LMG670
Precision Power Analyzer
2
Power Analysis
Two Bandwidths Simultaneously
Single-shot results for narrowband, broadband & harmonics measurements
Powerful Convenient Flexible
7 channels, DualPath, accuracy 0.025 %, Touchscreen, 8,9‘‘ WSVGA display Measuring frequency converters,
DC – 10 MHz, excellent dynamic range (1024x600), remote control via PC, e-machines, transformers, power
µA to kA and mV to kV Gbit Ethernet, DVI/VGA interface electronics, power supplies
A New Generation of Power Analyzers
For decades, the letters “LMG“ have been Besides this spectacular innovation we
synonymous with precision power analysis have also implemented numerous other
technology developed and manufactured improvements – some obvious, some rather
by ZES ZIMMER. The LMG series has con- inconspicuous. We have been exclusively
quered a leading market position thanks dedicated to precision power analysis and
to its precision and reliability. It has sophisticated measurements for decades
spread throughout the most diverse areas and have incorporated the resulting trea-
of the electric and electronic industry – in sure trove of experience into the design of
R&D, quality assurance and compliance the LMG670. It is our ambition to provide
test labs – and serves universities and you with precise and reliable results fast
Dipl.-Ing. Georg Zimmer and Dr. Conrad Zimmer
academies to train future scientists and so you can carry out your measurement Managing Directors
engineers. tasks in an efficient manner! ZES ZIMMER Electronic Systems GmbH
With our new LMG670 we not only enable
you to cope with increased requirements
and latest power electronics innovations –
we allow you to put yourself and your prod-
ucts squarely in front of the competition.
In times of beginning scarcity of conven-
tional fuels, power analysis plays an
important and growing role, especially
when it comes to increasing efficiency and
minimizing consumption. Wherever elec-
trical energy is turned into motion, losses
get scrutinized ever more critically. Ineffi-
cient means of speed control are replaced
by variable frequency drives (VFD), and
electro mobility in all its varieties is gain-
ing momentum. ZES ZIMMER has attended
to typical questions in this area und came
up with a groundbreaking innovation: our
DualPath architecture makes possible – for
the first time in history – concurrent and
precise analysis of both the torque-rele-
vant fundamental and the full spectrum
for optimization of overall efficiency.
With the highest density of power measurement channels per chassis and an unsurpassed
combination of precision and bandwidth the LMG670 is the instrument of choice for
sophisticated efficiency measurements in complex electrical systems.
Technical Data (Summary)
± (% of measured value + % of maximum peak value)
Accuracy
A1 channel 0.05 Hz ... 45 Hz 50 kHz ... 100 kHz ...
DC 45 Hz ... 65 Hz 3 kHz ... 10 kHz 10 kHz ... 50 kHz 500 kHz...1 MHz 1 MHz ... 2 MHz 2 MHz ... 10 MHz
65 Hz ... 3 kHz 100 kHz 500 kHz
Voltage U* 0.02+0.08 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.5+1.0 0.5+1.0 f/1 MHz*1.5 + f/1 MHz*1.5
Voltage USENSOR 0.02+0.08 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.4+0.8 0.4+0.8 f/1 MHz*0.7 + f/1 MHz*1.5
Current I* f/1 MHz*1.0 +
0.02+0.08 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.5+1.0 0.5+1.0 -
5 mA...5 A f/1 MHz*2.0
Current I*
0.02+0.081) 0.015+0.033) 0.01+0.023) 0.1+0.23) 0.3+0.63) f/100 kHz*0.8 + f/100 kHz*1.23) - - -
10 A...32 A
Current ISENSOR 0.02+0.08 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.4+0.8 0.4+0.8 f/1 MHz*0.7 + f/1 MHz*1.5
Power U*/ I* f/1 MHz*2.0 +
0.032+0.08 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.8+1.0 0.8+1.0 -
5 mA...5 A f/1 MHz*1.8
Power U*/ I* f/100 kHz*0.8 + f/100 kHz*1.0 +
0.032+0.082) 0.024+0.034) 0.015+0.014) 0.104+0.134) 0.4+0.54) - - -
10 A...32 A f/100 kHz*0.84) f/100 kHz*1.14)
Power U*/ ISENSOR 0.032+0.08 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.72+0.9 0.72+0.9 f/1 MHz*1.8 + f/1 MHz*1.5
Power USENSOR / I* f/1 MHz*1.4 +
0.032+0.08 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.72+0.9 0.72+0.9 -
5 mA...5 A f/1 MHz*1.8
Power USENSOR / I* f/100 kHz*0.8 + f/100 kHz*1.0 +
0,.032+0.082) 0.024+0.034) 0.015+0.014) 0.104+0.134) 0.4+0.54) - - -
10 A...32 A f/100 kHz*0.84) f/100 kHz*1.04)
Power USENSOR / ISENSOR 0.032+0.08 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.64+0.8 0.64+0.8 f/1 MHz*1.1 + f/1 MHz*1.5
± (% of measured value + % of maximum peak value)
Accuracy
B1 channel 0,05 Hz ... 45 Hz 100 kHz ...
