i.Profiler® plus by ZEISS.

The 4-in-1compact system – ocular wavefront aberrometer,


autorefractometer, ATLAS corneal topographer and keratometer.

ȴȴ Your link to innovative i.Scription® technology


ȴȴ All-in-one system with easy-to-use touch screen
ȴȴ Ocular wavefront measurement up to 7th order Zernike aberration
ȴȴ Measures both eyes automatically in approximately 30 seconds

See more. Live more.


ZEISS precision lenses.

A leader in precision optics since 1846.


i.Profiler® plus by ZEISS.

Ocular wavefront and corneal topography. Easy accurate eye measurement.


i.Profiler combines a high-resolution Hartmann-Shack wave-
® plus
The fully automated measurement procedure, with touch screen
front sensor with the proven ATLAS corneal topographer in a control, enables all measurements of both eyes in
single compact system. approximatly 30 seconds.

Access to i.Scription® technology by ZEISS. Advanced features for faster workflow.


i.Scription technology combines the subjective refraction with
®
Clearly structured functions enable capture, evaluation, pre-
ocular wavefront aberrometry data, creating an individualized sentation and analysis of four measurement modalities: ocular
prescription to 1/100th of a diopter. Integrated with a ZEISS wavefront aberrometer, autorefractometer, ATLAS corneal
high precision lens, i.Scription® technology offers better night topographer and keratometer.
vision, as well as improved color and contrast perception.

Technical Data Wavefront

Measuring range, sphere: –20 D to +20 D

Measuring range, cylinder: 0 D to +8 D

Axis: 0° – 180°

Measuring surface: 2.0 mm to 7.0 mm (three zones)

No. of measuring points: up to 1500

Method: Hartmann-Shack

Reference wavelength:1 555 nm according to ISO 24157


2D ocular wavefront map.
Technical Data Corneal Topography

No. of rings: 22 (18 complete rings)

No. of measuring points: 3,425

Detected corneal surface


dia. 0.75 mm to 9.4 mm
at 42.125 D:

Diopters: measurement range 25 to 65 D

Accuracy: ± 0.05 D (± 0.01 mm)

Reproducibility: ± 0.10 D (± 0.02 mm)


EN_20_010_7138I

Type A: according to ISO 19980


1 Reference wavelength for the interpretation of refractive errors (referring to