6000 Counts
Intelligent Digital Multimeter
Brief Introduction
The meter is a portable intelligent one that can automatically identify
the ACV, DCV, resistance, buzzer and capacitance and choose the range
accordingly. The users with no professional physical knowledge can
measure the technical data of electrical appliance easily.
The meter has illumination, backlight function and magnetic
adherence design can provide lots of help to air conditioner
maintenance engineers.
The large LED screen has analog display which can show the variation
tends of the measurements. 6000 display makes the readings more
accurate.
It complies with the IEC 61010 600V CATII and pollution grade 2
standards.
Panel Symbols:
1: Illumination
2. NCV sensing area
3. LED display
4. Buzzer
5. Capacitance/Diode/Frequency
shift button
6. Backlight/illumination button
7. Power on/off
8. input socket
9. COM input socket
10. 10A input socket
11. Data Hold/NCV button
12. NCV indicator
Safety Information
Safety Instructions
*When using this meter, the user must comply with all the standard
safety regulations in the following two aspects
A: Protection against electric shocks
B: Preventing the misuse of the instrument's safety procedures
*To ensure your personal safety, please use the test pen provided with
the meter, check before use, and make sure they are intact.
Safety Symbols
Safety Notices:
The use of meter instruments near devices with large
electromagnetic disturbances will be unstable and may even cause
large errors.
Do not use when the appearance of the meter or the test pen is
broken.
If the meter is not used correctly, the safety functions provided by
the meter may fail.
Care must be taken when working around bare conductors or buses.
Do not use this instrument near explosive gas vapor or dust.
The correct input function must be used to measure the range.
The input value must not exceed the limit of the input value specified
for each range to prevent damage to the instrument.
Do not touch the unused input when the instrument is connected to
the circuit under test.
When the measured voltage exceeds 60 VDC or 30 VAC, use caution
to prevent electric shock.
When measuring with a test pen, place your finger behind the guard
ring of the test.
Before converting the range, it must be ensured that the test pens
have left the circuit under test.
Before carrying out a resistance, diode, capacitance measurement or
continuity test, the circuit under test must be powered off and all
high-voltage capacitors in the circuit under test should be discharged.
Do not measure the resistance on a live circuit or perform buzzer
test.
Before conducting the current measurement, the fuse of the meter
should be checked. Before connecting the meter to the circuit under
test, the power of the circuit under test should be turned off.
When performing TV repairs or measuring power conversion circuits,
care must be taken in the high-amplitude voltage pulses in the circuit
under test to avoid damage to the meter.
The instrument uses three pieces AAA 1.5V batteries as the power
supply. The battery must be properly installed in the battery
compartment of the meter.
When the battery with low voltage symbol appears, replace the
battery immediately. Insufficient battery power can make the meter
read incorrectly, which may result in electric shock or personal injury.
When measuring voltages, do not exceed 600V. Do not use the
instrument when the instrument's housing or part of the housing is
removed.
Maintenance:
When opening the instrument case or removing the battery
cover, pull out the test pen first.
The specified replacement parts must be used to service the
meter.
Before opening the meter, all relevant power must be
disconnected. At the same time, you must ensure that you do not
have static electricity to avoid damage to the meter.
Instrument components, instrument calibration and maintenance
operation instructions are operated by professionals.
When opening the instrument housing, some capacitance in the
instrument must be noticed. Even after the instrument is turned
off, dangerous voltages are kept.
If the instrument is observed any abnormality, the table should
be immediately stopped and sent for repair, and to ensure that it
can not be used before inspection qualified.
When not in use for a long time, please remove the battery, and
avoid storing in high temperature and humidity.
Input protection measures
The limit voltage is 600V when the voltage is measuring.
The limit voltage is 250 ACV or the equivalent RMS voltage when
the capacitance or the diode is measuring.
Battery Replacement and Accessories
Please follow the steps below to replace the battery:
