EO Gas Sterilizer (General) Email
EO Gas Sterilizer (General) Email
2 HANSHIN
www.hanshinmed.co.kr / www.eurohanshin.com
Product Mix
HANSHIN 3
Ethylene Oxide Gas Mixture type Sterilizer
Technical Advantages of HANSHIN’s EO Gas Sterilizers
Sterilization System
▣
User can select a proper cycle program for an optimum performance of sterilization among 4 kinds of basic cycle programs
comprised of high(56℃) and low(38℃) temperature cycle and change the parameters of basic cycle programs at user’s
pleasure according to the material to be sterilized or sterilization condition. Therefore the sterilization is effective and convenient.
These sterilizers use 3 kinds of EO gas mixture as sterilant that the inert gases, the freon and the carbon dioxide(CO2) gases,
are mixed with Ethylene Oxide respectively, thus user can select the sterilant widely and easily.
▣
The aeration cycle is a practical cycle for the items required the additional aeration even though aerated in the basic or user’s
cycle, and the items processed in the sterilizer without aeration function.
▣
The sterilization temperature in the chamber is sustained using the jacket water heated by the built-in heater and the jacket water is
circulated by the pump for maintaining the temperature distribution uniformly, hence the effectiveness of sterilization is excellent.
Control System
▣
The controller with a microprocessor carries on a sterilization cycle automatically and controls LCD displaying, self diagnosis
function, printing the record. Especially the devices with these functions are integrated as a compact component and the
controller can be changed with a normal one rapidly and easily when a trouble has occurred in the controller. This allows user
to operate and maintain the sterilizer efficiently and conveniently.
▣
The self-diagnosis program detects the operation errors during progressing a cycle and generates an warning alarm
automatically. The cycle in progress is aborted automatically when before discharging gas into the chamber and the sterilizer
returns to the initial state if you press the <START/STOP> key (press the <STOP> button for the touch screen type). But when
after discharging gas into the chamber, the cycle in progress is aborted and the gas in the chamber is exhausted automatically
through the vent and aerate phase and the cycle is completed safely. The aeration phase can be stopped during execution
using the <START/STOP> key (using the <STOP> button for the touch screen type).
▣
The precise humidity control is the important requirement because the sterilizing effect is reduced if the humidity is insufficient in
the chamber. The humidity is formed (40~80%RH) by the steam introduced in the chamber, that the steam is generated in the
vaporizer using water injected from the outside.
▣
If the electric power has suddenly cut off during progressing a cycle, the cycle is retained at the stopped process and is
progressed from that process when the electric power has restored. This is possible that the controller stores the cycle
informations at the stopped process during power failure and is an outstanding function for maintaining the continuity of a cycle
in progress.
4 HANSHIN
Vacuum System
▣
The vacuum pump installed in the sterilizer is different in the sterilizer model respectively as the waterring type (HS-
700EO/5025EO, HG-5025EOT) and the diaphragm type (HS-4085EO/3241EO), and all the pumps have excellent operating
performance such as the powerful exhaust capability, durability, airtightness, full oilless operation and low noise etc.
▣
The vacuum leak test is to check whether the chamber is leaking or not and user should carry on this test once everyday
before sterilizing. If the test result is failed, user must stop operation of the sterilizer and repair after investigating the cause
thoroughly because the gas in the chamber is leaked out to the outside and it may cause human injury and an
environmental contamination.
Ventilation System
▣
The gas in the chamber is exhausted during the vent and aeration process to the outside of building through the ventilation
duct generally, but the EO gas sterilizers of HANSHIN are designed to drain the residual gas mixed with water to the prepared
drainage for the safety of user and for protecting environment. The ethylene oxide is dissolved completely in the 10℃ water.
▣
These sterilizers are equipped with a bacteria retentive high efficiency air filter that is able to filter the particles greater than
0.3㎛ at least 99.999% and the highly filtered air can be introduced into the chamber during the vent and aeration process,
this prevents the sterilized items from recontamination by the air-borne bacteria in the chamber.
