High performance

ultrasound for all


Philips HD7 ultrasound system specifications

The HD7 brings you a potent array of the features and capabilities drawn from Philips
higher-end systems in a compact mobile unit perfect for either shared service or
application-specific use in every area of your facility. The Philips HD7 provides you
with a rich combination of advanced performance, efficient workflow and elegant
data management, all at a very attractive price point.

Key Highlights:
• Proven, reliable system architecture and software
• Advanced imaging, measurement and quantification technologies
• Broad application support
• Wide array of transducers
• Simple image and Doppler optimization
• Economy without compromise
System specifications

Applications • Pulse Inversion Harmonic imaging


• Abdominal • Contrast imaging
• Small parts and superficial • Adaptive Doppler
• Pediatric • Adaptive Color Doppler
• Musculoskeletal • Color Tissue Doppler imaging
• Neonatal • Pulsed Wave Tissue Doppler imaging
• Urology
• Obstetrical System architecture
• Gynecological and fertility • All-digital broadband beamformer
• Prostate • Microfine 2D focusing with Dynamic Focal Tuning
• Vascular • 232 dB full time input dynamic range
– Cerebrovascular • 1,024 digitally-processed channels
– Peripheral vascular • Continuously variable steering in 2D, color and Doppler modes
– Intraoperative vascular • 2D Opt signal processing with 2X multi-line parallel processing
• Transcranial Doppler and frequency compounding
• Cardiac • iSCAN one-touch Intelligent Optimization
– Adult • iSCAN Doppler one-touch optimization
– Pediatric
– Stress Transducers
• Electronic switching of up to four transducers
Imaging modes • Dedicated (Pedoff) connector available for non-imaging
• Philips Microfine 2D focusing CW and PW transducers
• Philips Color Power Angio imaging (CPA) • Continuous dynamic receive focusing on all transducers
• Directional Color Power Angio imaging – S4-2 Broadband Sector
• M-mode – s8 Broadband Sector
• Anatomical M-mode – C5-2 Broadband Curved
• Color M-mode – C6-3 Broadband Curved
• Pulsed Wave Doppler – C8-5 Broadband Curved
• Continuous Wave Doppler – C8-4v Broadband Curved Array
• 3D – E6509 Broadband Curved
• Color compare mode – L12-3 Broadband Linear
• Dual mode – L12-5 50 mm Broadband Linear
• Duplex for simultaneous 2D and Doppler – 15-6L Broadband Compact Linear
• Triplex mode for simultaneous 2D, Doppler, and color or CPA – D5009V Cardiac and Vascular Non-imaging
• 2D Optimization Signal Processing
• Tissue Harmonic Imaging (THI)
• Intelligent Doppler
• Reconstructed zoom with pan (read zoom)
• Philips high-definition zoom (write zoom)
• Panoramic imaging
• Trapezoidal imaging
Measurements and Analysis Connectivity
• Comprehensive measurement tools • USB parts
– Vascular • 80 GB hard drive space
– Cardiac • Standard CD-R/RW
– Ob/Gyn and Fertility • DICOM 3.0 print and store service class user
– General Imaging • DICOM structured reporting for cardiac and Ob/Gyn
• Modality Performed Procedure Step (Mpps)
QLAB advanced quantification software • Modality Worklist
• Optional off-cart support
• Region of Interest (ROI) Power requirements
• Intima Media Thickness (IMT) • Power: 1150VA
• Power consumed: 600VA
Cineloop review • Frequency: 50 to 60 Hz
• Acquisition, storage, and display in real-time and duplex modes of • Voltage: 100 to 240 VAC
up to 1,000 frames (four minutes in Quick Review) of 2D and
color images Electrical safety standards
• Supports two-buffer Dual Imaging mode of up to 500 frames • CSA C22.2 No. 601.1
per buffer • IEC 60601-1
• UL 60601-1
ECG and Physio • EN 60601-1
• One three-lead ECG input
• One external ECG input Environmental
• Two physio input channels (1V, p-p) • Heat dissipation : <2500 BTUs/hour (fully loaded)
• Selectable ECG triggered skipping between 1 and 20
Maintenance and Serviceability
Physical dimensions • Philips Remote Services connectivity
• Depth: 40.3 in/102.4 cm • Optional service agreements
• Height (adjustable): 51.8 - 58.4 in/131.5 - 148.3 cm • Online and phone support
• Control panel height (adjustable): 32.3 - 38.8 in/82 - 98.6 cm • Clinical applications support
• Width: 21.6 in/55 cm
• Weight: 165 lbs /75 kg (no peripherals) For more information
• Visit: www.philips.com/HD7
Ergonomics • For more detailed specifications and a transducer guide,
• Large 15-inch (333 x 263 mm) high-resolution monitor ask your Philips representative
• Independent swivel and tilt monitor
• Adjustable control panel height

Miscellaneous system data


• Footswitch
• Gray shades: 256 (8 bits) in 2D, M-mode and Doppler
spectral analysis
• Acquisition frame rate: >230 frames per second in High Frame
Rate mode (dependent on transducer, field of view, depth
and angle)
Philips Healthcare is part of
Royal Philips Electronics

Interested?
Would you like to know more about our imaginative
products? Please do not hesitate to contact us.
We would be glad to hear from you.

On the web
www.philips.com/healthcare

Via email
[email protected]

By fax
+31 40 27 64 887

By mail
Philips Healthcare
Global Information Center
P.O. Box 1286
5602 BG Eindhoven
The Netherlands

By phone
Asia
Tel: +852 2821 5888

Europe, Middle East, Africa Your nearest Philips Healthcare representative:


Tel: +49 7031 463 2254

Latin America
Tel: +55 11 2125 0764

North America
Tel: +425 487 7000
1 800 285 5585 (toll free, US only)

© 2008 Koninklijke Philips Electronics N.V.


All rights are reserved.

Philips Medical Systems Nederland B.V. reserves the right to make changes in specifications and/or to discontinue any product at any time without
notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Printed in USA
4522 962 31721/795 * FEB 2008

You might also like