3'-6"

3'-9"

3'-6"
TOILET TOILET
3'-6" TOILET 3'-6"
3'-9"
GENERAL NOTES-
1. ALL DIMENSIONS ARE IN FEET & INCHES.
ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED,
BALCONY 5'

DO NOT SCALE THE DRAWING.

BALCONY 5'
2. ALL DIMENSIONS, LEVELS & CUTOUTS SHALL BE CHECKED &

BALCONY 5'
CORRECTED WITH ARCHITECTURAL PLANS
3. MIX CONCRETE SHALL BE M-20
4. CONCRETE SHALL BE WEIGH/VOLUME BATCHED, MACHINE
KITCHEN
KITCHEN GENERAL NOTES- MIXED & MECHANICALLY VIBRATED TO ASSURE FULL
COMPACTION.
KITCHEN 1. ALL DIMENSIONS ARE IN FEET & INCHES. 5. H. Y. S. D. BARS SHALL BE Fe - 500 (TESTED)
6. ONLY `VALID FOR CONSTRUCTION' DRG. SHALL BE USED
BEDROOM ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED,
BEDROOM BEDROOM FOR EXECUTION OF WORK.
DO NOT SCALE THE DRAWING. 7. ALL THE R.C.C./STRUCTURAL WORK SHALL BE EXECUTED
STRICTLY UNDER COMPETENT TECHNICAL SUPERVISION
2. ALL DIMENSIONS, LEVELS & CUTOUTS SHALL BE CHECKED & SEPARATELY PROVIDED BY THE OWNER
CORRECTED WITH ARCHITECTURAL PLANS Shorter side 8. CLEAR COVER TO STEEL -
COLUMNS & SHEAR WALLS - 1.5" /40 mm TO STIRRUPS
3. MIX CONCRETE SHALL BE M-20 FOOTINGS - 2" /50 mm(BOTTOM) 2"/50mm -(SIDE & TOP)
4'-6" 4'-6" 4. CONCRETE SHALL BE WEIGH/VOLUME BATCHED, MACHINE BEAMS - 1.5"/35 mm (BOTTOM) 1"/25mm - (SIDE & TOP)
SLAB - 1.5"/35 mm (BOTTOM & TOP)
MIXED & MECHANICALLY VIBRATED TO ASSURE FULL 9. LAPS SHALL BE PROVIDED ONLY AT APPROVED LOCATIONS

Longer side
COMPACTION. & SHOULD BE STAGGERED.
LAP LENGTH - 60 x BAR DIA.
5. H. Y. S. D. BARS SHALL BE Fe - 500 (TESTED) 10. FOR ALL COLUMNS HAVING EIGHT OR MORE BARS,
6. ONLY `VALID FOR CONSTRUCTION' DRG. SHALL BE USED

4'-6"
MASTER RING TO BE PROVIDED.

3'-9"
4'-6"
11. ANY DISCREPANCY FOUND BETWEEN STRUCTURAL
FOR EXECUTION OF WORK. & ARCHITECTURAL DRAWING, SHOULD BE
7. ALL THE R.C.C./STRUCTURAL WORK SHALL BE EXECUTED BROUGHT TO OUR NOTICE BEFORE THE WORK IS

STRICTLY UNDER COMPETENT TECHNICAL SUPERVISION 6" EXECUTED.