▣
When changing an exhausted gas cylinder, the residual gases in the piping or pressure regulator are removed automatically by
operation of the control program for protecting the user’s health and preventing environment of workplace from contamination.
▣
The built-in panel printer prints out the cycle performance record that is able to check and analyze the results of a executed cycle.
The cycle performance record includes the serial number of sterilizer, the year/month/date of cycle start, the set parameters
(exposure temperature and time, adjusting temperature, aeration time, pressure), the execution result data of each cycle phase
(start and completion time, temperature and pressure), the maximum/minimum value of pressure and temperature during
progressing a cycle, the required time of each cycle phase, the error code occurred during progressing a cycle and other useable
informations (total required time of a executed cycle, total number of the executed cycle times and gas supply times etc.)
HANSHIN 5
EO Gas Mixture type Sterilizer_Touch Screen LCD Monitor type
HS- 7 0 0EO
Ubiquitous EO Gas Sterilizer
- Network Monitoring System
Front Side
Network System
6 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and is used for sterilizing the materials
which are unstable under high temperature or items to which the steam sterilization is inapplicable for the structural reasons. Therefore it is
essential for the medical institutions where using the precise and delicate medical devices to use this kind of low temperature sterilizer.
▶ The large capacity of chamber allows user to sterilize conveniently many medical devices and instruments or volumed loads at once.
▶ All the sterilizing cycle is progressing automatically by the controller with a microprocessor, and the controller is designed to separate from the
sterilizer easily for prompt servicing by the supplier or manufacturer. User is able to operate and control the sterilizer conveniently by one
touching on the touch screen, and monitor the state of operating sterilizer in real time on it.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the touch screen monitor
immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in progress
automatically for safety of workplace.
▶ Two gas cylinders are available in succession automatically by the control program and the problems like a gas leak or cycle stop caused by
changing the gas cylinder can be prevented.
▶ The communication program for multi-user that is supporting the ubiquitous function is provided as an optional feature. Each operation
informations from the sterilizers connected to the network system which is consisted of LAN, DB server and Client are saved and preserved
in the DB server safely by this program, and user can check the required informations in real time conveniently with the client computer any
time, any where.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
HS-700EO
HANSHIN 7
EO Gas Mixture type Sterilizer_Touch Screen LCD Monitor type
HG- 5 0 2 5EOT
Automatic Sliding Door type EO Gas Sterilizer
- Realized the Ergonomic Design for Maximizing Operator’
s Safety and Convenience
Front Side
CYCLE P1 EO/CO2 CYCLE P2 EO/CO2 CYCLE P3 EO/FREON CYCLE P4 EO/FREON VACUUM LEAK TEST
(High Temp.) (Low Temp.) (High Temp.) (Low Temp.)
8 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and is used for
sterilizing the materials which are unstable under high temperature or items to which the steam sterilization is inapplicable for
the structural reasons. Therefore it is essential for the medical institutions where using the precise and delicate medical
devices to use this kind of low temperature sterilizer.
▶ The practical medium sized chamber allows user to sterilize conveniently many medical devices and instruments or bulky loads at once.
▶ The door moves up and down smoothly without any physical force by adopting the automatic vertical sliding system, therefore the
large volume sterilizing is much more safe and convenient than the hinged door type. Moreover it has the advantage of saving the
required space to install the sterilizer.
▶ Two gas cylinders are available in succession automatically by the control program and the problems like a gas leak or cycle stop
caused by changing the gas cylinder can be prevented.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the touch screen
monitor immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in
progress automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
Same as
Gas Mixture N/A
basic cycle
Select one among
Cycle No.
basic cycle
Expos. Temp.
Pressure
Expos. Time
Aeration Time
HG-5025EOT
HANSHIN 9
EO Gas Mixture type Sterilizer_Graphic LCD Monitor type
HS- 7 0 0EO
Large Capacity Standard EO Gas Sterilizer
- Effective Sterilization for Bulky
Bulhy Loads At Once
Front Side
CYCLE No.1 EO/CO2 CYCLE No.2 EO/CO2 CYCLE No.3 EO/FREON CYCLE No.4 EO/FREON CYCLE No.5
(High Temp.) (Low Temp.) (High Temp.) (Low Temp.) (Vacuum Leak Test)
10 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and sterilizes the materials
which are unstable under high temperature and moisture or items to which the steam sterilization is inapplicable for the structural
reasons. Therefore it is essential for the medical institutions where using the precise and delicate medical devices to use this kind of
low temperature sterilizer.
