The document provides instructions for configuring the Master BMS, including modifying parameters via a USB to RS485 module and ensuring correct settings to avoid safety issues. It details the software interface, parameter reading and writing processes, and the importance of calibration for accurate current readings. Users are advised to seek technical support if they encounter difficulties or if the default parameters do not meet their project requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
280 views6 pages

Top BMS

The document provides instructions for configuring the Master BMS, including modifying parameters via a USB to RS485 module and ensuring correct settings to avoid safety issues. It details the software interface, parameter reading and writing processes, and the importance of calibration for accurate current readings. Users are advised to seek technical support if they encounter difficulties or if the default parameters do not meet their project requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TOPBMS Company Website:www.cleverbms.

comÿwechat:+8617841591535

Master BMS Configuration Instruction


The program of the master is commonly used , and the configuration parameters of the master BMS
can be modified according to the requirements of the user. The user wants to modify the parameter
via the USB to RS485 module, a computer running the software for modifying configuration parameters
are required.
After the software is opened, the program will automatically show the serial ports of the computer.
After selecting the serial port, copen the serial port. If the serial port is occupied by other software,
a message is displayed indicating that the serial port is occupied.
Note: "Read" parameters before modifying them. After parameters modification, it is best to restart the software ,
and then read these parameters again
Check if the parameters are correct. Incorrect parameters may cause security accidents.
Therefore, precautions should be taken.
Note: Read parameters before modifying them. After parameter modification, it is best to restart the SW , after reading ,confirm the modified parameters are correct ;Incorrect parameters may cause security accidents. Therefore, precautions should be taken.

1>. The software interface is divided into left and right .


On the left there is window of batteries system parameter settings and
on the right there is window of BMS parameter settings

After clicking the "Read"button on the left, the system parameters in the BMS system will be displayed.
The first item is the current detection type:Shunt and Hall sensors. The second item is the RS485 port.
This port can be used to communicate with PC or connect display.
The third item is the inverter selection. In program 8 inverter protocols are flashed
TOPBMSsàmw^^gu5/&g–PQlSøwww.cleverbms.comÿwechat:+8617841591535

2>.Modify the configuration parameters based on customer requirements


For example, the project requires 8 slave BMS, each slave BMS control 12 cells in series,
a total of 96 cells in series and each slave control has temperature sensors.
Finally, the configuration of the whole project: 8 slave bms, total number of batteries strings 8*12=96,
Temp Sensors : 8*3=24. Master BMS does not have acquisition wires/balancing wires
1~8 Slave BMS: String number: 12S, temperature Sensor : 3. Then write the configuration parameters
in the master bms . After configuration parameters are written
The software will automatically re-read the parameters to see if there is any problem.
TOPBMSsàmw^^gu5/&g–PQlSøwww.cleverbms.comÿwechat:+8617841591535

3>.Modify inverter protocol in the program of AF_BMS MODBUS according to project requirements.
In CAN Type, select the inverter protocol in the drop-down list , and then write it the in the programm
TOPBMSsàmw^^gu5/&g–PQlSøwww.cleverbms.comÿwechat:+8617841591535
4>.Configuration Parameters :
If the configuration parameters written into the software are changed, the master BMS will
adjust the corresponding protection parameters according to the configuration parameters
If the configuration does not meet the project requirements, the client needs to modify the parameters
as required. After the modification, please write the protection parameter in the software again
Note: The configuration must be modified under the guidance of battery experts. Incorrect configuration
parameters may cause safetyaccidents, need to pay attention to the characteristics.

5>.In the debugging phase, if the displayed current is very different from the actual measured current,
you can modify the parameter to calibrate.

Operation Principle :
For hall sensor
The current collected by the sensor is multiplied by 100.0% coefficient to
obtain the current of the system. Sensor current *100.0%= Display current.

If the current is not correct, the actual charging current is 9.5A, and the charging current shown
by the computer software is 10A, and the coefficient is 100.0%. (When the calibration coefficient is
100.0%, the current of the sensor is 10A.) Adjust the calibration coefficient to 95.0%
Current calibration. (Current of sensor 10A*95.0%= display current 9.5A)
For Shunt, we do same things
TOPBMSsàmw^^gu5/&g–PQlSøwww.cleverbms.comÿwechat:+8617841591535

6>.Some configuration parameters are configured in the upper computer software by default.
Customers can select according to their needs and click Load.
The configuration parameters and protection parameters on the software interface will be updated to
the contents in the file. You need to write the configuration parameters first
TOPBMSsàmw^^gu5/&g–PQlSøwww.cleverbms.comÿwechat:+8617841591535

7>.If the customer does not understand how to set configuration and protection parameters, or
The configuration parameters in the software cannot meet the requirements
Client can contact our company's technical personnel, our company's technical personnel
can send a reference parameter file,