0% found this document useful (0 votes)
60 views29 pages

DHO924S Digital Oscilloscope Overview

The DHO900 series is RIGOL's new high-performance digital oscilloscope featuring ultra-low noise, 12-bit resolution, and a maximum sample rate of 1.25 GSa/s. It supports 4 analog and 16 digital channels, making it suitable for embedded design and testing, while offering advanced functions like waveform search and navigation. The series includes various probes and accessories to enhance its functionality, catering to R&D, education, and scientific research needs.

Uploaded by

Thalapathy Guru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views29 pages

DHO924S Digital Oscilloscope Overview

The DHO900 series is RIGOL's new high-performance digital oscilloscope featuring ultra-low noise, 12-bit resolution, and a maximum sample rate of 1.25 GSa/s. It supports 4 analog and 16 digital channels, making it suitable for embedded design and testing, while offering advanced functions like waveform search and navigation. The series includes various probes and accessories to enhance its functionality, catering to R&D, education, and scientific research needs.

Uploaded by

Thalapathy Guru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product Features

Product Features

• Ultra-low noise floor, purer signal, never miss the small signals
• Up to 12 bits resolution for all the models of this series
• Max. analog bandwidth of 250 MHz, 4 analog channels
• 16 digital channels (std.), logic probe required to be purchased if needed
• Max. real-time sample rate of 1.25 GSa/s
• Max. memory depth of 50 Mpts
• Vertical sensitivity range: 200 μV/div to 10 V/div
• Max. capture rate of 1,000,000 wfms/s (in UltraAcquire mode)
• Digital phosphor display with real-time 256-level intensity grading
• Integrates the AFG function, bode plot analysis, histogram, digital signal analysis, and etc
• Waveform search and navigation function allows you to debug the signal anomalies faster
• 7" (1024x600) capacitive multi-touch screen
• Brand new Flex Knob brings user-friendly experience
• USB Device & Host, LAN, and HDMI interfaces (std.) for all the models of this series
• Novel and delicate industrial design, easy to operate
• Unique online upgrade

The DHO900 series is RIGOL's new launched high-performance economical digital oscilloscope.
Though compact in design, it has superior performance. It features a capture rate up to 1,000,000
wfms/s (in UltraAcquire Mode), 50 Mpts memory depth, 12 bit resolution, and low noise.

The DHO900 series supports 16 digital channels. One instrument can make an analysis on both the
analog and digital signals to meet the embedded design and test scenarios. With an affordable
price equivalent to purchasing an entry-level instrument, you can access the auto serial and parallel
bus analysis, bode plot analysis, and other functions to meet the test demands in the R&D,
education, and scientific research fields.

Page 1
RIGOL Probes and Accessories
Supported
Model Type Description

Passive High-impedance Probe

• Attenuation Ratio: 10:1/1:1


• 1X BW: DC to 35 MHz
Passive High-
impedance Probe • 10X BW: DC to 150 MHz
• Compatibility: All models of RIGOL's digital
PVP2150 oscilloscopes

• Attenuation Ratio: 10:1/1:1


• 1X BW: DC to 35 MHz
Passive High-
impedance Probe • 10X BW: DC to 350 MHz
• Compatibility: All models of RIGOL's digital
PVP2350 oscilloscopes

• Attenuation Ratio: 10:1/1:1


• 1X BW: DC to 20 MHz
Passive High-
impedance Probe • 10X BW: DC to 150 MHz
• Compatibility: All models of RIGOL's digital
PVP3150 oscilloscopes

High-voltage Single-ended Probe

• Attenuation Ratio: 1000:1


• BW: DC to 40 MHz
• DC: 0 to 10 kV DC
High-voltage Probe • AC: pulse ≤20 kVp-p
• AC: sine ≤7 kVrms
RP1010H
• Compatibility: All models of RIGOL's digital
oscilloscopes

• Attenuation Ratio: 1000:1


• BW: DC to 150 MHz
• DC+ACpeak: 18 kV CAT II
High-voltage Probe
• ACrms: 12 kV CAT II
RP1018H • Compatibility: All models of RIGOL's digital
oscilloscopes

Page 2
Model Type Description

• Attenuation Ratio: 100:1


• BW: DC to 300 MHz
• CAT I 2000 V (DC+AC)
High-voltage Probe
• CAT II 1500 V (DC+AC)
• Compatibility: All models of RIGOL's digital
RP1300H oscilloscopes

High-voltage Differential Probe

• BW: DC~70 MHz


High-voltage • Max. voltage ≤ 1500 Vpp
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
PHA0150