▶ The large capacity of chamber allows user to sterilize conveniently many medical devices and instruments or volumed loads at once.
▶ User can operate and control the sterilizer conveniently by pressing the operation keys arranged on the control panel and can check
the state of a cycle progressing on the message center (LCD monitor).
▶ Two gas cylinders are available in succession automatically by the control program and the problems like a gas leak or cycle stop
caused by changing the gas cylinder can be prevented.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the monitor
immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in progress
automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
Same as
Gas Mixture N/A
basic cycle
Select one among
Cycle No.
basic cycle
Expos. Temp.
Pressure
Expos. Time
Aeration Time
HS-700EO
HANSHIN 11
EO Gas Mixture type Sterilizer_Graphic LCD Monitor type
HS- 5 0 2 5EO
Medium Capacity Standard EO Gas Sterilizer
- Efficient Sterilization for Various Medical Devices At Once
Front Side
CYCLE No.1 EO/CO2 CYCLE No.2 EO/CO2 CYCLE No.3 EO/FREON CYCLE No.4 EO/FREON CYCLE No.5
(High Temp.) (Low Temp.) (High Temp.) (Low Temp.) (Vacuum Leak Test)
12 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and sterilizes the
materials which are unstable under high temperature and moisture or items to which the steam sterilization is inapplicable for the
structural reasons. Therefore it is essential for the medical institutions where using the precise and delicate medical devices to
use this kind of low temperature sterilizer.
▶ The practical medium sized chamber allows user to sterilize conveniently many medical devices and instruments or bulky loads at once.
▶ User can operate and control the sterilizer conveniently by pressing the operation keys arranged on the control panel and can check
the state of a cycle progressing on the message center (LCD monitor).
▶ Two gas cylinders are available in succession automatically by the control program and the problems like a gas leak or cycle stop
caused by changing the gas cylinder can be prevented.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the monitor
immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in progress
automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
Same as
Gas Mixture N/A N/A
basic cycle
Select one among
Cycle No. Aerate
basic cycle
Expos. Temp.
Pressure
Expos. Time
Aeration time
HS-5025EO
HANSHIN 13
EO Gas Mixture type Sterilizer_Graphic LCD Monitor type
HS- 4 0 8 5EO
Practical Capacity Standard EO Gas Sterilizer
- Practical Sterilization Between Medium
and Small Sized Sterilizer
CYCLE No.1 EO/CO2 CYCLE No.2 EO/CO2 CYCLE No.3 EO/FREON CYCLE No.4 EO/FREON VACUUM LEAK TEST
(High Temp.) (Low Temp.) (High Temp.) (Low Temp.)
14 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and sterilizes the materials
which are unstable under high temperature and moisture or items to which the steam sterilization is inapplicable for the structural
reasons. Therefore it is essential for the medical institutions where using the precise and delicate medical devices to use this kind of
low temperature sterilizer.
▶ This sterilizer is very effective to load a lot of medical devices because it has a practical sized chamber between large and small
sized sterilizer.
▶ This sterilizer adopts the cylindrical chamber with jacket and the variation of chamber temperature is reduced, the sterilizing
temperature can be maintained evenly during progressing a cycle.
▶ Air pollution caused by the leakage of gas after sterilization cycle can be prevented because the sterilization and aeration process
have done in the same chamber successively.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the monitor
immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in progress
automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
Same as
Gas Mixture N/A
basic cycle
Select one among
Cycle No.
basic cycle
Expos. Temp.