DC 45 Hz ... 65 Hz 1 kHz ... 5 kHz 5 kHz ... 20 kHz 20 kHz ... 100 kHz
65 Hz ... 1 kHz 500 kHz
f/1 00 kHz*0.8 +
Voltage U* 0.1+0.1 0.1+0.1 0.05+0.05 0.2+0.2 0.3+0.4 0.4+0.8
f/1 00 kHz*1.2
Current I* 5 mA...5 A f/1 00 kHz*0.8 +
0.1+0.1 0,.1+0.1 0.05+0.05 0.2+0.2 0.3+0.4 0.4+0.8
Current ISENSOR f/1 00 kHz*1.2
Current I* f/1 00 kHz*2.0 +
0.1+0.11) 0.1+0.13) 0.05+0.053) 0.2+0.23) 0.6+1.23) 1.5+1.53)
10 A...32 A Bereich f/1 00 kHz*2.03)
Power U*/ I*
f/1 00 kHz*1.28 +
5 mA...5 A 0.16+0.1 0.16+0.1 0.07+0.04 0.32+0.2 0.48+0.4 0.64+0.8
f/1 00 kHz*1.2
Power U*/ ISENSOR
Power U*/ I* f/1 00 kHz*2.24 +
0.16+0.12) 0.16+0.14) 0.07+0.044) 0.32+0.24) 0.72+0.84) 1.52+1.154)
10 A...32 A f/1 00 kHz*1.64)
± (% of measured value + % of maximum peak value)
Accuracy
C1 channel 0,05 Hz ... 45 Hz
DC 45 Hz ... 65 Hz 200 Hz ... 500 Hz 500 Hz ... 1 kHz 1 kHz ... 2 kHz 2 kHz ... 10 kHz
65 Hz ... 200 Hz
f/1 kHz*1.0 +
Voltage U* 0.1+0.1 0.02+0.05 0.02+0.02 0.05+0.05 0.2+0.1 1.0+0.5
f/1 kHz*1.0
f/1 kHz*1.0 +
Current I* 0.1+0.11) 0.02+0.053) 0.02+0.023) 0.05+0.053) 0.2+0.13) 1.0+0.53)
f/1 kHz*1.03)
f/1 kHz*1.0 +
Current ISENSOR 0.1+0.1 0.02+0.05 0.02+0.02 0.05+0.05 0.2+0.1 1.0+0.5
f/1 kHz*1.0
f/1 kHz*1.6 +
Power 0.16+0.12) 0.032+0.054) 0.03+0.014) 0.08+0.054) 0.32+0.14) 1.6+0.54)
f/1 kHz*1.04)
1. Sinusoidal voltages and currents 6. 0 ≤ |λ| ≤ 1 (power factor)
2. Ambient temperature (23±3) °C 7. Current and voltage
3. Warm-up time 1 h 10 % ... 110 % of nominal value
Accuracies valid for:
4. The upper range value is defined by the maximum peak value. 8. Adjustment carried out at 23 °C
5. The upper power range value is the product of upper voltage range value and 9. Calibration interval 12 months
upper current range value.
All other values are calculated from current, voltage and power. Accuracy resp. error limits are derivated according to context
Other values
(e.g. S = I * U, ΔS / S = ΔI / I + ΔU / U).