• BW: DC~100 MHz


High-voltage • Max. voltage ≤ 1500 Vpp
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
PHA1150

• 50X BW: DC to 160 MHz


• 500X BW: DC to 200 MHz
High-voltage
Differential Probe • Max. voltage ≤ 1500 Vpp
• Compatibility: All models of RIGOL's digital
PHA2150 oscilloscopes

• BW: DC to 25 MHz
High-voltage • Max. voltage ≤ 1400 Vpp (DC + AC P-P)
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
RP1025D

• BW: DC to 50 MHz
High-voltage • Max. voltage ≤ 7000 Vpp (DC + AC P-P)
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
RP1050D

• BW: DC to 100 MHz


High-voltage • Max. voltage ≤ 7000 Vpp (DC + AC P-P)
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
RP1100D

Page 3
Model Type Description

Current Probe

• BW: DC to 300 kHz


• Maximum Input

AC: ±100 A
Current Probe AC P-P: 200 A

AC RMS: 70 A
RP1001C • Compatibility: All models of RIGOL's digital
oscilloscopes

• BW: DC to 1 MHz
• Maximum Input

AC: ±70 A
Current Probe AC P-P: 140 A

AC RMS: 50 A
RP1002C • Compatibility: All models of RIGOL's digital
oscilloscopes

• BW: DC to 50 MHz
• Maximum Input

AC P-P: 50 A (non-continuous)
Current Probe
AC RMS: 30 A
• Compatibility: All models of RIGOL's digital
RP1003C
oscilloscopes
• Required to order RP1000P power supply.

• BW: DC to 100 MHz


• Maximum Input

AC P-P: 50 A (non-continuous)
Current Probe
AC RMS: 30 A
• Compatibility: All models of RIGOL's digital
RP1004C
oscilloscopes
• Required to order RP1000P power supply.

• BW: DC to 10 MHz
• Maximum Input

AC P-P: 300 A (non-continuous), 500 A


(@pulse width ≤ 30 us)
Current Probe
AC RMS: 150 A
• Compatibility: All models of RIGOL's digital
RP1005C
oscilloscopes
• Required to order RP1000P power supply.

Page 4
Model Type Description

• BW: DC to 2 MHz
• Maximum Input

AC P-P: 700 A peaks, non-continuous


Current Probe
AC RMS: 500 A
• Compatibility: All models of RIGOL's digital
RP1006C oscilloscopes
• Required to order RP1000P power supply.

Power supply for RP1003C, RP1004C, RP1005C,


4CH Power Supply and RP1006C; supporting 4 channels.

RP1000P

Logic Analyzer Probe

• Logic analyzer probe (dedicated probe for


Logic Analyzer Probe
MSO5000 and DHO900 series)

PLA2216

Page 5
Specifications
All the specifications are guaranteed except the parameters marked with "Typical" and the
oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.
The specifications are measured when the oscilloscope is properly grounded.

Overview of the DHO900 Series Technical Specifications


Overview of the DHO900 Series Technical Specifications

Model DHO914 DHO914S DHO924 DHO924S

Analog Bandwidth
125 MHz 250 MHz
(-3 dB)

Rise Time
≤2.8 ns ≤1.4 ns
(10% to 90%, typical)

4 input analog channels

16 input digital channels (required to purchase the PLA2216 logic analyzer


No. of Input/Output
probe)
Channels
single-channel arbitrary function generator (AFG) output (only available for
the S model)

Sampling Mode Real-time Sampling

Max. Sample Rate of 1.25 GSa/s (single-channel[1]), 625 MSa/s (dual-channel[2]), 312.5 MSa/s
Analog Channel (full-channel[3])

50 Mpts (single-channel[1]), 25 Mpts (dual-channel[2]), 10 Mpts (full-


Max. Memory Depth
channel[3])

Max. Waveform 30,000 wfms/s (Vector Mode)


Capture Rate 1,000,000 wfms/s (UltraAcquire Mode)

Vertical Resolution 12 bits

Hardware Real-time
Waveform Recording Max. 500,000 frames
and Playing

Peak Detection Capture 1.6 ns glitches

LCD Size and Type 7'' capacitive multi-touch screen

Display Resolution 1024x600

Page 6
Vertical System Analog Channel
Vertical System Analog Channel

Input Coupling DC, AC, or GND

Input Impedance 1 MΩ ± 1%

Input Capacitance 15 pF ± 3 pF

0.001X, 0.002X, 0.005X, 0.01X, 0.02X, 0.05X, 0.1X, 0.2X, 0.5X,


Probe Attenuation 1X, 2X, 5X, 10X, 15X, 20X, 50X, 100X, 150X, 200X, 500X,
Coefficient 1000X, 1500X, 2000X, 5000X, 10000X, 15000X, 20000X, and
50000X

