ﺟﻬﺎﺯ ﺍﻻﻳﺻﺎﻝ ﻻﻗﺭﺏ ﺩﻭﺭ
ﺩﻟﻴﻞ ﺍﻟﻤﺴﺘﺨﺪﻡ
V - 3.2
1
ﺍﻟﻔﻬﺭﺱ
ﺍﻟﻘﺳﻡ -1ﺍﻟﺗﺣﺫﻳﺭﺍﺕ 1 .................................................................................................................................
ﺍﻟﻘﺳﻡ -2ﺍﻟﺧﺻﺎﺋﺹ ﺍﻟﺗﻘﻧﻳﺔ2 ..........................................................................................................................
ﺍﻟﻘﺳﻡ -2.1ﺍﻟﺧﺻﺎﺋﺹ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ3 ..................................................................................................................
ﺍﻟﻘﺳﻡ -3ﻛﻳﻔﻳﺔ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﺷﺎﺷﺔ4 ......................................................................................................................
ﺍﻟﻘﺳﻡ -3 .1ﻗﻳﻡ ﺍﻟﺿﺑﻁ5 ...............................................................................................................................
ﺍﻟﻘﺳﻡ 3.2ﺷﺭﺡ ﺭﻣﻭﺯ ﺍﻷﻭﺍﻣﺭ13 .......................................................................................................................
ﺍﻟﻘﺳﻡ -3 3.ﺍﻟﻣﻔﺿﻝ ﻻﺳﺗﺧﺩﺍﻡ ﺍﻟﺑﻁﺎﺭﻳﺎﺕ14 ...........................................................................................................
ﺍﻟﻘﺳﻡ -4ﺿﺑﻁ ﻗﻳﻡ ﺍﻻﻋﺩﺍﺩﺍﺕ ﺍﻟﺭﺋﻳﺳﻳﺔ15 ................................................................................................................
ﺍﻟﻘﺳﻡ -4.1ﻗﺎﺋﻣﺔ ﺑﺎﻟﻘﻳﻡ ﺍﻟﻅﺎﻫﺭﺓ ﻋﻠﻰ ﺍﻟﺷﺎﺷﺔ17 ......................................................................................................
ﺍﻟﻘﺳﻡ -4.2ﺃﺧﻁﺎء ﺗﻅﻬﺭ ﻋﻠﻰ ﺍﻟﺷﺎﺷﺔ19 ................................................................................................................
ﺍﻟﻘﺳﻡ -5ﻣﺧﻁﻁﺎﺕ ﺍﻟﺗﻭﺻﻳﻝ ﺍﻟﺗﻘﻧﻳﺔ21 ....................................................................................................................
2
ﺍﻟﻘﺴﻢ -1ﺍﻟﺘﺤﺬﻳﺮﺍﺕ
-1ﻻ ﺗﻘﻢ ﺑﺘﻮﺻﻴﻞ ﺍﻭ ﻓﺼﻞ ﺃﻱ ﻣﻦ ﺍﻟﺘﻮﺻﻴﻼﺕ ﻓﻲ ﺣﺎﻝ ﻛﺎﻥ ﺍﻟﺠﻬﺎﺯ ﻳﻌﻤﻞ
-2ﻻ ﺗﻀﻊ ﺍﻟﺠﻬﺎﺯ ﺗﺤﺖ ﺗﺄﺛﻴﺮ ﺣﺮﺍﺭﺓ ﻋﺎﻟﻴﺔ ﺃﻭ ﺑﺮﻭﺩﺓ ﺷﺪﻳﺪﺓ ﺃﻭ ﻣﻜﺎﻥ ﻣﻤﻄﺮ
-3ﻻ ﺗﻀﻌﻪ ﻣﺒﺎﺷﺮ ﺗﺤﺖ ﺗﺄﺛﻴﺮ ﺃﺷﻌﺔ ﺍﻟﺸﻤﺲ
-4ﻻ ﺗﻠﻤﺲ ﺗﻮﺻﻴﻼﺕ ﺍﻟﺘﻐﺬﻳﺔ ﺍﻟﺮﺋﻴﺴﻴﺔ ﺃﻭ ﺗﻮﺻﻴﻼﺕ ﺍﻷﻭﺍﻣﺮ ﻓﻲ ﺣﺎﻝ ﻛﺎﻥ ﺍﻟﺠﻬﺎﺯ ﻳﻌﻤﻞ
-5ﻳﺮﺟﻰ ﻓﺤﺺ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺣﺴﺐ ﺍﻟﻤﺨﻄﻄﺎﺕ ﻟﺘﺠﻨﺐ ﺣﺪﻭﺙ ﺃﺧﻄﺎء
3
ﺍﻟﻘﺴﻢ -2ﺍﻟﺨﺼﺎﺋﺺ ﺍﻟﺘﻘﻨﻴﺔ
• ﻣﺘﻮﺍﻓﻖ ﻣﻊ ﺟﻤﻴﻊ ﺃﻧﻮﺍﻉ ﺍﻟﻠﻮﺣﺎﺕ ﺍﻟﺮﺋﻴﺴﻴﺔ ﻟﻠﻤﺼﺎﻋﺪ.
