0% found this document useful (0 votes)
25 views12 pages

Excelsys Coolx 1800: High Efficiency, Intelligent and Reliable 1800 W Modular Power Supplies

Uploaded by

sigit raharjo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views12 pages

Excelsys Coolx 1800: High Efficiency, Intelligent and Reliable 1800 W Modular Power Supplies

Uploaded by

sigit raharjo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

EXCELSYS COOLX®1800

HIGH EFFICIENCY, INTELLIGENT AND RELIABLE 1800 W MODULAR POWER


SUPPLIES
=

Advanced Energy's CoolX®1800 series, part of our Excelsys


product line, is an intelligent modular power supply. The
CoolX1800 delivers an incredible 1800 W in a compact 1U high
package with PMBus™ digital communications, control and
reliability in addition to the most comprehensive feature set and
specifications available.
AT A GLANCE
PRODUCT HIGHLIGHTS  ield-configurable — plug and play
F
power
Modular Power Supply CX18S CX18M
 eries and parallel outputs for higher
S
 p to 1800 W
U
voltages and currents
 p to 12 outputs
U Power
 ounting options — base/side and
M
 ll outputs isolated (1850 VAC)
A
DIN-Rail mounting 1800 W 1800 W
 ariable fan speed control
V

TYPICAL APPLICATIONS
Reliability Slots
 TBF > 200,000 hours
M Medical
 linical diagnostic equipment, medical
 C 6 6
 evel 4 input surge protection
L

 3.5 W always ON auxiliary power


2 lasers, dialysis equipment, radiological
output imaging, chemical chemistry Cooling
 afety approved to 5000 m altitude
S Industrial Variable fan speed control
 1% efficiency
9 T est and measurement, industrial
 ive-year warranty
F machines, automation equipment, Parameters
printing, telecommunications, MIL-COTS
Flexibility 267 mm x 127 mm x 41 mm
A nalog and digital management — Audio Equipment
(10.5 in x 5 in x 1U)
PMBus™ monitoring and control  i Rel, harsh industrial electronics,
 H

capability radar (marine- and ground-based),


Certifications
communications, test and measurement
Medical (CX18M)
 I EC60601-1 3rd edition,

IEC60601-1-2 4th edition (EMC)


2  MOPP
D  ual fused
 I SO13485

Industrial (CX18S)
 I EC60950, IEC62368-1

S  EMI F47*

Defense/Aero (All Models)


M
 IL-STD-810G
COOLX1800 SERIES

MODULES

CoolX CoolMods Table

Single Output Modules Vnom(V) Set Point Adjust Range (V) Imax(A) Power (W)
(1 Slot)

CmA 5 2.5-6.0 30.0 150

CmB 12 6.0-15.0 23.3 280


1 2

CmC 24 15.0-28.0 12.5 300

CmD 48 28.0-58.0 6.25 300


3

High Power Modules (3 Slot)

CmE4 24 24-25.2 37.5 900

CmF4 48 48-50.4 18.75 900

Dual Output Modules (1 Slot)

CmG5 V1 24 3.0-30.0 4.0 120

V2 24 3.0-30.0 4.0 120

CmH V1 5 3.0-6.0 10.0 60


6

V2 24 3.0-30.0 4.0 120

Wide Trim Modules (1 Slot)

CmA-W01 5 1.0-6.0 30 150

CmB-W01 12 1.0-15.0 23.3 280


2

CmC-W01 24 2.0-28.0 12.5 300

CmD-W01 48 3.0-58.03 6.25 300


1 Full dynamic specifications may not be met at full load when output voltage is trimmed above 13 V.

2 Max Trim 14 V when used with High Power Module

3 Max Trim 56 V when used with High Power Module

4 a) Only one High Power module (CmE or CmF) can be used per CoolPac.
b) During load transients starting from 0% load on the High Power modules, other modules in the CoolPac may experience an output voltage
dynamic during the load change. Contact applications support for details or support..
5 For the CmG module the max combined power of both outputs is 200 W.

6 For the CmH module the max combined power of both outputs is 180 W.

*SEMI F47 compliant at input voltages > 180 VAC. Consult Advanced Energy for details.