CAT I 300 Vrms, 400 Vpk (DC + Vpeak)

Maximum Input Whether the probe is used or not, the transient overvoltage
Voltage is not allowed to occur.
Remarks
Please use the instrument dedicated for the specified
measurement category (not applicable to CAT II, III, and IV)

Vertical Resolution 12 bits

Vertical Sensitivity
200 μV/div to 10 V/div
Range[4]

±0.5 V (<500 μV/div)

±1 V (≥500 μV/div, ≤65 mV/div)

Offset Range ±8 V (>65 mV/div, ≤270 mV/div)

±20 V (>270 mV/div, ≤2.75 V/div)

±100 V (>2.75 V/div, ≤10 V/div)

Dynamic Range ±4 div (12 bits)

Bandwidth Limit
20 MHz, FULL; selectable for each channel
(Typical)

± 1% (>5mV/div, FullScale)
DC Gain Accuracy[4]
± 2% (≤5mV/div, FullScale, Typ.)

≤200 mV/div (±0.1 div ± 2 mV ± 1.5% of offset value)


DC Offset Accuracy
>200 mV/div (±0.1 div ± 2 mV ± 1.0% of offset value)

Channel-to-Channel
≥100:1
Isolation

ESD Tolerance ±8 kV (on input BNCs)

Page 7
Vertical System Digital Channel
Vertical System Digital Channel

16 input channels (D0 to D15)


Number of Channels
(D0 to D7, D8 to D15)

Threshold Range ±15.0 V, in 10 mV step

Threshold Accuracy ±(100.00 mV + 3% of threshold setting)

TTL(1.4 V), CMOS5.0(2.5 V), CMOS3.3(1.65 V), CMOS2.5(1.25 V),


Threshold Selection CMOS1.8(0.9 V), ECL(-1.3 V), PECL(3.7 V), LVDS(1.2 V), 0.0V
User (threshold adjustable for a single channel)

Max. Input Voltage ±40 V peak CAT I; transient overvoltage 800 Vpk

Max. Input Dynamic Range ±10 V + threshold

Minimum Voltage Swing 500 mVpp

Input Impedance about 101 kΩ

Probe Load about 8 pF

Vertical Resolution 1 bits

Horizontal System--Analog Channel


Horizontal System--Analog Channel

2 ns/div to 500 s/div


Range of Time Base
Fine

Time Base Resolution 100 ps

Time Base Accuracy ±25 ppm ± 5 ppm/year

Pre-trigger -5 div
Time Base Delay Range
Post-trigger 1 s or 100 div, whichever is greater

±(Time Base Accuracy x Readout) ± (0.001 x Screen Width)


Delta Time Accuracy
± 20 ps

Channel-to-Channel
±100 ns, Accuracy ± 1 ps
Skew Correction

Analog Channel-to-Channel Delay


≤2 ns
(Typical)[5]

Page 8
Horizontal System--Analog Channel

YT Default

XY Channel 1/2/3/4

Horizontal Mode
SCAN Time base ≥200 ms/div

Time base ≥50 ms/div, available to enter or exit the ROLL


ROLL
mode by adjusting the horizontal timebase knob

Horizontal System--Digital Channel


Horizontal System--Digital Channel

Min. Detectable Pulse Width 5 ns

200 MHz (accurately copied as the sine wave of the maximum


frequency of the logic square wave; input amplitude is the
Maximum Input Frequency
minimum swing; the shortest the ground cable is required for the
logic probe)

Channel-to-Channel Skew
±5 ns
(Typical)[6]

Acquisition System
Acquisition System

Max. Sample Rate of 1.25 GSa/s (single-channel[1]), 625 MSa/s (dual-channel[2]), 312.5 MSa/s
Analog Channel (full-channel[3])

Max. Memory Depth 50 Mpts (single-channel[1]), 25 Mpts (dual-channel[2]), 10 Mpts (full-


of Analog Channel channel[3])

Normal Default

Peak
Capture 1.6 ns glitches
Detection
Acquisition Mode
Average
2, 4, 8, 16…65536 are available for you to choose
Type

UltraAcquire Waveform capture rate up to 1,000,000 wfms/s

Page 9
Trigger System
Trigger System

Trigger Source Analog channel (CH1 to CH4), digital channel (D0 to D15)

