Sb10en 60808 1.00
Sb10en 60808 1.00
User’s Manual
PMM SB-10
SWITCHING CONTROL BOX
If the instrument is used in any other way than as described in this Users Manual, it may become unsafe
Before using this product, the related documentation must be read with great care and fully understood to
familiarize with all the safety prescriptions.
To ensure the correct use and the maximum safety level, the User shall know all the instructions and
recommendations contained in this document.
This product is a Safety Class III instrument according to IEC classification and has been designed to
meet the requirements of EN61010-1 (Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use).
In accordance with the IEC classification, the power supply of this product meets requirements Safety
Class II and Installation Category II (having double insulation and able to carry out mono-phase power
supply operations).
This product has a Pollution Degree II normally only non-conductive pollution occurs. Occasionally,
however, a temporary conductivity caused by condensation must be expected.
Contents III
Figures
Figure Page
1-1 PMM SB-10 front panel…….........…................................. 1-3
1-2 PMM SB-10 rear panel……………................................... 1-3
2-1 Single SB-10 installation example…………………………. 2-2
2-2 Multiple SB-10 installation example……………………….. 2-2
Tables
Table Page
1-1 PMM SB-10 Technical specifications............................... 1-2
IV Contents
SAFETY RECOMMENDATIONS AND INSTRUCTIONS
This product has been designed, produced and tested in Italy, and it left the factory in conditions fully
complying with the current safety standards. To maintain it in safe conditions and ensure correct use,
these general instructions must be fully understood and applied before the product is used.
• When the device must be connected permanently, first provide effective grounding;
• If the device must be connected to other equipment or accessories, make sure they are all safely
grounded;
• In case of devices permanently connected to the power supply, and lacking any fuses or other
devices of mains protection, the power line must be equipped with adequate protection
commensurate to the consumption of all the devices connected to it;
• In case of connection of the device to the power mains, make sure before connection that the voltage
selected on the voltage switch and the fuses are adequate for the voltage of the actual mains;
• Devices in Safety Class I, equipped with connection to the power mains by means of cord and plug,
can only be plugged into a socket equipped with a ground wire;
• Any interruption or loosening of the ground wire or of a connecting power cable, inside or outside the
device, will cause a potential risk for the safety of the personnel;
• Ground connections must not be interrupted intentionally;
• To prevent the possible danger of electrocution, do not remove any covers, panels or guards installed
on the device, and refer only to NARDA Service Centers if maintenance should be necessary;
• To maintain adequate protection from fire hazards, replace fuses only with others of the same type
and rating;
• Follow the safety regulations and any additional instructions in this manual to prevent accidents and
damages.
Safety consideration V
EC Declaration of Conformity
In accordance with the Decision 768/2008/EC
Compliant to the Directives: EMC 2014/30/EU, Low Voltage 2014/35/EU, RoHS 2011/65/EU
Also compliant to the ISO/IEC standards 17050-1 and 17050-2
The manufacturer,
declares, under its sole responsibility, that the product: SB-10 Switching Control Box
conforms with the essential requirements of the Low Voltage Directive 2014/35/EU, of the EMC Directive
EMC 2014/30/EU and of the RoHS directive 2011/65/EU.
VI EC Conformity
1 - General Information
1.1 Documentation Enclosed with this manual are:
• a service questionnaire to send back to NARDA in case of equipment
service is needed
• an accessories check list to verify all accessories enclosed in the
packaging.
1.2 Introduction to The PMM SB-10 Switch Control Box is a versatile and expandable
PMM SB-10 accessory for the electric and magnetic fields and electrosmog
measurement devices family.
Either the OR-03 Optical Repeater with all their field probes and the EP-
60X series are supported. The EHP-50, EHP-50A, EPH-50B, EHP-50C,
EHP-50D and EHP-50E are not supported.
One PMM SB-10 allows to take field measurement with up to 10 measuring
devices connected at the same time, either placed in different measuring
points and/or working on different frequency and full scale ranges. it is
possible to have a chain up to five SB-10 to connect up to 50 remote
devices.
The PMM SB-10 is powered by an External DC supply or by a PC with
apposite USB A or B type cable. With the USB is possible to supply only up
to three SB-10 (30 remote devices).
One PMM SB-10 allows to connect up to ten devices via optical fiber to the
Personal Computer by a single RS232 interface connection. Besides, using
one free USB port, you can connect another SB-10 with low consumption.
1.3 Standard accessories The standard accessories included with PMM SB-10 are:
Weight 1300 g
1. On Led ;
2. Device-1 Fiber optic connector;
3. Device-2 Fiber optic connector;
4. Device-3 Fiber optic connector;
5. Device-4 Fiber optic connector;
6. Device-5 Fiber optic connector;
7. Device-6 Fiber optic connector;
8. Device-7 Fiber optic connector;
9. Device-8 Fiber optic connector;
10. Device-9 Fiber optic connector;
11. Device-10 Fiber optic connector.
Legend:
2.2 Initial inspection When receiving the equipment, first inspect the shipping card box for any
damages.
If the shipping box is damaged, it should be kept until the contents of the
shipment have been checked for completeness and the instrument has
been checked mechanically and electrically.