• ﻳﻤﻜﻨﻚ ﺍﺳﺘﺨﺪﺍﻣﻪ ﻛﺠﻬﺎﺯ ﺍﻳﺼﺎﻝ ﻻﻗﺮﺏ ﻁﺎﺑﻖ ﻟﻠﻤﺼﻌﺪ ﺍﻭ ﺟﻬﺎﺯ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
• ﻳﻌﻤﻞ ﻛﺠﻬﺎﺯﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺗﻤﺎﻣﺎ ﺗﺤﺖ ﺟﻬﺪ 220ﻓﻮﻟﺖ 50ﻫﺮﺗﺰ
• ﻣﺘﻮﺍﻓﻖ ﻣﻊ ﻛﺮﻭﺕ ﺳﻜﺎﻱ ﻭﺟﻤﻴﻊ ﺃﻧﻮﺍﻉ ﺍﻟﻜﺮﻭﺕ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺳﻬﻮﻟﺔ ﺍﻟﺘﻮﺻﻴﻞ
• ﻣﺘﻮﺍﻓﻖ ﻣﻊ ﺟﻤﻴﻊ ﺃﻧﻮﺍﻉ ﺍﻟﻠﻮﺣﺎﺕ ﺍﻟﺮﺋﻴﺴﻴﺔ
• ﻳﻤﻜﻨﻚ ﺍﺳﺘﺨﺪﺍﻣﻪ ﺩﺍﺧﻠﻲ ﺃﻭ ﺧﺎﺭﺟﻲ
• ﻳﻌﻤﻞ ﻣﻊ ﺍﻷﻣﺎﻛﻦ ﺫﺍﺕ ﺗﻐﺬﻳﺔ ﻋﺪﺩ 3ﺑﺠﻬﺪ 220ﻓﻮﻟﻂ ﺑﻴﻦ ﻛﻞ ﻓﺎﺯ ﻭﻋﻠﻰ ﺑﻄﺎﺭﻳﺘﺎﻥ
• ﻋﻨﺪ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻭ ﺣﺪﻭﺙ ﻣﺸﻜﻠﺔ ﻓﻲ ﺃﻱ ﻓﺎﺯ ﺳﻴﺘﻢ ﺍﻳﺼﺎﻝ ﺍﻟﻜﺒﻴﻦ ﻻﻗﺮﺏ ﻁﺎﺑﻖ ﻭﻓﺘﺢ ﺍﻟﺒﺎﺏ
• ﻗﺎﺋﻤﺔ ﺍﻟﻘﻴﻢ ﻳﻤﻜﻨﻚ ﺿﺒﻄﻬﺎ ﺑﺴﻬﻮﻟﺔ ﻣﻦ ﺧﻼﻝ ﺍﻟﺸﺎﺷﺔ ﻭﺍﻷﺯﺭﺍﺭ
• ﻳﻈﻬﺮ ﺣﺎﻟﺔ ﺍﻟﺠﻬﺎﺯ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ ﻭﻳﻈﻬﺮ ﻣﻘﺪﺍﺭ ﻓﻮﻟﻂ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ,ﺍﺳﺘﻬﻼﻙ ﺍﻟﻤﺤﺮﻙ ﻟﻸﻣﺒﻴﺮ ,ﺍﺳﺘﻬﻼﻙ
ﺍﻟﻔﺮﻣﻠﺔ ﻭﺍﻟﺠﺎﻣﺎ ﻭﺟﻤﻴﻊ ﺍﻻﺧﻄﺎء ﻳﻤﻜﻨﻚ ﺭﺅﻳﺘﻬﺎ ﻓﻲ ﺍﻟﺸﺎﺷﺔ
• ﻟﻮﺣﺔ ﻣﻔﺎﺗﻴﺢ ﻗﺎﺑﻠﺔ ﻟﻼﻧﻔﺼﺎﻝ ﻋﻦ ﺍﻟﺠﻬﺎﺯ ﻭﻳﻤﻜﻨﻚ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻻﻛﺜﺮ ﻣﻦ ﺟﻬﺎﺯ ﻋﻨﺪ ﺍﻟﺤﺎﺟﺔ
• ﻳﻌﻤﻞ ﻣﻊ ﺑﻄﺎﺭﻳﺘﺎﻥ ﻟﺤﺪ ﻗﺪﺭﺓ 7.5ﻛﻴﻠﻮ ﻭﺍﻁ ﻭﻳﻐﻄﻲ ﻣﻴﺰﺓ ﺷﺤﻦ ﺑﻄﺎﺭﻳﺘﻴﻦ ﺃﻭ ﺃﺭﺑﻌﺔ ﺣﺴﺐ ﺍﻟﺤﺎﺟﺔ
• ﺍﻟﻔﺮﻣﻠﺔ ﻭﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﺒﺎﺏ ﻣﺤﻤﻴﻴﻦ ﺑﺸﻜﻞ ﻛﺎﻣﻞ ﻓﻲ ﺣﺎﻝ ﺣﺪﻭﺙ ﺗﻤﺎﺱ ﺑﺄﻱ ﻣﻦ ﺧﻄﻮﻁ ﺍﻟﺠﻬﺎﺯ
• ﻓﻲ ﺣﺎﻝ ﻋﺪﻡ ﺗﻮﺻﻴﻞ ﺍﻟﻤﺤﺮﻙ ﻳﻈﻬﺮ ﺧﻄﺄ ﻭﺗﻀﻐﻂ ﺍﻟﻤﻜﺎﺑﺢ ﺍﻭﺗﻮﻣﺎﺗﻴﻜﻴﺎ
• ﻳﺠﺐ ﺭﻓﻊ ﺍﻣﺒﻴﺮ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﻓﻲ ﺣﺎﻝ ﺍﺳﺘﺨﺪﺍﻡ ﻣﺤﺮﻙ 18ﻛﻴﻠﻮ ﻭﺍﻁ ﺍﻭ ﺍﻛﺜﺮ
• ﺗﺴﺘﻄﻴﻊ ﺗﻮﺻﻴﻞ ﺍﻧﻜﻮﺩﺭ ﺍﻟﻤﺤﺮﻙ ﻋﻠﻰ ﺍﻟﺠﻬﺎﺯ ﺍﻥ ﻭﺟﺪ
• ﻳﻌﻴﺪ ﺍﻟﻌﻤﻞ ﻓﻲ ﺣﺎﻝ ﺣﺪﻭﺙ ﺗﻤﺎﺱ ﻛﻬﺮﺑﺎﺋﻲ
• ﺗﺴﺘﻄﻴﻊ ﺗﺤﺪﻳﺪ ﻭﻗﺖ ﻋﻤﻞ ﺍﻟﺠﻬﺎﺯ ﻭﺗﺎﺧﻴﺮﻩ
•ﺗﺴﺘﻄﻴﻊ ﺗﺎﺧﻴﺮ ﺍﻟﻮﻗﻮﻑ ﻋﻠﻰ ﺍﻟﻄﺎﺑﻖ ﺣﺴﺐ ﺍﻟﺤﺎﺟﺔ
• ﻳﺪﻋﻢ ﺍﺑﻮﺍﺏ ﺍﻟﻨﺼﻒ ﺍﻭﺗﻮﻣﺎﺗﻴﻜﻴﺔ ﻭﺍﺑﻮﺍﺏ ﺍﻭﺗﻮﻣﺎﺗﻴﻜﻴﺔ ﻭ ﺍﺑﻮﺍﺏ ﺍﻟﺜﻼﺙ ﻓﺎﺯﺍﺕ
• ﻳﺪﻋﻢ ﺗﺸﻐﻴﻞ ﻣﺤﺮﻙ ﺫﺍﺕ ﻗﺪﺭﺓ 7.5ﻛﻴﻠﻮ ﻭﺍﻁ ﻋﻠﻰ ﺑﻄﺎﺭﻳﺘﺎﻥ ﺩﺍﺧﻠﻴﺘﺎﻥ
• ﻳﺪﻋﻢ ﺍﻻﺑﻨﻴﺔ ﺍﻟﻠﺘﻲ ﺗﺴﺘﻌﻤﻞ ﻛﻬﺮﺑﺎء 220ﺑﺪﻭﻥ ﻧﺘﺮ
• ﻳﻔﺘﺢ ﺍﻟﺒﺎﺏ ﻋﻨﺪ ﺍﻟﻮﺻﻮﻝ ﻭﻳﻘﻔﻠﻪ ﻋﻨﺪ ﺍﻟﺤﺮﻛﺔ ﻭﺑﺎﻣﻜﺎﻧﻚ ﺍﻟﺘﺤﻜﻢ ﺑﻮﻗﺖ ﺍﻟﻘﻔﻞ
• ﺑﺎﻣﻜﺎﻧﻚ ﺍﻟﺘﺤﻜﻢ ﺑﺎﻟﺤﺪ ﺍﻷﻋﻠﻰ ﻟﻮﻗﺖ ﺍﻟﺘﺤﺮﻙ ﺍﺛﻨﺎء ﺍﻟﻄﺎﺑﻖ
• ﺑﺎﻣﻜﺎﻧﻚ ﺭﻓﻊ ﻗﻮﺓ ﺗﺤﻤﻞ ﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﻔﺮﻣﻠﺔ ﻣﻦ ﺍﻟﻘﻴﻢ
• ﺑﺎﻣﻜﺎﻧﻚ ﺭﻓﻊ ﻗﻮﺓ ﺗﺤﻤﻞ ﺍﻟﻤﺤﺮﻙ ﻋﻨﺪ ﺍﻟﺤﺎﺟﺔ
• ﻳﺴﺘﻄﻴﻊ ﻓﺤﺺ ﺍﻻﺗﺠﺎﻩ ﺍﻻﺳﻬﻞ ﻟﻠﺪﻭﺭﺍﻥ ﻛﻲ ﻳﻌﻤﻞ ﻻﻗﺼﻰ ﺩﺭﺟﺔ
• ﺗﺴﺘﻄﻴﻊ ﺗﻮﺻﻴﻞ ﻣﺤﺮﻙ ﺍﻣﺎ 220ﺍﻭ 380ﺑﻴﻦ ﻛﻞ ﻓﺎﺯ *ﺗﻮﺻﻴﻞ ﺩﻟﺘﺎ ﺍﻭ ﺳﺘﺎﺭ*
• ﺗﺴﺘﻄﻴﻊ ﺍﻟﺘﺤﻜﻢ ﺑﻮﻗﺖ ﺗﺸﻐﻴﻞ ﻭﺣﺪﺓ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
• ﺗﺴﺘﻄﻴﻊ ﺗﺸﻐﻴﻞ ﺍﻟﺠﻬﺎﺯ ﻣﻊ ﻣﻐﻨﺎﻁﻴﺲ ﻭﺍﺣﺪ ﺃﻭ ﺍﺛﻨﻴﻦ ﻟﻠﺘﻮﻗﻒ
• ﺗﺴﺘﻄﻴﻊ ﺗﺸﻐﻴﻞ ﺍﻟﺠﻬﺎﺯ ﻣﻊ ﻣﻐﻨﺎﻁﻴﺲ )(Bistable , Monostable
