D
S COLUMN DETAIL
D
3 4 6 7 4 NOT DRAWN TO SCALE
8200 4-16 mm WITH 2-12 mm ALTERNATE
MAIN VERTICAL BARS
2.75m 4.05m 1.35m
C1
1.60m 1.15m 3.10m 2.35m 200 mm x 350 mm
10 mm LATERAL TIES SPACED
1 - 50 mm, 5 - 100 mm, 4 - 150 mm
REST @ 200 mm FROM SLAB TO
F F D
MIDHEIGHT
F2-C2 F2-C2 F2-C2 F2-C2 S TYPICAL FOOTING PLAN DETAIL
D
1.70m
2
2.00m
NOT DRAWN TO SCALE
Elev. 250mm
2.70m
Elev. 250mm
3.25m
4 - 16 mm
E
3.80m
C2
1.55m
200 mm x 250 mm
1.80m
Elev. 200mm
D
1.10m
10 mm LATERAL TIES SPACED
7100
7100
C F1-C2 F1-C2 F1-C2
F2-C2 F2-C2
4-16MM WITH 2-12MM ALTERNATE
1 - 50 mm, 5 - 100 mm, 4 - 150 mm
REST @ 200 mm FROM SLAB TO
MIDHEIGHT
MAIN VERTICAL BARS
3.35m
2.65m
2.15m
2.60m
4 thick CONCRE
NATURAL GRADE LINE HOLLOW BLOCKS
0.95m F2-C2
1.20m
B 0.20m
F2-C2 B 16MM BED BARS
Natural Grade Line
0.30m
F2-C2 0.50m
F2-C2
A 0.70m
F1-C1 F1-C1 0.50m A 0.20 m
3 - 12 mm LONGITUDINAL BARS
WITH 10 mm TRANSVERSE
BARS SPACED AT 300mm O. C.
1.00m STAIR UP 0.40m
3.00m
1.00m
2.50m
WALL FOOTING
S
0.70m
2.85m 1.85m 3.50m FOOTNG DIMENSION
DETAIL SECTIPN
D
8200
S COLUMN FOOTING DETAIL SECTION
D
D
5 SCALE 1:30
3 NOT DRAWN TO SCALE
1 2 3 4 5 6 7 SCHEDULE OF FOOTING
SIZE OF FOOTING REINFORCEMENT BARS EXCAVATION DEPTH
MARK
S
A B C REBARS ALONG A REBARS ALONG B (X)
REMARKS
D
F1 1.20 m 1.20 m 0.40 m 1.20 m CENTER FOOTING
FOUNDATION PLAN 1.40 m 1.20 m 0.40 m
D
F2 1.20 m CANTILEVER FOOTING
1 SCALE 1 : 100
SUBMITTED BY: PROJECT NAME & LOCATION: SHEET CONTENTS: SUBMITTED TO: DATE : SCORE: SHEET NO:
EARL JONELLE L. ORA TWO STOREY RESIDENTIAL
FOUNDATION PLAN
TYPICAL FOOTING DETAIL
ENGR. GLAIDEL CARRERA
S
10/30/2024
FLOOR PLAN
COLUMN FOOTING DETAIL
COLUMN DETAIL
1-5
WALL FOOTING DETAIL