2.3 Packing and Verify the availability of all the shipped items with reference to the shipping
Unpacking check list enclosed with the Operating Manual.
Notify any damage to the forwarder personnel as well as to your NARDA
Representative.
2.4 Environment The operating environment of the PMM SB-10 Switching Control Box is
specified to be within the following limitations:
• Temperature -10° to +40° C
• Humidity < 90% relative
2.5 Return for service If the instrument should be returned to NARDA for service, please complete
the service questionnaire enclosed with the Users Manual and attach it to
the instrument.
To minimize the repair time, be as specific as possible when describing the
failure. If the failure only occurs under certain conditions, explain how to
duplicate the failure.
If possible, reuse of the original packaging to ship the equipment is
preferable.
In case other package should be used, ensure to wrap the instrument in
heavy paper or plastic.
Use a strong shipping container and use enough shock absorbing material
around all sides of the equipment to provide a firm cushion and prevent
movement in the container.
To prevent damage during shipment in particular protect the front panel.
Seal the shipping container securely.
Mark the shipping container FRAGILE to encourage careful handling.
2.6 Equipment cleaning Use a clean, dry, non-abrasive cloth for external cleaning of the equipment.
2-2 Installation
2.8 External DC supply The PMM SB-10 con be powered either by an external power supply or by
the USB port of the Personal Computer.
The provided DC external power supply can be used at 50 or 60 Hz from
100 up to 240 V. It is provided with different mains plugs according to
different international requirement.
In case the PMM SB-10 is powered by an external power supply, follow the
procedure below:
• Connect the external DC supply into the mains;
• Connect the external DC supply output connector to the POWER input
on the rear panel of the PMM SB-10.
In case the PMM SB-10 is powered by the PC USB port, follow the
procedure below:
• Connect the USB A/B connector on the rear panel to one free USB port
of the Personal Computer.
Up to five10 can be powered by the PC USB port.
2.9 Installation To install the PMM SB-10 simply connect the provided optical fiber to the
DEVICE-X connector on the front panel taking care of the insertion key,
then connect the other side of the optic fiber cable to the measuring device
OPTIC LINK connector, either a Probe with optic link built in or the PMM
OR03 for probes without optic link built in.
When more than one up to five SB-10 are used each of them can be
powered using only one power supply.
The External DC supply can be connected to either of them.
The supply voltage is propagated between boxes by the Extension
Cable.
To power on or off the PMM SB-10 operate the ON-OFF push button on the
rear panel.
Installation 2-3
This page has been left blank intentionally
2-4 Installation
3 –PMM SET ADDRESS Operating instructions
3.1 Introduction This chapter is a guide for using the PMM SET Address Utility provided with
the PMM SB-10 Switching Control Box.
The PMM SET ADDRESS is an utility that integrates the PMM SB10
Switching Control Box and the PMM OR03 Optical Repeater.
When several PMM OR03 Optical Repeater with probe are connected to
the PMM SB-10 each of them need to be set with a different address.
With the PMM SET ADDRESS Utility you can associate an address at each
Optical Repeater connected to the PMM SB-10.
The updates for PMM OR03 software and firmware are available for
download from the internet web site www.narda-sts.it or directly from
the commercial offices of NARDA.
3.4 To run the program To run the utility double click on the Setadd53.exe icon
3.5 To start the program In case the PMM SB10 or PMM OR03 are OFF or they are not connected
properly or the serial port is wrong or the communication is not correct an
error message window will be displayed:
• Device: It shows the name and the release firmware of the device
connected to the SB-10.
3.6 To use the software Once the connection is established, the utility starts to recognize the device
and the probe connected to the PMM SB-10.
If the probe is not connected to the device, the utility shows the message
“Probe missing”:
At the end of the process, the software shows the Release and Date of the
device connected to the SB-10.
The default address of each device is 00 and the utility will show the
message “ADDRESS received 00”.
To change the address of the device, enter a new address (for example 05)
and click WRITE.
The utility shows the message “ADDRESS received 05”
Dear Customer
thank you for purchasing a NARDA product! You now own a high-quality instrument that will give you many years of reliable service. NARDA recognizes the
importance of the Customer as reason of existence; in this view, any comment and suggestion you would like to submit to the attention of our service
organization is kept in great consideration. Moreover, we are continuously improving our quality, but we know this is a never ending process. We would be glad if
our present efforts are pleasing you. Should one of your pieces of NARDA equipment need servicing you can help us serve you more effectively filling out this
card and enclosing it with the product.
Nevertheless, even this product will eventually become obsolete. When that time comes, please remember that electronic equipment must be disposed of in
accordance with local regulations. This product conforms to the WEEE Directive of the European Union
(2002/96/EC) and belongs to Category 9 (Monitoring and Control Instruments). You can return the instrument to us free of charge for proper environment friendly
disposal. You can obtain further information from your local NARDA Sales Partner or by visiting our website at www.narda-sts.it.
Servizio richiesto: Service needed:
Solo taratura Riparazione Riparazione & Taratura Taratura SIT Altro:
Calibration only Repair Repair & Calibration Certified Calibration Other:
Ditta:
Company:
Indirizzo:
Address:
Persona da contattare: Telefono:
Technical contact person: Phone n.
Modello: Numero di serie:
Equipment model: Serial n.