Corrections to the Saudi Code for Residential Buildings (1102 - 1101 SBC* )

date of publication Update M Item number Type of procedure

amendment 317 1
Adding fire extinguishers as one of the fire prevention and protection requirements for residential buildings (category 3R).

Delete 1.2.2A3 2
Net height of residential buildings (class 3R).

Clause (1.2.3A3) regarding the maximum limit


For the length of the sea. amendment 1.2.3A3 3

6.1A3 4
03/12/1443 AH Clause (6.1A3) regarding column layout. amendment

Spelling of the horizon

6.2A3 5
Clause (6.2A3) regarding the column section size from (cm25) to (cm20). amendment

10/18/2021 AD

Delete 6.2.3A3 6
Clause (6.2.3A3) regarding secondary column requirements.

For rectangular columns. 604.1 7


Y Clause (604.1) regarding the dimensions of the cross-section amendment

Clause (604.2) regarding the distance between side pillars. Delete 604.2 8
Machine Translated by Google

Clause (707.10.1) regarding the minimum reinforcement ratio and adding a sub-clause (707.10.1.1) regarding the
amendment 707.10.1 9

minimum reinforcement ratio for shallow, one-way foundations.

amendment 10 707.11.5.2
Clause (707.11.5.2) regarding the distance of rebar in the separate rules.

g.(For the maximum distance between the grooved bending reinforcement Clause 508.2.4 amendment 508.2.4 11

For the distance between reinforcing steel bars required in ÿ Clause (508.2.5) regarding the maximum limit
amendment 508.2.5 12
03/12/1443 AH Clause (506.2.7).

Spelling of the horizon

Clause (508.4.3) regarding maximum spacing in amendment 508.4.3 13


solid slabs.
10/18/2021 AD

Clause (4.1.2A5) regarding the minimum nerve width. amendment 4.1.2A5 14

Clause (9.1A5) regarding the thickness of the solid slab located between the nerves. amendment 9.1A5 15

Clause (4.1.2B5) regarding the total thickness of reinforced concrete slabs and adding a sub-clause (5B4.1.2.1)
amendment 4.1.2B5 16

ÿ Clause (8.2.3B5) regarding the maximum limit


For the distance between the reinforcing steel bars in the slabs
amendment 17 8.2.3B5
Solid concrete.
Machine Translated by Google

Clause (10.1.2B5) regarding the minimum nerve width. amendment 18 10.1.2B5

03/12/1443 AH amendment 19 10.2.2B5


Clause (10.2.2B5) regarding nerve systems with structural fillings.

Spelling of the horizon

amendment 20 10.3.1B5
Clause (10.3.1B5) regarding nerve systems with other fillings.
10/18/2021 AD

Unifying clause (3.5.5D3) in terms of wording between requirements and requirements. amendment 3.5.5D3 21

)IRC). 22 1305.1.2
Y Clause (1305.1.2) in terms of wording according to the basic code reference amendment

04/28/1445 AH
Table
Spelling of the horizon Addition of specification (60227 IEC SASO) addition 23
C-52-1-1
2023/11/12

07/12/1445 AH

Delete 24 V9 PART
Spelling of the horizon
American Electrical Part Guidelines (NFPA)

2024/01/24

rush version is up to date. lct t


The code was in PDF format before the update date, please redo it again to ensure your current (And if it happens The requirements are the requirements(Application * This update includes all versions of the code
and Spray boards

2  
3  
4  
6  
date  of  publication
1  
M  Item  number  Type  of  procedure
Update
7  
8  
5  
Corrections  to  the  Saudi
12  
15  
11  
9  
13  
16  
14  
10  707.11.5.2  
amendment
amendment
Clause  (4.1.2B5)  regarding  the  total  thickness  o
21  
23  
amendment
3.5.5D3
addition
19  10.2.2B5
Clause  (1305.1.2)  in  terms  of  wording  according  to  the  basic  code