Trigger Mode Auto, Normal, Single

DC DC coupling trigger

AC AC coupling trigger

High
Trigger Coupling
Frequency Cut-off frequency to 120 kHz (internal trigger only)
Rejection

Low Frequency
Cut-off frequency to 120 kHz (internal trigger only)
Rejection

Increases delay for the trigger circuit (internal trigger only),


Noise Rejection
On/Off

Holdoff Range 8 ns to 10 s

Trigger
Internal trigger: analog bandwidth of the oscilloscope
Bandwidth

Internal trigger: 0.5 div, ≥50 mV/div; 0.7 div (with noise
Trigger Sensitivity
rejection enabled)

Trigger Level
Internal trigger: ±4.5 div from the center of the screen
Range

Trigger Type
Trigger Type

Edge trigger, Pulse trigger, Slope trigger, Video trigger, Pattern trigger,
Trigger Type Duration trigger, Timeout trigger, Runt trigger, Window trigger, Delay trigger,
Setup/Hold trigger, Nth Edge trigger, RS232/UART, I2C, SPI, CAN, and LIN

Triggers on the threshold of the specified edge of the input signal. The edge
Edge types can be Rising, Falling, or Either.
Source channel: CH1 to CH4, D0 to D15

Triggers on the positive or negative pulse with a specified width. The pulse
Pulse width is greater or smaller than a certain value or within a certain time range.
Source channel: CH1 to CH4, D0 to D15

Page 10
Trigger Type

Triggers on the positive or negative slope of the specified time. The slew time
Slope is greater or smaller than a certain value or within a certain time range.
Source channel: CH1 to CH4

Triggers on all lines, specified line, odd field, or even field that conforms to the
video standards. The supported video standards include NTSC, PAL/SECAM,
480p/60Hz, 576p/50Hz, 720p/60Hz, 720p/50Hz, 720p/30Hz, 720p/25Hz, 720p/
Video
24Hz, 1080p/60Hz, 1080p/50Hz, 1080p/30Hz, 1080p/25Hz, 1080p/24Hz, 1080i/
60Hz, and 1080i/50Hz.
Source channel: CH1 to CH4

Identifies a trigger condition by searching for a specified pattern. The pattern is


a combination of multiple selected channel sources. The logic pattern of each
Pattern
channel is H, L, X, Rising, or Falling.
Source channel: CH1 to CH4, D0 to D15

Triggers when the specified pattern meets the specified duration condition.
The pattern is a combination of multiple selected channel sources. The logic
Duration pattern of each channel is H, L, and X. The duration is greater or smaller than a
certain value, or within a certain time range, or outside a certain time range.
Source channel: CH1 to CH4, D0 to D15

Triggers when duration of a certain event exceeds the specified time. The event
Timeout can be specified as Rising, Falling, or Either.
Source channel: CH1 to CH4, D0 to D15

Triggers when the pulses pass through one threshold but fail to pass through
Runt another threshold.
Source channel: CH1 to CH4

Triggers in a specified window state when the rising edge of the signal crosses
the upper threshold or the falling edge crosses the lower threshold. The
Window
window state can be Enter, Exit, or Time.
Source channel: CH1 to CH4

Triggers when the time difference between the specified edges of Source A
and Source B meets the preset time. The duration is greater or smaller than a
Delay
certain value, or within a certain time range, or outside a certain time range.
Source channel: CH1 to CH4, D0 to D15

When the setup time or hold time between the input clock signal and the data
Setup/Hold signal is smaller than the specified time.
Source channel: CH1 to CH4, D0 to D15

Triggers on the Nth edge that appears after the specified idle time. The edge
Nth Edge can be specified as Rising or Falling.
Source channel: CH1 to CH4, D0 to D15

Page 11
Trigger Type

Triggers on the Start, Error, Check Error, or Data frame of the RS232/UART bus
RS232/UART (up to 20 Mb/s).
Source channel: CH1 to CH4, D0 to D15

Triggers on the Start, Stop, Restart, MissedACK, Address (7 bits, 8 bits, or 10


I2C bits), Data, or Address Data of the I2C bus.
Source channel: CH1 to CH4, D0 to D15

Triggers on the specified pattern of the specified data width (4 to 32) of SPI
SPI bus. CS and Timeout are supported.
Source channel: CH1 to CH4, D0 to D15

Triggers on the start of a frame, end of a frame, Remote ID, Overload, Frame ID,
Frame Data, Data&ID, Frame Error, Answer Error, Check Error, Format Error, Bit
CAN Fill, and Random of the CAN signal (up to 5Mb/s). The supported CAN bus
signal types include CAN_H, CAN_L, TX/RX, and DIFF.
Source channel: CH1 to CH4, D0 to D15

Triggers on the Sync, ID, Data (length settable), Data&ID, Wakeup, Sleep, and
LIN Error of the LIN bus signal (up to 20 Mb/s).
Source channel: CH1 to CH4, D0 to D15

Search&Navigation
Search&Navigation

Type Edge, Pulse

Source Analog channel

Copies the search settings from or to the trigger settings mutually, including
Copy
threshold setting and search condition settings

Displays in event table form; can be exported to the external or internal


Result Display
memory

Time navigation: navigates to the acquired waveforms in time order.

