Product Features
• Ultra-low noise floor, purer signal, never miss the small signals
• Up to 12 bits resolution for all the models of this series
• Max. analog bandwidth of 250 MHz, 4 analog channels
• 16 digital channels (std.), logic probe required to be purchased if needed
• Max. real-time sample rate of 1.25 GSa/s
• Max. memory depth of 50 Mpts
• Vertical sensitivity range: 200 μV/div to 10 V/div
• Max. capture rate of 1,000,000 wfms/s (in UltraAcquire mode)
• Digital phosphor display with real-time 256-level intensity grading
• Integrates the AFG function, bode plot analysis, histogram, digital signal analysis, and etc
• Waveform search and navigation function allows you to debug the signal anomalies faster
• 7" (1024x600) capacitive multi-touch screen
• Brand new Flex Knob brings user-friendly experience
• USB Device & Host, LAN, and HDMI interfaces (std.) for all the models of this series
• Novel and delicate industrial design, easy to operate
• Unique online upgrade
The DHO900 series is RIGOL's new launched high-performance economical digital oscilloscope.
Though compact in design, it has superior performance. It features a capture rate up to 1,000,000
wfms/s (in UltraAcquire Mode), 50 Mpts memory depth, 12 bit resolution, and low noise.
The DHO900 series supports 16 digital channels. One instrument can make an analysis on both the
analog and digital signals to meet the embedded design and test scenarios. With an affordable
price equivalent to purchasing an entry-level instrument, you can access the auto serial and parallel
bus analysis, bode plot analysis, and other functions to meet the test demands in the R&D,
education, and scientific research fields.
Page 1
RIGOL Probes and Accessories
Supported
Model Type Description
Page 2
Model Type Description
• BW: DC to 25 MHz
High-voltage • Max. voltage ≤ 1400 Vpp (DC + AC P-P)
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
RP1025D
• BW: DC to 50 MHz
High-voltage • Max. voltage ≤ 7000 Vpp (DC + AC P-P)
Differential Probe • Compatibility: All models of RIGOL's digital
oscilloscopes
RP1050D
Page 3
Model Type Description
Current Probe
AC: ±100 A
Current Probe AC P-P: 200 A
AC RMS: 70 A
RP1001C • Compatibility: All models of RIGOL's digital
oscilloscopes
• BW: DC to 1 MHz
• Maximum Input
AC: ±70 A
Current Probe AC P-P: 140 A
AC RMS: 50 A
RP1002C • Compatibility: All models of RIGOL's digital
oscilloscopes
• BW: DC to 50 MHz
• Maximum Input
AC P-P: 50 A (non-continuous)
Current Probe
AC RMS: 30 A
• Compatibility: All models of RIGOL's digital
RP1003C
oscilloscopes
• Required to order RP1000P power supply.
AC P-P: 50 A (non-continuous)
Current Probe
AC RMS: 30 A
• Compatibility: All models of RIGOL's digital
RP1004C
oscilloscopes
• Required to order RP1000P power supply.
• BW: DC to 10 MHz
• Maximum Input
Page 4
Model Type Description
• BW: DC to 2 MHz
• Maximum Input
RP1000P
PLA2216
Page 5
Specifications
All the specifications are guaranteed except the parameters marked with "Typical" and the
oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.
The specifications are measured when the oscilloscope is properly grounded.
Analog Bandwidth
125 MHz 250 MHz
(-3 dB)
Rise Time
≤2.8 ns ≤1.4 ns
(10% to 90%, typical)
Max. Sample Rate of 1.25 GSa/s (single-channel[1]), 625 MSa/s (dual-channel[2]), 312.5 MSa/s
Analog Channel (full-channel[3])
Hardware Real-time
Waveform Recording Max. 500,000 frames
and Playing
Page 6
Vertical System Analog Channel
Vertical System Analog Channel
Input Impedance 1 MΩ ± 1%
Input Capacitance 15 pF ± 3 pF
Maximum Input Whether the probe is used or not, the transient overvoltage
Voltage is not allowed to occur.