Pressure
Sterilization Time
Aeration Time
HS-4085EO
HANSHIN 15
EO Gas Mixture type Sterilizer_Graphic LCD Monitor type
HS- 3 2 4 1EO
Small Capacity Standard EO Gas Sterilizer
- Effective Sterilization For Small
Medical Devices and Instruments
CYCLE No.1 EO/CO2 CYCLE No.2 EO/CO2 CYCLE No.3 EO/FREON CYCLE No.4 EO/FREON VACUUM LEAK TEST
(High Temp.) (Low Temp.) (High Temp.) (Low Temp.)
16 HANSHIN
▶ This sterilizer uses the gas mixture of Ethylene Oxide(EO) and Freon or Carbon Dioxide (CO2) as sterilant, and sterilizes the materials
which are unstable under high temperature and moisture or items to which the steam sterilization is inapplicable for the structural
reasons. Therefore it is essential for the medical institutions where using the precise and delicate medical devices to use this kind of
low temperature sterilizer.
▶ This is an economic and substantial small size EO gas sterilizer for sterilizing the small medical devices, instruments and supplies
effectively.
▶ This sterilizer adopts the cylindrical chamber with jacket and the variation of chamber temperature is reduced, the sterilizing
temperature can be maintained evenly during progressing a cycle.
▶ Air pollution caused by the leakage of gas after sterilization cycle can be prevented because the sterilization and aeration process
have done in the same chamber successively.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the monitor
immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in progress
automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance for analyzing the results of sterilization
and keeping as a quality evidence.
Same as
Gas Mixture N/A
basic cycle
Select one among
Cycle No.
basic cycle
Expos. Temp.
Pressure
Sterilization Time
Aeration Time
HS-3241EO
HANSHIN 17
● Gas is supplied into the chamber from one gas ● Two gas cylinders are connected to the chamber. If one
cylinder on the bottom side of appliance table. cylinder is exhausted, the other is connected
The available gas cylinders are as follows, automatically by the control program. The available gas
① Cylinder of EO / HCFC (30kg) cylinders are as follows,
② Cylinder of EO / CO2 (10kg) ① Cylinder of EO / HCFC (60kg)
② Cylinder of EO / CO2 (25kg)
NOTE :“Preheat Pressure Regulator for EO Gas Only”and“Hose for EO Gas Only”should be used to the EO gas sterilizer,
otherwise very dangerous situation may be occurred.
EO-57A
18 HANSHIN
Ethylene Oxide Gas Mixture
If EO +CO2 gas is injected into the sterilizing chamber directly, a trouble may occur in the piping
system due to the high pressure of the gas (about 45bar at 20℃). Decreasing pressure during delivery
to the chamber may cause an abrupt drop in temperature. Therefore when using EO + CO2 gas as a
sterilant, the exclusive heating-type EO gas pressure regulator (refer to the specification table below)
should be used to depressurize to an adequate level.
※ Caution : Manufacturer and supplier do not responsible for any problem arising from the use of a gas pressure
regulator with a different specification, e.g., for CO2 only.
※ Safety : ① Prevention of temperature increase : The temperature is controlled by the thermostat. In case of
malfunction in the thermostat, the temperature fuse is activated to cut off power.
② Prevention of pressure increase : In case of rising secondary pressure due to the leakage of gas in
the valve seat, the safety valve is activated at the pressure of 9 bar to protect the equipment.
Applicable Gas
Primary Pressure
Secondary pressure
Safety valve
Flow Rate
Heater Capacity
Gas pressure Regulator
Applicable Sterilizer
Thermostat
Power Source
HS-38
EO-57A
HS-57
HANSHIN 19
100% EO Gas type Sterilizer_Touch Screen LCD Monitor type
HS- 4 3 1 3EO
100% EO Gas Cartridge
- Convenient and Safe EO Gas Sterilization
20 HANSHIN
▶ This sterilizer uses 100% ethylene oxide gas as sterilant and sterilizes the medical devices, instruments and supplies effectively by
convenient way of only inserting a small disposable gas cartridge on the holder in the chamber. Cycle progressing is fully automated
by the control system with microprocessor.
▶ The sterilization and aeration process are all completed in the chamber under negative pressure, therefore leakage of EO gas in the
working area can be fully prevented. EO gas being sucked by powerful vacuum pump is exhausted to the prepared drainage with
water safely after sterilization process.