Event navigation: uses the navigation keys to scroll through the event search
Navigation results and navigates to the specified event.

Frame navigation: navigates to the specified frame segment in UltraAcquire


mode.

Page 12
Waveform Measurement
Waveform Measurement

Number of
2 pairs of XY cursors
Cursors

Voltage deviation between cursors (∆Y)


Manual Mode Time deviation between cursors (∆X)
Reciprocal of ∆X (Hz) (1/∆X)

Fixes Y-axis to track X-axis waveform point's voltage and time


Track Mode values
Cursor
Fixes X-axis to track Y-axis waveform point's voltage and time
values

Auto
Allows to display cursors during auto measurement
Measurement

Measures the voltage parameters of the corresponding


XY Mode channel waveforms in XY time base mode.
X = Channel 1, Y = Channel 2

Number of 41 auto measurements; and up to 10 measurements can be


Measurements displayed at a time.

Measurement
CH1 to CH4, D0 to D15, Math1 to Math4
Source

Measurement
Range Main, Zoom
(Region)

Displays 33 measurement items (vertical and horizontal) for


All
the current measurement channel; the measurement results
Auto Measurement
are updated continuously.
Measurement

Vmax, Vmin, Vpp, Vtop, Vbase, Vamp, Vupper, Vmid, Vlower,


Vertical Vavg, VRMS, Per. VRMS, Overshoot, Preshoot, Area, and Period
Area.

Period, Frequency, Rise Time, Fall Time, +Width, -Width, +Duty,


-Duty, Positive Pulse Count, Negative Pulse Count, Rising Edge
Horizontal
Count, Falling Edge Count, Tvmax, Tvmin, +Slew Rate, and -
Slew Rate

Delay(A↑-B↑), Delay(A↑-B↓), Delay(A↓-B↑), Delay(A↓-B↓),


Others
Phase(A↑-B↑), Phase(A↑-B↓), Phase(A↓-B↑), and Phase(A↓-B↓)

Page 13
Waveform Calculation
Waveform Calculation

No. of Math Functions 4 math functions available to be displayed at a time

A+B, A-B, A×B, A/B, FFT, A&&B, A||B, A^B, !A, Intg, Diff, Sqrt,
Operation Lg, Ln, Exp, Abs, AX+B, LowPass, HighPass, BandPass, and
BandStop

Color Grade Supports FFT

Max. 1 Mpts (The max. number of the points to be analyzed


Record Length
for the FFT operation is 1 Mpts.)

Rectangular, Blackman-Harris, Hanning (default), Hamming,


FFT Window Type
Flattop, and Triangle.

A maximum of 15 peaks, determined by the user-defined


Peak Search
threshold and offset threshold

Waveform Analysis
Waveform Analysis

Stores the signal under test in segments according to the


trigger events, that is, saves all the sampled waveform data as
a segment to the RAM for each trigger event. The maximum
number of the sampled segments reaches 500,000.
Waveform
Recording Source All enabled analog channels

Support playing frame by frame or continuous playing;


Analysis capable of calculating, measuring, and decoding the played
waveforms

Compares the signal under test with the user-defined mask to


provide the test results: the number of successful tests, failed
tests, and the total number of tests. The pass/fail event can
PassFail
enable immediate stop, beeper, and the screenshot.

Source Any analog channel

Page 14
Waveform Analysis

The waveform histogram provides a group of data, showing


the number of times a waveform hits within the defined region
range on the screen. The waveform histogram not only shows
the distribution of hits, but also the ordinary measurement
statistics.