• ﺗﺴﺘﻄﻴﻊ ﺗﺸﻐﻴﻞ ﺍﻟﺠﻬﺎﺯ ﻣﻊ ﺗﻤﺎﺱ )(NO, NC
• ﺗﺴﺘﻄﻴﻊ ﺗﺸﻐﻴﻞ ﺍﻟﺠﻬﺎﺯ ﻣﻊ ﺗﻤﺎﺱ )(60 V DC 110 V DC 220 V DC
4
ﺍﻟﻘﺴﻢ -2ﺍﻟﺨﺼﺎﺋﺺ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ
ﻗﻮﺓ ﺍﻟﻤﺤﺮﻙ ﺍﻋﻠﻰ ﺣﻤﻮﻟﺔ ﺍﻣﺒﻴﺮ ﻭﺿﻊ ﺍﻟﺘﺸﻐﻴﻞ ﻋﺪﺩ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ
7,5 kw ﺍﻳﺻﺎﻝ ﺍﻟﻰ ﺍﻗﺭﺏ ﻁﺎﺑﻖ 16.5 A 24V; 9 Ah
2ﺩﺍﺧﻠﻳﺎﺕ
ﻭﺣﺩﺓ ﻋﺩﻡ ﺍﻧﻘﻁﺎﻉ 4ﺧﺎﺭﺟﻳﺎﺕ 48V; 12 Ah
7,5 kw 16.5 A / 1500W
ﺍﻟﺗﻳﺎﺭ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ
48V; 9 Ah Battery
11 kw ﺍﻳﺻﺎﻝ ﺍﻟﻰ ﺍﻗﺭﺏ ﻁﺎﺑﻖ 24.2 A ﺧﺎﺭﺟﻲ +2ﺩﺍﺧﻠﻲ2
48V; 9 Ah
16 kw ﺍﻳﺻﺎﻝ ﺍﻟﻰ ﺍﻗﺭﺏ ﻁﺎﺑﻖ 35.2 A ﺧﺎﺭﺟﻳﺎﺕ 4
5
ﺍﻟﻘﺴﻢ -3ﻛﻴﻔﻴﺔ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﺸﺎﺷﺔ
.1ﻳﺮﺟﻰ ﺿﻐﻂ ﺯﺭ ENTERﻓﻲ ﺍﻟﺸﺎﺷﺔ ﻟﻠﺪﺧﻮﻝ ﺍﻟﻰ ﻗﺎﺋﻤﺔ ﺍﻟﻀﺒﻂ
.2ﻳﺮﺟﻰ ﺍﻟﺘﺤﺮﻳﻚ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺯﺭﻱ UPﺃﻭ DOWNﻻﺧﺘﻴﺎﺭ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺮﺍﺩ ﺗﻐﻴﻴﺮﻫﺎ
.3ﻳﺮﺟﻰ ﺿﻐﻂ ﺯﺭ ENTERﺑﻌﺪ ﺍﺧﺘﻴﺎﺭ ﺍﻟﻘﻴﻤﺔ
.4ﻳﺮﺟﻰ ﺗﻐﻴﻴﺮ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻰ ﺍﻟﻤﺮﺍﺩ ﻭﺿﻌﻪ ﻭﺿﻐﻂ ﺯﺭ ENTER
) ﻓﻲ ﺣﺎﻝ ﻅﻬﺮﺕ ﺭﺳﺎﻟﺔ PARAMETER FAILEDﻳﺠﺐ ﺿﺒﻂ ﺍﻟﻘﻴﻤﺔ ﻣﺮﺓ ﺍﺧﺮﻯ(
.5ﺗﺴﺘﻄﻴﻊ ﺗﻐﻴﻴﺮ ﻗﻴﻤﺔ ﺍﺧﺮﻯ ﻧﻔﺲ ﺍﻟﻄﺮﻳﻘﺔ ﺑﺎﺳﺘﺨﺪﻡ ﺍﻷﺳﻬﻢ ﻭﺯﺭ ﺍﻟﻤﻮﺍﻓﻘﺔ
.6ﻳﺮﺟﻰ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺯﺭ ESCAPEﺑﻌﺪ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺍﻟﺘﻌﺪﻳﻞ ﺍﻟﻼﺯﻡ ﻟﻠﻌﻮﺩﺓ ﺍﻟﻰ ﺍﻟﻘﺎﺋﻤﺔ ﺍﻟﺮﺋﻴﺴﻴﺔ
6
ﺍﻟﻘﺴﻢ - 3.1ﻗﻴﻢ ﺍﻟﻀﺒﻂ
1 WORKING TYPE
1 NORMAL RESCUE
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .1ﻭﺿﻊ ﺍﻟﺘﺸﻐﻴﻞ
=1 WORKING TYPEﺟﻬﺎﺯ ﺍﻳﺼﺎﻝ ﻻﻗﺮﺏ ﻁﺎﺑﻖ
=2 NORMAL RESCUEﻭﺣﺪﺓ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ 220ﻓﻮﻟﺖ
2 BATTERY QTY
1 2 BATTERY
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .2ﻋﺪﺩ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ
=1 2BATTERYﺑﻄﺎﺭﻳﺘﺎﻥ
4 =2 4BATTERYﺑﻄﺎﺭﻳﺎﺕ
3 MAGNET TYPE
1 [Link]
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .3ﻧﻮﻉ ﺍﻟﻤﻐﻨﺎﻁﻴﺴﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﺘﻮﻗﻒ
=1 BISTABLE MAGNETﻣﻐﻨﺎﻁﻴﺲ ﺑﻲ ﺳﺘﺎﺑﻞ
=2 MONOSTABLE MAGNETﻣﻐﻨﺎﻁﻴﺲ ﻣﻮﻧﻮ ﺳﺘﺎﺑﻞ
7
4 MAGNET QTY
1 1 MAGNET
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .4ﻋﺪﺩ ﺍﻟﻤﻐﻨﺎﻁﻴﺴﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﺘﻮﻗﻒ
=1 1 MAGNETﻣﻐﻨﺎﻁﻴﺲ ﻭﺍﺣﺪ
=2 2 MAGNETﻣﻐﻨﺎﻁﻴﺴﻴﻦ
5 MAGNET CONTACT
1 NORMALLY OPEN
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .4ﻧﻮﻉ ﺍﻟﺘﻤﺎﺱ ﻟﻠﻤﻐﻨﺎﻁﻴﺴﺎﺕ
