#This is just an example of how the code should look like in the end.

esphome:
name: energy-meter
friendly_name: Energy meter

esp32:
board: esp32dev
framework:
type: arduino

# Enable logging
logger:

# Enable Home Assistant API


api:
encryption:
key: "xxx"

ota:
password: "xxx"

wifi:
ssid: wifi_ssid
password: wifi_password

manual_ip:
# Set this to the IP of the ESP
static_ip: [Link]
# Set this to the IP address of the router. Often ends with .1
gateway: [Link]
# The subnet of the network. [Link] works for most home networks.
subnet: [Link]

# Enable fallback hotspot (captive portal) in case wifi connection fails


ap:
ssid: "Energy-Meter Fallback Hotspot"
password: "password"

captive_portal:

#JSY energy meter protocol


uart:
id: mod_bus
tx_pin: 17
rx_pin: 16
baud_rate: 4800
stop_bits: 1

modbus:
id: modbus1

modbus_controller:
- id: jsymk
#modbus device address
address: 0x1
modbus_id: modbus1
update_interval: 12s
command_throttle: 50ms
i2c:
sda: 21
scl: 22

font:
- file:
type: gfonts
family: Baloo+Bhaijaan+2
weight: 500
id: baloo_18_500
size: 18

- file:
type: gfonts
family: Baloo+Bhaijaan+2
weight: 700
id: baloo_32_700
size: 32

- file:
type: gfonts
family: Baloo+Bhaijaan+2
weight: 700
id: baloo_18_700
size: 18

- file: "gfonts://Material+Symbols+Outlined"
id: icons_18
size: 18
glyphs: ["\ue63e", "\ue648"] # mdi-wifi, mdi-wifi-off

display:
- platform: ssd1306_i2c
model: "SSD1306 128x64"
address: 0x3C
id: oled
rotation: 180°
lambda: |-
[Link](-1, -4, id(baloo_18_500), "Energy Meter");

if(id(connection_status).state == 1) {
[Link](it.get_width(), 0, id(icons_18), TextAlign::TOP_RIGHT, "\ue63e");
}
else {
[Link](it.get_width(), 0, id(icons_18), TextAlign::TOP_RIGHT, "\ue648");
}

[Link](it.get_width()/2, 38, id(baloo_32_700), TextAlign::CENTER, "%.1f


W", id(power1).state);

[Link](0, it.get_height() + 12, id(baloo_18_700), TextAlign::BOTTOM_LEFT,


"%.1f V", id(voltage1).state);

[Link](it.get_width(), it.get_height() + 12, id(baloo_18_700),


TextAlign::BOTTOM_RIGHT, "%.1f A", id(current1).state);

binary_sensor:
# Connection status
- platform: status
name: "Status"
id: connection_status

sensor:
# First channel voltage
- platform: modbus_controller
modbus_controller_id: jsymk
id: voltage1
name: "Voltage"
icon: mdi:alpha-v-box
device_class: energy
address: 0x0048
unit_of_measurement: "V"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# First channel current


- platform: modbus_controller
modbus_controller_id: jsymk
id: current1
name: "Current 1"
icon: mdi:current-ac
device_class: energy
address: 0x0049
unit_of_measurement: "A"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# First channel power


- platform: modbus_controller
modbus_controller_id: jsymk
id: power1
name: "Power 1"
icon: mdi:lightning-bolt
device_class: energy
address: 0x004A
unit_of_measurement: "W"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# First channel energy


- platform: modbus_controller
modbus_controller_id: jsymk
id: energy1
name: "Energy 1"
icon: mdi:lightning-bolt
device_class: energy
address: 0x004B
unit_of_measurement: "kWh"
state_class: total
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# First channel power factor


- platform: modbus_controller
modbus_controller_id: jsymk
id: powerfactor1
name: "Power Factor 1"
icon: mdi:alpha-p-box
device_class: energy
address: 0x004C
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.001
register_count: 1
response_size: 4

# First channel negative active energy


- platform: modbus_controller
modbus_controller_id: jsymk
id: negativeactiveenergy1
#name: "Negative Active Energy 1"
icon: mdi:lightning-bolt
device_class: energy
address: 0x004D
unit_of_measurement: "kWh"
state_class: total
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# First channel current direction


- platform: modbus_controller
modbus_controller_id: jsymk
id: direction1
#name: "Current Direction 1"
icon: mdi:arrow-right
device_class: energy
address: 0x004E
register_type: holding
value_type: U_DWORD
accuracy_decimals: 0
bitmask: 0X01000000
filters:
- multiply: 1
register_count: 1
response_size: 4

# Frequency
- platform: modbus_controller
modbus_controller_id: jsymk
id: frequency
name: "Frequency"
icon: mdi:sine-wave
device_class: energy
address: 0x004F
unit_of_measurement: "Hz"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.01
register_count: 1
response_size: 4

# Second channel voltage


- platform: modbus_controller
modbus_controller_id: jsymk
id: voltage2
#name: "Voltage 2"
icon: mdi:alpha-v-box
device_class: energy
address: 0x0050
unit_of_measurement: "V"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Second channel current


- platform: modbus_controller
modbus_controller_id: jsymk
id: current2
name: "Current 2"
icon: mdi:current-ac
device_class: energy
address: 0x0051
unit_of_measurement: "A"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4
# Second channel power
- platform: modbus_controller
modbus_controller_id: jsymk
id: power2
name: "Power 2"
icon: mdi:lightning-bolt
device_class: energy
address: 0x0052
unit_of_measurement: "W"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Second channel energy


- platform: modbus_controller
modbus_controller_id: jsymk
id: energy2
name: "Energy 2"
icon: mdi:lightning-bolt
device_class: energy
address: 0x0053
unit_of_measurement: "kWh"
state_class: total
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Second channel power factor


- platform: modbus_controller
modbus_controller_id: jsymk
id: powerfactor2
name: "Power Factor 2"
icon: mdi:alpha-p-box
device_class: energy
address: 0x0054
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.001
register_count: 1
response_size: 4

# Second channel negative active energy


- platform: modbus_controller
modbus_controller_id: jsymk
id: negativeactiveenergy2
#name: "Negative Active Energy 2"
icon: mdi:lightning-bolt
device_class: energy
address: 0x0055
unit_of_measurement: "kWh"
state_class: total
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Second channel current direction


- platform: modbus_controller
modbus_controller_id: jsymk
id: direction2
#name: "Current Direction 2"
icon: mdi:arrow-right
device_class: energy
address: 0x004E
register_type: holding
value_type: U_DWORD
accuracy_decimals: 0
bitmask: 0X00010000
filters:
- multiply: 1
register_count: 1
response_size: 4