12. APPLICATION OF OIL TO THE SHUTTERING IS NOT ALLOWED.

BATH SEPARATELY PROVIDED BY THE OWNER 13. QUALITY WORK PROCEDURES & SAFETY AT SITE ARE THE
BATH 3'-9" BATH 8. CLEAR COVER TO STEEL - RESPONSIBILITIES SOLELY LIE WITH CONTRACTOR / BUILDER
/ OWNER. WE SHALL NOT BE RESPONSIBLE FOR POOR
COLUMNS & SHEAR WALLS - 1.5" /40 mm TO STIRRUPS QUALITY OF STEEL, CONCRETE, CURING, SHUTTERING OR
INCORRECT CONSTRUCTION PROCEDURE.
FOOTINGS - 2" /50 mm(BOTTOM) 2"/50mm -(SIDE & TOP) 14. REFER ARCHITECTURAL DRAWINGS WHERE-EVER NECESSARY.
BEAMS - 1.5"/35 mm (BOTTOM) 1"/25mm - (SIDE & TOP) 15. S. B. C. OF SOIL IS ASSUMED 400 KN / SQM
3'-9" SLAB - 1.5"/35 mm (BOTTOM & TOP) (TO BE ACERTAINED).
16. DESIGN IS VALID FOR GROUND +1 FLOOR ONLY
HALL 9. LAPS SHALL BE PROVIDED ONLY AT APPROVED LOCATIONS (AS PERARCHITECTURAL DRAWING).
HALL W.C & SHOULD BE STAGGERED. 17. DEPTH OF EXCAVATION 1.2 M
W.C HALL
W.C LAP LENGTH - 60 x BAR DIA.

3'-9"
10. FOR ALL COLUMNS HAVING EIGHT OR MORE BARS,
MASTER RING TO BE PROVIDED.
11. ANY DISCREPANCY FOUND BETWEEN STRUCTURAL
& ARCHITECTURAL DRAWING, SHOULD BE
BROUGHT TO OUR NOTICE BEFORE THE WORK IS
EXECUTED.
12. APPLICATION OF OIL TO THE SHUTTERING IS NOT ALLOWED.
REV NO:-
13. QUALITY WORK PROCEDURES & SAFETY AT SITE ARE THE

3'-9"

3'-9"
4'-0"

3"
RESPONSIBILITIES SOLELY LIE WITH CONTRACTOR / BUILDER R-00
BALCONY 4'

/ OWNER. WE SHALL NOT BE RESPONSIBLE FOR POOR

BALCONY 4'
BEDROOM

BALCONY 4'
BEDROOM QUALITY OF STEEL, CONCRETE, CURING, SHUTTERING OR
BEDROOM INCORRECT CONSTRUCTION PROCEDURE.
3'-9" 4'-0" 3'-9" 14. REFER ARCHITECTURAL DRAWINGS WHERE-EVER NECESSARY.
15. S. B. C. OF SOIL IS ASSUMED 400 KN / SQM
CLIENT : MR.KATE
UP 4'-0" UP (TO BE ACERTAINED).
UP 3'-6" 16. DESIGN IS VALID FOR GROUND +1 FLOOR ONLY TERRACE LEVEL SLAB
2
ARCHITECT/ENGINEER : AR. POTDAR SAHEB
(AS PERARCHITECTURAL DRAWING). FIRST
PORCH 17. DEPTH OF EXCAVATION 1.2 M FIRST FLOOR SLAB
PORCH

4'-0"
1

3'-6"
GROUND

6"
KEY ELEVATION SHOWING NUMBER OF FLOORS
12"

D
CONSIDERED FOR STRUCTURAL DESIGN
6" SUNIL NIMBALKAR & ASSOCIATES
P.C.C. TYPICAL STIRRUP DETAILS
3'-6" 3'-9" 1:4:8, 5" THK.
(PROVIDE 135° HOOK WITH 3" EXTENSION)
SUNIL NIMBALKAR & ASSOCIATES
3'-6"

3'-9"
REV NO:-

R-00

TERRACE LEVEL SLAB


2
CLIENT : MR.KATE
FIRST
FIRST FLOOR SLAB ARCHITECT/ENGINEER : AR. POTDAR SAHEB
1
GROUND

KEY ELEVATION SHOWING NUMBER OF FLOORS


CONSIDERED FOR STRUCTURAL DESIGN
SUNIL NIMBALKAR & ASSOCIATES

SUNIL NIMBALKAR & ASSOCIATES

TOILET
BALCONY 5'

KITCHEN

BEDROOM

BATH

HALL
W.C
BALCONY 4'

BEDROOM

UP

PORCH