPED
KERB EDGE

GALVANIZED PAINTED
FINISH
KERB EDGE

Al Emadi Building, 250 D Ring Road


Tel : +974 44553366
Fax : +974 44553377

H 7003 40mm NON-SHRINK GROUT


300 x 600 x 20mm THK. PLATE. HOT-DIPPED
QATAR
P.O. Box : 22373 Doha - Qatar
[Link]

2 GALVANIZED PAINTED FINISH

METES TRADING & CONTRACTING


Tel:+974 4452 7912

800

800
200 x 400mm STEEL POST Fax:+974 4452 8282
Email: info@[Link]

ANCHOR BOLT WITH COVER CAP; 20Ø


250mm LONG Chemical anchor bolt; GRADE 8.8

SC1 SC1 AL DAAYEN FARM


400 400
PRIVATE RESIDENTIAL ESTATE IN QATAR
8 9 PLAN

STEEL GATE PEDESTAL DETAILS Main Entrance Gate

THIS IS A CAD DRAWING AND MUST NOT BE ALTERED MANUALLY


DRAWING NUMBER: SCALE AS SHOWN ORIG. DWG SIZE: A1 REV.
ADF-GH-SD-MW-MEG-0001 Sht. 001 cont. END 03