300 PSI CWP Iron Body Gate Valves: 300 PSI/20 .6 Bar Non-Shock Cold Working Pressure

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views1 page

300 PSI CWP Iron Body Gate Valves: 300 PSI/20 .6 Bar Non-Shock Cold Working Pressure

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

[Link].

com
AHEAD OF THE F L O W® Revised 11/15/2021

300 PSI CWP Iron Body Gate Valves


Fire Protection Valve • Outside Screw and Yoke • Resilient Wedge •
Epoxy Coated Interior/Exterior • Pre-Grooved Stem for Supervisory Switch •
Boss Position A Not Tapped
300 PSI/20.6 Bar Non-Shock Cold Working Pressure
UL/ULC LISTED† • FM APPROVED • CERTIFIED LEAD-FREE BY
TRUESDAIL LABORATORIES TO NSF/ANSI 61 & 372
MATERIAL LIST
PART SPECIFICATION
1. Valve Body Ductile Iron ASTM A536
2. Resilient Wedge Ductile Iron ASTM A536/EPDM ASTM D2000
3. Wedge Nut ASTM B584 UNS C83600
4. Dowel Pin ASTM A276 SS304
5.
6.
Stem Back Seat O-Ring
Bonnet Gasket
EPDM ASTM D2000
EPDM ASTM D2000
F-607-RWSB
Flanged
7. Bonnet Ductile Iron ASTM A536
8. Stem Packing EPDM ASTM D2000
9. Threaded Rod ASTM A276 SS304
10. Gland Bushing ASTM B584 UNS C83600
11. Gland Ductile Iron ASTM A536
12. Gland Nut ASTM B148 C95200 Aluminum Bronze
13. Yoke Ductile Iron ASTM A536
14. Yoke Bushing ASTM B150 C61400
15. Flat Point Set Screw ASTM F912M
16. Yoke Bushing Retainer Cast Iron ASTM A126 Class B
17. Handwheel Ductile Iron ASTM A536
18. Handwheel Nut Carbon Steel Zinc Plated
19. Stem Stainless Steel 304
20. Bonnet Screw Corrosion-resistant Steel
21. Drive Screw Label (not shown) Stainless Steel 304
22. UL/FM Label (not shown) Aluminum
23. Yoke Screw Steel Plated ASTM A307
Coating — Electrostatically applied fusion-bonded epoxy 8-20 mil. inside and outside meets or exceeds AWWA C550.
† Compliance with the Standard for Gate Valves for Fire Protection Service, UL 262, and the Canadian Requirements, ULC/ORD-C262.
NOTE: Flanged valve is consistent with ANSI B16.1 Class 125.

F-607-RWSB
Flg x Flg
DIMENSIONS—WEIGHTS—QUANTITIES
Dimensions
Size A B Open B Closed C D E F G Bolt Circle Flange Turns to Weight
In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Holes. Open. Lbs. Kg.
2¹⁄₂ 65 7.5 190 17.8 453 14.9 378 0.69 17.5 7.0 178 7.9 200 1.50 38 1.42 36 5.50 140 4 6.3 39 18
3 80 8.0 203 19.7 500 15.9 405 0.75 19.0 7.5 191 7.9 200 1.73 44 1.42 36 6.00 152 4 10.0 44 20
4 100 9.0 229 21.0 534 16.6 422 0.94 24.0 9.0 229 10.2 260 2.13 54 1.42 36 7.50 191 8 10.0 72 33
6 150 10.5 267 29.3 744 22.9 581 1.00 25.4 11.0 279 12.4 315 2.24 57 1.54 39 9.50 241 8 15.0 117 53
8 200 11.5 292 37.0 939 28.5 724 1.13 28.6 13.5 343 14.8 375 2.48 63 1.54 39 11.75 298 8 16.7 198 90
10 250 13.0 330 44.8 1139 34.5 877 1.19 30.2 16.0 406 16.4 416 3.15 80 1.82 46 14.25 362 12 20.8 374 170
12 300 14.0 356 52.2 1326 39.9 1014 1.25 31.8 19.0 483 17.5 445 2.91 74 1.82 46 17.00 432 12 25.0 493 224
14* 350 15.0 375 62.2 1580 50.0 1270 1.38 35.0 21.0 533 19.7 500 2.95 75 3.20 81 18.75 476 12 43.8 620 284
16* 400 16.0 400 65.9 1674 50.4 1280 1.44 37.0 23.5 597 19.7 500 3.03 77 3.20 81 21.25 540 16 50.0 816 370
*14 and 16" valves 250 PSI CWP
WARNING: This product can expose you to c hemicals including lead, which is known to theState of California to cause cancer and birthdefects or other
reproductive harm. For more information go to [Link].
FREEZING WEATHER PRECAUTION: Subsequent to testing a piping system, gate valve should be in an open position to allow complete drainage.
LEAD-FREE: Weighted average lead content <0.25% Visit our website for the most current information.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 21
[Link]