Remarks
Please use the instrument dedicated for the specified
measurement category (not applicable to CAT II, III, and IV)
Vertical Sensitivity
200 μV/div to 10 V/div
Range[4]
Bandwidth Limit
20 MHz, FULL; selectable for each channel
(Typical)
± 1% (>5mV/div, FullScale)
DC Gain Accuracy[4]
± 2% (≤5mV/div, FullScale, Typ.)
Channel-to-Channel
≥100:1
Isolation
Page 7
Vertical System Digital Channel
Vertical System Digital Channel
Max. Input Voltage ±40 V peak CAT I; transient overvoltage 800 Vpk
Pre-trigger -5 div
Time Base Delay Range
Post-trigger 1 s or 100 div, whichever is greater
Channel-to-Channel
±100 ns, Accuracy ± 1 ps
Skew Correction
Page 8
Horizontal System--Analog Channel
YT Default
XY Channel 1/2/3/4
Horizontal Mode
SCAN Time base ≥200 ms/div
Channel-to-Channel Skew
±5 ns
(Typical)[6]
Acquisition System
Acquisition System
Max. Sample Rate of 1.25 GSa/s (single-channel[1]), 625 MSa/s (dual-channel[2]), 312.5 MSa/s
Analog Channel (full-channel[3])
Normal Default
Peak
Capture 1.6 ns glitches
Detection
Acquisition Mode
Average
2, 4, 8, 16…65536 are available for you to choose
Type
Page 9
Trigger System
Trigger System
Trigger Source Analog channel (CH1 to CH4), digital channel (D0 to D15)
DC DC coupling trigger
AC AC coupling trigger
High
Trigger Coupling
Frequency Cut-off frequency to 120 kHz (internal trigger only)
Rejection
Low Frequency
Cut-off frequency to 120 kHz (internal trigger only)
Rejection
Holdoff Range 8 ns to 10 s
Trigger
Internal trigger: analog bandwidth of the oscilloscope
Bandwidth
Internal trigger: 0.5 div, ≥50 mV/div; 0.7 div (with noise
Trigger Sensitivity
rejection enabled)
Trigger Level
Internal trigger: ±4.5 div from the center of the screen
Range
Trigger Type
Trigger Type
Edge trigger, Pulse trigger, Slope trigger, Video trigger, Pattern trigger,
Trigger Type Duration trigger, Timeout trigger, Runt trigger, Window trigger, Delay trigger,
Setup/Hold trigger, Nth Edge trigger, RS232/UART, I2C, SPI, CAN, and LIN
Triggers on the threshold of the specified edge of the input signal. The edge
Edge types can be Rising, Falling, or Either.
Source channel: CH1 to CH4, D0 to D15
Triggers on the positive or negative pulse with a specified width. The pulse
Pulse width is greater or smaller than a certain value or within a certain time range.
Source channel: CH1 to CH4, D0 to D15
Page 10
Trigger Type
Triggers on the positive or negative slope of the specified time. The slew time
Slope is greater or smaller than a certain value or within a certain time range.
Source channel: CH1 to CH4
Triggers on all lines, specified line, odd field, or even field that conforms to the
video standards. The supported video standards include NTSC, PAL/SECAM,
480p/60Hz, 576p/50Hz, 720p/60Hz, 720p/50Hz, 720p/30Hz, 720p/25Hz, 720p/
Video
24Hz, 1080p/60Hz, 1080p/50Hz, 1080p/30Hz, 1080p/25Hz, 1080p/24Hz, 1080i/
60Hz, and 1080i/50Hz.
Source channel: CH1 to CH4
Triggers when the specified pattern meets the specified duration condition.
The pattern is a combination of multiple selected channel sources. The logic
Duration pattern of each channel is H, L, and X. The duration is greater or smaller than a
certain value, or within a certain time range, or outside a certain time range.
Source channel: CH1 to CH4, D0 to D15
Triggers when duration of a certain event exceeds the specified time. The event
Timeout can be specified as Rising, Falling, or Either.
Source channel: CH1 to CH4, D0 to D15
Triggers when the pulses pass through one threshold but fail to pass through
Runt another threshold.
