Validation Reference - ACI Pre-Upgrade Validation Script

The document provides a validation reference for a pre-upgrade script for Cisco ACI, detailing the checks and comparisons with other validation tools. It includes compatibility checks for target ACI versions, CIMC versions, and switch hardware, along with fault and configuration checks. The script is available on GitHub and assumes the latest version is being used for accurate validation results.

Uploaded by

suranganath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
384 views67 pages

Validation Reference - ACI Pre-Upgrade Validation Script

The document provides a validation reference for a pre-upgrade script for Cisco ACI, detailing the checks and comparisons with other validation tools. It includes compatibility checks for target ACI versions, CIMC versions, and switch hardware, along with fault and configuration checks. The script is available on GitHub and assumes the latest version is being used for accurate validation results.

Uploaded by

suranganath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 67

11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Validation Reference

Tables in this page list the validations supported by the script and compare them with other
pre-upgrade validation tools for Cisco ACI.

This Script: The python script provided in GitHub

APIC built-in: A validator embedded in the Cisco APIC Upgrade Workflow. This is
automatically performed when performing an upgrade or downgrade for the Cisco APIC or
switches.

Pre-Upgrade Validator (App): A validator that can be installed on the Cisco APICs as an
app that can be downloaded through dcappcenter.cisco.com.

Info

The tables in this page assume the latest version of the script.

If you copied the script to your APIC in the past, make sure that is still the latest version.

Summary List
General Checks

Items This Script APIC built-in Pre-Upgrade


Validator (App)

Compatibility (Target ACI 4.2(4)


Version)

Compatibility (CIMC Version) 4.2(4)

Compatibility (Switch
Hardware)

Compatibility (Switch 4.2(4)


Hardware - gen1)

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 1/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items This Script APIC built-in Pre-Upgrade


Validator (App)

Compatibility (Remote Leaf Except


Switch) CSCvs16767

APIC Target version image 5.2(3e)


and MD5 hash

APIC Cluster is Fully-Fit 4.2(6)

Switches are all in Active state

NTP Status 4.2(5)

Firmware/Maintenance
Groups when crossing 4.0
Release

Features that need to be 5.2(c)


disabled prior to Upgrade Only AppCenter
Apps

Switch Upgrade Group 4.2(4)


Guidelines Only RR spines
(IPN connectivity
not checked)

Intersight Device Connector 4.2(5)


upgrade status

Mini ACI Upgrade to 6.0(2)+

Post Upgrade CallBack


Integrity

6.0(2)+ requires 32 and 64 bit


switch images

Fault Checks

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 2/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items Faults This Script APIC built- Pre-Upgrade


in Validator
(App)

APIC Disk F1527: 80% - 85% 4.2(1)


Space Usage F1528: 85% - 90%
F1529: 90% or
more

Standby APIC 5.2(3)


Disk Space
Usage

Switch Node F1821: 90% or 4.2(4)


/bootflash more
usage

APIC SSD F2730: less than 4.2(1)


Health 10% remaining
F2731: less than
5% remaining
F2732: less than
1% remaining

Switch SSD F3074: reached 4.2(1)


Health 80% lifetime
F3073: reached
90% lifetime

Config On APIC F0467: port- 6.0(1g)


Connected Port configured-for-apic

L3 Port Config F0467: port- 5.2(4d)


configured-as-l2

L2 Port Config F0467: port- 5.2(4d)


configured-as-l3

Access F0467: native-or-


(Untagged) untagged-encap-
Port Config failure

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 3/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items Faults This Script APIC built- Pre-Upgrade


in Validator
(App)

Encap Already F0467: encap-


in Use already-in-use

L3Out Subnets F0467: prefix-entry- 6.0(1g)


already-in-use

BD Subnets F0469: duplicate- 5.2(4d)


subnets-within-ctx

BD Subnets F1425: subnet- 5.2(4d)


overlap

VMM Domain F0130 4.2(1)


Controller
Status

VMM Domain F606391 4.2(1)


LLDP/CDP
Adjacency
Status

Different infra F0454: infra-vlan- 4.2(4)


VLAN via LLDP mismatch

HW F3544: L3Out 5.1(1)


Programming Prefixes
Failure F3545: Contracts

Scalability TCA faults for


(faults related eqptcapacityEntity
to Capacity
Dashboard)

Fabric Port is F1394: ethpm-if-


Down port-down-fabric

Configuration Checks

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 4/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items This Script APIC built- Pre-Upgrade


in Validator (App)

VPC-paired Leaf switches 4.2(4)

Overlapping VLAN Pool

VNID Mismatch

L3Out MTU

BGP Peer Profile at node level


without Loopback

L3Out Route Map import/export


direction

L3Out Route Map Match Rule


with missing-target

L3Out Loopback IP Overlap with


L3Out Interfaces

ISIS Redistribution Metric for


MPod/Msite

BGP Route-target Type for GOLF


over L2EVPN

APIC Container Bridge IP Overlap


with APIC TEP

Per-Leaf Fabric Uplink Scale


Validation

OoB Mgmt Security

EECDH SSL Cipher Disabled

BD and EPG Subnet must have


matching scopes

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 5/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items This Script APIC built- Pre-Upgrade


in Validator (App)

Unsupported FEC Configuration


for N9K-C93180YC-EX

Defect Condition Checks

Items Defect This Script APIC built- Pre-


in Upgrade
Validator
(App)

EP Announce CSCvi76161
Compatibility

Eventmgr DB size CSCvn20175


defect susceptibility

Contract Port 22 CSCvz65560


Defect Check

telemetryStatsServerP CSCvt47850
Object Check

Link Level Flow CSCvo27498


Control Check

Internal VLAN Pool CSCvw33061


Check

APIC CA Cert CSCvy35257


Validation

FabricDomain Name CSCwf80352


Check

Spine SUP HW CSCwb86706


Revision

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 6/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Items Defect This Script APIC built- Pre-


in Upgrade
Validator
(App)

SUP-A/A+ High CSCwh39489


Memory Usage

VMM Uplink Container CSCvr96408


with empty Actives

CoS 3 with Dynamic CSCwf05073


Packet Prioritization

N9K-C93108TC- CSCwh81430
FX3P/FX3H Interface
Down

Invalid FEX CSCwh68103


fabricPathEp DN
References

LLDP Custom CSCwf00416


Interface Description

Route-map CSCwb08081
Community Match

L3out /32 overlap with CSCwb91766


BD Subnet

General Check Details


Compatibility (Target ACI Version)

The APIC Upgrade/Downgrade Support Matrix should be checked for the supported upgrade
paths from your current version.

The script performs the equivalent check by querying objects compatRsUpgRel .

Compatibility (CIMC Version)

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 7/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

The script checks the minimum recommended CIMC version for the given APIC model on the
target version by querying compatRsSuppHw objects.

As the compatRsSuppHw object recommendation is strictly tied to the target software image, it
is possible that the Release Note Documentation for your model/target version has a different
recommendation than what the software recommends. Always check the release note of your
Target version and APIC model to ensure you are getting the latest recommendations.

Note

Older versions of CIMC may required multi-step CIMC upgrades to get to the identified target
version. Refer to the Cisco UCS Rack Server Upgrade Matrix for the latest documentation on
which steps are required and support given your current and target CIMC versions.

Compatibility (Switch Hardware)

The Release Notes of ACI switches should be checked for the target version to make sure your
hardware is supported.

This is mainly for downgrades because all switches operating in one ACI version will be
supported in newer ACI versions, except for generation one switches.

Compatibility (Switch Hardware - gen1)

The script checks the presence of generation one switches when the upgrade is crossing
5.0(1)/15.0(1).

Or you can check the Release Note 15.0(1) of ACI switches to see the list of generation one
switches, typically the one without any suffix such as N9K-C9372PX, that are no longer
supported from 15.0(1) release.

Compatibility (Remote Leaf Switch)

The script checks the requirement to use remote leaf switches on the target version.

It is critical to enable Direct Traffic Forwarding for remote leaf switches prior to upgrading to
Cisco APIC release 5.0(1) as the option becomes mandatory starting from this release.

Direct Traffic Forwarding can be enabled starting from the Cisco APIC release 4.1(2). Note that
additional configuration for TEP IP addresses such as Routable Subnets or External TEP might
be required for this option to be enabled. This means that if you are running a version prior to
4.1(2) and you have a remote leaf switch configured, you cannot directly upgrade to release
5.0. In this case, we recommend that you upgrade to a 4.2 release, enable Direct Traffic
Forwarding, and then upgrade to the desired 5.0 version.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 8/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

See "Upgrade the Remote Leaf Switches and Enable Direct Traffic Forwarding" in the Cisco
APIC Layer 3 Networking Configuration Guide for more information.

A related issue (CSCvs16767) is also addressed in this validation. If you are upgrading to the
release 14.2(2) release while Direct Traffic Forwarding is enabled for the remote leaf switches,
you may hit a defect (CSCvs16767) that could cause remote leaf switches to crash due to the
Multicast FIB Distribution Manager (MFDM) process. This issue happens only when spine
switches are upgraded to release 14.2(2) first while remote leaf switches with Direct Traffic
Forwarding are still on release 14.1(2). Note that Direct Traffic Forwarding was introduced in
release 14.1(2).

To avoid this issue, it is critical that you upgrade to release 14.2(3) or a later release instead of
release 14.2(2) when Direct Traffic Forwarding is enabled.

If you must upgrade to release 14.2(2) for any reason, you must upgrade the remote leaf nodes
first to avoid this issue.

APIC Target version image and MD5 hash

When performing an upgrade in an ACI fabric, there are multiple image transfers that must
occur to prepare all nodes for upgrades. Most of these transfers perform a first level image
validation. However, in the event of a failure, there is value in double-checking the image on
each respective node.

Upgrade Image transfer touchpoints:

1. Transfer the image onto your desktop/file server from cisco.com.

Manually run MD5 against this image. You can validate the expected MD5 of the image
from cisco.com.

2. Upload the image from your desktop or FTP server onto one of the Cisco APICs.

See the Downloading APIC and Switch Images on APICs section in the ACI Upgrade Guide
for instructions on performing this operation on the Cisco APICs:

Upgrading or Downgrading with APIC Releases Prior to 4.x Using the GUI

Upgrading or Downgrading with APIC Releases 4.x or 5.0 Using the GUI

Upgrading or Downgrading with APIC Release 5.1 or Later Using the GUI

The Cisco APIC will automatically perform an image validation and raise a fault F0058 if
the image looks corrupt or incomplete once the transfer has completed.

3. Once the image is added into the firmware repository, the initially uploaded Cisco APIC will
copy that image to the remaining Cisco APICs in the cluster.

You can manually check MD5 on each Cisco APIC's copy of the upgrade image by running
the md5sum command against each Cisco APIC's copy of the image.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 9/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

APIC1# md5sum /firmware/fwrepos/fwrepo/aci-apic-dk9.5.2.1g.bin


f4c79ac1bb3070b4555e507c3d310826 /firmware/fwrepos/fwrepo/aci-apic-
dk9.5.2.1g.bin

4. The switches will eventually each get a copy of the switch .bin image when they are
preparing for upgrade.

You can run MD5 on the individual switch image within /bootflash.

Example

leaf1# md5sum /bootflash/aci-n9000-dk9.15.2.1g.bin


02e3b3fb45a51e36db28e7ff917a0c96 /bootflash/aci-n9000-dk9.15.2.1g.bin

APIC Cluster is Fully-Fit

The script checks whether or not the APIC cluster is in the Fully Fit state.

Or you can check the status in System > Dashboard > Controller to ensure that the cluster
status on all your Cisco Application Policy Infrastructure Controllers (APICs) is in the Fully Fit
state. If one or more of the APICs are in other state, such as Data Layer Partially Diverged, you
must resolve the status of your APIC cluster first.

If your APICs are currently on release 4.2(1) or later, the command acidiag cluster on each
APIC CLI will check the basic items related to APIC clustering for you. If not, follow Initial Fabric
Setup in ACI Troubleshooting Guide 2nd Edition

Switches are all in Active state

The script checks whether or not all ACI switches are in an Active state.

Check Fabric > Inventory > Fabric Membership in the APIC GUI to ensure that all your ACI
switches are in an Active state. If one or more of the ACI switches are in other state, such as
Inactive, Maintenance, etc., you must resolve those issues first.

Inactive: This means that the switch has fabric discovery issues, such as IP reachability from
APICs through the ACI infra network. If your switches are currently on release 14.2(1) or later,
the command show discoveryissues on the switch CLI will check the basic items related to
switch fabric discovery for you.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 10/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Maintenance: This means that the switch is in Maintenance Mode through the GIR (Graceful
Insertion and Removal) operation. This implies that the switch is isolated from the fabric and
does not process most of the APIC communications, including the upgrade-related
communications. You must bring the switch back to the Active state before you can perform
an upgrade. If you want to gracefully upgrade the switch by isolating the switches from the
network first, consider Graceful Upgrade instead. See the Graceful Upgrade or Downgrade of
ACI Switches section in the ACI Upgrade Guide for details.

NTP Status

The script checks all ACI nodes (APICs and switches) are synchronized to NTP.

Ensure that NTP is configured on both the APICs and the ACI switches along with the
necessary IP reachability to the NTP servers through Out-of-band (OOB) or In-band (INB) from
each individual node.

Check the following sections in ACI Troubleshooting Guide 2nd Edition

In-band and out-of-band management

Pod Policies — BGP RR / Date&Time / SNMP

Firmware/Maintenance Groups when crossing 4.0 Release

Beginning with Cisco APIC release 4.0(1), there is only one type of switch update group instead
of the two that were used in previous releases (the firmware groups and maintenance groups).
By consolidating two groups into one, the upgrade configurations are simplified. However,
when upgrading Cisco APICs from a pre-4.0 release to release 4.0(1) or later, you must remove
all firmware group and maintenance group policies prior to the upgrade.

