0% found this document useful (0 votes)
33 views7 pages

fischer Bolt Anchor FAZ II Plus Design Guide

The document provides detailed design specifications for the fischer Bolt Anchor FAZ II Plus, including input data, design actions, and resulting anchor forces. It outlines the installation details, resistance to tension and shear loads, and emphasizes the importance of adhering to local standards and approvals. Technical remarks highlight that the calculations are based on specific assumptions and that any changes to the system require new calculations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views7 pages

fischer Bolt Anchor FAZ II Plus Design Guide

The document provides detailed design specifications for the fischer Bolt Anchor FAZ II Plus, including input data, design actions, and resulting anchor forces. It outlines the installation details, resistance to tension and shear loads, and emphasizes the importance of adhering to local standards and approvals. Technical remarks highlight that the calculations are based on specific assumptions and that any changes to the system require new calculations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

C-FIX 1.123.0.

0
Database version
2024.4.26.15.27
Date
29/09/2024

fischer systems Asia Pte. Ltd.

4, Kaki Bukit Avenue 1


#01-06, Singapore 417939
Phone: +65 6741 0480
Fax: +65 6741 0481
[email protected]
www.fischer.sg

Design Specifications
Anchor
Anchor system fischer Bolt Anchor FAZ II Plus
Anchor Bolt Anchor FAZ II Plus 16/5,
zinc plated steel
Calculated anchorage 80 mm
depth
Design Data Anchor design in Concrete according European Technical
Assessment ETA-19/0520, Option 1,
Issued 24/05/2023

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

Input data

Design method TR055/ETAG 001, Annex C, Method A


Base material C25/30, EN 206
Concrete condition Cracked, dry hole
Reinforcement No or standard reinforcement. No edge reinforcement. With
reinforcement against splitting
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap acc. user input
Type of loading Permanent-Transient/Static
Base plate location Base plate flush installed on base material
Base plate geometry 300 mm x 150 mm x 8 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 10.36 8.00 2.36 0.41 0.41 0.00 Permanent-Transient/Static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 5.72 3.19 2.67 -1.76
2 5.01 2.78 2.67 0.79
3 4.29 4.27 2.67 3.33

max. concrete compressive strain : 0.08 ‰


max. concrete compressive stress : 2.5 N/mm²
Resulting tensile actions : 15.02 kN , X/Y position ( -10 / 0 )
Resulting compression actions : 4.66 kN , X/Y position ( 54 / 68 )

Resistance to tension loads

Action Capacity Utilisation βN


Proof kN kN %
Steel failure * 5.72 56.21 10.2
Pullout failure * 5.72 20.16 28.4
Concrete cone failure 15.02 33.17 45.3

* Most unfavourable anchor

Steel failure

( NRd,s )

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
78.70 1.40 56.21 5.72 10.2

βN,s
Anchor no. % Group N° Decisive Beta
1 10.2 1 βN,s;1
2 8.9 2 βN,s;2
3 7.6 3 βN,s;3

Pullout failure

( NRd,p )

NRk,p Ψc γMp NRd,p NSd βN,p


kN kN kN %
30.24 1.120 1.50 20.16 5.72 28.4

The given Psi,c-factor may has been determined by interpolation.

βN,p
Anchor no. % Group N° Decisive Beta
1 28.4 1 βN,p;1
2 24.8 2 βN,p;2
3 21.3 3 βN,p;3

Concrete cone failure

( NRd,c )

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
49.75 1.50 33.17 15.02 45.3

βN,c
Anchor no. % Group N° Decisive Beta
1, 2, 3 45.3 1 βN,c;1

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 4.27 54.72 7.8
Concrete pry-out failure 2.78 27.59 10.1

* Most unfavourable anchor

Steel failure without lever arm

( VRd,s )

VRk,s γMs VRd,s VSd βVs


kN kN kN %
68.40 1.25 54.72 4.27 7.8

βVs
Anchor no. % Group N° Decisive Beta
1 5.8 1 βVs;1
2 5.1 2 βVs;2
3 7.8 3 βVs;3

Concrete pry-out failure

( VRd,cp )

Eq. (5.6)

Eq. (5.2)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

VRk,cp γMc VRd,cp VSd βV,cp


kN kN kN %
41.39 1.50 27.59 2.78 10.1

βV,cp
Anchor no. % Group N° Decisive Beta
2 10.1 1 βV,cp;1

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 10.2 Steel failure without lever arm * 7.8
Pullout failure * 28.4 Concrete pry-out failure 10.1
Concrete cone failure 45.3
* Most unfavourable anchor

Resistance to combined tensile and shear loads


Eq. (5.8a)
Proof successful Eq. (5.8b)

Eq. (5.9)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 8 mm

Profile type Customized profile

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required. The calculation was done under the assumption that a sufficient
splitting reinforcement is available. In this case the spliiting
failure can be omitted.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.123.0.0
Database version
2024.4.26.15.27
Date
29/09/2024

Installation data
Anchor
Anchor system fischer Bolt Anchor FAZ II Plus
Anchor Bolt Anchor FAZ II Plus 16/5, Art.-No. 564594
zinc plated steel

Accessories Blow-out pump ABG big Art.-No. 567792


SDS Plus-V II 16/160/210 Art.-No. 531827

Installation details
Thread diameter M 16
Drill hole diameter d0 = 16 mm
Drill hole depth h2 = 113 mm
Calculated anchorage hef = 80 mm
depth
Installation depth hnom = 98 mm
Drilling method Hammer drilling
Borehole cleaning Clear the borehole with a hand
blower.
The installation instructions should
be followed when installing without
borehole cleaning.
Installation type Push-through installation
Annular gap acc. user input
Installation torque Tinst = 110.0 Nm
Socket size 24 mm
Base plate thickness t = 8 mm
Total fixing thickness tfix = 8 mm
Tfix,max tfix, max = 10 mm

Base plate details


Base plate material Not available
Base plate thickness t = 8 mm
Clearance hole in base df=18 mm
plate

Attachment
Profile type Customized profile

Profile dimensions mm
Height 8
Width 300

Anchor coordinates

x y
Anchor no. mm mm
1 -110 0
2 0 0
3 110 0

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in