Multiparameter Patient Monitor
Features Trends & Storage
Wi-Fi (Optional)
Tabular Trend Graphical Trend
LAN Output
HDMI Output (Optional)
SPO2
(Nellcor/OxySKAN
NIBP
Night mode ECG Recall NIBP Trend
ECG
TEMPERATURE
Salient Features Data Transfer
Sat Seconds™ *Only with Nellcor option
4 channel monitor with 10.4” high resolution color LED display. Intelligent Algorithm for reduction of
ECG (3L/5L), Respiration, Dual Temperature, SpO2 (Nellcor/OxySKAN), nuisance alarms.
NiBP monitoring. Clinician controlled feature.
Adult, Pediatric & Neonatal applications.
High performance in Low Perfusion, Desaturation & Physiologic Shock conditions.
168 hours of Graphical & Tabular trends.
Arrhythmia & ST analysis.
*SatSeconds™ alarm management to reduce false alarms.
500 NiBP trend readings,ECG & Arrhythmia recall, 50 Patient alarm recall. Anti-theft lock
Anti-theft lock.
Technical Specification
DISPLAY NIBP
Size : 10.4” TFT/LED display (800X600) Method : Oscillometric
Trace Speed : 6.25/12.5/25/50 mm/sec Display : Systolic, Diastolic and Mean
Waveform : 4 waveform display Modes : Manual, Auto and Stat
4 standard +One(Applicable when ST is Auto mode intervals of 2, 3, 4, 5, 10, 15, 30, 60,
enabled) and two user selectable formats. 90, 120, 240 & 360 min
Patient Modes : Adult, Pediatric & Neonate Unit : mmHg or kPa
Range : 20-260 mmHg
ECG 3/5L Accuracy : ± 5 mmHg Std Deviation
Input : Isolated 3/5 leads. Protected against
Defibrillation and Electrosurgery
Arrhythmia detection & ST Analysis ALARM
Heart Rate Range : 20-350 bpm Equipment Alarms : Audio (Alarm beep) Visual (Flashing blue LED)
message indication
PR Source : Auto/SpO2/NIBP
Patient Alarms : Audio (Alarm beep)
Leads : 3 Lead (Lead I, II & III) Visual red LED (High priority), Message indication
5 Lead (Lead I, II, III, aVr, aVl, aVf, V) Visual yellow LED (Medium priority),
Message indication
TEMPERATURE (DUAL CHANNEL)
Measurement Range : 1°C-50°C TRENDS
Unit : °C or °F (user selectable) Data Storage : HR/PR, SpO2, Temperature, RR, ST (168 hrs)
Accuracy : ± 0.2 °C NIBP : Last 500 readings in Tabular format
Alarm Recall : Tabular trend display of last 50 patient alarms
RESPIRATION ECG & Arrhythmia
Method : Impedance Pneumography Recall : 240s
Range : 0 -100 breaths/min
GENERAL
Dimensions (H*W*D) : 260 mm *307 mm*150 mm
SpO2
Weight : 3.3 Kg
*NELLCOR™ Saturation (% SpO2 ± 1 SD)
Mounting Option : GCX option and Rail option
SpO2 Measurement : 1-100%
Range USB : Optional WiFi communication with CNS;
Software upload/upgrade, Trend download,
SpO2 Accuracy : ± 2 digits (Below 70% unspecified)
Monitor setting download/upload
Pulse Rate Range : 20 to 250 BPM
LAN : Wired Communication with SKANRAY CNS
PR Accuracy : ± 3 BPM Slave Display : HDMI output (Optional)
OXYSKAN
SpO2 Measurement : 1-100% UNIVERSAL POWER SUPPLY
Range
Voltage : 100-240V AC ± 10%
SpO2 Accuracy : ± 2 digits (Below 70% unspecified) 50/60Hz ± 5%
Indicators : Amber LED - Mains ON
Pulse Rate Range : 20 to 200 BPM ± 3 BPM Green LED - Monitor ON
200 to 250 BPM ± 5 BPM Amber LED OFF and Green LED ON - Running on
battery mode
Battery Type : Lithium ion
Charging Time(min) : 6 hrs/2.2 Ah
Backup Time : 2 hrs back-up time for fully charged and
maintained 25° C (Standard)
*Nellcor™ & Satseconds™ is owned by ‘NELLCOR PURITAN BENNETT LLC’
Skanray Technologies Limited
Regd Office & Technology Division:
# 15-17, Hebbal Industrial Area, Mysore-570 016, Karnataka, INDIA, Tel: +91 821 2415559
Healthcare Division:
# 360, KIADB Industrial Area, Mysore-570 018, Karnataka, INDIA, Tel: +91 821 2407000
Customer Interaction Centre:
Toll Free: 1800-425-7002 | email:
[email protected]/
[email protected] web: www.skanray.com
AMSTERDAM | BOLOGNA | MEXICO CITY | MICHIGAN | MYSURU | SAO PAULO | SUZHOU
Skanray continuously upgrades its technology, product performance and safety features. Pictures and specifications featured in this catalogue are only indicative.
Please refer to the commercial offer document for specifications and performance.
CIN: U72200KA2007PLC041774 3-89-020-0034-03_Rev 1