To remove a firmware group policy, navigate to Admin > Firmware > Fabric Node
Firmware > Firmware Groups , then right-click on the name of firmware group and choose
Delete the Firmware Group .

To remove a maintenance group policy, navigate to Admin > Firmware > Fabric Node
Firmware > Maintenance Groups , then right-click on the name of maintenance group and
choose Delete the Maintenance Group .

Once the Cisco APICs are upgraded to 4.0(1) or later, you can create new switch update groups
and perform the switch upgrade from pre-14.0 release to 14.0(1) or later.

This is applicable only when you are upgrading your Cisco APICs from pre-4.0 to 4.0(1) or later.
Once your Cisco APICs are on 4.0(1) or later, you do not have to worry about this for any further
upgrades.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 11/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Note

Internally, Cisco APICs running the 4.0(1) or later release handle the switch update groups with
the same objects as the old maintenance group policies (such as maintMaintP), but with
additional attributes. If you are using an API to configure upgrade policies, you should only use
maintenance group policies starting from Cisco APIC release 4.0(1) or later without manually
creating any firmware group policies, unlike the old pre-4.0 releases.

Features that need to be disabled prior to Upgrade

The following features must be disabled prior to upgrades or downgrades:

App Center apps

Maintenance Mode through Fabric > Inventory > Fabric Membership > Maintenance (GIR)

Config Zone

Rogue Endpoint (only when the running version is 14.1(x) or when upgrading to 14.1(x))

Switch Upgrade Group Guidelines

The script checks if these guidelines from the ACI Upgrade Guide are followed.

Rule 1 – Divide your leaf and spine switches into at least two groups

Rule 2 – Determine how spine switches should be grouped

Rule 3 – Determine how leaf switches should be grouped

Intersight Device Connector upgrade status

If you start an Cisco APIC upgrade while an intersight Device Connector (DC) upgrade is in
progress, the DC upgrade may fail.

You can check the status of intersight DC from System > System Settings > intersight . If
the upgrade of the DC is in progress, wait for a minute and retry the Cisco APIC upgrade. The
upgrade of the Intersight Device Connector typically takes less than a minute.

Mini ACI Upgrade to 6.0(2) or later

Starting with APIC Release 6.0(2), controllers use a new linux operating system which requires
any virtual APIC to be redeployed on the target version.

When upgrading from ACI release 6.0(1) or earlier to release 6.0(2) or later, any virtual APICs
must be removed from the APIC cluster prior to upgrade. You must follow the documented

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 12/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

steps under the Mini ACI Upgrade Guide for this specific upgrade path. A regular policy upgrade
will fail and result in a diverged cluster.

Tip

You can check whether any APICs are virtual by querying topSystem and looking at the
nodeType attribute. unspecified is used for any physical APIC appliance while virtual is
used for any virtual APIC.

# top.System
address : 10.1.0.2
--- omit ---
dn : topology/pod-1/node-2/sys
lastRebootTime : 2024-04-21T11:35:24.844-04:00
lastResetReason : unknown
lcOwn : local
modTs : 2024-04-21T11:56:04.032-04:00
mode : unspecified
monPolDn : uni/fabric/monfab-default
name : vapic2
nameAlias :
nodeType : virtual
--- omit ---

Post Upgrade CallBack Integrity

Post APIC cluster upgrade, APICs may invoke the post-upgrade callback against an existing
object class, which will introduce an object of the new class corresponding to the existing
class to extend/enhance/optimize an existing feature. This is also called data conversion.

Once successfully completed, the number of objects for the existing and newly created classes
should be the same.

If the post-upgrade callback has failed or hasn't been able to fully complete for some reason,
the data conversion will be incomplete.The impact of incomplete data conversion varies
depending on the class that is missing as a result.

The post-upgrade callback may fail due to a software defect, or due to an inappropriate human
intervention during APIC upgrades such as decommissioning an APIC, rebooting an APIC etc.

This validation checks whether the number of objects for the existing and newly created
classes are the same.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 13/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Tip

This validation must be performed after an APIC upgrade but before a switch upgrade.

Regardless of this validation, it is a best practice to run this script twice, before an APIC upgrade
AND before a switch upgrade, especially when the upgrade of the entire fabric cannot be
completed within the same maintenance window. If you have been doing it, please keep doing it.
If not, make sure to do that because this specific validation must be run after an APIC upgrade.
Because of this reason, this validation warns users to run the script again if the current APIC
version and the target version are different when the script is run because it implies the script
was run before an APIC upgrade.

Example

If the old/new class result is infraRsToEncapInstDef / infraAssocEncapInstDef or


infraRsToInterfacePolProfile / infraRsToInterfacePolProfileOpt , the impact of
incomplete post-upgrade callback (i.e. incomplete data conversion) is that VLANs will not be
deployed on leaf switches after the upgrade of the switch.

You can check the number of objects for each of these classes via moquery and the query
option rsp-subtree-include=count :

apic1# moquery -c infraRsToEncapInstDef -x rsp-subtree-include=count


Total Objects shown: 1

# mo.Count
childAction :
count : 11
dn : cnt
lcOwn : local
modTs : never
rn : cnt
status :

apic1# moquery -c infraAssocEncapInstDef -x rsp-subtree-include=count


Total Objects shown: 1

# mo.Count
childAction :
count : 11
dn : cnt
lcOwn : local
modTs : never
rn : cnt
status :

If the Mo count for both old/new classes are the same, it means that new class was created
successfully after the APIC upgrade by the old class's post-upgrade callback.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 14/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

6.0(2)+ requires 32 and 64 bit switch images

When targeting any version that is 6.0(2) or greater, download both the 32-bit and 64-bit Cisco
ACI-mode switch images to the Cisco APIC. Downloading only one of the images may result in
errors during the upgrade process.

For additional information, see the Guidelines and Limitations for Upgrading or Downgrading
section of the Cisco APIC Installation and ACI Upgrade and Downgrade Guide.

Fault Check Details


APIC Disk Space Usage

If a Cisco APIC is running low on disk space for any reason, the Cisco APIC upgrade can fail.
The Cisco APIC will raise three different faults depending on the amount of disk space
remaining. If any of these faults are raised on the system, the issue should be resolved prior to
performing the upgrade.

F1527: A warning level fault for Cisco APIC disk space usage. This is raised when the
utilization is between 80% and 85%.

F1528: A major level fault for Cisco APIC disk space usage. This is raised when the
utilization is between 85% and 90%.

F1529: A critical level fault for Cisco APIC disk space usage. This is raised when the
utilization is between 90% and above.

You can run the following moquery on the CLI of any Cisco APIC to check if these faults exist
on the system. The faults are visible within the GUI as well. In the example below, with the
faults against /firmware , you can simply remove unnecessary firmware images under Admin
> Firmware in the Cisco APIC GUI. You should not perform the Linux command rm to remove
an image directly from /firmware , as the firmware images are synchronized across Cisco
APICs. If the fault is raised against a disk space that you are not aware of, contact Cisco TAC to
resolve the issue prior to the upgrade.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 15/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F1528: Major Fault for APIC disk space usage)

The following shows an example situation where the disk space in /firmware is running low on
APIC 1 (node 1).

admin@apic1:~> moquery -c faultInst -f 'fault.Inst.code=="F1528"'


Total Objects shown: 1

# fault.Inst
code : F1528
ack : no
annotation :
cause : equipment-full
changeSet : available (Old: 5646352, New: 6036744), capUtilized (Old:
86, New: 85), used (Old: 33393968, New: 33003576)
childAction :
created : 2021-05-27T11:58:19.061-04:00
delegated : no
descr : Storage unit /firmware on Node 1 with hostname apic1 mounted
at /firmware is 85% full
dn : topology/pod-1/node-1/sys/ch/p-[/firmware]-f-
[/dev/mapper/vg_ifc0-firmware]/fault-F1528
domain : infra
extMngdBy : undefined
highestSeverity : major
lastTransition : 2021-05-27T12:01:37.128-04:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F1528
rule : eqpt-storage-full-major
severity : major
status :
subject : equipment-full
type : operational
uid :

Note

All three faults look the same except for the utilization percentage and the fault’s severity.

Standby APIC Disk Space Usage

Because a standby Cisco APIC is a cold standby and is not part of the cluster, it is not actively
monitored for fault conditions. As filesystem full checks falls under this category, this means
that any standby Cisco APICs exhibiting these conditions will not flag a fault and instead must
be manually verified.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 16/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

The script performs SSH into each standby Cisco APIC as rescue-user , then run df -h to
verify the filesystem usage. If any filesystem is found to be at 75% or above, the script will alert
users to contact TAC to identify and clear out the condition.

Note

This check is not using faults but positioned in Fault Check just to be viewed with other disk
space usage checks using faults.

Switch Node /bootflash usage

ACI switches mainly have two different faults about the filesystem usage of each partition:

F1820: A minor level fault for switch partition usage. This is raised when the utilization of
the partition exceeds the minor threshold.

F1821: A major level fault for switch partition usage. This is raised when the utilization of
the partition exceeds the major threshold.

Note

The threshold for minor and major depends on partitions. The critical one for upgrades is
/bootflash . The threshold of bootflash is 80% for minor and 90% for major threshold.

On top of this, there is a built-in behavior added to every switch node where it will take action to
ensure that the /bootflash directory maintains 50% capacity. This is specifically to ensure
that switch upgrades are able to successfully transfer and extract the switch image over during
an upgrade.

To do this, there is an internal script that is monitoring /bootflash usage and, if over 50%
usage, it will start removing files to free up the filesystem. Given its aggressiveness, there are
some corner case scenarios where this cleanup script could potentially trigger against the
switch image it is intending to use, which can result in a switch upgrade booting a switch into
the loader prompt given that the boot image was removed from /bootflash .

To prevent this, check the /bootflash prior to an upgrade and take the necessary steps to
understand what is written there and why. Once understood, take the necessary steps to clear
up unnecessary /bootflash files to ensure there is enough space to prevent the auto-cleanup
corner case scenario.

The pre-upgrade validation built into Cisco APIC upgrade workflow monitors the fault F1821,
which can capture the high utilization of any partition. When this fault is present, we
recommend that you resolve it prior to the upgrade even if the fault is not for bootflash.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 17/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

The ACI Pre-Upgrade Validation script (this script) focuses on the utilization of bootflash on
each switch specifically to see if there are any issues with bootflash where the usage is more
than 50%, which might trigger the internal cleanup script.

Example of a query used by this script

The script is calculating the bootflash usage using avail and used in the object
eqptcapacityFSPartition for each switch.

f2-apic1# moquery -c eqptcapacityFSPartition -f


'eqptcapacity.FSPartition.path=="/bootflash"'
Total Objects shown: 6

# eqptcapacity.FSPartition
name : bootflash
avail : 7214920
childAction :
dn : topology/pod-1/node-101/sys/eqptcapacity/fspartition-
bootflash
memAlert : normal
modTs : never
monPolDn : uni/fabric/monfab-default
path : /bootflash
rn : fspartition-bootflash
status :
used : 4320184
--- omit ---

Tip

Alternatively you can log into a leaf switch CLI, and check /bootflash usage df -h

leaf1# df -h
Filesystem Size Used Avail Use% Mounted on
rootfs 2.5G 935M 1.6G 38% /bin
/dev/sda4 12G 5.7G 4.9G 54% /bootflash
/dev/sda2 4.7G 9.6M 4.4G 1% /recovery
/dev/mapper/map-sda9 11G 5.7G 4.2G 58% /isan/lib
none 3.0G 602M 2.5G 20% /dev/shm
none 50M 3.4M 47M 7% /etc
/dev/sda6 56M 1.3M 50M 3% /mnt/cfg/1
/dev/sda5 56M 1.3M 50M 3% /mnt/cfg/0
/dev/sda8 15G 140M 15G 1% /mnt/ifc/log
/dev/sda3 115M 52M 54M 50% /mnt/pss
none 1.5G 2.3M 1.5G 1% /tmp
none 50M 240K 50M 1% /var/log
/dev/sda7 12G 1.4G 9.3G 13% /logflash
none 350M 54M 297M 16% /var/log/dme/log/dme_logs
none 512M 24M 489M 5% /var/sysmgr/mem_logs
none 40M 4.0K 40M 1% /var/sysmgr/startup-cfg
none 500M 0 500M 0% /volatile

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 18/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Note

If you suspect that the auto cleanup removed some files within /bootflash , you can review a
log to validate this:

leaf1# egrep "higher|removed" /mnt/pss/core_control.log


[2020-07-22 16:52:08.928318] Bootflash Usage is higher than 50%!!
[2020-07-22 16:52:08.931990] File: MemoryLog.65%_usage removed !!
[2020-07-22 16:52:08.943914] File: mem_log.txt.old.gz removed !!
[2020-07-22 16:52:08.955376] File: libmon.logs removed !!
[2020-07-22 16:52:08.966686] File: urib_api_log.txt removed !!
[2020-07-22 16:52:08.977832] File: disk_log.txt removed !!
[2020-07-22 16:52:08.989102] File: mem_log.txt removed !!
[2020-07-22 16:52:09.414572] File: aci-n9000-dk9.13.2.1m.bin removed !!

APIC SSD Health

Starting from Cisco APIC release 2.3(1), faults occur when the SSD media wearout indicator
(life remaining) is less than a certain percentage on Cisco APIC nodes. An SSD with little
lifetime may cause any operations that require updates for the internal database, such as
upgrade or downgrade operations, to fail. The Cisco APIC will raise three different faults,
depending on the amount of SSD life remaining. If the most critical fault (F2732) is raised on
the system, you must replace the SSD by contacting Cisco TAC prior to performing the
upgrade.

F2730: A warning level fault for Cisco APIC SSD life remaining. This is raised when the life
remaining is less than 10%.

F2731: A major level fault for Cisco APIC SSD life remaining. This is raised when the life
remaining is less than 5%.

F2732: A critical level fault for Cisco APIC SSD life remaining. This is raised when the life
remaining is less than 1%.