2 [Link]
COOLX1800 SERIES

ELECTRICAL SPECIFICATIONS

Input

Parameter Conditions/Description Min Nom Max Units

Nominal Input Voltage Range Universal Input 47-440Hz 100 — 240 VAC

AC Operating Input Range 85 — 264 VAC

Extended AC Operating Range Maximum for 5 seconds — — 300 VAC

DC Input Voltage Range 120 300 VDC

Input Current 90 VAC @ 1080 W — — 14.5 A

Inrush Current 230 VAC @ 1800 W — — 25 A

Power Factor 120 VAC @ 1400 W 0.98 — — —

Undervoltage Lockout Shutdown 65 — 74 VAC

Input Fuses Rating Dual Fused (Line and Neutral) 250 VAC — 16 — A

Efficiency 230 VAC, 1800 W with 6 x CmC CoolMods 91 %

Output

Parameter Conditions/Description Min Nom Max Units

Power Rating CX18: See derating curves — — 1800 W

Minimum Load 0 — — A

Line Regulation For ±10% change from nominal line — — ±0.1 %

CmE, CmF, CmG, CmH — — ±0.5 %

Load and Cross Regulation For 25% to 75% load change — — ±0.2 %

Transient Response Voltage Deviation, for 25% to 75% load change 0.5A/uS — — 4 (4) %

Settling Time, *CmE and CMF in () — — 500 (1000) µS

Ripple and Noise 100 mV or 1.0% pk-pk. 20 MHz BW — — 1 %

CmF — — 1.5 %

Overvoltage Protection Tracking OVP Level (N/A in CmE and CmF, CmG, CmH) 105 — 125 %

Latching OVP Level 125 — 160 %

Remote Sense Max. line drop compensation (N/A in CmG and CmH) — — 0.5 VDC

Overshoot — — 1 %

Rise Time Monotonic — — 10 ms

CmG and CmH — — 20 ms

Capacitive Load CmA-CmE 10 mF

CmG, CmH < 0.47 mF

Turn-On Delay From AC in — — 1000 ms

From Global Enable — — 10 ms

From CoolMod Enable — — 10 —

Hold-Up Time For nominal output voltages at full load CmE and CmF 16 — — ms
combination at 1300 W

CoolMod Power As per CoolMod table — — — —

Output Adjustment Range Manual: Multi-turn potentiometer. As per CoolMod table — — — —

Vtrim: As per CoolMod table — — — —

Overcurrent Protection Straight line with hiccup activation @ 35% Vo nom 110 130 150 %
CmE, CmF, CmG, CmH: Current limit hiccup autorecovery

Short Circuit Protection Yes, Autorecovery — — — —

OverTemperature Protection Yes, Autorecovery (CmG, CmH latch off ) — — — —

[Link] 3
COOLX1800 SERIES

ELECTRICAL SPECIFICATIONS (CONTINUED)

Auxiliary Output

Parameter Conditions/Description Min Nom Max Units

Auxiliary Output Voltage Aux Voltage Option A 11.76 12 12.24 V

Aux Voltage Option B 4.75 5 5.25 V

Load Regulation — — ±2 %

Line Regulation For ±10% change from nominal line — — ±0.5 %

Maximum Output Current Aux Voltage Option A — — 1.96 A

Aux Voltage Option B — — 4.7 A

Load Capacitance — — 1000 uF

Output Overcurrent Protection Hiccup 110 140 %

Short Circuit Protection Yes, Autorecovery — — — —

Galvanic Isolation

Parameter Conditions/Description Min Nom Max Units

Input to Output Reinforced (2 x MOPP); contact Advanced Energy for 4000 — — VAC
Hi-Pot instructions

Input to Case Basic (1 x MOPP) 1850 — — VAC

Output to Case Basic (1 x MOPP) 1850 — — VAC

Output to Output Basic (1 x MOPP) 1850 — — VAC

CmG, CmH V1-V2 Operational 500 — — VDC

Reliabilty

Parameter Conditions/Description Min Nom Max Units

Reliability and MTBF MTBF of >>3 million hours, Telecordia SR-332, Issue 4 — 0.33 — Fpmh
CoolPac (excludes fans)