=1ﺗﻤﺎﺱ ﻣﻔﺘﻮﺡ )NORMALLY OPEN; (NO
=2ﺗﻤﺎﺱ ﻣﻐﻠﻖ )NORMALLY CLOSED; (NC
6 KS CONTROL
2 D KS PASS.
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .6ﻓﺤﺺ ﺑﺪﺍﻳﺔ ﻭﻧﻬﺎﻳﺔ ﺍﻟﺸﻮﻁ
=1ﺗﻔﻌﻴﻞ ﺍﻟﻔﺤﺺ ACTIVE CONTROL
=2ﺗﻌﻄﻴﻞ ﺍﻟﻔﺤﺺ PASSIVE CONTROL
8
7 CAM BRAKE VOLT
1 CAM / BRE. 60 VOLT
ﺗﻐﺬﻳﺔ ﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﻔﺮﻣﻠﺔ.7 ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ
ﻓﻮﻟﺖ60 =1 BRAKE PUMP VOLT 60
ﻓﻮﻟﺖ110 =2 BRAKE PUMP VOLT110
ﻓﻮﻟﺖ220 =3 BRAKE PUMP VOLT220
8 POWER SUPP. FLOOD
1 380 VOLT SUPP.
ﻧﻮﻉ ﺍﻟﺘﻐﺬﻳﺔ.8 ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ
ﻓﻮﻟﺖ380 =1 380 VOLT
( ﻓﻮﻟﺖ )ﺑﺪﻭﻥ ﻧﺘﺮ220 =2 220 VOLT
9 DOOR TYPE
2 FULL AUTOMATIC
ﻧﻮﻉ ﺍﻟﺒﺎﺏ.9 ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ
= ﻳﺪﻭﻱ1 NOT AUTOMATIC
= ﺍﻭﺗﻮﻣﺎﺗﻴﻜﻲ2 FULL AUTOMATIC
= ﺛﻼﺙ ﻓﺎﺯﺍﺕ3 TREEPHASE DOORS
9
10 MOTOR VOLT
2 MOTOR 380 VOLT
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .10ﻧﻮﻉ ﺗﻮﺻﻴﻞ ﺍﻟﻤﺤﺮﻙ
220 =1ﻓﻮﻟﺖ MOTOR 220 VOLT
380 =2ﻓﻮﻟﺖ )ﺍﻟﺨﻴﺎﺭ ﺍﻻﻓﺘﺮﺍﺿﻲ( MOTOR 380 VOLT
11 ENGINE POWER
2 ENGINE 7.5 KW
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .11ﻗﺪﺭﺓ ﺍﻟﻤﺤﺮﻙ
5.5 =1ﻛﻴﻠﻮ ﻭﺍﻁ MOTOR 5.5 KW
7.5 =2ﻛﻴﻠﻮ ﻭﺍﻁ MOTOR 7.5 KW
11 =3ﻛﻴﻠﻮ ﻭﺍﻁ MOTOR 11 KW
16 =4ﻛﻴﻠﻮ ﻭﺍﻁ MOTOR 16 KW
12 DOOR OPEN TM.
008
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .12ﺯﻣﻦ ﻓﺘﺢ ﺍﻟﺒﺎﺏ
ﻳﺘﻢ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺜﺎﻧﻴﺔ
10
13 DOOR CLOSE TM.
010
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .13ﺯﻣﻦ ﺍﻏﻼﻕ ﺍﻟﺒﺎﺏ
ﻳﺘﻢ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺜﺎﻧﻴﺔ
14 DO TEST TM.
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .14ﺯﻣﻦ ﺗﺠﺮﻳﺐ ﺍﻟﺒﺎﺏ
ﻳﺘﻢ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺜﺎﻧﻴﺔ
15 LOCK WAIT. TM
008
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .15ﺯﻣﻦ ﻗﻔﻞ ﺍﻟﺒﺎﺏ
ﻳﺘﻢ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺜﺎﻧﻴﺔ
11
16 GEN WAITING
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .16ﺗﺄﺧﻴﺮ ﺯﻣﻦ ﺍﻟﺘﺸﻐﻴﻞ
ﻳﺘﻢ ﺗﻐﻴﻴﺮﻩ ﺑﺎﻟﺜﺎﻧﻴﺔ
TRYING QTY 17
003
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .17ﻋﺪﺩ ﺍﻟﻤﺤﺎﻭﻻﺕ ﻓﻲ ﺣﺎﻝ ﻋﺪﻡ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻰ ﺍﻟﻄﺎﺑﻖ
18 UPS [Link]
002
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .18ﻋﺪﺩ ﺩﻗﺎﺋﻖ ﺗﺸﻐﻴﻞ ﻭﺿﻊ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
