1
TECHNICAL REPORT
Comprehensive Semantic Model
for Energy Management
Blue Book Edition 15 Part 1 Amendment 1
OBIS CODES
DLMS UA 1000-1 Ed. 15 Part 1 Am. 1
27 th June 2023
Version 1.0
DLMS User Association
© Copyright 1997-2023 DLMS User Association
2
4 CONTENTS
5 CONTENTS ................................................................................................................... 1
6 1 Scope GK 23-0224: This shall be Clause 1 ................................................................. 3
7 1.1 Updates relating to firmware information in various Tables ................................... 3
8 1.2 Updates relating to support for the EVCS Profile (Phase 1) .................................. 3
9 2 Revision history ....................................................................................................... 3
10 3 Technical corrections ............................................................................................... 3
11 3.1 Table 36 – OBIS codes for general and service entry objects – HCA ..................... 3
12 3.2 Table 44 – OBIS codes for general and service entry objects – Thermal
13 energy ............................................................................................................ 4
14 3.3 Table 60 – OBIS codes for general and service entry objects – Gas ...................... 4
15 3.4 Table 67 – OBIS codes for general and service entry objects – Water ................... 5
16 3.5 Table 14 – Value group D codes – A.C. Electricity............................................... 6
17 3.6 Table 26 – Value group D codes – D.C. Electricity .............................................. 7
18 3.7 Table 8 – OBIS codes for general and service entry objects ................................. 7
19
20
21
22
DLMS User Association 2023-06-27 DLMS UA 1000-1 Part 1 Ed 15 Am. 1 1/8
© Copyright 1997-2023 DLMS User Association
23 FOREWORD
24 Copyright
25 © Copyright 1997-2023 DLMS User Association
26 This document is confidential. It may not be copied, nor handed over to persons outside the
27 DLMS User Association.
28 The copyright is enforced by national and international law. The "Berne Convention for the
29 Protection of Literary and Artistic Works", which is signed by 176 countries world-wide, and
30 other treaties apply.
31 Acknowledgement
32 The document has been written by members of DLMS UA Maintenance Working Group .
33
2/8 2023-06-27 DLMS UA 1000-1 Part 1 Ed. 15 Am. 1 DLMS User Association
© Copyright 1997-2023 DLMS User Association
34 1 Scope
35 Amendment 1 amends the following Clauses of DLMS UA 1000-1 Ed. 15 Part 1 (Blue Book Part
36 1 Edition 15):
37 1.1 Updates relating to firmware information in various Tables
38 Tables 8, 36, 44, 60, 67 have been updated to include information relevant to support the
39 harmonization of firmware objects. These tables already specify codes of objects that hold
40 firmware information. The amendments here harmonize the objects across the various media
41 (Abstract, AC electricity, DC electricity etc.).
42 Excerpts of the relevant parts of the Tables have been inserted in this Amendment.
43 1.2 Updates relating to support for the EVCS Profile (Phase 1)
44 Tables 8, 14 and 26 have been updated to include information relevant to support the EVCS
45 Profile (Phase 1)
46 Excerpts of the relevant parts of the Tables have been inserted in this Amendment.
47
48 2 Revision history
Version Date Author Comment
0.1 Gould Initial draft
0.2 GK 23-0-24: Update
0.3 Gould Update for review
0.4 Gould Updates following review
0.8 Gould For approval by Maintenance WG
0.8.2. 27/03/2023 Gould
29/03/2023 Commented by G.Kmethy
0.9 4/4/23 Gould Included GK comments
1.0 27/6/23 Gould Published
49 3 Technical corrections
50 Modifications to the Tables are shown as appropriate excerpts in the following clauses.
51
52 3.1 Table 36 – OBIS codes for general and service entry objects – HCA
53
General and service entry objects - HCA OBIS code
A B C D E F
Configuration
DLMS User Association 2023-06-27 DLMS UA 1000-1 Part 1 Ed 15 Am. 1 3/8
© Copyright 1997-2023 DLMS User Association
Program version no. Active firmware identifier 4 b 0 2 0 *255
Firmware version no. Active firmware version 4 b 0 2 1 *255
Software version no. 4 b 0 2 2 *255
Active firmware signature 4 b 0 2 8 *255
54
55 3.2 Table 44 – OBIS codes for general and service entry objects – Thermal energy
56
General and service entry objects – thermal energy OBIS code
A B C D E F
57
Configuration
Program version Active firmware identifier 5/6 b 0 2 0 *255
Firmware version Active firmware version 5/6 b 0 2 1 *255
Software version 5/6 b 0 2 2 *255
a
Meter location (flow or return) 5/6 b 0 2 3
Device version 5/6 b 0 2 4
Active firmware signature 5/6 b 0 2 8 *255
Serial number of inlet (flow) temperature transducer 5/6 b 0 2 10
Serial number of outlet (return) temperature transducer 5/6 b 0 2 11
Serial number of forward flow transducer 5/6 b 0 2 12
Serial number of return flow transducer 5/6 b 0 2 13
Conversion factors
58
59 3.3 Table 60 – OBIS codes for general and service entry objects – Gas
60
OBIS code
General and shows service entry objects – Gas
A B C D E F
Free ID-numbers for utilities
61
Configuration
Program version Active firmware identifier 7 b 0 2 0 *255
Firmware version Active firmware version 7 b 0 2 1 *255
Software version 7 b 0 2 2 *255
Device version 7 b 0 2 3
Active firmware signature 7 b 0 2 8
4/8 2023-06-27 DLMS UA 1000-1 Part 1 Ed. 15 Am. 1 DLMS User Association
© Copyright 1997-2023 DLMS User Association
Number of device channels 7 b 0 2 10
Pressure sensor, serial no. 7 b 0 2 11
Temperature sensor, serial no. 7 b 0 2 12
Calculator, serial no. 7 b 0 2 13
Volume sensor a , serial no. 7 b 0 2 14
Density sensor, serial no. 7 b 0 2 15
Sensor (medium irrespective), serial no. 7 b 0 2 16
Digital output configuration 7 b 0 2 17
Analogue output configuration 7 b 0 2 18
62
63
64 3.4 Table 67 – OBIS codes for general and service entry objects – Water
65
OBIS code
General and service entry objects – Water
A B C D E F
66
Program entries
Program version no. Active firmware identifier 8/9 b 0 2 0 *255
Device version no. 8/9 b 0 2 3 *255
Active firmware signature 8/9 b 0 2 8 *255
67
68
DLMS User Association 2023-06-27 DLMS UA 1000-1 Part 1 Ed 15 Am. 1 5/8
© Copyright 1997-2023 DLMS User Association
69
70 3.5 Table 14 – Value group D codes – A.C. Electricity
71
Value group D codes – Electricity (A = 1, C 0, 93, 94, 96, 97, 98, 99)
72
55 Test average
56 Current average 4 for harmonics measurement
58 Time integral 4
60 Possible value
128...254 Manufacturer specific codes
All other Reserved
Rows omitted
Time integral 7 Time integral of the quantity calculated from the origin (first start of measurement) up to
the end of the last recording period with recording period 1, see Error! Reference source
not found..
