0% found this document useful (0 votes)
70 views7 pages

AISI 304 Submersible Pumps Overview

The document details the specifications and features of the BEST 2-5 submersible pumps made of AISI 304 stainless steel, designed for sewage and water handling in various settings. It includes technical data such as maximum immersion depth, temperature, and solid passage capabilities, as well as information on materials and motor specifications. Additionally, it provides performance curves, dimensions, and installation options for both fixed and mobile applications.

Uploaded by

Vu Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views7 pages

AISI 304 Submersible Pumps Overview

The document details the specifications and features of the BEST 2-5 submersible pumps made of AISI 304 stainless steel, designed for sewage and water handling in various settings. It includes technical data such as maximum immersion depth, temperature, and solid passage capabilities, as well as information on materials and motor specifications. Additionally, it provides performance curves, dimensions, and installation options for both fixed and mobile applications.

Uploaded by

Vu Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

BEST 2-5

Submersible pumps in AISI 304 stainless steel


Submersible pumps used for handling sewage water, draining cellars, garages and basements, draining small and medium-sized
building sites. Thanks to their versatility, they can be used in permanent or portable installations.

Technical data

Max. immersion 7m

Max. temperature
of the liquid 35°C
(sewage water)
Max. solids
10 mm (suspended particles)
passage

Poles 2

Insulation class F

Protection degree IP68

Single phase 1~230V ± 10%


Voltage
Three phase 3~400V ±10%

Possibility to Permanent split capacitor built in overload motor protector with automatic reset.
use in fixed The three phase version does not have an internal motor protector, therefore
and mobile
installations overload protection must be provided by the user.

Materials Accessories

BEST 2-5
Pump
AISI 304 (EN 1.4301) Control panels
body
Page 437 - Control panels
Impeller AISI 304 (EN 1.4301) QA50/B - QA60/C - SMART - QM1
- QT1
AISI 303 (EN 1.4305) (part in contact with
Shaft
the liquid)
Installation
Mechanical upper in Carbon/Ceramic/NBR (motor side)
seal lower in SiC/SiC/NBR (pump side)

Identification code

BEST 3 M A
with float switch

Single phase
2
Type 3
BEST 2 - 5 pumps are also available with a float switch.
4
5 With this option, the flexibility of purpose of these pumps
Model are increased. However, the choice to using the float switch
requires minimum installation space to ensure the proper
operation of the pump.
Technical Data Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

Requested data
1 Pump type SUBMERSIBLE SUMP PUMPS Fluid Water
2 Number of pumps / Reserve 1 / 0 Liquid temperature °C 20
3 Flow l/min 100 Kin. viscosity mm²/s 1.005
4 Head m 10 Vapour pressure kPa 2.34
5 Geodetic head m 0 PH value
6 Inlet pressure (pin) kPa 0 Density kg/m³ 998.3
7 Available system NPSH Solids Weight % 0
8 Ambient temperature °C 20

Pump
9 Pump Name BEST 3 Frequency Hz 50
10 Design SUBMERSIBLE SUMP PUMPS Installation type Without switch (STANDARD)
11 Manufacturer EBARA Impeller Max. mm 120
12 Speed 1/min 2800 Diameter Designed mm 120
13 No. of Stage 1 Min. mm 120

14 Connection Suction side Strainer Flow Operating l/min 101


15 Connection Discharge side UNI ISO 228 Max- l/min 280

16 Max Working Pressure kPa Min- l/min 20


17 Shut-off head kPa 142.84 Head Operating m 10.2
18 Total weight kg See the table of "Dimensions". - (Qmax.) m 3.2
19 Shaft power kW - (Qmin.) m 13.6
20 Max. Shaft Power at max. impeller kW

21 Required pump NPSH m Efficiency %

Materials
22 Impeller AISI 304
23 Casing AISI 304
24 Shaft AISI 303 (wet extension)
25
26
27

Motor
28 Manufacturer EPE Standard Insulation class F
29 Type BEST3_400_Three Phase Phases 3~
30 Specific design Submersible dry type / 50 Hz / Pole pairs 1 Frame size
31 Rated power kW 0.75 Weight kg
32 Number of poles 2 Electric voltage V 400
33 Speed 1/min 2800 Electric current A 2.4
34 Degree of protection IP 68
35

Remarks
Performance Curve Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

Requested data Pump


1 Flow l/min 100 Operating flow l/min 101 Frequency Hz 50
2 Head m 10 Operating head m 10.2 Number of poles 2
3 Geodetic head m 0 Impeller diameter designed mm 120 Speed 1/min 2800

Test standard: ISO 9906:2012 - Grade3B Water; 20°C; 998.3kg/m³; 1mm²/s

H/ m Head — Ø 120

14

Frequency

12

10.23
10
A1

◄ Application range ►▏ 101.1


0

0 50 100 150 200 250 Q / l/min
Dimensions Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

Dimensions in mm

1 H 352
2 H1 315
3 Weight P&M 12,7 kg
4
5
6
7
8
9
10
11
12
13
14
15
(1/3)
Construction Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail
(2/3)
Construction Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail
(3/3)
Construction Pump Name BEST 3

Customer Date 2025-01-15 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

You might also like