Warranty 5 years — — — —

Environmental

Parameter Conditions/Description Min Nom Max Units

Operating Temperature Operates to specification below -20°C after 10 min warmup -40 — 70 °C

Storage Temperature -40 — 85 °C

Derating See derating curves — — — —

Relative Humidity Non-condensing 5 — 95 %RH

Shock and Vibration MIL-STD-810G Method 514.6 — — — —

Altitude — — 5000 m

4 [Link]
COOLX1800 SERIES

ELECTRICAL SPECIFICATIONS (CONTINUED)

Leakage Currents

Parameter Conditions/Description Nom Units

AC Leakage Current Input to earth ground

Normal Condition (High Line) Mains Voltage 264 VAC/60 Hz 244 µA

Single Fault Condition (High Line) Mains Voltage 264 VAC/60 Hz 435 µA

Touch Current

Normal Condition Mains Voltage 264 VAC/60 Hz 14.2 µA

Single Fault Condition Mains Voltage 264 VAC/60 Hz 246 µA

EMC

Parameter Conditions/Description Notes

Radiated Emissions EN 55011, EN 55022 and FCC, Class B — Compliant


1

Conducted Emissions1 EN 55011, EN 55022 and FCC, Class B — Compliant

Power Line Harmonics EN 61000-3-2, Class A — Compliant

Voltage Flicker EN 61000-3-3 — Compliant

ESD EN 61000-4-2, level 4, 8 kV contact, 15 kV air — A

Radiated Immunity EN 61000-4-3, level 3, 10 V/m 80-2700 MHz — A

Electrical Fast Transient EN 61000-4-4, level 4, ±4 kV — A

Surge Immunity EN 61000-4-5, level 4, 2 kV DM, 4 kV CM — A

Conducted RF Immunity EN 61000-4-6, level 3, 10 Vemf 150 KHz-80 MHz — A

Power Frequency Magnetic Field EN 61000-4-8, level 4, 30 A/m — A

Voltage Dips and Interruptions EN61000-4-11 10 ms A


100 ms B
500 ms B

1 Consult AE applications for system level compliance

Standards and Directives

Standard Conditions/Description

Safety Agency Approvals EN60601-1 3rd Edition, UL60601-1, CSA601, EN60950 2nd Edition, CSA C22.2 No. 60950-1

IEC/EN 60950-1, Edition 2 UL 60950-1/CSA 22.2 No 60950-1, Edition 2; 5000 m (16,400 ft) altitude, 100 VAC to 240 VAC ±10%
and all national deviations

IEC/EN 60601-1, Edition 3 IEC 60601-1 (2005), EN60601-1 (2006), ANSI/AAMI ES 60601-1 (2005), CAN/CSA C22.2 No. 60601-1 (2008);
and all national deviations 5,000 m (16,400 ft) altitude, 100 VAC to 240 VAC ±10%

IEC 62368 Edition 2 IEC 62368-1 (2014) Edition 2; 5000 m (16,400 ft) altitude, 100 VAC to 240 VAC ±10%

IEC 60601-1-2 Edition 4 IEC 60601-1-2 (2014)

Protection class Class I

ROHS EU DIRECTIVE 2015/863 RoHS compliant

REACH-171 Compliant

Conflict Materials Compliant with Conflict Free Sourcing Initiative

[Link] 5
COOLX1800 SERIES

MECHANICAL SPECIFICATIONS

Mechanica Data

Parameter Description

Dimensions (L x W x H) LxWxH 267 mm x 127 mm x 41 mm (10.5” x 5” x 1U)

Weight Nominal Weight: CoolPac + 6 x CoolMods 1.6 Kg

Connectors Description Mating Connectors (if applicable)

AC/DC IEC input (Option) Screw terminal Block and IEC inlet options. —
In Mating Connectors column state "See
Interface page"

Main DC output terminal block M4 Screws —


(CmA-CmF, CmM-CmQ)

Main DC output terminal block Camden - CTB9350/4A Camden - CTB9200/4A or Würth Elektronik - 691 352 710 004
(CmG, CmH)

System Signal Connector J1007 Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850;
Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which
includes locking tab and polarization keying