Also, in very rare occasions, the SSD might have other operational issues than its lifetime. In
such a case, look for the fault F0101.

However, if your Cisco APICs are still running on a release older than the 4.2(7f) or 5.2(1g),
these fault may not report a correct value due to CSCvx28453. In such a case, look for SSD
Wearout Indicator is XX in /var/log/dme/log/svc_ifc_ae.bin.log on your APICs, where
XX is a number.

See the APIC SSD Replacement technote for more details.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 19/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F2731: Major Fault for APIC SSD life remaining)

The following shows an example of APIC 3 (node 3) with an SSD life remaining of 1% (the major
fault F2731). In this case, although the critical fault F2732 for the life remaining less than 1% is
not raised, it is close enough to F2732’s threshold and it is recommended to replace the SSD.

APIC1# moquery -c faultInfo -f 'fault.Inst.code=="F2731"'


Total Objects shown: 1

# fault.Inst
code : F2731
ack : no
annotation :
cause : equipment-wearout
changeSet : mediaWearout (Old: 2, New: 1)
childAction :
created : 2019-10-22T11:47:40.791+01:00
delegated : no
descr : Storage unit /dev/sdb on Node 3 mounted at /dev/sdb has 1%
life remaining
dn : topology/pod-2/node-3/sys/ch/p-[/dev/sdb]-f-
[/dev/sdb]/fault-F2731
domain : infra
extMngdBy : undefined
highestSeverity : major
lastTransition : 2019-10-22T11:49:48.788+01:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F2731
rule : eqpt-storage-wearout-major
severity : major
status :
subject : equipment-wearout
type : operational
uid :

Switch SSD Health

Starting from release 2.1(4), 2.2(4), 2.3(1o), and 3.1(2m), faults occur if the flash SSD lifetime
usage has reached a certain endurance limit on the leaf or spine switches. A flash SSD with
little lifetime may cause any operations that require updates for the internal database, such as
Cisco APIC communication, to fail, or the switch may fail to boot up. The ACI switch will raise
two different faults depending on the amount of SSD life it’s consumed. If the most critical fault
(F3073) is raised on the system, you must replace the SSD by contacting Cisco TAC prior to
performing the upgrade.

F3074: A warning level fault for switch SSD lifetime. This is raised when the lifetime
reached 80% of its limit.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 20/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

F3073: A major level fault for switch SSD lifetime. This is raised when the lifetime reached
90% of its limit.

You can run the moquery below on the CLI of any Cisco APIC to check if these faults exist on
the system. The faults are visible within the GUI as well.

If your Cisco APICs are still running an older release, contact Cisco TAC to check the SSD life
status.

See the ACI Switch Node SSD Lifetime Explained technote for more details.

Fault Example (F3074: Warning Fault for switch SSD lifetime)

The following shows an example of node 101 that has reached 85% of its SSD lifetime.

APIC1# moquery -c faultInst -f 'fault.Inst.code=="F3074"'

Total Objects shown: 4

# fault.Inst
code : F3074
ack : no
annotation :
cause : equipment-flash-warning
changeSet : acc:read-write, cap:61057, deltape:23, descr:flash, gbb:0,
id:1, lba:0, lifetime:85, majorAlarm:no, mfgTm:2020-09-22T02:21:45.675+00:00,
minorAlarm:yes, model:Micron_M600_MTFDDAT064MBF, operSt:ok, peCycles:4290,
readErr:0, rev:MC04, ser:MSA20400892, tbw:21.279228, type:flash, vendor:Micron,
warning:yes, wlc:0
childAction :
created : 2020-09-21T21:21:45.721-05:00
delegated : no
descr : SSD has reached 80% lifetime and is nearing its endurance
limit. Please plan for Switch/Supervisor replacement soon
dn : topology/pod-1/node-101/sys/ch/supslot-1/sup/flash/fault-
F3074
domain : infra
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2020-09-21T21:24:03.132-05:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F3074
rule : eqpt-flash-flash-minor-alarm
severity : minor
status :
subject : flash-minor-alarm
type : operational
--- omit ---

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 21/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Config On APIC Connected Port

In a healthy ACI deployment, there should be no EPG or policy deployment pushed to any
interfaces where a Cisco APIC is connected. When a Cisco APIC is connected to a leaf switch,
LLDP validation occurs between the Cisco APIC and the leaf switch to allow it into the fabric
without any configuration by the user. When a policy is pushed to a leaf switch interface that is
connected to a Cisco APIC, that configuration will be denied and a fault will be raised. However,
if the link to the Cisco APIC flaps for any reason, primarily during an upgrade when the Cisco
APIC reboots, the policy can then be deployed to that leaf switch interface. This results in the
Cisco APIC being blocked from re-joining the fabric after it has reloaded.

It is critical that you resolve these issues before the upgrade to prevent any issues. You can run
the moquery below on the CLI of any Cisco APIC to check if these faults exist on the system.
The faults are visible within the GUI as well.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 22/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0467: port-configured-for-apic)

The following fault shows an example of node 101 eth1/1 that is connected to a Cisco APIC that
has some EPG configurations on it.

admin@apic1:~> moquery -c faultInst -x 'query-target-


filter=wcard(faultInst.descr,"port-configured-for-apic")'
Total Objects shown: 1

# fault.Inst
code : F0467
ack : no
annotation :
cause : configuration-failed
changeSet : configQual:port-configured-for-apic, configSt:failed-to-
apply, debugMessage:port-configured-for-apic: Port is connected to the APIC;,
temporaryError:no
childAction :
created : 2021-06-03T07:51:42.263-04:00
delegated : yes
descr : Configuration failed for uni/tn-jr/ap-ap1/epg-epg1 node 101
eth1/1 due to Port Connected to Controller, debug message: port-configured-for-
apic: Port is connected to the APIC;
dn : topology/pod-1/node-101/local/svc-policyelem-id-
0/uni/epp/fv-[uni/tn-jr/ap-ap1/epg-epg1]/node-101/stpathatt-
[eth1/1]/nwissues/fault-F0467
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2021-06-03T07:53:52.021-04:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
type : config
uid :

L2/L3 Port Config

This is another type of the F0467 fault code family that you should check before an upgrade.
This fault alerts that an interface configured under a Layer3 Out (L3Out) has failed because the
port that the policy is deployed for is operating in the opposite mode. For example, you might
have configured a routed sub-interface under an L3Out, making the port an L3 port. However,
there is already L2 policy on that port. A port in ACI can either be L2 or L3, but not both, just like
a port on any layer 3 switches that can be either switchport (L2) or no switchport (L3), so this
policy fails in this situation. The same rule applies if a port is already an L3 port, but you deploy

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 23/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

L2 config onto it. After an upgrade, it’s possible that the previously working configuration will
break if this faulty policy is deployed first after the switch reloads.

It is critical that you resolve these issues before the upgrade to prevent any issues. The
interface that the fault is raised on should either be corrected or deleted in order to clear the
fault. You can run the moquery below on the CLI of any Cisco APIC to check if these faults exist
on the system. The faults are visible within the GUI as well.

Fault Example (F0467: port-configured-as-l2)

The following fault shows an example of the configuration from L3Out OSPF under tenant jr
has failed on node 101 eth1/7 because the same port is already configured as L2 by other
components, such as EPGs or other L3Outs using the same port as SVI. It implies that, in this
case, L3Out OSPF is trying to use node 101 eth1/7 as a routed port or routed sub-interface (L3)
as opposed to SVI (L2).

admin@apic1:~> moquery -c faultDelegate -x 'query-target-


filter=wcard(faultInst.changeSet,"port-configured-as-l2")'
Total Objects shown: 1

# fault.Delegate
affected : resPolCont/rtdOutCont/rtdOutDef-[uni/tn-jr/out-OSPF]/node-
101/stpathatt-[eth1/7]/nwissues
code : F0467
ack : no
cause : configuration-failed
changeSet : configQual:port-configured-as-l2, configSt:failed-to-apply,
temporaryError:no
childAction :
created : 2021-06-23T12:17:54.775-04:00
descr : Fault delegate: Configuration failed for uni/tn-jr/out-OSPF
node 101 eth1/7 due to Interface Configured as L2, debug message:
dn : uni/tn-jr/out-OSPF/fd-[resPolCont/rtdOutCont/rtdOutDef-
[uni/tn-jr/out-OSPF]/node-101/stpathatt-[eth1/7]/nwissues]-fault-F0467
domain : tenant
highestSeverity : minor
lastTransition :2021-06-23T12:20:09.780-04:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fd-[resPolCont/rtdOutCont/rtdOutDef-[uni/tn-jr/out-
OSPF]/node-101/stpathatt-[eth1/7]/nwissues]-fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
type : config

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 24/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0467: port-configured-as-l3)

The following fault shows an example of the opposite of above situation. In this example, L3Out
IPV6 tries to use node 101 eth1/7 as an L2 port and it failed because other L3Outs are already
using the same port as an L3 port.

admin@apic1:~> moquery -c faultDelegate -x 'query-target-


filter=wcard(faultInst.changeSet,"port-configured-as-l3")'
Total Objects shown: 1

# fault.Delegate
affected : resPolCont/rtdOutCont/rtdOutDef-[uni/tn-jr/out-IPV6]/node-
101/stpathatt-[eth1/7]/nwissues
code : F0467
ack : no
cause : configuration-failed
changeSet : configQual:port-configured-as-l3, configSt:failed-to-apply,
debugMessage:port-configured-as-l3: Port has one or more layer3 sub-
interfaces;, temporaryError:no
childAction :
created : 2021-06-23T12:31:41.949-04:00
descr : Fault delegate: Configuration failed for uni/tn-jr/out-IPV6
node 101 eth1/7 due to Interface Configured as L3, debug message: port-
configured-as-l3: Port has one or more layer3 sub-interfaces;
dn : uni/tn-jr/out-IPV6/fd-[resPolCont/rtdOutCont/rtdOutDef-
[uni/tn-jr/out-IPV6]/node-101/stpathatt-[eth1/7]/nwissues]-fault-F0467
domain : tenant
highestSeverity : minor
lastTransition : 2021-06-23T12:31:41.949-04:00
lc : soaking
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fd-[resPolCont/rtdOutCont/rtdOutDef-[uni/tn-jr/out-
IPV6]/node-101/stpathatt-[eth1/7]/nwissues]-fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
type : config

Access (Untagged) Port Config

The APIC GUI or REST previously accepted two different access encapsulations on the same
port, despite raising a fault with code F0467 and "native-or-untagged-encap-failure" in the
changeSet. This configuration, likely resulting from user error, presents a significant risk of
outage during switch upgrades or stateless reloads.

The script verifies these faults to ensure that a port is not configured as part of two access
VLANs. You need to resolve the conflict causing this fault before any upgrades to prevent

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 25/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

potential outages. Failure to do so may result in the deployment of a new VLAN/EPG on the
port after the upgrade, leading to downtime in the environment.

Fault Example (F0467: native-or-untagged-encap-failure)

apic1# moquery -c faultInst -x 'query-target-


filter=wcard(faultInst.changeSet,"native-or-untagged-encap-failure")'
Total Objects shown: 1

# fault.Inst
code : F0467
ack : no
alert : no
annotation :
cause : configuration-failed
changeSet : configQual:native-or-untagged-encap-failure,
configSt:failed-to-apply, temporaryError:no
childAction :
created : 2024-04-20T10:03:48.493+02:00
delegated : yes
descr : Configuration failed for uni/tn-EEA-1/ap-APP1/epg-EPG-2 node
101 eth1/28 due to Only One Native or Untagged Encap Allowed on Interface,
debug message:
dn : topology/pod-1/node-101/local/svc-policyelem-id-
0/uni/epp/fv-[uni/tn-EEA-1/ap-APP1/epg-EPG-2]/node-101/stpathatt-
[eth1/28]/nwissues/fault-F0467
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2024-04-20T10:03:53.045+02:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
title :
type : config
uid :
userdom : all
apic1#

Please note that this behavior has recently changed. With the new behavior, rejected through
policy distributor validation, two different access encapsulations are no longer allowed on the
same port by the APIC. This change has been documented in CSCwj69435.

Encap Already in Use

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 26/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

This is another type of the F0467 fault code family that you should check before an upgrade.
This fault alerts that an interface configuration under an EPG or an SVI configuration for an
L3Out has failed because the VLAN encapsulation for the interface is already used by another
interface on the same switch for a different purpose. After an upgrade, it’s possible that the
previous working configuration will break if this faulty policy is deployed first after the switch
reloads.

It is critical that you resolve these issues before the upgrade to prevent any unexpected
outages when the switch(es) upgrade. The VLAN encapsulation on the interface that the fault
is raised on should either be corrected or deleted in order to clear the fault. You can run the
moquery in the example below on the CLI of any Cisco APIC to check if these faults exist on
the system. The faults are visible within the GUI as well.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 27/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0467: encap-already-in-use)

The following shows three examples.

The first fault is for the interface configuration under the EPG EPG1-2 in application profile AP1
in tenant TK on node 101 interface eth1/4 with VLAN 2011 . The fault description indicates
that VLAN 2011 is already used by EPG EPG1-1 in application profile AP1 in tenant TK .

The second fault is for the SVI configuration under L3Out BGP in tenant TK on node-103
interface eth1/11 with VLAN 2013 . The fault description indicates that VLAN 2013 is already
used by EPG1-3 in application profile AP1 in tenant TK .

The third fault is for the interface configuration under the EPG EPG3-1 in application profile AP1
in tenant TK on node 103 interface eth1/1 with VLAN 2051 . The fault description indicates
that VLAN 2051 is already used by L3Out BGP in tenant TK .