Time integral 8 Time integral of the quantity calculated from the origin (first start of measurement) up to
the end of the last recording period with recording period 2, see Error! Reference source
not found..
Time integral 9 Time integral of the quantity calculated from the beginning of the current billing period up
to the end of the last recording period with recording period 1, see Error! Reference
source not found..
Time integral 10 Time integral of the quantity calculated from the beginning of the current billing period up
to the end of the last recording period with recording period 2, see Error! Reference
source not found..
Under limit values Values under a certain threshold (for example dips).
Over limit values Values above a certain threshold (for example swells).
Missing values Values considered as missing (for example interruptions).
Possible value Value for contract or related limit value for the associated measured value. Example – a value of
power or current that is a contractual restriction on the consumption through a supply point intended
to permit EVCS to calculate limit of power available for charging.
73
74
75
76
77
78
6/8 2023-06-27 DLMS UA 1000-1 Part 1 Ed. 15 Am. 1 DLMS User Association
© Copyright 1997-2023 DLMS User Association
79 3.6 Table 26 – Value group D codes – D.C. Electricity
Value group D codes – Electricity (A = 2, C 0, 93, 94, 96, 97, 98, 99)
80
55 Test average
56 Current average 4 for harmonics measurement
58 Time integral 4
60 Possible value
128...254 Manufacturer specific codes
All other Reserved
Rows omitted
Time integral 7 Time integral of the quantity calculated from the origin (first start of measurement) up to
the end of the last recording period with recording period 1, see Error! Reference source
not found..
Time integral 8 Time integral of the quantity calculated from the origin (first start of measurement) up to
the end of the last recording period with recording period 2, see Error! Reference source
not found..
Time integral 9 Time integral of the quantity calculated from the beginning of the current billing period up
to the end of the last recording period with recording period 1, see Error! Reference
source not found..
Time integral 10 Time integral of the quantity calculated from the beginning of the current billing period up
to the end of the last recording period with recording period 2, see Error! Reference
source not found..
Under limit values Values under a certain threshold (for example dips).
Over limit values Values above a certain threshold (for example swells).
Missing values Values considered as missing (for example interruptions).
Possible value Value for contract or related limit value for the associated measured value. Example – a value of
power or current that is a contractual restriction on the consumption through a supply point intended
to permit EVCS to calculate limit of power available for charging.
81
82 3.7 Table 8 – OBIS codes for general and service entry objects
83
General and service entry objects OBIS code
A B C D E F
Rows omitted
Input/output control signals
State of input/output control signals, global c 0 b 96 3 0
State of input control signals (status word 1) 0 b 96 3 1
State of output control signals (status word 2) 0 b 96 3 2
State of input/output control signals (status word 3) 0 b 96 3 3
State of input/output control signals (status word 4) 0 b 96 3 4
Disconnect control 0 b 96 3 10
DLMS User Association 2023-06-27 DLMS UA 1000-1 Part 1 Ed 15 Am. 1 7/8
© Copyright 1997-2023 DLMS User Association
General and service entry objects OBIS code
A B C D E F
g
Rates of change values
Reconnect loading rate: 0 0 96 3 12
Load reduction shedding rate: 0 0 96 3 13
Arbitrator 0 b 96 3 20..
29
Rows omitted
a
84 Date of the event may contain the date only, the time only or both, encoded as specified in Error! Reference
85 source not found., 4.5.1.
b
86 Protected configuration is characterized by the need to open the main meter cover to modify it, or to break a
87 metrological seal.
c
88 Global status words with E = 0 contain the individual status words E = 1…4. The contents of the status words are
89 not defined in this document.
d
90 Time of power failure is recorded when either a short or long power failure occurs.
e
91 Duration of long power failure holds the duration of the last long power failure.
f
92 The range D = 50…99 is available for identifying objects, which are not represented by another defined code,
93 but need representation on the display as well. If this is not required, the range D = 128…254 should be used.
g
94 This is a time related value used mainly for rate of change especially when signalling a load device to change
95 its loading takes place.
96
97 End.
8/8 2023-06-27 DLMS UA 1000-1 Part 1 Ed. 15 Am. 1 DLMS User Association