STRUCTURAL DATA
A- Design data
Capacity V = 50.00 KL
Staging S = 15.00 m
Net SBC of soil = 15.00 T/m²
N value = 30
Depth of Foundation df = 2.00 m
SHALL BE CHECK AS PER
Dead storage = 150.00 mm
VENDOR DATA
Free board fb = 500.00 mm
Ground Level (G.L) = + 192.235 m
Low Water Level (L.W.L) = + 207.385 m
Effective water height = 3.550 m
(EXCLUDING D.S,F.B)
Max Water Level (M.W.L) = + 210.935 m
Total Height of tank = 4.200 m
Live load on top dome Ld = 1500.00 N/m²
Live load on staircase = 1500.00 N/m²
Live load on gallery Lbs = 5000.00 N/m²
Grade of concrete (for Top roof) = M- 30
Grade of concrete (for tank portion-remaining components) = M- 30
Grade of concrete (for staging) = M- 25
Nominal maximum size of Coarse aggregate = 20.00 mm
Grade of steel = Fe 500
B - Assumed Dimensions
1.0 Water Tank
Internal dia of tank = 4.33 m
Roof Slab
•Thickness = 200.00 mm
Roof beams - RB1
•Width b = 300.00 mm
•Depth d = 400.00 mm
Roof ring beam(RB)
•Width bi2 = 350.00 mm
•Depth di2 = 500.00 mm
Zinc Alum tank wall
•Height = 4.200 m
•Thickness at top t₃ = 1.20 mm
•Thickness at bottom t₃ = 1.20 mm
2.0 Tank Supporting Tower
C/c distance of columns Dc = 3.062 m
No of columns nc = 4.00 no.s
Size of columns
DIA D = 450.00 mm
Size of Brace beams
•Width bb = 200.00 mm
•Depth db = 400.00 mm
Brace levels =4
CG OF EMPTY CONTAINER 0.09 M
Size of Isloated footing
Size of footing 1.80 X 1.80 m
Thickness of footing at the edge of column = 450.00 mm
Thickness at the edge of footing df = 450.00 mm
Gallery Projection
•Projection from face of the beam = 1000.00 mm
•Thickness = 125.00 mm
THICKNESS OF PCC(M15) = 150.00 mm
C- Design References
IS:456 : Code of practice for plain and reinforced concrete
IS:3370 : Code of practice for concrete structures for the storage of liquids
IS:875 : Code of practice for structural safety of buildings, loading standards
IS:1911 : Dead loads
IS:1893 : Criteria for earthquake resistant design and structures
IS:11682 : Criteria for design of RCC staging for overhead water tanks
& Related Tender documents
D- Design Constants
Unit wt of concrete ϒc = 25 kN/m³
Density of water w = 10.00 kN/m³
Characterstic strength (As per IS 456 :2000) fy = 500.00 N/mm²
Stress in steel for water reataining structures-(As per Table 4 of IS 3370 (part2) )
Tensile stress under direct tension, bending & σst or σsv = 130.0 N/mm²
shear
Compressive stress in columns subjected to direct σsc 140 N/mm²
load
Permissible stress in compression ( Table 21 of IS 456& Table 1 of IS 3370 (part2):2009)
• Bending = 30.00 σcbc = 10.00 N/mm²
• Direct = 30.00 σcc = 8.00 N/mm²
Permissible stresses in Concrete for Water Retaining Structures ( Table 1 of IS 3370 )
Direct Tension stress ft = 1.50 N/mm²
Tension due to Bending stress fbt = 2.00 N/mm²
Values of Concrete Constants (Limit State)
• for M-30
Ru = 0.133 x 30 = = 3.99
• for M-30
Ru = 0.133 x 30 = = 3.990
Minimum reinforcement in water retaining portion (Clause 8.1.1 of IS 3370-part-2:2009 )
Maximum dimension of tank = = 4.33 m
% reinforcement = = 0.280 %
E-Volume calculation of Water tank
Outer dia of tank = 4.33 m
Wall thickness at top = 0.001 m
Wall thickness at bottom = 0.001 m
Inner dia of tank at top = 4.33 m
Inner dia of tank at bottom = 4.33 m
Avg.Inner dia of tank = 4.33 m
Depth of water in Tank excluding F.B & D.S (H) = 3.55 m
Volume of circular portion = π/4x4.33^2x3.55
3
= 52.27 m
3
> 50.00 m