Note that the fault description may not include (vlan-2011) in Encap (vlan-2011) on older
versions.

admin@apic1:~> moquery -c faultInst -x 'query-target-


filter=wcard(faultInst.descr,"encap-already-in-use")'
Total Objects shown: 3

# fault.Inst
code : F0467
ack : no
alert : no
annotation :
cause : configuration-failed
changeSet : configQual:encap-already-in-use, configSt:failed-to-apply,
debugMessage:encap-already-in-use: Encap (vlan-2011) is already in use by
TK:AP1:EPG1-1;, temporaryError:no
childAction :
created : 2024-04-19T21:02:20.878-07:00
delegated : yes
descr : Configuration failed for uni/tn-TK/ap-AP1/epg-EPG1-2 node
101 eth1/4 due to Encap Already Used in Another EPG, debug message: encap-
already-in-use: Encap (vlan-2011) is already in use by TK:AP1:EPG1-1;
dn : topology/pod-1/node-101/local/svc-policyelem-id-
0/uni/epp/fv-[uni/tn-TK/ap-AP1/epg-EPG1-2]/node-101/stpathatt-
[eth1/4]/nwissues/fault-F0467
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2024-04-19T21:04:25.300-07:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
title :

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 28/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

type : config
uid :
userdom : all

# fault.Inst
code : F0467
ack : no
alert : no
annotation :
cause : configuration-failed
changeSet : configQual:encap-already-in-use, configSt:failed-to-apply,
debugMessage:encap-already-in-use: Encap (vlan-2013) is already in use by
TK:AP1:EPG1-3;, temporaryError:no
childAction :
created : 2024-04-19T21:59:31.948-07:00
delegated : yes
descr : Configuration failed for uni/tn-TK/out-BGP node 103 eth1/1
due to Encap Already Used in Another EPG, debug message: encap-already-in-use
Encap (vlan-2013) is already in use by TK:AP1:EPG1-3;
dn : topology/pod-2/node-103/local/svc-policyelem-id-
0/resPolCont/rtdOutCont/rtdOutDef-[uni/tn-TK/out-BGP]/node-103/stpathatt-
[eth1/11]/nwissues/fault-F0467
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2024-04-19T21:59:31.948-07:00
lc : soaking
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
title :
type : config
uid :
userdom : all

# fault.Inst
code : F0467
ack : no
alert : no
annotation :
cause : configuration-failed
changeSet : configQual:encap-already-in-use, configSt:failed-to-apply,
debugMessage:encap-already-in-use: Encap (vlan-2051) is already in use by
TK:VRFA:l3out-BGP:vlan-2051;, temporaryError:no
childAction :
created : 2024-04-19T21:58:02.758-07:00
delegated : yes
descr : Configuration failed for uni/tn-TK/ap-AP1/epg-EPG3-1 node
103 eth1/1 due to Encap Already Used in Another EPG, debug message: encap-
already-in-use: Encap (vlan-2051) is already in use by TK:VRFA:l3out-BGP:vlan
2051;
dn : topology/pod-2/node-103/local/svc-policyelem-id-
0/uni/epp/fv-[uni/tn-TK/ap-AP1/epg-EPG3-1]/node-103/stpathatt-
[eth1/1]/nwissues/fault-F0467
domain : tenant

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 29/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

extMngdBy : undefined
highestSeverity : minor
lastTransition : 2024-04-19T21:58:02.758-07:00
lc : soaking
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
title :
type : config
uid :
userdom : all

L3Out Subnets

There is another type of the F0467 fault code family that you should check before an upgrade.
This fault alerts that an external EPG defined under a Layer3 Out (L3Out) has a subnet with the
External Subnet for the External EPG scope configured that overlaps with another L3Out
external EPG in the same VRF. After an upgrade, it’s possible that the previous working
configuration will break if this faulty policy is deployed first after the switch reloads.

It is critical that you resolve these issues before the upgrade to prevent any unexpected
outages when the switch(es) upgrade. The subnet that the fault is raised on should either be
corrected or deleted in order to clear the fault. You can run the moquery below on the CLI of
any Cisco APIC to check if these faults exist on the system. The faults are visible within the GUI
as well.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 30/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0467: prefix-entry-already-in-use)

The following shows an example of L3Out OSPF with an external EPG called all . In this
external EPG, an L3Out subnet 112.112.112.112/32 is configured with External Subnet for the
External EPG in the attempt to classify the source or destination IP address of packets to this
external EPG for contracts application. However, it failed because the same subnet is already in
use by another external EPG in the same VRF.

admin@apic1:~> moquery -c faultInst -x'query-target-


filter=wcard(faultInst.descr,"prefix-entry-already-in-use")'
Total Objects shown: 1

# fault.Inst
code : F0467
ack : no
annotation :
cause : configuration-failed
changeSet : configQual:prefix-entry-already-in-use, configSt:failed-to-
apply, debugMessage:prefix-entry-already-in-use: Prefix entry sys/ctx-[vxlan-
2621440]/pfx-[112.112.112.112/32] is in use;, temporaryError:no
childAction :
created : 2021-06-22T09:02:36.630-04:00
delegated : yes
descr : Configuration failed for uni/tn-jr/out-OSPF/instP-all due to
Prefix Entry Already Used in Another EPG, debug message: prefix-entry-already-
in-use: Prefix entry sys/ctx-[vxlan-2621440]/pfx-[112.112.112.112/32] is in
use;
dn : topology/pod-1/node-101/local/svc-policyelem-id-
0/uni/epp/rtd-[uni/tn-jr/out-OSPF/instP-all]/nwissues/fault-F0467
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2021-06-22T09:04:51.985-04:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0467
rule : fv-nw-issues-config-failed
severity : minor
status :
subject : management
type : config
uid :

BD Subnets

If at any point in time an overlapping IP address or subnet is deployed within a VRF, that policy
will fail and a fault will be raised at the node level. However, on upgrade, it’s possible that this
previously failing configuration will get pushed to the leaf switch before the previously working

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 31/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

configuration. This results in a situation where the known working state before the upgrade is
broken after the upgrade and can cause connectivity issues for the previously working subnet.

There are two faults for this situation:

F0469 (duplicate-subnets-within-ctx) is raised when multiple BD subnets are configured


with the exact same subnet in the same VRF

F1425 (subnet-overlap) is raised when BD subnets are not the same but overlapping

It is critical that you resolve these issues before the upgrade to prevent any issues. The subnet
that the fault is raised on should either be corrected or deleted in order to clear the fault. You
can run the moquery below on the CLI of any Cisco APIC to check if these faults exist on the
system. The faults are visible within the GUI as well.

Fault Example (F0469: duplicate-subnets-within-ctx)

admin@f1-apic1:~> moquery -c faultInst -f 'fault.Inst.code=="F0469"'


Total Objects shown: 4

# fault.Inst
code : F0469
ack : no
annotation :
cause : configuration-failed
changeSet : configQual (New: duplicate-subnets-within-ctx), configSt
(New: failed-to-apply), debugMessage (New: uni/tn-TK/BD-BD2,uni/tn-TK/BD-BD1)
childAction :
created : 2021-07-08T17:40:37.630-07:00
delegated : yes
descr : BD Configuration failed for uni/tn-TK/BD-BD2 due to
duplicate-subnets-within-ctx: uni/tn-TK/BD-BD2 ,uni/tn-TK/BD-BD1
dn : topology/pod-1/node-101/local/svc-policyelem-id-0/uni/bd-
[uni/tn-TK/BD-BD2]-isSvc-no/bdcfgissues/fault-F0469
domain : tenant
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2021-07-08T17:40:37.630-07:00
lc : soaking
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F0469
rule : fv-bdconfig-issues-config-failed
severity : minor
status :
subject : management
type : config
uid :
--- omit ---

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 32/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F1425: subnet-overlap)

admin@apic1:~> moquery -c faultInst -f 'fault.Inst.code=="F1425"'


Total Objects shown: 1

# fault.Inst
code : F1425
ack : no
annotation :
cause : ip-provisioning-failed
changeSet : ipv4CfgFailedBmp (New:
ipv4:Addraddr_failed_flag,ipv4:Addrctrl_failed_flag,ipv4:AddrlcOwn_failed_flag,
ipv4:AddrmodTs_failed_flag,ipv4:AddrmonPolDn_failed_flag,ipv4:Addrpref_failed_flag
ipv4:Addrtype_failed_flag,ipv4:AddrvpcPeer_failed_flag), ipv4CfgState (New: 1), op
overlap)
childAction :
created : 2020-02-27T01:50:45.656+01:00
delegated : no
descr : IPv4 address(10.10.10.1/24) is operationally down, reason:Subne
fabric hostname leaf-101
dn : topology/pod-1/node-101/sys/ipv4/inst/dom-jr:v1/if-[vlan10]/add
F1425
domain : access
extMngdBy : undefined
highestSeverity : major
lastTransition : 2020-02-27T01:52:49.812+01:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F1425
rule : ipv4-addr-oper-st-down
severity : major
status :
subject : oper-state-err
type : operational
uid :

VMM Domain Controller Status

If there is an issue in communication between the Cisco APIC and the VMM controller, the
VMM controller status is marked as offline and the fault F0130 is raised. Ensure that the
connectivity between them is restored prior to upgrades so that any resources that are
currently deployed on switches based on the communication with the VMM controller will not
be changed or lost due to the Cisco APICs not being able to retrieve necessary information
after an upgrade.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 33/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0130: VMM Controller connection failure)

The following is an example of the Cisco APIC failing to communicate with the VMM controller
MyVMMControler with the IP 192.168.100.100 in VMM domain LAB_VMM .

apic1# moquery -c faultInst -f 'fault.Inst.code=="F0130"'


Total Objects shown: 1

# fault.Inst
code : F0130
ack : no
cause : connect-failed
changeSet : operSt (Old: unknown, New: offline)
childAction :
created : 2016-05-23T16:07:50.205-05:00
delegated : yes
descr : Connection to VMM controller: 192.168.100.100 with name
MyVMMController in datacenter LAB1 in domain: LAB_VMM is failing repeatedly
with error: [Failed to retrieve ServiceContent from the vCenter server
192.168.100.100]. Please verify network connectivity of VMM controller
192.168.100.100 and check VMM controller user credentials are valid.
dn : comp/prov-VMware/ctrlr-[LAB_VMM]-MyVMMController/fault-F0130
domain : external
highestSeverity : major
lastTransition : 2016-05-23T16:10:04.219-05:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F0130
rule : comp-ctrlr-connect-failed
severity : major
status :
subject : controller
type : communications
uid :

VMM Domain LLDP/CDP Adjacency Status

With On Demand or Immediate resolution immediacy as opposed to pre-provision in the VMM


domain when attaching it to an EPG, for some VMM integrations such as VMware DVS
integration, the Cisco APIC checks LLDP or CDP information from leaf switches connected to
the hypervisors and also from the VMM controller managing the hypervisors. This information
is required from both leaf switches and hypervisors to dynamically detect the leaf interface
connecting to the hypervisor, even when there is an intermediate switch in between such as
Cisco UCS Fabric Interconnect. Once the interface is detected, the Cisco APIC dynamically
deploys VLANs only on the necessary interface(s) of the leaf switch that the hypervisor is
connected to.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 34/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Prior to Cisco APIC release 3.0(1), VLANs used to be removed from the leaf interfaces if the
Cisco APIC loses the connectivity to the VMM controller because the Cisco APIC can no longer
compare the LLDP or CDP information from the hypervisor’s point of view. Starting from Cisco
APIC release 3.0(1), VLANs will not be removed from the leaf interfaces even if the Cisco APIC
loses the connectivity to the VMM controller to prevent transient management plane issues
from impacting the data plane traffic. However, it may cause some churns in the Cisco APIC
process by repeatedly trying to obtain the LLDP/CDP information. When the LLDP/CDP
information is missing, the fault F606391 is raised.

Due to these reasons, regardless of the Cisco APIC release, it is important to resolve this fault
prior to the upgrade. If the faults are raised on a VMM domain configured for the Cisco
Application Virtual Edge (AVE), LLDP and CDP can be disabled entirely because the control
plane built to program the switches is based on the opflex protocol and not LLDP/CDP. When
LLDP and CDP are disabled, the faults should clear. The configuration to change the LLDP/CDP
state for a VMM domain is configured under the vSwitch Policy for the VMM Domain.

Fault Example (F606391: LLDP/CDP adjacency missing for hypervisors)

apic1# moquery -c faultInst -f 'fault.Inst.code=="F606391"'


Total Objects shown: 5

# fault.Inst
code : F606391
ack : no
annotation :
cause : fsm-failed
changeSet :
childAction :
created : 2019-07-18T01:17:39.435+08:00
delegated : yes
descr : [FSM:FAILED]: Get LLDP/CDP adjacency information
for the physical adapters on the host:
hypervisor1.cisco.com(TASK:ifc:vmmmgr:CompHvGetHpNicAdj)
dn : comp/prov-VMware/ctrlr-[LAB_VMM]-
MyVMMController/hv-host-29039/fault-F606391
domain : infra
extMngdBy : undefined
highestSeverity : major
lastTransition : 2019-07-18T01:17:39.435+08:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F606391
rule : fsm-get-hp-nic-adj-fsm-fail
severity : major
status :
subject : task-ifc-vmmmgr-comp-hv-get-hp-nic-adj
type : config
uid :

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 35/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Different infra VLAN via LLDP

If you have interfaces connected back-to-back between two different ACI fabrics, you must
disable LLDP on those interfaces prior to upgrades. This is because when the switch comes
back up after the upgrade, it may receive and process LLDP packets from the other fabric that
may be using a different infra VLAN. If that happens, the switch incorrectly tries to be
discovered through the infra VLAN of the other fabric and will not be discoverable in the correct
fabric.

There is a fault to detect if an ACI switch is currently is receiving an LLDP packet with infra
VLAN mismatch from other fabrics.