Source Any analog channel, auto measurement item


Histogram
Type Horizontal, vertical, and measure

Statistics: Sum, Peaks, Max, Min, Pk_Pk


Measure
Histogram: Mean, Median, Mode, Bin width, Sigma, and XScale

Sampling
Supports all modes, except the Zoom, XY, and ROLL modes
Mode

Provides a dimensional view for waveform intensity, color


grade >16, 256-level color scale display

Source Any analog channel


Color Grade
Color Theme Temperature and intensity

Sampling
Supports all modes
Mode

Serial Decoding
Serial Decoding

Number of
4 protocol types can be decoded and enabled at the same time
Decodings

Decoding Type Standard: Parallel, RS232/UART, I2C, SPI, CAN, and LIN

Up to 4 bits of Parallel decoding, supporting any analog channel Support user-


Parallel defined clock and auto clock settings.

Source channel: CH1 to CH4, D0 to D15

Decodes the RS232/UART (up to 20 Mb/s) bus's TX/RX data (5-9 bits), parity
RS232/UART (Odd, Even, or None), and stop bits (1-2 bits)

Source channel: CH1 to CH4, D0 to D15

Decodes the address (with or without the R/W bit) of the I2C bus, data, and
I2C ACK.

Source channel: CH1 to CH4, D0 to D15

Page 15
Serial Decoding

Decodes the MISO/MOSI data (4-32 bits) of the SPI bus. The available mode
SPI includes "Timeout" and "CS".

Source channel: CH1 to CH4, D0 to D15

Decodes the remote frame (ID, byte number, CRC), overload frame, and data
frame (standard/extended ID, control domain, data domain, CRC, and ACK) of
CAN the CAN bus (up to 5 Mb/s). The supported CAN bus signal types include
CAN_H, CAN_L, TX/RX, and DIFF.
Source channel: CH1 to CH4, D0 to D15

Decodes the protocol version (1.X or 2.X) of the LIN bus (up to 20 Mb/s). The
LIN decoding displays sync, ID, data, and check sum.
Source channel: CH1 to CH4, D0 to D15

Bode Plot[7]
Bode Plot

Start Freq 10 Hz to 24.99 MHz

Stop Freq[8] 100 Hz to 25 MHz

Number of Points
10 to 300
per Octave

Output Amplitude 20 mV to 5 V

Arbitrary Function Generator (AFG)[7]


AFG (technical specifications are typical values)

Number of
1
Channels

Output Mode Normal (Single-channel output)

Sample Rate 156 MSa/s

Vertical Resolution 14 bits

Max. Frequency 25 MHz

Standard Waveform: Sine, Square, Ramp, DC, Noise


Output Waveform
User-defined waveform: supported

Page 16
AFG (technical specifications are typical values)

Frequency Range 2 mHz to 25 MHz

Flatness ±0.5 dB (relative to 1 kHz)

Harmonic
-40 dBc
Distortion

Sine
Spurious (non-
-40 dBc
harmonics)

Total Harmonic
<1%
Distortion

S/N Ratio 40 dB

Frequency Range 2 mHz to 15 MHz

Rise/Fall Time <15 ns

Square Overshoot <5%

Duty 1% to 99%, adjustable

Jitter 500 ps

Frequency Range 2 mHz to 150 kHz

Ramp Linearity 1%

Symmetry 0 to 100%

Noise Frequency Range 25 MHz analog bandwidth

Frequency Range 2 mHz to 10 MHz

Arbitrary Waveform Length 2 pts to 16 kpts


Waveform

Supports loading the stored waveforms

Accuracy 100 ppm


Frequency
Resolution 0.1 Hz or 4 bits (whichever is greater)

2 mV to 10 V (frequency ≤ 10 MHz)
Output Range
2 mV to 5 V (frequency > 10 MHz)
Amplitude
Resolution 100 µV or 3 bits (whichever is greater)

Accuracy ±(2% of setting + 1 mV) (Frequency = 1 kHz)

Page 17
AFG (technical specifications are typical values)

Range -5 V to 5 V

DC Offset Resolution 100 µV or 3 bits (whichever is greater)

Accuracy ±(2% of offset setting + 5 mV + 0.5% of amplitude)

Modulating Waveform: Sine, Square, Triangle, Up Ramp,


Down Ramp, and Noise.

Carrier Waveform: Sine, Square, Ramp


AM
Modulation Source: Internal

Modulation Depth: 0% to 120%

Modulation Frequency: 2 mHz to 1 MHz

Modulating Waveform: Sine, Square, Triangle, Up Ramp,


Down Ramp, and Noise.

Carrier Waveform: Sine, Square, Ramp

Modulation Source: Internal


Modulation FM
Frequency Deviation: 2 mHz to set carrier frequency
(limited by the carrier frequency setting; the sum of the
frequency deviation and carrier frequency shall not exceed
the upper limit of the carrier frequency)

Modulation Frequency: 2 mHz to 1 MHz

Modulating Waveform: Sine, Square, Triangle, Up Ramp,


Down Ramp, and Noise.