▶ 5 kinds of typical cycle programs and the vacuum leak test cycle are installed in the sterilizer and the operator can select a proper
cycle program according to the type of materials or items to be sterilized and sterilize them conveniently.
▶ The embedded self diagnostic program monitors the cycle progress in real time and displays the error code on the touch screen
monitor immediately accompanying an audible alarm when any trouble has occurred during operation, and then aborts the cycle in
progress automatically for safety of workplace.
▶ The built-in panel printer prints out the cycle performance record for analyzing
the results of sterilization and keeping as a quality evidence.
N/A
Cycle No.
Expos. Temp.
HS-4313EO
HANSHIN 21
EO Gas Monitor
HEGM- 1 0 0 0
Keep All the Time Watch On EO Gas Leakage
For Hospital Safety and Environment !
The monitoring system detects the gas in the air correctly by the gas
sensor, therefore the gas sensor must maintain to the normal state
constantly. The gas sensor should be replaced every two years due to
its life. The zero value and span have to be calibrated after replacing a
new sensor to detect and display the gas concentration correctly.
The replacement of senor and it’ s calibration must be performed by an
authorized technician of the manufacturer.
22 HANSHIN
▶ It is essential to install the gas monitor system in the workplace where operating the EO gas sterilizer for preventing a serious danger
caused by EO gas leakage.
▶ This equipment immediately sounds an audible alarm and takes the emergency measures in case of occurring EO gas leakage for
protecting the health of operators in the workplace.
▶ Rapid and accurate response, stable operating characteristic are technical advantages of this system and it’s convenient to apply
to any special condition because user can change the set values of built-in program.
▶ In case of power failure, the built-in rechargeable battery keeps the monitoring system running continuously about for 3 hours.
Furthermore this system is also available for an efficient surveillance monitor of the other gases by connecting with all kinds of
detectors(sensors) having the output signal of 4~20mA.
▶ The built-in microprocessor for controlling the system detects the monitored data in real time and cuts off the gas supply to the
sterilizer automatically if necessary, and starts the compulsory ventilation fan automatically to eliminate the EO gas in the workplace.
▶
Considering the health hazards caused by EO, the exposure level for operators is restricted strictly within OSHA’s Permissible Exposure
Limit(PEL) of 1 ppm measured as air in an 8 hour time-weighted average(TWA), or Short Term Exposure Limit(STEL) of 5 ppm averaged
over a sampling period of 15 minutes.
▶
EO is flammable when its concentration in the air is over 3%, therefore keep all sources of ignition such as matches, lighted cigarettes,
sparks and static discharge away from the sterilizer. Never put electrical items containing batteries in the loads to be sterilized.
HEGM-1000
HANSHIN 23
Cutting & Sealing Machine for Sterilization Bag
HCS- 4 0 0
Cut & Seal the Roll Pouch for Sterilization
with One Machine Safely and Economically
Using an exclusive machine for cutting and sealing the pouch roll for packing items to
be sterilized is strongly recommended for a safe packing because the items must be
damaged or contaminated if the pouches containing them have damaged while
sterilizing or conserving by reason of wrong packing.
This specially designed machine can cut and seal the pouch roll in one unit, therefore
user is able to do all the work for packing the medical instruments to be sterilized
conveniently and economically in a small space.
24 HANSHIN
▶ The entire process is controlled automatically and displayed digitally on the LED display by a microprocessor.
▶ If the cutting length and quantity are already set in the machine, the roll pouch is attracted to the pouch inlet automatically and the
set quantities of pouch that are sealed bottom side are produced after cutting in the set length.
▶ The pouch contained the item to be sterilized is sealed automatically if the upper side of pouch is inserted in the sealing inlet, and
sealing can be done manually by connecting the foot switch.
▶ The set sealing temperature is maintained constantly by precise control.
▶ The appliance table and the roll stand are provided as an optional items.
HCS-400
HANSHIN 25
Self-Contained BI Incubator
HI- 5 6 1 5
Convenient and Effective Incubation of
Self-Contained Biological Indicator
HI-5615
26 HANSHIN
MEMO