Fault Example (F0454: LLDP with mismatched parameters)

apic1# moquery -c faultInst -f 'fault.Inst.code=="F0454"'


Total Objects shown: 2

# fault.Inst
code : F0454
ack : no
alert : no
annotation :
cause : wiring-check-failed
changeSet : wiringIssues (New: ctrlr-uuid-mismatch,fabric-domain-
mismatch,infra-ip-mismatch,infra-vlan-mismatch)
childAction :
created : 2021-06-30T10:44:25.576-07:00
delegated : no
descr : Port eth1/48 is out of service due to Controller UUID
mismatch,Fabric domain name mismatch,Infra subnet mismatch,Infra vlan mismatch
dn : topology/pod-1/node-104/sys/lldp/inst/if-[eth1/48]/fault-
F0454
--- omit ---

HW Programming Failure

The fault F3544 occurs when the switch fails to activate an entry to map a prefix to pcTag due
to either a hardware or software programming failure. These entries are configured for L3Out
subnets with the External Subnets for the External EPG scope under an external EPG in an
L3Out, and used to map L3Out subnets to L3Out EPGs. If you see this because of the LPM or
host routes capacity on the switch, such a switch may activate different sets of entries after a
reboot or upgrade. This may lead to services that used to work before an upgrade begins to fail
after an upgrade. When this fault is present, check the Operations > Capacity Dashboard >
Leaf Capacity in the Cisco APIC GUI for LPM and /32 or /128 routes usage.

The fault F3545 occurs when the switch fails to activate a contract rule (zoning-rule) due to
either a hardware or software programming failure. If you see this, it's because the policy CAM

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 36/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

is full and no more contracts can be deployed on the switch, and a different sets of contracts
may deploy after a reboot or upgrade. This may lead to services that used to work before an
upgrade begins to fail after an upgrade. Note that the same fault could occur for other reasons,
such as an unsupported type of filter in the contract(s) instead of policy CAM usage. For
instance, first generation ACI switches support EtherType IP but not IPv4 or IPv6 in contract
filters. When this fault is present, check the Operations > Capacity Dashboard > Leaf
Capacity in the Cisco APIC GUI for policy CAM usage.

Fault Example (F3544: L3Out Subnet Programming Failure)

The following shows an example of node 101 with programming failure for 80 L3Out subnets
with External Subnets for the External EPG ( pfxRuleFailed ). Although it also shows the
programming failure of contracts themselves ( zoneRuleFailed ) in the changeSet , a separate
fault F3545 is raised for that.

apic1# moquery -c faultInst -f 'fault.Inst.code=="F3544"'


Total Objects shown: 1

# fault.Inst
code : F3544
ack : no
annotation :
cause : actrl-resource-unavailable
changeSet : pfxRuleFailed (New: 80), zoneRuleFailed (New: 266)
childAction :
created : 2020-02-26T01:01:49.246-05:00
delegated : no
descr : 80 number of Prefix failed on leaf1
dn : topology/pod-1/node-101/sys/actrl/dbgStatsReport/fault-F3544
domain : infra
extMngdBy : undefined
highestSeverity : major
lastTransition : 2020-02-26T01:03:59.849-05:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F3544
rule : actrl-stats-report-pre-fix-prog-failed
severity : major
status :
subject : hwprog-failed
type : operational
uid :

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 37/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F3545: Zoning Rule Programming Failure)

The following shows an example of node 101 with programming failure for 266 contract rules
( zoneRuleFailed ). Although it also shows the programming failure of L3Out subnets
( pfxRuleFailed ) in the changeSet , a separate fault F3544 is raised for that.

apic1# moquery -c faultInst -f 'fault.Inst.code=="F3545"'


Total Objects shown: 1

# fault.Inst
code : F3545
ack : no
annotation :
cause : actrl-resource-unavailable
changeSet : pfxRuleFailed (New: 80), zoneRuleFailed (New: 266)
childAction :
created : 2020-02-26T01:01:49.256-05:00
delegated : no
descr : 266 number of Rules failed on leaf1
dn : topology/pod-1/node-101/sys/actrl/dbgStatsReport/fault-F3545
domain : infra
extMngdBy : undefined
highestSeverity : major
lastTransition : 2020-02-26T01:03:59.849-05:00
lc : raised
modTs : never
occur : 1
origSeverity : major
prevSeverity : major
rn : fault-F3545
rule : actrl-stats-report-zone-rule-prog-failed
severity : major
status :
subject : hwprog-failed
type : operational
uid :

Scalability (faults related to Capacity Dashboard)

The script checks faults raised under eqptcapacityEntity , which are TCA (Threshold Crossed
Alert) faults for various objects monitored in the Capacity Dashboard from Operations >
Capacity Dashboard > Leaf Capacity on the Cisco APIC GUI.

It is important to ensure that any capacity does not exceed its limit. When it's exceeding the
limit, it may cause inconsistency on resources that are deployed before and after an upgrade
just like it was warned for Policy CAM Programming for Contracts (F3545) and L3Out Subnets
Programming for Contracts (F3544).

Examples of what's monitored via Operations > Capacity Dashboard > Leaf Capacity are
the number of endpoints such as MAC (Learned), IPv4 (Learned), Policy CAM, LPM, host
routes, VLANs and so on.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 38/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F193568: TCA VLAN Usage)

apic1# moquery -c eqptcapacityEntity -x 'rsp-subtree-include=faults,no-scoped'


Total Objects shown: 1

# fault.Inst
code : F193568
ack : no
annotation :
cause : threshold-crossed
changeSet : totalCum:4018
childAction :
created : 2022-12-09T10:53:01.103-08:00
delegated : no
descr : TCA: Total vlan entries
cumulative(eqptcapacityVlanUsage5min:totalCum) value 4018 raised above
threshold 90
dn : topology/pod-1/node-101/sys/eqptcapacity/fault-F193568
domain : infra
extMngdBy : undefined
highestSeverity : critica
lastTransition : 2022-12-09T10:53:01.103-08:00
lc : raised
modTs : never
occur : 1
origSeverity : critical
prevSeverity : critical
rn : fault-F193568
rule : tca-eqptcapacity-vlan-usage5min-total-cum
severity : critical
status :
subject : counter
type : operational
uid :

Fabric Port is Down

The script checks for fault code F1394 with rule ethpm-if-port-down-fabric , which indicate
that ACI has flagged configured Fabric ports for being in a down state.

It is important to understand whether or not these downed fabric prots are preventing your leaf
nodes from having redundant paths. If unexpected, address these issues before performing the
ACI Upgrade.

Failure to do so may lead to outages during switch upgrades due to leaf nodes not having
redundant spine paths.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 39/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Fault Example (F0469: duplicate-subnets-within-ctx)

admin@f1-apic1:~> moquery -c faultInst -f 'fault.Inst.code=="F1394"'


Total Objects shown: 4

# fault.Inst
code : F1394
ack : no
alert : no
annotation :
cause : interface-physical-down
changeSet : lastLinkStChg (New: 2023-10-24T03:24:57.051+00:00),
operBitset (New: 4-5,11,35)
childAction :
created : 2023-09-09T08:53:35.125+00:00
delegated : no
descr : Port is down, reason:err-disabled-link-flaps(err-disabled),
used by:Fabric
dn : topology/pod-1/node-101/sys/phys-[eth1/53]/phys/fault-F1394
domain : access
extMngdBy : undefined
highestSeverity : minor
lastTransition : 2023-10-24T03:24:57.101+00:00
lc : raised
modTs : never
occur : 1
origSeverity : minor
prevSeverity : minor
rn : fault-F1394
rule : ethpm-if-port-down-fabric
severity : minor
status :
subject : port-down
title :
type : communications
uid :
userdom : all
--- omit ---

Configuration Check Details


VPC-paired Leaf switches

High availability (HA) is always the key in network design. There are multiple ways to achieve
this, such as with server configurations like NIC teaming, virtualization technology like VMware
vMotion, or network device technology like link aggregation across different chassis. ACI
provides high availability using virtual Port Channel (vPC) as the link aggregation across
chassis.

It is important to keep the traffic flowing even during upgrades by upgrading one switch in the
same HA pair at a time. In ACI, that will be a vPC pair unless you have other HA technologies
on the server or virtualization side.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 40/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

The script checks if all leaf switch nodes are in a vPC pair. The APIC built-in pre-upgrade
validation performs this check when you upgrade Cisco APICs instead of switches because in
ACI, Cisco APICs are upgraded first prior to switches, and configuring a new vPC pair
potentially requires a network design change and that should be done prior to any upgrades. If
you have other HA technologies in place, you can ignore this validation. vPC is not a
requirement for the upgrade to complete, but the built-in tools to prevent leaf switches in a vPC
domain from upgrading at the same time will not work if they are not in a vPC. If you are not
using vPC, you must ensure the switches being upgraded will not cause an outage if done at
the same time.

Overlapping VLAN Pool

Overlapping VLAN blocks across different VLAN pools may result in some forwarding issues,
such as:

Packet loss due to issues in endpoint learning with vPC

STP BPDUs, or any BUM traffic when using Flood-in-Encap, are not flooded to all ports
within the same VLAN ID.

These issues may suddenly appear after upgrading your switches because switches fetch the
policies from scratch after an upgrade and may apply the same VLAN ID from a different pool
than what was used prior to the upgrade. As a result, the VLAN ID is mapped to a different
VXLAN VNID than other switch nodes. This causes the two problems mentioned above.

VLAN Pools and VXLAN VNID on switches

In ACI, multiple VLANs and EPGs can be mapped to the same bridge domain, which serves as
the Layer 2 domain. As a result, most Layer 2 forwarding, such as bridging or flooding a packet,
uses the VXLAN VNID of the bridge domain. However, each VLAN within the bridge domain is
also mapped to a unique VXLAN VNID, distict from that of the bridge domain. This is known as
Forwarding Domain (FD) VNID or VLAN VNID, and it's used for special purposes such as:

Endpoint synchronization between vPC peer switches.

Flooding STP BPDUs across switches.

Flooding BUM (Broadcast, Unknown Unicast, Multicast) traffic across switches when
Flood-in-Encap is configured on the bridge domain or EPG.

To prevent the impact for these mechanism, VLAN VNID mapping must be consistent across
switches as needed.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 41/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

How VLAN Pools are tied to the VLAN on switches

Each switch port can be associated to multiple VLAN pools that may or may not have VLAN ID
ranges overlapping with each other.

Phy Domain A VLAN Pool 1

Port Interface Policy Group AEP Phy Domain B

VLAN Pool 2

VMM Domain C

When configuring a switch port (node-101 eth1/1) with VLAN 10 as EPG A, two things are
checked:

1. Whether node-101 eth1/1 is associated to VLAN 10 via AEP -> Domain -> VLAN Pool

2. Whether EPG A is associated with the same domain

If the port is associated with multiple domains/VLAN pools as shown above, and EPG A is
associated only with Phy Domain A , then only VLAN Pool 1 is available for the port in the
context of EPG A, avoiding any overlapping VLAN pool issues. However, if VLAN 10 is not
included in VLAN Pool 1 , it cannot be deployed on the port via EPG A. The same principle
applies when deploying a VLAN through AEP binding, as it serves as a shortcut to specify all
ports within the AEP.

This concept of domains is crucial in multi-domain tenancy to ensure the tenant/EPG has the
appropriate set of ports and VLANs.

However, if EPG A is associated with both Phy Domain A and Phy Domain B , the port can use
either VLAN Pool 1 or VLAN Pool 2 to pull a VLAN. If VLAN 10 is configured in both pools, EPG
A and its VLAN 10 are susceptible to an overlapping VLAN pool issue.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 42/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Bad Example 1

Access Policies

VLAN Pool 1
node-101 Domain A
AEP (VLAN 1-20)
eth1/1

VLAN Pool 2
Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1
VLAN 10

In this scenario, VLAN 10 can be pulled from either VLAN Pool 1 or VLAN Pool2 because the
port ( node-101 eth 1/1 ) and the EPG are associated to both pools. And VLAN ID 10 is also
configured on both pools.

As a result, VNID mapping for VLAN 10 on node-101 may become inconsistent after an upgrade
or when the switch initializes and downloads configurations from the APICs.

This can be resolved by associating EPG A to only one of the domains, associating the AEP to
only one of the domains, or associating the domains to the same VLAN Pool as shown below.

Resolution 1:

Access Policies

VLAN Pool 1
node-101 Domain A
AEP (VLAN 1-20)
eth1/1

VLAN Pool 2
Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1
VLAN 10

Resolution 2:

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 43/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Access Policies

node-101
AEP VLAN Pool 1
eth1/1 Domain A
(VLAN 1-20)

VLAN Pool 2
Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1
VLAN 10

Resolution 3:

Access Policies

node-101 Domain A
AEP
eth1/1
VLAN Pool 1
(VLAN 1-20)

Domain B

EPG A
node-101 eth1/1
VLAN 10

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 44/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Bad Example 2

Access Policies

node-101
AEP 2 VLAN Pool 1
eth1/1 Domain A
(VLAN 1-20)

node-101
AEP 1 VLAN Pool 2
eth1/2 Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1-2
VLAN 10

In this scenario, VLAN 10 can be pulled from either VLAN Pool 1 or VLAN Pool2 from the EPG's
perspective. However, each port is associated to only one VLAN pool respectively.

This is a problem because both ports are on the same switch. Essentially, this VLAN Pool design
attempts to map a different VNID for VLAN 10 on eth1/1 and eth1/2 on the same switch, which
isn't allowed - there can be only one VLAN 10 per switch except for when using VLAN scope
local .

As a result, VNID mapping for VLAN 10 on node-101 may become inconsistent after an upgrade
or when the switch initializes and downloads configurations from the APICs.

This can be resolved by associating AEPs to the same domain or associating the domains to the
same VLAN Pool as shown below.