1) 2) 3) 4)
only valid in range 10 ... 32 A:
1)
additional uncertainty ± 50 µA * Itrms2 2)
additional uncertainty ± 50 µA * Itrms2 * Utrms 3)
additional uncertainty ±30 µA * Itrms2 4)
additional uncertainty ±30 µA * Itrms2 * Utrms
A2 A2 A2 A2
Voltage measuring ranges U*
Nominal value (V) 3 6 12.5 25 60 130 250 400 600 1000
Max. trms value (V) 3.3 6.6 13.8 27.5 66 136 270 440 660 1000
Max. peak value (V) 6 12 25 50 100 200 400 800 1600 3200
Overload protection 1000 V + 10 % permanently, 1500 V for 1 s
Input impedance 4.59 MΩ, 3 pF
Earth capacitance 90 pF
Current measuring ranges I*
Nominal value (A) 0.005 0.01 0.02 0.04 0.08 0.15 0.3 0.6 1.2 2.5 5 10 20 32
Max. trms value (A) 0.0055 0.011 0.022 0.044 0.088 0.165 0.33 0.66 1.32 2.75 5.5 11 22 32
Max. peak value (A) 0.014 0.028 0.056 0.112 0.224 0.469 0.938 1.875 3.75 7.5 15 30 60 120
Input impedance ca. 2.2 Ω ca. 600 mΩ ca. 80 mΩ ca. 20 mΩ ca. 10 mΩ
Overload protection permanent (A) LMG in operation 10 A LMG in operation 32 A
Overload protection short-time (A) 150 A for 10 ms
Earth capacitance 90 pF
Sensor inputs USENSOR, ISENSOR
Nominal value (V) 0.03 0.06 0.12 0.25 0.5 1 2 4
Max. trms value (V) 0.033 0.066 0.132 0.275 0.55 1,1 2,2 4,4
Max. peak value (V) 0.0977 0.1953 0.3906 0.7813 1.563 3.125 6.25 12.5
Overload protection 100 V permanently, 250 V for 1 s
Input impedance 100 kΩ, 34 pF
Earth capacitance 90 pF
All current and voltage inputs are isolated against each other, against remaining electronics and against earth
Isolation
Max. 1000 V / CAT III resp. 600 V / CAT IV
Measurements are synchronized on the signal period. The period is determined based on „line“, „external“, u(t) or i(t), in combination
Synchronization with configurable filters. Therefore very stable readings, especially with PWM controlled frequency converters and amplitude modulated
electronic loads.
Scope function Graphical display of sample values over time
Plot function Two time (trend-) diagrams of max. 8 parameters, max. resolution 30 ms
External graphics interface (L6-OPT-DVI) VGA/DVI interface for external screen output
2 fast analog inputs (150 kS/s, 16 bit, BNC)
8 analog inputs (100 S/s, 16 bit, D-Sub:DE-09)
32 analog outputs (output per cycle, 14 bit, D-Sub: DA-15 & DB-25)
Process signal interface (L6-OPT-PSI)
8 switching outputs (6 switches with 2 connections each and 2 switching outputs with common negative, D-Sub: DB-25)
8 switching inputs (150 kS / s, in two groups 4 inputs each with common ground, D-Sub: DB-25)
Speed-/torque-/frequency inputs (150 kS/s, D-Sub: DA-15)
Star-delta conversion (L6-OPT-SDC) Conversion of line voltages to phase voltages and computation of resulting power
Harmonics at device level (L6-OPT-HRM) Harmonics and interharmonics up to max. 400. order (2,000. order with interharmonics)
Flicker (L6-OPT-FLK) According to EN 61000-4-15
LMG-Control LMG600 expansion software, basic module for remote configuration and operation via PC
TEST-CE61K LMG600 software for conformity tests according to EN61000 for harmonics and flicker
Miscellaneous
Dimensions Table-top version for 7 slots: (WxHxD) 433 mm x 177 mm x 590 mm, 19” version for 7 slots: (WxHxD) 84 HP x 4 RU x 590 mm
Weight Depending on installed options: max. 18.5 kg
Protection class EN 61010 (IEC 61010, VDE 0411), protection class I / IP20 in accordance with EN 60529
Electromagnetic compatibility EN 61326
en 05/2014
Temperature 0 ... 40 °C (operation) / -20 ... 50 °C (storage)
Climatic category Normal environmental conditions according to EN 61010
Line input 100 ... 230 V, 47 ... 63 Hz, max. 400 W