Output Signal Connectors Molex 87833-0631 6-way Locking Molex 51110-0660; Non Locking Molex 51110-0650;
J1001-1006 Crimp Terminal: Molex p/n 50394 or Molex 51110-0656 which
includes locking tab and polarization keying

Output Signal Connector Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850
(CmG, CmH) Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which
includes locking tab and polarization keying

Output Sense Connectors J3 JST-S2BPH-K(LF)(SN) JST PHR2. Crimp Terminal JST BPH-002TP.0.5S or SPH-002T-
P.05S

Auxiliary Output Connector J1 Molex 1041880210 2pin

6 [Link]
COOLX1800 SERIES

MECHANICAL SPECIFICATIONS (CONTINUED)

Mechanical Drawings

1 Standard airflow direction


* Maximum screw penetration from base does not exceed 1.5mm.

[Link] 7
COOLX1800 SERIES

EFFICIENCY AND DERATING CURVES

Efficiency vs Load

92

90

88

86

84

82

80

78

76
0 20 40 60 80 100 120

Load (%)

240V

CX18 Input Voltage Typical Derating Curves CX18 Temperature Derating Curve
2000 2000
1800 1800
1600 1600
1400 1400
Output Power (W)
Output Power (W)

1200 1200
1000 1000
800 800
600 600
400 400
200 200
0 0
50 70 90 110 130 150 170 190 210 230 -30 -20 -10 0 10 20 30 40 50 60 70 80

Input Voltage (Vac) Ambient Temperature (ºC)


CX18 Reverse Fan CX18 IEC Terminal Block

8 [Link]
COOLX1800 SERIES

INTERFACE (CONTINUED)

Input Connectors

Standard (Screw Terminal) Option 1 (IEC Terminal)

CoolPac Connectors

[Link] 9
COOLX1800 SERIES

INTERFACE (CONTINUED)

CoolMod Connectors

10 [Link]
COOLX1800 SERIES

CONFIGURATION

*CmE or CmF High Power Module (3 slot module) can only occupy Slots D/E/F.

Configuration Example 1
CoolX part number CX18S-ADG##E-N-A specifies the following product;
• CX18S 1800W IEC60950 approved
• Slot 1: CmA: 2.5-6.0V (150W)
• Slot 2: CmD: 28-58V (300W)
• Slot 3: CmG: Dual output 3-30V (120 per channel)
• Slot 4: Not Available (CmE is three slot CoolMod module)
• Slot 5: Not Available (CmE is three slot CoolMod module)
• Slot 6: CmE: 22.8-25.2 (900W)
• Option N: Nominal Output voltage settings
• Option A: 12V/(1.96)A Bias Supply Voltage

Configuration Example 2
CoolX part number CX18M-BABBDC-N-B specifies the following product;
• CX18M 1800W IEC60601-1 approved
• Slot 1: CmB: 6-15V (280W)
• Slot 2: CmA: 2.5-6.0V (150W)
• Slot 3: CmB: 6-15V (280W)
• Slot 4: CmB: 6-15V (280W)
• Slot 5: CmD: 28-58V (300W)
• Slot 6: CmC: 15-28V (300W)
• Option N: Nominal Output voltage setting
• Option B: 5V/(4.7A) Nominal Output voltage setting

[Link] 11
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three decades
to perfecting power for its global customers. AE designs and
manufactures highly engineered, precision power conversion,
measurement and control solutions for mission-critical appli-
cations and processes.

AE’s power solutions enable customer innovation in complex


semiconductor and industrial thin film plasma manufacturing
processes, demanding high and low voltage applications,
and temperature-critical thermal processes.

With deep applications know-how and responsive service and


support across the globe, AE builds collaborative partnerships
to meet rapid technological developments, propel growth for
its customers and power the future of technology.

Specifications are subject to change without notice. Not responsible for errors
or omissions. ©2019 Advanced Energy Industries, Inc. All rights reserved.
For international contact information, Advanced Energy® and AE® are U.S. trademarks, and CoolX® is a U.S. and
visit [Link] Europe trademark of Advanced Energy Industries, Inc.

ENG-LV-COOLX1800-235-15 04.20