Resolution 1

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 45/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Access Policies

node-101
AEP 2
eth1/1

VLAN Pool 1
Domain A
(VLAN 1-20)
node-101
AEP 1
eth1/2

VLAN Pool 2
Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1-2
VLAN 10

Resolution 2

Access Policies

node-101
AEP 2
eth1/1 Domain A

VLAN Pool 1
(VLAN 1-20)
node-101
AEP 1
eth1/2 Domain B

EPG A
node-101 eth1/1-2
VLAN 10

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 46/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example: good only for a specific use case

Access Policies

node-101
AEP 2 VLAN Pool 1
eth1/1 Domain A
(VLAN 1-20)

node-102
AEP 1 VLAN Pool 2
eth1/1 Domain B
(VLAN 10-20)

EPG A
node-101 eth1/1
node-102 eth1/1
VLAN 10

In this scenario, each port is tied to a different VLAN pool for VLAN 10, but each port is on a
different node. This ensures that the VLAN VNID mapping remains consistent within each node
even after an upgrade, with no ambiguity about which VLAN pool is used. However, VLAN 10 on
each node will map to a different VLAN VNID, which may or may not be your intent.

Without the Flood-in-Encap feature, VLAN VNIDs act as flooding domains for spanning tree
BPDUs. Even if VLAN 10 on node 101 and 102 map to different VLAN VNIDs, regular traffic is
forwarded without issues via bridge domain VNID or VRF VNID.

This VLAN pool design is ideal for keeping the spanning tree domains small, such as in a multi-
pod fabric with one STP domain per pod where each pod is physically separate with no L2
connecitivity between them except for the IPN. It helps contain spanning tree issues within a
single pod. For instance, if Pod 1 continuously receives STP TCNs due to a malfuncationing
device in the external network in Pod 1, the impact of flushing endpoints and causing
connectivity issues due to TCNs is contained within that pod, keeping other pods unaffected.

However, this design is not suitable if you prefer a simpler configuration, if the nodes belong to
the same vPC switch pair, or if the VLAN uses the Flood-in-Encap feature.

It is critical to ensure that there are no overlapping VLAN pools in your fabric unless it is on
purpose with the appropriate understanding of VLAN ID and VXLAN ID mapping behind the
scene. If you are not sure, consider Enforce EPG VLAN Validation under System > System
Settings > Fabric Wide Setting in the Cisco APIC GUI [available starting with release
3.2(6)], which prevents the most common problematic configuration (two domains containing
overlapping VLAN pools being associated to the same EPG).

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 47/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Refer to the following documents to understand how overlapping VLAN pools become an issue
and when this scenario might occur:

Overlap VLAN pool Lead Intermittent Packet Drop to VPC Endpoints and Spanning-tree
Loop

ACI: Common migration issue / Overlapping VLAN pools

Validating Overlapping VLANs in the Cisco APIC Layer 2 Networking Configuration Guide,
Release 4.2(x)

VLAN Pool - ACI Best Practice Quick Summary

VNID Mismatch

A VNID mismatch can arise due to an Overlapping VLAN Pool situation. This verification is
closely tied to the Overlapping VLAN Pool scenario, which often leads to problems post-
upgrade. Nonetheless, if your fabric is currently experiencing any VNID mismatches, you might
encounter the challenges outlined in Overlapping VLAN Pool even without undergoing an
upgrade. This situation also implies the presence of an overlapping VLAN pool configuration,
potentially resulting in a VNID mismatch at a distinct EPG following an upgrade, causing
different impact to your traffic.

L3Out MTU

It is critical to ensure that MTU values on ACI L3Out interfaces and the routers that connect to
them match. Otherwise, when the ACI switch boots up after an upgrade, it may cause problem
during the routing protocol neighborship establishment or exchanging the route information
between peers.

See below for example details on each protocol.

BGP is a protocol which would establish session without MTU consideration. BGP "Open
and Establish" messages are small, but the messages to exchange routes can be huge.

OSPF will fail to form neighborship if the MTU from both end of the link does not match.
However, although it is strongly not recommended, if the side with larger MTU is configured
to ignore MTU to bring up OSPF neighborship, then OSPF neighborship will be formed.

For both protocols, during a border leaf switch upgrade, routing sessions can be teared off due
to a mismatched MTU. When a border leaf switch comes online with a new version, it will bring
up routing peers. After this, when it starts to exchange information about routing prefixes,
frames may need to carry a huge payload containing lots of prefixes. Based on the size of the
table, the update may need a larger frame size which might not reach the other side. The size
of this payload will depend upon local MTU. If the MTU on the other side does not match (if it's
smaller than the local MTU size), then these exchanges will fail, resulting in routing issues.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 48/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

You can check and configure the MTU on L3Out interfaces through Tenant > Networking >
L3Out > Logical Node Profile > Logical Interface Profile > Select interface type .

Tip

You can run the moquery below on the CLI of any Cisco APIC to check the configured MTU of all
L3Out interfaces. Use grep for concise output if necessary, such as this example: egrep
"dn|encap|mtu"

In this example, an L3Out interface with VLAN 2054 is configured with MTU 9000 in tenant TK ,
L3Out OSPF , Logical Node Profile OSPF_nodeProfile , and Logical Interface Profile
OSPF_interfaceProfile .

apic1# moquery -c l3extRsPathL3OutAtt


Total Objects shown: 1

# l3ext.RsPathL3OutAtt
addr : 20.54.0.1/24
--- omit ---
dn : uni/tn-TK/out-OSPF/lnodep-OSPF_nodeProfile/lifp-
OSPF_interfaceProfile/
rspathL3OutAtt-[topology/pod-1/paths-101/pathep-[eth1/12]]
encap : vlan-2054
--- omit ---
mtu : 9000
--- omit ---

Alternatively, you can run fabric <node_id> show interface with your border leaf switch's
node ID as well.

If the MTU shows inherit , the value is inherited from Fabric > Fabric Policies > Policies
> Global > Fabric L2 MTU > default .

Warning

The script checks the MTU of all L3Out interfaces for you. However, you have to run the script on
Cisco APIC, and the Cisco APIC does not have visibility on the MTU value configured on the
connected devices. Therefore, you should manually check the MTU on the connected devices.

BGP Peer Profile at node level without Loopback

Prior to upgrading to release 4.1(2) or later, you must ensure that one of the following two
requirements are met:

A node profile with a BGP Peer Connectivity Profile has a loopback configured for all
switches in the profile, or

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 49/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

BGP Peer Connectivity Profiles are configured per interface.

You can configure the BGP Peer Connectivity Profile per node profile or per interface. The
former is to source the BGP session from a loopback while the latter is to source the BGP
session from each interface.

Prior to release 4.1(2), when a BGP Peer Connectivity Profile is configured at a node profile
without configuring a loopback, Cisco APIC uses another available IP address on the same
border leaf switch in the same VRF as the BGP source, such as a loopback IP address from
another L3Out or an IP address configured for each interface. This has a risk of the BGP source
IP address being changed unintentionally across reboots or upgrades. This behavior has been
changed based on CSCvm28482 and ACI no longer establishes a BGP session through a BGP
Peer Connectivity Profile at a node profile when a loopback is not configured in the node
profile. Instead, a fault F3488 is raised in these situations. This fault cannot be used as a pre-
upgrade check because it is raised only after an upgrade.

Due to this change, when upgrading from an older version to release 4.1(2) or later, a BGP
session is no longer established if the session was generated via a BGP Peer Connectivity
Profile under a node profile and a loopback is not configured in the node profile.

Tip

When multiple interfaces in the same node profile need to establish a BGP peer with the same
peer IP, you might attempt to configure a BGP Peer Connectivity Profile at a node profile without
a loopback so that the same BGP Peer configuration is applied, as a fallback due to the missing
loopback, to each interface in the same node profile. This is because a BGP Peer Connectivity
Profile with the same peer IP address could not be configured at multiple interface profiles
within the same node profile. This limitation was loosened based on CSCvw88636 on 4.2(7f).
Until then, for this specific requirement, you need to configure a node interface per interface
profile and configure the BGP Peer Connectivity Profile at each interface profile in a different
node profile.

L3Out Route Map import/export direction

Prior to upgrading to release 4.1(1) or later, you must ensure that the route map (route profile)
configuration is correct.

Due to the defect CSCvm75395, the following configuration might have worked prior to release
4.1(1) despite the wrong configuration (a mismatch in the direction):

A route map with export direction attached to an L3Out subnet with Import Route Control
Subnet

A route map with import direction attached to an L3Out subnet with Export Route Control
Subnet

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 50/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Where the L3Out subnet means the subnet configured under an External EPG in an L3Out.

However, these wrong configurations will no longer work, which is the expected behavior, after
you upgrade the fabric to release 4.1(1) or later.

Although this method is not the most common or recommended one among many ways to
control the routes being advertised or learned by ACI L3Outs, the correct configuration with this
method should be as follows:

A route map with export direction attached to an L3Out subnet with Export Route Control
Subnet

A route map with import direction attached to an L3Out subnet with Import Route Control
Subnet

Tip

Or alternatively, you can follow the recommended configurations below to control the route
exchange in L3Outs instead:

default-export route map with IP prefix-lists

default-import route map with IP prefix-lists

With this configuration, you don’t need Export Route Control Subnet or Import Route Control
Subnet in the external EPGs, and you can have external EPGs that are dedicated for contracts or
route leaking while you have the full control of routing protocol through route maps just like a
normal router.

Also note that any import direction route maps only take effect when Route Control
Enforcement is enabled for import under Tenant > Networking > L3Out > Main profile .
Otherwise, everything is imported (learned) by default.

L3Out Route Map Match Rule with missing-target

Prior to upgrading to release 5.2(8), 6.0(2) or later, you must ensure that the route map (route
profile) with type Match Prefix AND Routing Policy (type combinable in the object
rtctrlProfile ) does not contain a match rule with the missing-target state.

Each context in an L3Out route-map with type Match Prefix AND Routing Policy creates a
route-map sequence by combining multiple match conditions shown below:

Match rules referenced by the route-map context

L3Out subnets to which the route-map is associated directly or through an L3Out EPG.

BD subnets in a BD to which the route-map is associated

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 51/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Note

Match rule references in a route-map context is located at the following path in the APIC GUI:

Tenants > Networking > L3Outs > (your L3Out) > Route map for import and export
route control > Contexts > Match Rules

Whereas the match rule itself is located at the following path in the APIC GUI:

Tanants > Policies > Protocol > Match Rules

However, prior to the fix of CSCwc11570, when the state of the match rule reference in the
route map was missing-target , that is when the target match rule didn't exist due to a mis-
configuration, no route-map sequence was created even when there were other match
conditions such as L3Out subnets or BD subnets.

After the fix of CSCwc11570, a route-map sequence is created correctly based on other
available match conditions (i.e. L3Out/BD subnets) even when the state of the match rule
reference is missing-target .

Because of this, if users have route maps with type Match Prefix AND Routing Policy and a
match rule reference that resulted in missing-target prior to an upgrade, route-map
sequences that weren't deployed prior to the upgrade may be deployed after the upgrade. This
may change how the routes are exported(advertised) or imported(learned) through an L3Out
after the upgrade.

To avoid an unexpected behavior change after an upgrade, if the route map context has a
match rule reference with missing-target , you should either remove the match rule reference
or update it such that it points to an existing match rule.

Tip

When a match rule reference with missing-target is present for a route map with type Match
Prefix AND Routing Policy prior to the upgrade and prior to the fix of CSCwx11570, the
corresponding route-map context is not functioning. However, the fact that it has not been
functioning without any operational impact indicates that the route map context may not be
needed in the first place. If you remove the match rule reference with missing-target , a new
route-map sequence will be deployed based on other match conditions which may or may not be
needed. Thus, it is important for you to check the original intent of the route-map context and
decide how to resolve it. If the route-map context is not needed in the first place, you would need
to remove the entire route-map context instead of just removing the match rule reference with
missing-target .

L3Out Loopback IP Overlap with L3Out Interfaces

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 52/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

When a loopback IP address in an L3Out is overlapping with a subnet of L3Out interfaces on


the same leaf in the same VRF, only one of them (loopback or L3Out interface) is deployed
even though the configuration is allowed without any faults. As a result, after an upgrade,
what's deployed out of the two may change, and traffic may suddenly stop working after an
upgrade because the interface that used to be deployed prior to the upgrade may be replaced
with the other one.

In an L3Out, there are two ways to configure a loopback IP:

1. Use Router ID as Loopback IP Address.

2. Configure an explicit loopback iP address that may be different from the router ID.

Both options are configured under Tenant > L3Out > Logical Node Profile > (node ID) in
the APIC GUI.

This script checks both options to see if any of them is overlapping with the subnet configured
as the L3Out interfaces under Tenant > L3Out > Logical Node Profile > Logical
Interface Profile in the APIC GUI.

Note that the overlap may happen across different L3Outs. For example, the loopback IP
address is configured on L3Out 1 on node-101 in VRF A while the L3Out interface with the
overlapping subnet is configrued on L3Out 2 on the same node and the same VRF.

Tip

There are other overlapping configurations like overlaps between an L3Out loopback IP address
and a BD subnet. Those are, however, covered by a fault (F1425), which is validated by another
check - BD Subnets (F1425 subnet-overlap).

Tip

The enhancement (CSCwa48038) was made on APIC to prevent users from doing this
conflicting configuration in the first place. However, if the user already had this conflicting
configuration, and proceeded with an upgrade from an older version to the version with the
enhancement, the conflicting configuration remains there with the remaining risk of uncertainty
where we don't know which interface will be deployed after the next upgrade.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 53/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

Alternative to the APIC GUI, you can also check these objects for the loopback IP addresses or
L3Out Interface subnets via API.