12
19 AFTER [Link].
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .19ﻭﻗﺖ ﺑﻘﺎء ﺍﻟﺠﻬﺎﺯ ﻣﻨﻴﺮﺍ ﺑﻌﺪ ﺍﻟﻌﻤﻞ
20 FLIR T ARRIVAL
059
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .20ﻣﺪﺓ ﺍﻟﺘﺤﺮﻙ ﺑﻴﻦ ﺍﻟﻄﺎﺑﻖ
21 ENGINE EX TORQ
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .21ﺭﻓﻊ ﻗﺪﺭﺓ ﺍﻟﻤﺤﺮﻙ )ﻓﻲ ﺣﺎﻝ ﺻﻌﻮﺑﺔ ﺍﻟﺪﻭﺭﺍﻥ(
13
INV 22. EX. TORQ
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .22ﺭﻓﻊ ﻗﺪﺭﺓ ﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﻔﺮﻣﻠﺔ )ﻓﻲ ﺣﺎﻝ ﺻﻌﻮﺑﺔ ﺍﻟﺴﺤﺐ(
23 M. TEST LEVEL
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .23ﺭﻓﻊ ﻗﺪﺭﺓ ﺗﺠﺮﻳﺐ ﺍﻻﺗﺠﺎﻩ ﺍﻻﺳﻬﻞ ﻟﻠﺪﻭﺭﺍﻥ )ﻓﻲ ﺣﺎﻝ ﺻﻌﻮﺑﺔ ﺍﻟﺪﻭﺭﺍﻥ(
24 DEFAULT SETTI.
000
ﺍﻟﻘﻴﻤﺔ ﺭﻗﻢ .24ﺍﺳﺘﻌﺎﺩﺓ ﺍﻻﻋﺪﺍﺩﺍﺕ ﺍﻻﻓﺘﺮﺍﺿﻴﺔ
14
ﺍﻟﻘﺴﻢ - 3.2ﺷﺮﺡ ﺭﻣﻮﺯ ﺍﻷﻭﺍﻣﺮ
U.V.W ﻛﺑﻼﺕ ﺗﻭﺻﻳﻝ ﺍﻟﻣﺣﺭﻙ ﺗﻭﺻﻝ ﻋﻠﻰ ﻣﻠﻑ ﺍﻟﺳﺭﻳﻊ
110.P ﻳﻭﺻﻝ ﺑﺩﺍﻳﺔ ﺍﻣﺎﻥ ﺍﻟﻠﻭﺣﺔ ﺍﻟﻰ ﻫﻧﺎ
110.K ﻳﺧﺭﺝ ﻣﻥ ﻫﻧﺎ ﺍﻟﻰ ﺍﻟﺑﺋﺭ
140.P ﻳﻭﺻﻝ ﻧﻬﺎﻳﺔ ﺍﻣﺎﻥ ﺍﻟﻠﻭﺣﺔ ﺍﻟﻰ ﻫﻧﺎ
140.K ﻳﻭﺻﻝ ﻗﻔﻝ ﺍﻟﺑﺎﺏ ﻫﻧﺎ
810 - ﺍﻟﺟﺎﻣﺎ )(-
2001 + ﺍﻟﺟﺎﻣﺎ )(+
840 + ﺍﻟﻔﺭﻣﻠﺔ )(+
2000 - ﺍﻟﻔﺭﻣﻠﺔ )(-
K.N ﻧﺗﺭ ﺍﻟﺑﺎﺏ ﻭﻧﺗﺭ ﻭﺣﺩﺓ ﻋﺩﻡ ﺍﻧﻘﻁﺎﻉ ﺍﻟﺗﻳﺎﺭ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ
100 ﻳﻭﺻﻝ ﺍﻟﻰ ﺍﻟﻠﻭﺣﺔ ﻣﺑﺎﺷﺭ ﺍﻟﻰ ﻧﻔﺱ ﺍﻟﺭﻗﻡ
KFP ﻳﻭﺻﻝ ﻣﺩﺧﻝ ﻓﺎﺯ ﻣﺳﺗﻣﺭ ﺍﻟﻣﺧﺻﺹ ﻟﻠﺑﺎﺏ ﺍﻟﻘﺎﺩﻡ ﻣﻥ ﺍﻟﻠﻭﺣﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ
KFK ﻳﺧﺭﺝ ﺗﻐﺫﻳﺔ ﻓﺎﺯ ﺍﻟﻰ ﺍﻟﺑﺎﺏ ﺗﻭﺻﻝ ﻣﺑﺎﺷﺭﺓ
K3 ﺍﺷﺎﺭﺓ ﺍﻏﻼﻕ ﺍﻟﺑﺎﺏ
K5 ﺍﺷﺎﺭﺓ ﻓﺗﺢ ﺍﻟﺑﺎﺏ
K15K ﻣﺷﺗﺭﻙ ﺍﺷﺎﺭﺓ ﺍﻟﺑﺎﺏ ﺍﻟﺫﺍﻫﺏ ﺍﻟﻰ ﺍﻟﺑﺎﺏ
K15P ﻣﺷﺗﺭﻙ ﺍﺷﺎﺭﺓ ﺍﻟﺑﺎﺏ ﺍﻟﻘﺎﺩﻡ ﻣﻥ ﺍﻟﻠﻭﺣﺔ
KR1 ﻣﺧﺭﺝ ﺗﻐﺫﻳﺔ ﻓﻲ ﺣﺎﻝ ﺍﺣﺗﺟﺕ ﺍﻟﻰ 220ﻓﻭﻟﺕ ﻓﻲ ﺣﺎﻝ ﺍﻧﻘﻁﺎﻉ ﺍﻟﺗﻳﺎﺭ ﻓﻘﻁ
R ﻓﺎﺯ ﺭﺋﻳﺳﻲ ﻳﻭﺻﻝ ﺑﻌﺩ ﻗﺎﻁﻊ ﺍﻟﻠﻭﺣﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ
S ﻓﺎﺯ ﺭﺋﻳﺳﻲ ﻳﻭﺻﻝ ﺑﻌﺩ ﻗﺎﻁﻊ ﺍﻟﻠﻭﺣﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ
T ﻓﺎﺯ ﺭﺋﻳﺳﻲ ﻳﻭﺻﻝ ﺑﻌﺩ ﻗﺎﻁﻊ ﺍﻟﻠﻭﺣﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ
N ﻧﺗﺭ
MKU/141 ﻋﺩﺍﺩ ﺍﻟﻁﻭﺍﺑﻖ
MKD/142 ﺣﺳﺎﺱ ﺍﻟﺗﻭﻗﻑ
817 ﺑﺩﺍﻳﺔ ﺍﻟﺷﻭﻁ
818 ﻧﻬﺎﻳﺔ ﺍﻟﺷﻭﻁ
869 ﻳﻭﺻﻝ ﻣﻔﺗﺎﺡ ﻋﻠﺑﺔ ﺍﻟﺻﻳﺎﻧﺔ
U.V.W ﻣﺧﺭﺝ ﺑﺎﺏ ﺛﻼﺙ ﻓﺎﺯﺍﺕ )ﻳﺣﺗﺎﺝ ﺍﻟﻰ ﻁﺭﻧﺱ(
15
-3 2ﺍﻟﻤﻔﻀﻞ ﻻﺳﺘﺨﺪﺍﻡ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ.ﺍﻟﻘﺴﻢ
ﺍﺳﺘﺨﺪﻡ ﺑﻄﺎﺭﻳﺘﺎﻥ 12ﻓﻮﻟﺖ 9ﺃﻣﺒﻴﺮ ﺩﺍﺧﻞ ﺍﻟﺠﻬﺎﺯ ﻓﻲ ﻭﺿﻊ 380ﻓﻮﻟﺖ ﺗﻐﺬﻳﺔ ﻭ ﻭﺿﻊ
ﺍﻳﺼﺎﻝ ﺍﻟﻰ ﺍﻗﺮﺏ ﻁﺎﺑﻖ ﻣﻦ ﺍﺟﻞ ﻣﺤﺮﻙ 7.5ﻛﻴﻠﻮ ﻭﺍﻁ ﻭﻣﺎ ﺩﻭﻥ
ﺍﺳﺘﺨﺪﻡ ﺑﻄﺎﺭﻳﺘﺎﻥ 12ﻓﻮﻟﺖ ﺩﺍﺧﻞ ﺍﻟﺠﻬﺎﺯ ﻓﻲ ﻭﺿﻊ 220ﻓﻮﻟﺖ ﺗﻐﺬﻳﺔ ﺑﺪﻭﻥ ﻧﺘﺮ ﻭ ﻭﺿﻊ
ﺍﻳﺼﺎﻝ ﺍﻟﻰ ﺍﻗﺮﺏ ﻁﺎﺑﻖ ﻣﻦ ﺍﺟﻞ ﻣﺤﺮﻙ :
7.5ﻛﻴﻠﻮ ﻭﺍﻁ ﻭﻣﺎ ﺩﻭﻥ ﺑﻄﺎﺭﻳﺘﺎﻥ 12ﻓﻮﻟﻂ 7ﺃﻣﺒﻴﺮ
9.0ﻛﻴﻠﻮ ﻭﺍﻁ ﺑﻄﺎﺭﻳﺘﺎﻥ 12ﻓﻮﻟﻂ 9ﺃﻣﺒﻴﺮ
11.0ﻛﻴﻠﻮ ﻭﺍﻁ ﺍﺭﺑﻊ ﺑﻄﺎﺭﻳﺎﺕ 12ﻓﻮﻟﻂ 11ﺃﻣﺒﻴﺮ
16.0ﻛﻴﻠﻮ ﻭﺍﻁ ﺍﺭﺑﻊ ﺑﻄﺎﺭﻳﺎﺕ 12ﻓﻮﻟﻂ 18ﺃﻣﺒﻴﺮ
ﺍﺳﺘﺨﺪﻡ 4ﺑﻄﺎﺭﻳﺎﺕ ﻓﻲ ﺣﺎﻝ ﺍﺭﺩﺕ ﺗﺸﻐﻴﻞ ﺍﻟﺠﻬﺎﺯ ﻓﻲ ﻭﺿﻊ ﻭﺣﺪﺓ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ
ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
16
ﺍﻟﻘﺴﻢ -4ﺿﺒﻂ ﻗﻴﻢ ﺍﻻﻋﺪﺍﺩﺍﺕ ﺍﻟﺮﺋﻴﺴﻴﺔ
ﺍﻟﻘﻴﻤﺔ ﺣﺪﻭﺩ ﺍﻟﻀﺒﻂ ﺿﺒﻂ ﺍﻟﻤﺼﻨﻊ ﺍﻟﺸﺮﺡ
ﻭﺿﻊ ﻋﻤﻞ ﺍﻟﺠﻬﺎﺯ
1 WORKING TYPE
1 --2 1 -1ﺟﻬﺎﺯ ﺍﻳﺼﺎﻝ ﻻﻗﺮﺏ ﺩﻭﺭ
ﻧﻮﻉ ﺍﻟﻌﻤﻞ
-2ﻭﺣﺪﺓ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
2 BATTERY QTY -1ﺑﻄﺎﺭﻳﺘﺎﻥ
1 -- 2 1
ﻋﺪﺩ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ -2ﺃﺭﺑﻊ ﺑﻄﺎﺭﻳﺎﺕ
-1ﺑﻲ ﺳﺘﺎﺑﻞ
3 MAGNET TYPE
1 -- 2 1
ﻧﻮﻉ ﺍﻟﺤﺴﺎﺱ ﺍﻟﻤﻐﻨﺎﻁﻴﺴﻲ -2ﻣﻮﻧﻮ ﺳﺘﺎﺑﻞ
-1ﺣﺴﺎﺱ ﻭﺍﺣﺪ
4 MAGNET QTY
1 -- 2 1
ﻋﺪﺩ ﺍﻟﺤﺴﺎﺳﺎﺕ ﺍﻟﻤﻐﻨﺎﻁﻴﺴﻴﺔ -2ﺣﺴﺎﺳﺎﻥ )ﻣﻦ ﺍﺟﻞ ﻧﻈﺎﻡ ﺍﻟﺘﺴﻮﻳﺔ(
-1ﺗﻤﺎﺱ ﻣﻔﺘﻮﺡ
5 MAGNET CONTACT
1 -- 2 1
ﻧﻮﻉ ﺗﻤﺎﺱ ﺍﻟﺤﺴﺎﺳﺎﺕ
-2ﺗﻤﺎﺱ ﻣﻐﻠﻖ
-1ﺗﻌﻘﺐ ﺑﺪﺍﻳﺔ ﻭﻧﻬﺎﻳﺔ ﺍﻟﺸﻮﻁ
6 KSR CONTROL
1 -- 2 2
ﺑﺪﺍﻳﺔ ﻭﻧﻬﺎﻳﺔ ﺍﻟﺸﻮﻁ
-2ﻋﺪﻡ ﺗﻌﻘﺐ ﺑﺪﺍﻳﺔ ﻭﻧﻬﺎﻳﺔ ﺍﻟﺸﻮﻁ
ﻓﻮﻟﻂ ﺍﻟﻔﺮﻣﻠﺔ ﻭﺍﻟﺠﺎﻣﺎ
7 CAM BRAKE VOLT
60 -1ﻓﻮﻟﻂ
1--3 1
110-2ﻓﻮﻟﻂ
ﻓﻮﻟﻂ ﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﻔﺮﻣﻠﺔ
220-3ﻓﻮﻟﻂ
ﺍﻟﻜﻬﺮﺑﺎء ﺍﻟﺮﺋﻴﺴﻴﺔ
