3ϕ, 2.
5 KVA, 0-415V
3ϕ Autotransformer
Isc (5/10A, 250V/500V)
R A m L
~ c v
3ϕ, 230V, 50hz
AC SUPPLY
V Vsc
Y ~ N=0
(0 - 250V) Rotor is blocked
or
low range multimeter STATOR ROTOR
B
c v
ICDP / TPMCB
m L
(5/10A, 250V/500V)
BLOCKED ROTOR TEST ON 3ϕ INDUCTION MOTOR