Use Router ID as Loopback Address in the APIC GUI corresponds to the object
l3extRsNodeL3OutAtt with rtrIdLoopBack set to yes . In this example, node-103 is
configured with a loopback IP 10.0.0.3 via L3Out BGP in tenant TK .

admin@f1-apic1:~> moquery -c l3extRsNodeL3OutAtt | egrep 'dn|rtr'


dn : uni/tn-TK/out-OSPF/lnodep-IPv4/rsnodeL3OutAtt-[topology/pod-
1/node-103]
rtrId : 10.0.0.3
rtrIdLoopBack : no
dn : uni/tn-TK/out-BGP/lnodep-IPv4/rsnodeL3OutAtt-[topology/pod-
1/node-103]
rtrId : 10.0.0.3
rtrIdLoopBack : yes

Configuring an explicit loopback IP address is done via the object l3extLoopBackIfP which is
optionally configured under l3extRsNodeL3OutAtt when
l3extRsNodeL3OutAtt.rtrIdLoopBack is set to no .

admin@f1-apic1:~> moquery -c l3extLoopBackIfP | egrep 'dn|addr'


addr : 10.0.0.103
dn : uni/tn-TK/out-BGP2/lnodep-IPv4/rsnodeL3OutAtt-[topology/pod-
1/node-103]/lbp-[10.0.0.103]

Note that you need to get the corresponding VRF from the parent L3Out to see which VRF these
loopbacks are deployed.

ISIS Redistribution Metric for MPod/Msite

ISIS Redistribution Metric is used when a spine redistributes routes from another pod or site
into local underlay network (ISIS). If this metric is not set to less than 63, traffic disruption may
occur with an upgrade of spine swithces.

See the ACI Best Practice Quick Summary for details.

This script checks the ISIS Redistribution Metric via redistribMetric of an object
isisDomPol (DN: uni/fabric/isisDomP-default ).

Example

admin@f2-apic1:~> moquery -d uni/fabric/isisDomP-default | grep redistribMetric


redistribMetric : 32

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 54/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

BGP Route-target Type for GOLF over L2EVPN

Prior to upgrading to release 4.2 or later, if you are using the ACI GOLF feature with Explicit
Route Targets, you must ensure that all Explicit Route Targets point to a route-target policy
explicitly configured with a route-target community type instead of extended
(CSCvm23100).

You can verify this configuration under Tenant > VRF > BGP Route Target Profile X >
Route Targets .

Prior to release 4.2 there was an unexpected behavior where a BGP Route Target Profile
containing an extended community type is treated as a route-target community type. This
results in the unexpected configuration and deployment of EVPN route targets for GOLF VRFs:

Used to work unexpectedly prior to 4.2

extended:as4-nn2:1234:1300
extended:as4-nns:1.2.3.4:20

After release 4.2, with the addition of the Stretched L3out feature, route-target community
type enforcement was corrected. Due to this change, when upgrading from an older version to
release 4.2 or later, EVPN Route Target configuration pushed due to an extended community
type will no longer occur, which can lead to an unexpected outage. If found, BGP Route Target
Configuration must be corrected during a window to the route-target type prior to upgrade:

Correct configuration after 4.2

route-target:as4-nn2:1234:1300
route-target:as4-nns:1.2.3.4:20

APIC Container Bridge IP Overlap with APIC TEP

By default, the APIC Container Bridge IP (docker0 interface) for AppCenter uses 172.17.0.1/16.
If this overlaps with the APIC TEP IP range, APICs may not be able to communicate with each
other. Depending on the version, the bridge IP may fallback to 172.18.0.1/16 to avoid the
conflict. However, after an upgrade, the bridge IP may start using 172.17.0.1/16 again, which
can result in an upgrade failure with an unhealthy APIC cluster.

To avoid this, the APIC Container Bridge IP must be expliplicitly configured to be a different
range than the APIC TEP IP range. The APIC Container Bridge IP can be changed from Apps >
Settings in the APIC GUI.

The script checks if the APIC Container Bridge IP is overlapping withe the APIC TEP IP range
via containerBip of an object apContainerPol (DN: pluginPolContr/ContainerPol ).

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 55/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

admin@f2-apic1:~> moquery -d pluginPolContr/ContainerPol | grep containerBip


containerBip : 172.17.0.1/16

Fabric Uplink Scale cannot exceed 56 uplinks per leaf

Prior to release 6.0, the per-leaf fabric uplink count was not enforced. However, surpassing 56
could lead to programming issues on the leaf.

After release 6.0, per-leaf fabric uplink count is enforced via enhancement CSCwb80058. If a
leaf switch has surpassed 56 uplinks and is upgraded, 56 uplinks will come up and the rest will
not.

To avoid this, explicitly modify the port profile uplink scale to be 56 or less per leaf.

The script counts the amount of port-profile provisioned uplinks per leaf, and fails if any leaf is
found to surpass 56.

OoB Mgmt Security

In the configuration of APIC Out-of-Band Management EPG, users can limit the protocols and
source IP addresses that can access APIC nodes.

To prevent accidental blocking of necessary access to APIC, essential access (ICMP, SSH,
HTTP, and HTTPS) to APICs from the same subnet as the APIC OoB IP address is always
permitted, regardless of the contracts and subnets configuration of the OoB Management EPG.

Starting from releases 4.2(7) and 5.2(1), this safeguard implementation was extended to allow
ICMP, SSH, and HTTPS from any source. However, CSCvz96117 reverted this change in release
5.2(3) due to use cases where ICMP, SSH, and HTTPS should only be allowed from a known
secure source — the same subnet as the APIC OoB IP address and other user-configured IP
addresses.

This implies that for users running releases 4.2(7), 5.2(1), or 5.2(2), and when the OoB
Management EPG is configured with contracts to restrict ICMP, SSH and HTTPS access to a
specific subnet, OoB security is not honored, and those can still be allowed from any subnet.
After upgrading to release 5.2(3) or a newer version, OoB Management access to APICs will
only be permitted from the configured subnet or ICMP, SSH, HTTP and HTTPS from the same
subnet as the APIC OoB IP addresses as it were before 4.2(7). This change might catch users
by surprise if they were previously accessing APICs via ICMP, SSH, or HTTPS from a subnet
other than the configured one.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 56/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

The script checks whether you should be aware of this change in behavior prior to your ACI
upgrade so that appropriate subnets can be added to the configuration or you can prepare a
workstation that is within the configured subnet, which will continue to be accessible to APICs
even after the upgrade.

EECDH SSL Cipher

Under Fabric > Fabric Policies > Policies > Pod > Management Access > default ,
there are multiple SSL ciphers which can be enabled or disabled by the user. Cipher states
should only be modified if a configured cipher is declared insecure or weak by the IETF. When
modifying any cipher it is important to validate that the configuration is valid otherwise NGINX
may fail to validate and the GUI will become unusable due to no cipher match. For more
information reference the APIC Security Configuration Guide.

EECDH is a key algorithm that many cipher suites use for HTTPS communication. If the key
algorithm is disabled any cipher suite using this key algorithm will also be implicitly disabled.
Cisco does not recommend disabling EECDH.

When disabled, the nginx.conf configuration file may fail to validate and NGINX will continue to
use the last known good configuration. On upgrade, nginx.conf will also fail to validate but
there is no known good configuration so the APIC GUI will be down until EECDH is re-enabled.

Tip

If the GUI is inaccessible due to the EECDH cipher being disabled, it can be re-enabled from the
CLI using icurl.

apic1# bash
admin@apic1:~> icurl -X POST 'http://localhost:7777/api/mo/uni/fabric/comm-
default/https/cph-EECDH.json' -d '{"commCipher":{"attributes":
{"state":"enabled"}}}'
{"totalCount":"0","imdata":[]}
admin@apic1:~>

BD and EPG Subnet must have matching scopes

Bridge Domains and EPGs can both have subnets defined. Depending on the features in use,
there are 3 scope options that can be applied on these BD and EPG subnets to enable specific
functionality:

Private — The subnet applies only within its tenant. This is the default scope option.

Public — The subnet can be exported to a routed connection. This scope option is used
with matching L3Out definitions to export the subnet outside of the ACI Fabric.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 57/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Shared — The subnet can be shared with and exported to multiple VRFs in the same tenant
or across tenants as part of a "Shared Service" configuration within the ACI Fabric. An
example of a shared service is a routed connection from one VRF having access to an EPG
in a different VRF. The 'shared' scope option is required to enable traffic to pass in both
directions across VRFs.

Before the fix implemented in CSCvv30303, it was possible for a BD and an associated EPG to
have the same subnet defined, but with mismatching scopes. The non-deterministic nature of
ACI meant that policy re-programmings, such as via Upgrade or Clean Reloads, could change
which subnet scope option definition would take affect first, the BD or the EPG, and could result
in a loss of expected traffic flows.

CSCvv30303 introduced policy validations to prevent this configuration and enforce that
matching subnets defined in both the BD and related EPG have the same scope. It is imperative
that identified mismatching subnet scopes are corrected within an ACI fabric to prevent
unexpected traffic pattern issues in the future.

Unsupported FEC Configuration for N9K-C93180YC-EX

Nexus C93180YC-EX switches do not support CONS16-RS-FEC or IEEE-RS-FEC mode. In older


versions a FEC mode misconfiguration does not cause the interface to be down. However after
upgrading to 5.0(1) or later the port will become hardware disabled until the misconfiguration is
removed.

It is important to remove any unsupported configuration prior to ugprade to avoid any


unexpected downtime.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 58/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

On each N9K-C93180YC-EX switch, you can check the FEC mode for each interface with the
following query:

leaf101# moquery -c l1PhysIf -x query-target-filter=or\(eq\


(l1PhysIf.fecMode,\"ieee-rs-fec\"\),eq\(l1PhysIf.fecMode,\"cons16-rs-fec\"\)\)
Total Objects shown: 1

# l1.PhysIf
id : eth1/1
adminSt : up
autoNeg : on
breakT : nonbroken
bw : 0
childAction :
delay : 1
descr :
dfeDelayMs : 0
dn : sys/phys-[eth1/1]
dot1qEtherType : 0x8100
emiRetrain : disable
enablePoap : no
ethpmCfgFailedBmp :
ethpmCfgFailedTs : 00:00:00:00.000
ethpmCfgState : 2
fcotChannelNumber : Channel32
fecMode : ieee-rs-fec <<<

Defect Check Details


EP Announce Compatibility

If your current ACI switch version is pre-12.2(4p) or 12.3(1) and you are upgrading to release
13.2(2) or later, you are susceptible to a defect CSCvi76161, where a version mismatch
between Cisco ACI leaf switches may cause an unexpected EP announce message to be
received by the EPM process on the leaf switch, resulting in an EPM crash and the reload of the
switch.

To avoid this issue, it is critical that you upgrade to a fixed version of CSCvi76161 prior to
upgrading to release 13.2(2) or later.

For fabrics running a pre-12.2(4p) ACI switch release, upgrade to release 12.2(4r) first, then
upgrade to the desired destination release.

For fabrics running a 12.3(1) ACI switch release, upgrade to release 13.1(2v) first, then
upgrade to the desired destination release.

Eventmgr DB size defect susceptibility

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 59/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Due to defects CSCvn20175 or CSCvt07565, the upgrade of APICs may get stuck or take an
unusually long time to complete. Either eventmanager defect results in a database shard with a
replica 0 that grew exceptionally large. This, in turn, increases the time it takes for
dataconvergence to complete.

Root access is required to check the current size of APIC database shards. A Cisco TAC SR is
required for root access.

This script checks if the current version is susceptible to either CSCvn20175 or CSCvt07565.

Contract Port 22 Defect

Due to the defect CSCvz65560, a contract using TCP port 22 is either disabled or programmed
with a wrong value during while upgrading the fabric to 5.0 or a newer version. The issue was
fixed and not observed when upgrading to 5.2(2g) or newer.

The script checks whether the your upgrade is susceptible to the defect from the version point
of view.

telemetryStatsServerP Object

Beginning with the Cisco APIC 5.2(3) release, the telemetryStatsServerP managed object
with collectorLocation of type apic is no longer supported and removed post Cisco APIC
upgrade.

Due to the defect CSCvt47850, if the switches are still on an older version than the 4.2(4)
release the managed object is deleted before the switches are upgraded and this may cause
the switches to become inactive or crash.

To avoid this issue, change the collectorLocation type to none through the API to prevent
the object from being automatically deleted post upgrade.

1. If telemetryStatsServerP exists with collectorLocation="apic" , use the API to change


the collectorLocation type to none .

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 60/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

collectorLocation is set to apic so this fabric is susceptible to CSCvt47850. Use icurl to


change collectorLocation to none .

apic# moquery -c telemetryStatsServerP


# telemetry.StatsServerP
collectorLocation : apic <<<
apic# bash
apic:~> icurl -kX POST
"http://localhost:7777/api/mo/uni/fabric/servers/stserverp-default.xml" -d
'<telemetryStatsServerP status="modified" collectorLocation="none"/>'
apic:~> exit
apic# moquery -c telemetryStatsServerP
# telemetry.StatsServerP
collectorLocation : none <<<

a. Upgrade both Cisco APICs and switches to the target version.

2. After validating that all switches have been upgraded successfully, delete the
telemetryStatsSeverP managed object.

Example

Object can safely be removed from the fabric.

apic# bash
apic:~> icurl -kX POST
"http://localhost:7777/api/mo/uni/fabric/servers/stserverp-default.xml" -d
'<telemetryStatsServerP status="deleted"/>'

Link Level Flow Control

Due to the defect CSCvo27498, after upgrade of first ACI leaf switch in a VPC pair to newer
15.x version from older 13.x version, downstream VPC might be down due to vpc port
channel mis-config due to vpc links in the 2 switches connected to different
partners even though they are connected to same device.

By default Link level Flow control is off in ACI but in older code, the ACI software was
incorrectly signalling far end device to enable transmit flow control. if far end device
transmit(send) flow control in auto or desirable mode, it will enable transmit flow control.

After the first switch in VPC pair is upgraded to newer 15.x code, the incorrect flow control
signalling is fixed. But due to mismatched software versions in ACI during upgrade, the far end
device port-channel member interfaces will end up with mismatched send flow control. When

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 61/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

this happens. they could send a different LACP operational key causing the ACI leaf to interpret
that it is connected to different partners.

The script checks if the version is susceptible to the default along with the specific 1G SFPs
that are affected by the defect.