Source channel: CH1 to CH4
Triggers in a specified window state when the rising edge of the signal crosses
the upper threshold or the falling edge crosses the lower threshold. The
Window
window state can be Enter, Exit, or Time.
Source channel: CH1 to CH4
Triggers when the time difference between the specified edges of Source A
and Source B meets the preset time. The duration is greater or smaller than a
Delay
certain value, or within a certain time range, or outside a certain time range.
Source channel: CH1 to CH4, D0 to D15
When the setup time or hold time between the input clock signal and the data
Setup/Hold signal is smaller than the specified time.
Source channel: CH1 to CH4, D0 to D15
Triggers on the Nth edge that appears after the specified idle time. The edge
Nth Edge can be specified as Rising or Falling.
Source channel: CH1 to CH4, D0 to D15
Page 11
Trigger Type
Triggers on the Start, Error, Check Error, or Data frame of the RS232/UART bus
RS232/UART (up to 20 Mb/s).
Source channel: CH1 to CH4, D0 to D15
Triggers on the specified pattern of the specified data width (4 to 32) of SPI
SPI bus. CS and Timeout are supported.
Source channel: CH1 to CH4, D0 to D15
Triggers on the start of a frame, end of a frame, Remote ID, Overload, Frame ID,
Frame Data, Data&ID, Frame Error, Answer Error, Check Error, Format Error, Bit
CAN Fill, and Random of the CAN signal (up to 5Mb/s). The supported CAN bus
signal types include CAN_H, CAN_L, TX/RX, and DIFF.
Source channel: CH1 to CH4, D0 to D15
Triggers on the Sync, ID, Data (length settable), Data&ID, Wakeup, Sleep, and
LIN Error of the LIN bus signal (up to 20 Mb/s).
Source channel: CH1 to CH4, D0 to D15
Search&Navigation
Search&Navigation
Copies the search settings from or to the trigger settings mutually, including
Copy
threshold setting and search condition settings
Event navigation: uses the navigation keys to scroll through the event search
Navigation results and navigates to the specified event.
Page 12
Waveform Measurement
Waveform Measurement
Number of
2 pairs of XY cursors
Cursors
Auto
Allows to display cursors during auto measurement
Measurement
Measurement
CH1 to CH4, D0 to D15, Math1 to Math4
Source
Measurement
Range Main, Zoom
(Region)
Page 13
Waveform Calculation
Waveform Calculation
A+B, A-B, A×B, A/B, FFT, A&&B, A||B, A^B, !A, Intg, Diff, Sqrt,
Operation Lg, Ln, Exp, Abs, AX+B, LowPass, HighPass, BandPass, and
BandStop
Waveform Analysis
Waveform Analysis
Page 14
Waveform Analysis
Sampling
Supports all modes, except the Zoom, XY, and ROLL modes
Mode
Sampling
Supports all modes
Mode
Serial Decoding
Serial Decoding
Number of
4 protocol types can be decoded and enabled at the same time
Decodings
Decoding Type Standard: Parallel, RS232/UART, I2C, SPI, CAN, and LIN
Decodes the RS232/UART (up to 20 Mb/s) bus's TX/RX data (5-9 bits), parity
RS232/UART (Odd, Even, or None), and stop bits (1-2 bits)
Decodes the address (with or without the R/W bit) of the I2C bus, data, and
I2C ACK.
Page 15
Serial Decoding
Decodes the MISO/MOSI data (4-32 bits) of the SPI bus. The available mode
SPI includes "Timeout" and "CS".
Decodes the remote frame (ID, byte number, CRC), overload frame, and data
frame (standard/extended ID, control domain, data domain, CRC, and ACK) of
CAN the CAN bus (up to 5 Mb/s). The supported CAN bus signal types include
CAN_H, CAN_L, TX/RX, and DIFF.
Source channel: CH1 to CH4, D0 to D15
Decodes the protocol version (1.X or 2.X) of the LIN bus (up to 20 Mb/s). The
LIN decoding displays sync, ID, data, and check sum.