1. Turn off the power of the instrument and pull all the test pens out
of the input socket
2. Use a screwdriver to loosen the screws fixing the battery.
3. Remove the battery cover and take away the old battery
4. Replace the new batteries 3*AAA
5. Install batteries cover and close the screws.
Accessories
1. An instruction
2. A pair of test leads
3. Three pieces of AAA batteries
4. Temperature test leads
Specifications
Function Range Resolution Accuracy Note
DCV 1V-600V 0.001V-0.1V ±(0.8%+5) Min Input Voltage:1V
Max Input Voltage:600V
Resistor Impedance:10M
ACV 1V-600V(45-2kHZ) 0.001V-0.1V ±(1.0%+5) Min Input Voltage:1V
Max Input Voltage:600V
Resistor Impedance:10M
Resistor 1Ω-60MΩ 0.1Ω-0.01KΩ ±(1.0%+5) Protection:600V AC/DC
Temperature -50~1300C(-58~2372F) 1C/1F ±(3.0%+5) Protection:250V AC/DC
CAP 0.001nF~100mF 0.001nF~0.1mF ±(4.0%+5) Protection:250V AC/DC
HZ 10Hz-1000Hz 0.1Hz-1Hz ±(2.0%+5) VPP more than 1V RMS
Max display 6000
Auto Power-off √ No operation for 5 mints
Backlit √ Turn off after 30 seconds
Illumination √ Turn off after 30 seconds
Diode √ Voltage forward drop 3.0V
Buzzer Protection:600V AC/DC
Buzzer √
Indicator
NCV √ “----“ refers strong-middle-weak
NCV Indicator √
L Wire Detect √ “----“refers strong-middle-weak
True RMS √ 45Hz-2kHz
Low Battery √
Symbols on the Screen
Technical Datasheet
Comprehensive indicators
*Operating conditions:
600V CAT II Pollution grade: 2
Height: under 2000m
Working temperature: 0-40℃(<80%RH)
Storage temperature: -10-60℃(<70%RH, take off battery)
*Test or calibrate surrounding temperature: 20℃±2℃
*The biggest voltage between measurement end and ground: 600V
*Conversion rate: about 3s/second
*Display:6000 counts LED display
*Overload: ‘OL’ displayed
*Low voltage display of battery: displayed when the working
voltage is low
*Input polarity indicator: shown automatically
*Battery:3 X1.5V AAA
*Size: 147mm (L)*71mm (W)*45mm (H)
*Weight: about 220g (battery excluded)
Accuracy index
Accuracy:±(%reading+digit),one year warranty from the manufacture
date
Conditions: surroundings temperature from 18℃ to 28℃,<80%RH
Operation instruction
Regular operation
The “HOLD” and “Hz” functions are on invalid mode if there is no input
and the functions recover when there has input.
Backlight and the torch function
The meter has backlight and illumination function for users’ convenient
reading of measuring results in the dark situations. To enter and exit this
mode,please operate as below:
1. Short press key to turn on backlight and short press again to exit. It
turns off automatically with no operation for 30S.
2. Long press to turn on the illumination function and the backlight at
the same time. Short press the key again to turn off the illumination
function. It turns off automatically with no operation for 30S.
3. When the backlight is on, press the key for 2S can start the
illumination too. Both them will be turned off with no operation for 30S.
Auto power off
After about 5 minutes after power on, if there is no operating
instrument, it will give audible voice prompts, will automatically cut off
the power, enter the hibernation mode, in the automatic shutdown
mode, any key can be restarted.
Do not measure any voltage greater than 600V to prevent electric
shock or damage to the instrument.
Do not apply more than600V voltage between the common and earth
to prevent electric shock or damage to the instrument.
ACV/DCV/Resistance/Frequency/Buzzer Measurement
1. Connect the black test pen to the COM jack and the red pen to the
jack.
2. Turn on the meter by pressing the power key.
3. Connect the test leads to the circuit to be tested, power or resistance.
The meter will judge the ACV, DCV or resistance automatically.
4. If the resistance of the circuit under test is not greater than about 50
ohms, the indicator light will turn on and the buzzer will sound
continuously.
5. The screen also shows the polarity of the red test pen when the DCV is
in measurement.
6. When the ACV is in measurement, the screen can show the frequency
of the ACV if key is pressed.
Capacitance/Diode /Temperature Manually Switch Measurement
1. Put the red test lead in , and press until the
is shown, it enters into the mode of testing the diode and the
reading shown is the voltage drop.
2. Put the red test lead in , and press until the
“nF” is shown, it enters into the mode of testing the capacitance and
the reading shown is the value of the capacitance.
3. Press until it shows C and it shows the room temperature
on the screen. Put the red temperature test lead in , it
shows the real temperature of the red test lead and press
again to get a F reading.
Now press the to keep the relative data.
Notes:
a. It needs a certain time to have stable readings while measureing a
relative large capacitance.
b. Pls take a note while measuring the capacitance with politaries to
avoid damage the meter.
ACA DCA measurement(identify the alternative and direct current
automatically. )
1. Put the black test lead into the “COM” and the read one into “10A”
2. Press the on/off power to turn on the power.
3. The red and black test lead should be in series in the circuit and the
reading can be read directly. Press the to keep the data.
NCV non contact voltage detection(“----” refers from strength to
weakness)
1. Turn on the meter by pressing the power key.
2. Press the continously and start detection when the “EF”is shown on
the LCD screen.
3. The NCV indicator flashes with buzzer when there is voltage on the
live wire.
4. The screen shows how strong the magnetic.
Note:
1. The voltage may still be there even if no flash with buzzer of NCV
indicator, which can be affected by the sockets designs or insulation
etc.
2. The outer factors such as flash lights or radar may cause NCV flashes.
Live Wire Identification (“----” refers from strength to weakness)
1. Connect the black test pen to the COM jack and the red pen to the
jack.
2. Turn on the meter by pressing the power key.
3. Press the continously and put the red or black test lead into the
live wire. If there is NCV flashes with buzzer then there is voltage on the
live wire.
4. The screen shows”----”,which is the strong electric field.
[Link] could happen on the socket with LED light in it .