Internal VLAN Pool

Prior to upgrading to Cisco APIC release 4.2(6) or later, you must ensure that any VLAN encap
blocks that are explicitly used for front-panel ports are set to type external (on the wire). The
encap block type internal is reserved only for AVE deployment. Due to the defect CSCvw33061,
this configuration might have worked prior to release 4.2(6) despite being misconfigured. If you
fail to correct the misconfiguration before you upgrade Cisco APIC, it will result in the affected
VLANs being removed from the front-panel port that can result in a data plane outage.

APIC CA Cert Validation

Due to the defect CSCvy35257, APIC may have a corrupted CA certificate after importing a
backup config without AES encryption. If an upgrade is performed while the CA certificate is
corrupted, spine switches will repeatedly reboot (CSCwc74242).

The script checks if the APIC CA certificate is corrupted or not.

FabricDomain Name

Due to the defect CSCwf80352, ACI switches cannot join the fabric after an upgrade to 6.0(2)
release when the name of the ACI fabric ( fabricDomain in an object topSystem ) containis "#"
or ";".

The script checks if the target version is 6.0(2) and if the fabric name contains "#" or ";".

Spine SUP HW Revision

Due to the defect CSCwb86706, ACI modular spine switches may not be able to boot after an
upgrade depending on the hardware revision (part number) of the SUP modules.

The script checks if the version and the SUP modules are susceptible to the defect.

If this check is flagged, Known Fixed Releases documented in CSCwf44222 should be


assessed as a target image to avoid the defect condition.

CoS 3 with Dynamic Packet Prioritization

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 62/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Due to the defect CSCwf05073, ACI unexpectedly assigning a COS3 value to traffic egressing
front ports.

In certain cases, such as when frames goes through FCoE supported devices, these get
classified into the no drop FCoE class. In FCoE devices, this can cause drop of packets when
the packet length is higher than the allowed 2184 bytes.

For example, on the UCS Fabric Interconnect COS3 value is hardcoded for fiber channel (FC) or
fiber channel over ethernet (FCoE) traffic. FC/FCoE traffic is highly sensitive and is treated as
non-droppable, and cannot exceed MTU of 2184 bytes long.

This script checks if the target version is susceptible to CSCwf05073 and dynamic packet
prioritization feature is set to "on".

SUP-A/A+ High Memory Usage

Due to the increased memory utilization from 6.0(3), N9K-SUP-A or N9K-SUP-A+ will likely
experience constant high memory utilization.

It is highly recommended not to upgrade your ACI fabric to 6.0(3), 6.0(4) or 6.0(5) if your fabric
contains N9K-SUP-A and/or N9K-SUP-A+. Instead, wait for the memory optimization in a near-
future Cisco ACI 6.0 maintenance release that will allow the N9K-SUP-A and N9K-SUP-A+
supervisors to operate in a normal memory condition.

Note

This is also called out in release notes of each version - 6.0(3), 6.0(4), 6.0(5):

VMM Uplink Container with empty Actives

Due to the defect CSCvr96408, affected versions with VMM domains having VMM parameters
changed via the UI could have resulted in fvUplinkOrderCont objects created with the
parameter "active": "" ('active' set to blank). This active parameter defines which uplinks
should be set to active on the Vmware created EPG portgroup, and if blank, results in no active
uplinks. In most cases, traffic issues due to this config were worked-around by manually
modifying the active uplink configuration directly within VMware vCenter.

The issue arises when an upgrade or VMM parameter change occurs. Either change causes a
re-validation of the fvUplinkOrderCont VMM policy as defined in ACI. The result is that any
fvUplinkOrderCont still having active: "" will push a config change into VMware vCenter to
map back to APIC policy, resulting in the removal of active uplinks and a corresponding outage.

This script checks for fvUplinkOrderCont with active: "" and alerts the user to their
existence. The active parameter must match your current active configuration to avoid an

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 63/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

outage on subsequent upgrade of VMM Parameter change.

The example shows a correctly defined fvUplinkOrderCont , with uplinks under the active
field.

Example

apic1# moquery -c fvUplinkOrderCont


Total Objects shown: 1

# fv.UplinkOrderCont
active : 1,2,3,4,5,6,7,8
annotation :
childAction :
descr :
dn : uni/tn-test1/ap-ap3/epg-epg3/rsdomAtt-[uni/vmmp-VMware/dom-test-
dvs]/uplinkorder
extMngdBy :
lcOwn : local
modTs : 2024-04-30T16:15:06.815+00:00
name :
nameAlias :
ownerKey :
ownerTag :
rn : uplinkorder
standby :
status :
uid : 15374
userdom : :all:common:

N9K-C93108TC-FX3P/FX3H Interface Down

Due to the defect CSCwh81430, some RJ45 interfaces on Cisco Nexus N9K-C93108TC-FX3P
and N9K-C93108TC-FX3H Switches might not come up, even when connected.

This issue can be triggered by a switch reload that occurs for any reason, including a software
upgrade, software reset, system crash, or the power being turned up or down.

The problem is related only to the front-panel interfaces Ethernet 1/1- 1/48. Optical ports
Ethernet 1/49 - 54 and MGMT0 port are not affected.

Because of this, the target version of your upgrade must be a version with a fix of CSCwh81430
when your fabric includes those switches mentioned above. See the Field Notice FN74085 for
details.

Invalid FEX fabricPathEp DN References

If you have deployed a FEX on a version prior to having validations introduced in CSCwh68103,
it is possible that fabricPathEp objects were created with an incorrect DN format. As a result,

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 64/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

the related infraRsHPathAtt objects pointing to those fabricPathEp will also contain the
invalid DN in their DN formatting given how ACI builds out object relations.

Having these invalid DNs and then upgrading to a version that has the validations introduced in
CSCwh68103 will result in validation failures while trying to make changes to access policies,
blocking new config from being accepted. The validation failure will present itself with the text
Failed to decode IfIndex, id: 0x....... .

If invalid DNs are found, first identify if the FEX IDs are still in use in case a window needs to be
planned. If not in use, delete the infraRsHPathAtt objects having an invalid DN.

This check queries infraRsHPathAtt objects related to eths, then check if any have DNs which
are incorrectly formatted.

LLDP Custom Interface Description

Due to the defect CSCwf00416, custom interface descriptions may override the port topology
DN. In ACI LLDP should always advertise the topology DN as the port description irrespective
of whether an interface description is configured or not.

In cases where there is a custom interface description and a VMM-integrated deployment with
deploy immediacy set to on-demand, connectivity may break on upgrade. If both of these
features are enabled it is not recommended to upgrade to 6.0(1) or 6.0(2).

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 65/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Note

To check for any custom interface descriptions, you can use the following moquery command.

apic1# moquery -c infraPortBlk -x query-target-filter=ne\


(infraPortBlk.descr,""\)
Total Objects shown: 11

# infra.PortBlk
name : portblock1
annotation :
childAction :
descr : port 30 on Leaf 101 and 103 to FI-B <<< Description is set
dn : uni/infra/accportprof-system-port-profile-node-103/hports-
system-port-selector-accbundle-VPC_FIB-typ-range/portblk-portblock1
--- omit ---

To check for any VMM Domains using on-demand deploy immediacy, you can use the following
moquery command.

apic1# moquery -c fvRsDomAtt -x query-target-filter=and\(eq\


(fvRsDomAtt.tCl,\"vmmDomP\"\),eq\(fvRsDomAtt.instrImedcy,\"lazy\"\)\)
Total Objects shown: 90

# fv.RsDomAtt
tDn : uni/vmmp-VMware/dom-shared-dvs
dn : uni/tn-prod/ap-inet/epg-epg1/rsdomAtt-[uni/vmmp-
VMware/dom-shared-dvs]
instrImedcy : lazy <<< deploy immediacy is
on-demand
tCl : vmmDomP
--- omit ---

Route-map Community Match

Due to the defect CSCwb08081, if you have a route-map with a community match statement
but there is no prefix list match the set clause may not be applied.

It is recommended if you are upgrading to an affected release to add a prefix list match
statement prior to upgrade.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 66/67
11/5/24, 9:11 AM Validation Reference - ACI Pre-Upgrade Validation Script

Example

In this example, the Route-map match rule rtctrlSubjP has a community match
rtctrlMatchCommFactor but no prefix list match rtctrlMatchRtDest . This match rule would be
affected by the defect.

apic1# moquery -c rtctrlSubjP -x rsp-subtree=full -x rsp-subtree-


class=rtctrlMatchCommFactor,rtctrlMatchRtDest | egrep "^#|dn "
# rtctrl.SubjP
dn : uni/tn-Cisco/subj-match-comm
# rtctrl.MatchCommTerm
dn : uni/tn-Cisco/subj-match-comm/commtrm-test
# rtctrl.MatchCommFactor
dn : uni/tn-Cisco/subj-match-comm/commtrm-test/commfct-
regular:as2-nn2:4:15

In order to fix this, navigate to Tenants > "Cisco" > Policies > Protocol > Match Rules >
"match-comm" and add a prefix-list.

apic1# moquery -c rtctrlSubjP -x rsp-subtree=full -x rsp-subtree-


class=rtctrlMatchCommFactor,rtctrlMatchRtDest | egrep "^#|dn "
# rtctrl.SubjP
dn : uni/tn-Cisco/subj-match-comm
# rtctrl.MatchCommTerm
dn : uni/tn-Cisco/subj-match-comm/commtrm-test
# rtctrl.MatchCommFactor
dn : uni/tn-Cisco/subj-match-comm/commtrm-test/commfct-
regular:as2-nn2:4:15
# rtctrl.MatchRtDest
dn : uni/tn-Cisco/subj-match-comm/dest-[0.0.0.0/0]

L3out /32 overlap with BD Subnet

Due to defect CSCwb91766, L3out /32 Static Routes that overlap with BD Subnets within the
same VRF will be programmed into RIB but not FIB of the relevant switches in the forwarding
path. This will cause traffic loss as packets will not be able to take the /32 route, resulting in
unexpecteded forwarding issues.

If found, the target version of your upgrade should be a version with a fix for CSCwb91766.
Otherwise, the other option is to change the routing design of the affected fabric.

https://datacenter.github.io/ACI-Pre-Upgrade-Validation-Script/validations/#overlapping-vlan-pool 67/67

Common questions

Powered by AI

VLAN encapsulation issues should be addressed by either correcting or deleting the conflicting VLAN configuration before upgrading. The fault occurs when a VLAN is already used by another interface for a different purpose, leading to configuration failure upon upgrade if not resolved. It is critical to clear this fault to prevent outages, as the deployment of a faulty policy may impede the functioning of the switch post-upgrade .

To ensure fabric port configurations are compatible with ACI upgrade targets, it is essential to conduct compatibility checks using the APIC Pre-Upgrade Validation Script. This involves validating various configurations such as VLAN pools for overlapping, checking MTU settings, route map configurations, and ensuring that loopback interfaces do not have overlaps with L3Out interfaces. Additionally, confirming compatibility with hardware models and APIC software versions is crucial for a smooth upgrade .

Defects such as APIC CA certificate corruption (CSCvy35257), fabric domain name issues (CSCwf80352), and spine supervisor module hardware revision problems (CSCwb86706) could lead to network failures if not addressed before an upgrade. These defects can cause significant disruptions, including reboot loops, inability to join the fabric post-upgrade, or unbootable spine switches. Proper validation and preemptive adjustments based on known defects are crucial to maintaining network stability during ACI upgrades .

Starting from Cisco APIC release 4.0(1), it is advised to use maintenance group policies for firmware upgrades instead of manually creating firmware group policies. These new policies come with additional attributes that enhance compatibility and ease of use compared to pre-4.0 releases. This change simplifies upgrade processes and ensures consistency across switch configurations by relying on updated maintenance policies .

Virtual APICs can be identified by querying topSystem to check the nodeType attribute, where 'unspecified' denotes a physical APIC and 'virtual' denotes a virtual APIC. During upgrades from ACI 6.0(1) or earlier to 6.0(2) or later, it is necessary to remove virtual APICs from the APIC cluster because the new Linux operating system requires redeployment on the target version. This step is crucial to prevent cluster divergence and ensure a seamless upgrade .

To ensure successful data conversion and post-upgrade callback integrity, it is important to verify that there are no existing defects or inappropriate interventions (e.g., decommissioning or rebooting an APIC) during the upgrade. The upgrade process should be monitored to confirm that the number of objects in the newly created and existing classes match post-upgrade. This ensures that features are extended, enhanced, or optimized without data loss or configuration errors .

Failing to disable problematic features such as App Center apps or Maintenance Mode prior to upgrading or downgrading ACI systems can lead to upgrade failures or system instability. These features need to be disabled to avoid conflicts with the upgrade process, which could result in interrupted services or degraded system performance. Ensuring these features are turned off preemptively mitigates risks associated with system misconfigurations and compatibility issues .

Checking for overlapping VLAN pools is critical prior to an APIC upgrade because such overlaps can lead to network configuration errors that impact both intra- and inter-virtual network performance. Overlapping VLAN pools may cause packet routing conflicts, leading to inefficient network traffic flows and potential packet loss. Identifying and resolving these overlaps ensures that virtual networks operate without unintended VLAN collisions, maintaining network integrity during the upgrade process .

The recommended strategy involves dividing leaf and spine switches into at least two groups for efficient management during ACI firmware upgrades. Grouping should consider the topology and load on the switches to ensure minimal operational disruption. For spine switches, determine grouping based on network core requirements, while leaf switches should be grouped according to their function in access and edge networking. This strategic grouping facilitates easier coordination and reduces risk during upgrades .

Misconfiguring a port in a Layer 3 Out (L3Out) setting by deploying an L2 policy on an L3 port causes the policy to fail because a port in ACI can be either L2 or L3, but not both. In the case of F0467 fault code, when an L3Out policy is deployed on a port that has an L2 policy, the configuration fails due to the conflicting modes. Resolving this fault requires correcting or deleting the interface configuration to prevent issues during future upgrades .