Source channel: CH1 to CH4, D0 to D15
Bode Plot[7]
Bode Plot
Number of Points
10 to 300
per Octave
Output Amplitude 20 mV to 5 V
Number of
1
Channels
Page 16
AFG (technical specifications are typical values)
Harmonic
-40 dBc
Distortion
Sine
Spurious (non-
-40 dBc
harmonics)
Total Harmonic
<1%
Distortion
S/N Ratio 40 dB
Jitter 500 ps
Ramp Linearity 1%
Symmetry 0 to 100%
2 mV to 10 V (frequency ≤ 10 MHz)
Output Range
2 mV to 5 V (frequency > 10 MHz)
Amplitude
Resolution 100 µV or 3 bits (whichever is greater)
Page 17
AFG (technical specifications are typical values)
Range -5 V to 5 V
Auto
Auto
AutoScale Min voltage > 10 mVpp, duty cycle > 1%, frequency > 35 Hz
Digital Voltmeter
Digital Voltmeter
Page 18
Digital Voltmeter
Limits Beeper Sounds an alarm when the voltage value is within or outside of the limit range
48-bit totalizer
Totalizer
Counts the number of the rising edges
Command Set
Command Set
Display
Display
Page 19
Processor System
Processor System
I/O
I/O
AUX OUT
Trigger Output Outputs a pulse signal when the oscilloscope is triggered
Probe
Compensation 1 kHz, 3 Vpp square waveform
Output
Page 20
Power Supply
Power Supply
Power Supply
Type-C
Interface
Power Voltage DC 15 V, 3 A
Environment
Environment
Operating 0℃ to 50℃
Temperature
Range
Non-operating -30℃ to +60℃
Warranty Three years for the mainframe, excluding the probes and accessories.
Recommended
18 months
Calibration Interval
Page 21
Regulations
Regulations
IEC 61000-4-6:2003/EN
3 V, 0.15-80 MHz
61000-4-6
EN 61010-1:2019
EN 61010-031:2015
IEC 61010-1:2016
IEC 61010-2-030:2017
Safety UL 61010-1:2012 R7
UL 61010-2-31:2017 R2
Page 22
Regulations
Mechanical Characteristics
Mechanical Characteristics
Non-volatile Memory
Non-volatile Memory
Internal Capacity 8 GB
Note:
[1]: Single-channel mode: If any one of the channels is enabled, it is called single-channel mode.
[2]: Dual-channel mode: if any two of the channels are enabled, it is called dual-channel mode.
[3]: Full-channel mode: if any three channels or all of the four channels are enabled, it is called full-channel mode.
[4]: 200 μV/div and 500 μV/div is a magnification of 1 mV/div setting. For vertical accuracy calculations, use full scale of 8 mV.
[5]: For any channel, under the same input impedance with DC-coupled, the Volts/div setting is the same for 100 mV/div and
200 mV/div.
[6]: Channel-to-Channel skew is ±5 ns when the sample rate on the digital channel is 625 MSa/s and the period is 1.6 ns.
[7]: Only DHO914S and DHO924S models are equipped with the Bode plot and AFG function.
[8]: The stop frequency shall be greater than the start frequency.
[9]: Standard configuration.
Page 23
Order Information and Warranty
Period
Order Information
Model
Standard Accessories
Power Adaptor Conforming to the Standard of the Destination ——
Country
Recommended Accessories
NOTE:
For all the mainframes, accessories and options, please contact the local office of RIGOL.
Warranty Period
Three years for the mainframe, excluding the probes and accessories.
Page 24
Option Ordering and Installation
Process
1. According to the usage requirements, please purchase the specified function options from RIGOL
Sales Personnel, and provide the serial number of the instrument that needs to install the option.
2. After receiving the option order, the RIGOL factory will mail the paper software product
3. Log in to RIGOL official website for registration. Use the software key and instruments serial
number provided in the entitlement certificate to obtain the option license code and the option
license file.
4. Install the option by running the SCPI command concerning the option installation. You can also
save the option license file to the root directory of the USB storage device. Then insert it to the
instrument. After being recognized, follow the instructions to install the option.
NOTE:
If any problems occur during the option installation process, please contact RIGOL technical team.