Carrier Waveform: Sine, Square, Ramp


PM
Modulation Source: Internal

Phase Deviation: 0° to 360°, default 90°

Modulation Frequency: 2 mHz to 1 MHz

Auto
Auto

AutoScale Min voltage > 10 mVpp, duty cycle > 1%, frequency > 35 Hz

Digital Voltmeter
Digital Voltmeter

Source Any analog channel

Function DC, AC+DCrms, ACrms

Page 18
Digital Voltmeter

Resolution ACV/DCV: 3 digits

Limits Beeper Sounds an alarm when the voltage value is within or outside of the limit range

High-precision Frequency Counter


High-precision Frequency Counter

Source Any analog channel

Measure Frequency, period, totalizer

Resolution 3-6 digits, user-defined


Counter
Max. Frequency Max. analog bandwidth

48-bit totalizer
Totalizer
Counts the number of the rising edges

Time Reference Internal reference

Command Set
Command Set

Common Commands Support IEEE488.2 Standard

Error Message Definition Error messages

Support Status Report Mechanism Status Reporting

Support Syn Mechanism Synchronization

Display
Display

LCD 7-inch capacitive multi-touch screen, gesture enabled


operation

Resolution 1024×600 (Screen Region) 16:9

Graticule 10 horizontal divisions x 8 vertical divisions

Persistence Off, Infinite, variable persistence (100 ms to 10 s)

Brightness 256 intensity levels (LCD, HDMI)

Page 19
Processor System
Processor System

Processor Cortex-A72 up to 1.8 GHz, 6-core processor

System Memory 4 GB RAM

Operating System Android

Internal Non-volatile Memory 8 GB

I/O
I/O

USB2.0 Host 1 on the front panel

USB2.0 Device 1 on the rear panel

LAN 1 on the rear panel, 10/100 Base-T, supporting LXI-C

Supports Web Control interface (input the IP address of


Web Remote
the oscilloscope into the Web browser to display the
Control
operation interface of the oscilloscope)

AFG OUT[7] Waveform Output 1 on the rear panel, BNC connector

1 on the rear panel, BNC connector

Output Interface Vo (H) ≥ 2.5 V open circuit, ≥1.0 V 50 Ω to GND

Vo (L) ≤ 0.7 V to load ≤4 mA, ≤0.25 V 50 Ω to GND

AUX OUT
Trigger Output Outputs a pulse signal when the oscilloscope is triggered

Output a pulse signal when a pass/fail event occurs.


Pass/Fail Supports user-defined pulse polarity and pulse time (100
ns to 10 ms)

1 on the rear panel, HDMI 1.4, A plug. It is used to connect


HDMI Video Output
to an external monitor or projector

Probe
Compensation 1 kHz, 3 Vpp square waveform
Output

Page 20
Power Supply
Power Supply

Power Supply
Type-C
Interface

Power Voltage DC 15 V, 3 A

Max. 45 W (when connected to various interfaces, USB storage device, active


Power
probes)

Environment
Environment

Operating 0℃ to 50℃
Temperature
Range
Non-operating -30℃ to +60℃

below +30℃: ≤90% RH (without condensation)

Operating +30℃ to +40℃, ≤75% RH (without condensation)


Humidity Range
+40℃ to +50℃, ≤45% RH (without condensation)

Non-operating below 60℃: ≤90% RH (without condensation)

Operating below 3,000 m


Altitude
Non-operating Below 15,000 m

Warranty and Calibration Interval


Warranty and Calibration Interval

Warranty Three years for the mainframe, excluding the probes and accessories.

Recommended
18 months
Calibration Interval

Page 21
Regulations
Regulations

Compliant with EMC DIRECTIVE 2014/30/EU, compliant with or higher than


the standards specified in IEC 61326-1:2013/EN 61326-1:2013 Group 1 Class
A

CISPR 11/EN 55011

IEC 61000-4-2:2008/EN ±4.0 kV (contact discharge), ±8.0 kV (air


61000-4-2 discharge)

IEC 61000-4-3:2002/EN 3 V/m (80 MHz to 1 GHz); 3 V/m (1.4 GHz to


61000-4-3 2 GHz); 1 V/m (2.0 GHz to 2.7 GHz)

Electromagnetic IEC 61000-4-4:2004/EN


Compatibility 1 kV power line
61000-4-4

0.5 kV (phase-to-neutral voltage); 1 kV


IEC 61000-4-5:2001/EN
(phase-to-earth voltage); 1 kV (neutral-to-
61000-4-5
earth voltage)

