6FM100/12Volt 100Ah
Solar GEL Series Batteries are specially designed for telecom use with
12+ years design life in float service. Byadopting a new AGM separator and
centralised venting system, the battery can be installed in any position while
manintaning high reliability.
Heavy Duty Grid Negative........Lead
Mechanized assembly Terminal........Copper
Non-spillable construction Positive........Lead dioxide
High Reliability and Stability Electrolyte........Sulfuric acid
Sealed and Maintenance-free Separator........Fiber glass
Long Life and low self-discharge design Safety Valve........EPDR
Container........ABS(UL94-HB) / (UL94-V0)
Nominal Voltage 12V
Ba�ery Model Rated capacity (10Hour rate) 100Ah
Cells Per ba�ery 6
Length Width Height Total Height
Dimension
331mm 173mm 213mm 220mm
Approx Weight 27.00 Kg
Internal Resistance Full charged at 25℃(77℉): Approx 5.0mΩ
Max.discharge current 800A(5s)
Floa�ng design life @ 25℃ (77℉) 12 years
10Hour rate(10A/10.8V) 5Hour rate(17A/10.8V) 3Hour rate(25A/10.5V) 1Hour rate(55A/10.5V)
Capacity @ 25℃ (77℉)
100Ah 85Ah 75Ah 55Ah
40℃ (104℉) 25℃ (77℉) 0℃ (32℉) -15℃(5℉)
Capacity affected by Temp(10 HR)
102% 100% 85% 65%
A�er 3 months storage A�er 6 months storage A�er 12 months storage
Self Discharge @ 25℃ (77℉)
93% 84% 65%
Cycle Use 14.5-14.9V (Ini�al charging current less than 30.0A)
Charge method @ 25℃ (77℉)
Float Use 13.6-13.8V
3
3
21 3
218
8.5
20
9
20
173
M8
331 17.5
F.V / TIME 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
A 360.00 220.00 175.00 115.00 60.50 35.00 26.00 21.00 17.54 11.58 11.00 5.70
9.60V
W 3816.00 2336.40 1872.50 1242.00 659.45 381.50 286.00 231.00 192.96 128.57 122.10 64.13
A 330.00 211.00 160.83 109.17 60.00 33.58 25.50 20.00 17.21 11.40 10.50 5.60
10.20V
W 3597.00 2342.10 1793.29 1228.13 675.00 379.49 288.15 227.00 195.31 129.39 119.18 63.56
A 306.04 201.66 150.00 105.83 58.00 32.92 25.00 19.00 17.00 11.25 10.30 5.53
10.50V
W 3366.46 2268.68 1695.00 1206.50 661.20 376.90 286.25 218.50 195.50 129.38 118.45 63.60
A 278.67 199.92 140.00 101.00 57.00 32.08 24.50 18.67 16.25 10.96 10.00 5.46
10.80V
W 3065.33 2279.09 1603.00 1166.55 658.35 370.56 284.20 217.47 189.31 127.66 116.50 63.61
A 241.00 190.00 130.00 94.00 55.00 31.25 23.50 18.33 15.54 10.67 9.75 5.40
11.10V
W 2723.30 2194.50 1508.00 1099.80 643.50 365.63 276.13 216.33 183.39 125.87 115.05 63.72
Note: The above datas are average values. (Edition 2017-11)
Page 1 of 2
6FM100/12Volt 100Ah
120
2.16/6.48/13.0 100
Voltage (V)
1.85/5.55/11.1 80
1.80/5.40/10.8
Capacity(%)
0.25C 0.20C 0.17C 0.12C 0.1C 60
1.75/5.25/10.5 100%DOD 50%DOD 30%DOD
0.05C
0.55C 0.40C
1.70/5.10/10.2 40
1.65/4.95/9.90
3C 2C 1C 20
1.60/4.80/9.60
0
7min 15min 27min 1h 2h 3h 4h 5h 8h 10h 20h 200 400 600
0 800 1000 1200 1400
Number of cycles (cycles)
Discharge time
Charged
( V / 12V )
Volume
Current
Voltage
( V / CE )
( V / 8V )
( V / 6V )
( V / 4V )
(%) (XCA) (V)
140
15.6 10.4 7.8 5.2 2.6
120 0.25
15.0 Charged Volume
15.0 10.0 7.5 5.0 2.5 Cyc 100
le U 0.20
se 14.0 Charge Voltage
14.4 9.6 7.2 4.8 2.4 80
0.15
13.0
Stand
by Use 60
13.8 9.2 6.9 4.6 2.3
0.10
40 12.0
13.2 8.8 6.6 4.4 2.2
20 0.05
11.0
Charging Current
-10 0 10 20 30 40 50 60 0 0
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature() Charging time (hours)
11 0
100
2.30V/Cell
5 90
Life (years)
Capacity (%)
80
1
70
60
40℃ 30℃ 20℃
50
0 40
10 20 30 40 50
0 2 4 6 8 10 12 14 16 18 20
Temperatura() Storage time: months
120 15 7.5 5.0 120 0.24
Charge Volume
100 14 7.0 4.7 100 0.20
Charge Voltage
Charge Voltage (V)
Charge Currient (CA)
80 13 6.5 4.3 80 0.16
Charge Volume (%)
① Discharge
Capacity (%)
100% (0.05 CA*20h)
50% (0.05 CA*10h)
12 6.0 4.0 ② Charge 60 0.12
60 Charge Voltaje 2.275V /cell
Testing conditions: floating voltage: 2.27 to 2.30V /cell Charge Current 0.1 CA
③ Temperature 25℃
Ambient temperature: 25 () 11 5.5 3.7 40 0.08
40
10 5.0 3.3 20 0.04
20 Charge Current
9 4.5 3.0 0 0
0 0 2 4 6 8 10 12 14 16 18 20 24 28
1 2 3
Charge Time (h)
Life (years)
Note: The above datas are average values. (Edition 2017-11)