8 POWER SUPPLY
1 -- 2 1 380 -1ﻓﻮﻟﻂ ﻣﻊ ﻧﺘﺮ
ﻧﻮﻉ ﺍﻟﺘﻐﺬﻳﺔ
220-2ﻓﻮﻟﻂ ﺑﺪﻭﻥ ﻧﺘﺮ
ﻧﻮﻉ ﺍﻟﺒﺎﺏ
-1ﻧﺼﻒ ﺍﺗﻮﻣﺎﺗﻴﻜﻲ
9 DOOR TYPE
1 -- 3 1 -2ﺃﻭﺗﻮﻣﺎﺗﻴﻜﻲ
ﻧﻮﻉ ﺍﻟﺒﺎﺏ ﺍﻟﻤﺴﺘﺨﺪﻡ
-3ﺛﻼﺙ ﻓﺎﺯﺍﺕ ﻭﻟﻜﻦ ﻳﺤﺘﺎﺝ ﺍﻟﻰ ﻣﺤﻮﻝ
ﺍﺿﺎﻓﻲ ﻓﻲ ﻫﺬﻩ ﺍﻟﺤﺎﻟﺔ
17
ﺍﻟﻘﻴﻤﺔ ﺣﺪﻭﺩ ﺍﻟﻀﺒﻂ ﺿﺒﻂ ﺍﻟﻤﺼﻨﻊ ﺍﻟﺸﺮﺡ
220 -1ﻓﻮﻟﻂ
10 ENGINE VOLTAGE
1 -- 2 1
ﻓﻮﻟﻄﺎﺝ ﺍﻟﻤﺤﺮﻙ 380 -2ﻓﻮﻟﻂ
ﻗﺪﺭﺓ ﺍﻟﻤﺤﺮﻙ
5.5 -1ﻛﻴﻠﻮ ﻭﺍﻁ
)11 ENGINE POWER (KW
1 -- 4 1 7.5 -2ﻛﻴﻠﻮ ﻭﺍﻁ
ﻗﺪﺭﺓ ﺍﻟﻤﺤﺮﻙ
11 -3ﻛﻴﻠﻮ ﻭﺍﻁ
16 -4ﻛﻴﻠﻮ ﻭﺍﻁ
12 DOOR OPEN TIME
0--20 8 ﻳﻌﻴﺮ ﺑﺎﻟﺜﺎﻧﻴﺔ
ﺯﻣﻦ ﺍﻟﻤﺴﺘﻐﺮﻕ ﻟﻔﺘﺢ ﺍﻟﺒﺎﺏ
13 DOOR CLOSE TM
0--20 8 ﻳﻌﻴﺮ ﺑﺎﻟﺜﺎﻧﻴﺔ
ﺯﻣﻦ ﺍﻟﻤﺴﺘﻐﺮﻕ ﻻﻏﻼﻕ ﺍﻟﺒﺎﺏ
14 DOOR TEST TM
0-20 0
ﻭﻗﺖ ﺗﺠﺮﻳﺐ ﺍﻟﺒﺎﺏ ﻋﻨﺪ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﻳﻌﻴﺮ ﺑﺎﻟﺜﺎﻧﻴﺔ
15 LOCK WAIT TIME
0-20 8 ﻳﻌﻴﺮ ﺑﺎﻟﺜﺎﻧﻴﺔ
ﻭﻗﺖ ﻗﻔﻞ ﺍﻟﺒﺎﺏ
16 GEN. WAITING
0-30 0 ﺗﺎﺧﻴﺮ ﺯﻣﻦ ﺍﻟﻌﻤﻞ ﻋﻨﺪ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ
ﺗﺎﺧﻴﺮ ﺯﻣﻦ ﺑﺪء ﺍﻟﺘﺸﻐﻴﻞ
17 TRIYING QTY
0-- 5 3 ﻋﺪﺩ ﻣﺮﺍﺕ ﺍﻟﺘﺠﺮﺑﺔ
ﻋﺪﺩ ﺍﻟﻤﺤﺎﻭﻻﺕ ﻓﻲ ﺣﺎﻝ ﻋﺪﻡ ﺍﻟﻮﺻﻮﻝ
18 UPS [Link]
0-10 1 ﻳﻌﻴﺮ ﺑﺎﻟﺪﻗﻴﻘﺔ
ﻣﺪﺓ ﻋﻤﻞ ﻭﺣﺪﺓ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ
19 AFTER WORK JF
0-20 0 ﻋﻨﺪ ﺍﻟﻮﺻﻮﻝ ﺍﻟﻰ ﺍﻟﻄﺎﺑﻖ
ﺗﺎﺧﻴﺮ ﻭﻗﻮﻑ ﺍﻟﻤﺼﻌﺪ
20 FLR ARRIVAL T
0-59 59
ﺍﻟﻮﻗﺖ ﺍﻟﻤﺘﻮﻗﻊ ﻟﻠﻮﺻﻮﻝ ﺍﻟﻰ ﺍﻟﻄﺎﺑﻖ ﻳﻌﻴﺮ ﺑﺎﻟﺜﺎﻧﻴﺔ
21 MOTOR [Link] ﻓﻲ ﺣﺎﻝ ﻟﻢ ﻳﺴﺘﻄﻊ ﺍﻟﺘﺪﻭﻳﺮ
0-20 0
ﺭﻓﻊ ﻗﺪﺭﺓ ﺍﻟﻤﺤﺮﻙ ﻳﺮﺟﻰ ﺭﻓﻊ ﺍﻟﻘﻴﻤﺔ
22 INV. EX. TORQ ﻓﻲ ﺣﺎﻝ ﻭﺟﺪﺕ ﻣﺸﻜﻠﺔ ﻓﻲ ﺳﺤﺐ ﺍﻟﺠﺎﻣﺎ
0-20 0
ﺭﻓﻊ ﻗﺪﺭﺓ ﺍﻟﻔﺮﻣﻠﺔ ﻭﺍﻟﺠﺎﻣﺎ ﻭﺍﻟﻔﺮﻣﻠﺔ ﻳﺮﺟﻰ ﺭﻓﻊ ﺍﻟﻘﻴﻤﺔ
23 M. TEST LEVEL ﻳﺮﺟﻰ ﺭﻓﻊ ﺍﻟﻘﻴﻤﺔ ﻓﻲ ﺣﺎﻝ ﻟﻢ ﻳﺴﺘﻄﻊ
0-10 3
ﺗﺠﺮﻳﺐ ﺍﻻﺗﺠﺎﻩ ﺍﻻﺳﻬﻞ ﺍﻟﺠﻬﺎﺯ ﺗﺤﺪﻳﺪ ﺍﻟﻤﺴﺎﺭ ﺍﻻﺳﻬﻞ
24 DEFAULT SETT
0-1 0 ﺍﺿﻐﻂ ﺭﻗﻢ 1ﻟﻀﺒﻂ ﺍﻟﻤﺼﻨﻊ
ﺍﻋﺪﺍﺩﺍﺕ ﺍﻟﻤﺼﻨﻊ ﺍﻻﻓﺘﺮﺍﺿﻴﺔ
ﺍﻟﻘﺴﻢ - 4.1ﻗﺎﺋﻤﺔ ﺑﺎﻟﻘﻴﻢ ﺍﻟﻈﺎﻫﺮﺓ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ
18
BATT. I. M. CHAR
[Link] XX XX XX.X
ﻓﻮﻟﻄﺎﺝ ﺍﻟﺒﻄﺎﺭﻳﺔ = BATT.