IEC 61000-4-6:2003/EN
3 V, 0.15-80 MHz
61000-4-6

Voltage dip: 0% UT during half cycle; 0% UT


IEC 61000-4-11:2004/EN during 1 cycle ; 70% UT during 25 cycles
61000-4-11
short interruption: 0% UT during 250 cycles

EN 61010-1:2019

EN 61010-031:2015

IEC 61010-1:2016

IEC 61010-2-030:2017

Safety UL 61010-1:2012 R7

UL 61010-2-31:2017 R2

CAN/CSA-22.2 No. 61010-1-12:2017

CAN/CSA-22.2 No. 61010-2-30:2018

CAN/CSA-22.2 No. 61010-031-07:201

Meets GB/T 6587; class 2 random


Vibration
Meets MIL-PRF-28800F and IEC60068-2-6; class 3 random

Page 22
Regulations

Meets GB/T 6587-2012; class 2 random

Meets MIL-PRF-28800F and IEC 60068-2-27; class 3 random


Shock
In non-operating conditions: 30 g, half-sine wave, 11 ms duration, 3 shocks
along the main axis, total of 18 shocks

Mechanical Characteristics
Mechanical Characteristics

Dimensions 265.35 mm (W) x 161.75 mm (H) x 77.38 mm (D)

Package excluded: 1.78 kg


Weight[9]
Package included: 2.78 kg

Non-volatile Memory
Non-volatile Memory

Setup/Image setup (*.stp), image (*.png, *.bmp, *.jpg)

Data/File Storage CSV waveform data (*.csv), binary waveform data


Waveform Data (*.bin,), list data (*.csv), and reference waveform data
(*.ref, *.csv, *.bin)

Internal Capacity 8 GB

Reference Waveform Displays 10 internal waveforms

Setting Storage is limited by the capacity

Supports the USB storage device that conforms to the


USB Capacity
industry standard

Note:
[1]: Single-channel mode: If any one of the channels is enabled, it is called single-channel mode.
[2]: Dual-channel mode: if any two of the channels are enabled, it is called dual-channel mode.
[3]: Full-channel mode: if any three channels or all of the four channels are enabled, it is called full-channel mode.
[4]: 200 μV/div and 500 μV/div is a magnification of 1 mV/div setting. For vertical accuracy calculations, use full scale of 8 mV.
[5]: For any channel, under the same input impedance with DC-coupled, the Volts/div setting is the same for 100 mV/div and
200 mV/div.
[6]: Channel-to-Channel skew is ±5 ns when the sample rate on the digital channel is 625 MSa/s and the period is 1.6 ns.
[7]: Only DHO914S and DHO924S models are equipped with the Bode plot and AFG function.
[8]: The stop frequency shall be greater than the start frequency.
[9]: Standard configuration.

Page 23
Order Information and Warranty
Period

Order Information

Order Information Order No.

Model

250 MHz, 1.25 GSa/s, 50 Mpts, 4CH DHO924S

250 MHz, 1.25 GSa/s, 50 Mpts, 4CH DHO924

125 MHz, 1.25 GSa/s, 50 Mpts, 4CH DHO914S

125 MHz, 1.25 GSa/s, 50 Mpts, 4CH DHO914

Standard Accessories
Power Adaptor Conforming to the Standard of the Destination ——
Country

Banana-Plug Ground Connecting Cable ——

DHO924/DHO924S: Passive Probe x4 (350 MHz) PVP2350

DHO914/DHO914S: Passive Probe x4 (150 MHz) PVP3150

Recommended Accessories

16-channel Logic Analyzer Probe PLA2216

NOTE:

For all the mainframes, accessories and options, please contact the local office of RIGOL.

Warranty Period

Three years for the mainframe, excluding the probes and accessories.

Page 24
Option Ordering and Installation
Process

1. According to the usage requirements, please purchase the specified function options from RIGOL

Sales Personnel, and provide the serial number of the instrument that needs to install the option.

2. After receiving the option order, the RIGOL factory will mail the paper software product

entitlement certificate to the address provided in the order.

3. Log in to RIGOL official website for registration. Use the software key and instruments serial

number provided in the entitlement certificate to obtain the option license code and the option

license file.

4. Install the option by running the SCPI command concerning the option installation. You can also

save the option license file to the root directory of the USB storage device. Then insert it to the

instrument. After being recognized, follow the instructions to install the option.

NOTE:
If any problems occur during the option installation process, please contact RIGOL technical team.

Page 25