ﻣﺴﺤﻮﺏ ﺍﻷﻣﺒﻴﺮ ﻟﻠﻔﺮﻣﻠﺔ ﻭﺍﻟﺠﺎﻣﺎ = I
ﻣﺴﺤﻮﺏ ﺍﻷﻣﺒﻴﺮ ﻟﻠﻤﺤﺮﻙ = M
ﻓﻮﻟﺘﺎﺝ ﺷﺤﻦ ﺍﻟﺒﻄﺎﺭﻳﺔ = CHR
GEN. WAITING
[Link] XX XX XX.X
ﻭﺿﻊ ﺍﻻﺳﺘﻌﺪﺍﺩ
RESCUE ACTIVE
[Link] XX XX XX.X
ﻭﺿﻊ ﺍﻟﻮﺻﻮﻝ ﻻﻗﺮﺏ ﻁﺎﺑﻖ ﻳﻌﻤﻞ
19
DOOR TEST WAIT.
[Link] XX XX XX.X
ﺑﺎﻧﺘﻈﺎﺭ ﺗﺠﺮﻳﺐ ﺍﻟﺒﺎﺏ ﻋﻨﺪ ﺍﻟﺤﺎﺟﺔ
DOOR CLOSING
[Link] XX XX XX.X
ﻳﺘﻢ ﺍﻏﻼﻕ ﺍﻟﺒﺎﺏ
LOCK WAITING
[Link] XX XX XX.X
ﺑﺎﻧﺘﻈﺎﺭ ﻗﻔﻞ ﺍﻟﺒﺎﺏ ﺍﻟﻨﺼﻒ ﺍﻭﺗﻮﻣﺎﺗﻴﻜﻲ
20
UPS ACTIVE
[Link] XX XX.X
ﻭﺿﻊ ﻭﺣﺪﺓ ﻋﺪﻡ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﻳﻌﻤﻞ
DOOR OPENING
[Link] XX XX.X
ﻳﺘﻢ ﻓﺘﺢ ﺍﻟﺒﺎﺏ
CAR AT FLOOR
[Link] XX XX.X
ﺍﻟﻜﺒﻴﻦ ﻣﺘﻮﻗﻒ ﻋﻠﻰ ﺍﻟﻄﺎﺑﻖ
ﺍﻟﺤﺴﺎﺱ ﻣﺸﻴﺮ ﺍﻟﻰ ﺍﻥ ﺍﻟﻜﺒﻴﻦ ﻣﺘﻮﻗﻒ ﻋﻠﻰ ﺍﻟﻄﺎﺑﻖ
21
ﺍﻟﻘﺴﻢ - 4.2ﺃﺧﻄﺎء ﺗﻈﻬﺮ ﻋﻠﻰ ﺍﻟﺸﺎﺷﺔ
KFK SHORT CIRCUIT
[Link] XX XX XX.X
ﻳﻮﺟﺪ ﺗﻤﺎﺱ ﻓﻲ ﺧﻂ KFK
ﻳﺮﺟﻰ ﻓﺤﺺ ﺗﻮﺻﻴﻞ ﻫﺬﺍ ﺍﻟﺨﻂ KFK
CAM SHRT CIRCUIT
[Link] XX XX XX.X
ﻳﻮﺟﺪ ﺗﻤﺎﺱ ﻓﻲ ﺧﻂ ﺍﻟﺠﺎﻣﺎ
ﻳﺮﺟﻰ ﻓﺤﺺ ﺗﻮﺻﻴﻞ ﺍﻟﺠﺎﻣﺎ
BRK SHRT CIRCUIT
[Link] XX XX XX.X
ﻳﻮﺟﺪ ﺗﻤﺎﺱ ﻓﻲ ﺧﻂ ﺍﻟﻔﺮﻣﻠﺔ
ﻳﺮﺟﻰ ﻓﺤﺺ ﺗﻮﺻﻴﻞ ﺍﻟﻔﺮﻣﻠﺔ
22
MOTOR CABLE CHCK
[Link] XX XX XX.X
ﻓﻴﺸﺔ ﺍﻟﻤﺤﺮﻙ ﻏﻴﺮ ﻣﻮﺻﻮﻟﺔ
ﻳﺮﺟﻰ ﺍﻟﺘﺎﻛﺪ ﻣﻦ ﺗﻮﺻﻴﻞ ﻛﺒﻼﺕ ﺍﻟﻤﺤﺮﻙ
MTR Shrt CIRCUIT
[Link] XX XX.X
ﻳﻮﺟﺪ ﺗﻤﺎﺱ ﻓﻲ ﺧﻂ ﺍﻟﻤﺤﺮﻙ
ﻳﺮﺟﻰ ﺍﻟﺘﺎﻛﺪ ﻣﻦ ﻋﺪﻡ ﻭﺟﻮﺩ ﺍﻱ ﺗﻤﺎﺱ ﺑﻴﻦ ﻛﺎﺑﻼﺕ ﺍﻟﻤﺤﺮﻙ
BATTERY LOW
[Link] XX XX.X
ﻳﻮﺟﺪ ﺿﻌﻒ ﻓﻲ ﻣﺴﺘﻮﻯ ﺍﻟﺒﻄﺎﺭﻳﺔ
ﻳﺮﺟﻰ ﺍﻟﻤﻼﺣﻈﺔ ﺍﻥ ﻫﺬﻩ ﺍﻟﺮﺳﺎﻟﺔ ﻣﻤﻜﻦ ﺍﻥ ﺗﻈﻬﺮ ﻓﻲ ﺣﺎﻝ ﻟﻢ ﻳﺘﻢ ﺍﺧﺘﻴﺎﺭ ﻋﺪﺩ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﻣﻦ ﺍﻟﺒﺮﻣﺠﺔ
ﻭﺗﻈﻬﺮ ﻓﻲ ﺣﺎﻝ ﻋﻄﻞ ﺑﻄﺎﺭﻳﺔ ﻭﺍﺣﺪﺓ ﺍﻭ ﺍﻛﺜﺮ ﻳﺠﺐ ﻓﺤﺺ ﻭﺍﺣﺪﺓ ﻭﺍﺣﺪﺓ ﻭﺗﻈﻬﺮ ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ
ﻛﺎﻧﺖ ﻓﺎﺭﻏﺔ
23
24