LSC400HN02 8

The document is a preliminary product specification for the Konka LSC400HN02 LCD model, detailing its features, electrical characteristics, and interface requirements. It includes information on maximum ratings, optical characteristics, and input terminal pin assignments. The specification emphasizes compliance with RoHS standards and provides guidelines for handling and storage conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
995 views36 pages

LSC400HN02 8

The document is a preliminary product specification for the Konka LSC400HN02 LCD model, detailing its features, electrical characteristics, and interface requirements. It includes information on maximum ratings, optical characteristics, and input terminal pin assignments. The specification emphasizes compliance with RoHS standards and provides guidelines for handling and storage conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product Specification

( √ ) Preliminary Specification
( ) Approval Specification

The information described in this SPEC is preliminary and can be changed


without prior notice

CUSTOMER Konka MODEL NO. LSC400HN02

DATE OF ISSUE 2015/08/07 EXTENSION CODE -8(0.4T)

‘’

LCD Sales & Marketing Team


Samsung Display Co., Ltd
————————————————————————————————————————————————–

Table of Contents

REVISION HISTORY .......................................................................................................................................................... 3


1. GENERAL DESCRIPTION ............................................................................................................................................. 4
2. ABSOLUTE MAXIMUM RATINGS.............................................................................................................................. 5
3. OPTICAL CHARACTERISTICS ..................................................................................................................................... 6
4. ELECTRICAL CHARACTERISTICS ............................................................................................................................... 9
4.1 TFT LCD MODULE ..................................................................................................................................................... 9
5. INPUT TERMINAL PIN ASSIGNMENT .................................................................................................................... 10
5.1 INPUT SIGNAL & POWER ....................................................................................................................................... 10
5.2 LVDS INTERFACE ..................................................................................................................................................... 12
5.3 INPUT COLOR DATA MAPPING............................................................................................................................. 13
6. INTERFACE TIMING ................................................................................................................................................... 14
6.1 TIMING PARAMETERS OF TIMING (ONLY DE MODE) ............................................................................................ 14
6.2 TIMING DIAGRAMS OF INTERFACE SIGNAL ........................................................................................................ 14
6.3 CHARACTREISTICS OF INPUT DATA OF LVDS ..................................................................................................... 15
6.4 POWER ON/OFF SEQUENCE ................................................................................................................................. 16
7. OUTLINE DIMENSION ............................................................................................................................................... 17
8. PACKING ...................................................................................................................................................................... 18
8.1 CARTON ................................................................................................................................................................... 18
8.2 MARKING ................................................................................................................................................................. 19
9. GENERAL PRECAUTIONS .......................................................................................................................................... 21
9.1 HANDLING .............................................................................................................................................................. 21
9.2 STORAGE ................................................................................................................................................................. 23
9.3 OPERATION ............................................................................................................................................................. 23
9.4 OPERATION CONDITION GUIDE........................................................................................................................... 24
9.5 PROCESS EXECUTING GUIDE................................................................................................................................. 24
9.6 OTHERS .................................................................................................................................................................... 25
10. SPECIAL PRECAUSTIONS........................................................................................................................................ 26
APPENDIX – RECOMMENDATION FOR THE BLU DESIGN .................................................................................... 27

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 2 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

REVISION HISTORY

Date. Rev.No. Page Revision Description


2015/08/07 000 All Initial Release. 0.4T

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 3 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

1. GENERAL DESCRIPTION

DESCRIPTION

This model uses a liquid crystal display (LCD) of amorphous silicon TFT as switching components. This model is
composed of a TFT LCD panel, a driver circuit, and an ass’y KIT of source PBA. This 40.0” model has a
resolution of a 1920 x 1080 and can display up to 1.07 Billion colors with the wide viewing angle of 89° or a
higher degree in all directions. This panel is designed to support applications by providing a excellent
performance function of the flat panel display such as home-alone multimedia TFT-LCD TV and a high
definition TV.

FEATURES
RoHS compliance (Pb-free)
High contrast ratio & aperture ratio with the wide color gamut
SVA mode
Wide viewing angle (± 89°)
High speed response
FHD resolution (1920 x 1080, 16:9)
DE (Data enable) mode
The interface (2Pixel/clock) of 2ch LVDS (Low voltage differential signaling)

GENERAL INFORMATION

Item Specification Unit Note


Active Display Area 885.60 (H) x 498.15 (V) mm
Switching Components a-Si TFT Active matrix
TFT : 899.6(H) x 513.95(V)
Glass size CF : 899.6(H) x 512.15(V) mm ±0.5mm
899.6(H) x 513.95(V) mm ±0.5mm
Panel Size
1.20(D) mm ±0.1mm
Weight TBD g ±10%
Display Colors 1.07B (Dithered 10bit )
Number of Pixels 1920 × 1080 16:9
Pixel Arrangement RGB Horizontal Stripe mm
Display Mode Normally Black
Surface Treatment Anti Glare
Surface Hardness 2H

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 4 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

2. ABSOLUTE MAXIMUM RATINGS

If the figures on measuring instruments exceed maximum ratings, it can cause the malfunction or the
unrecoverable damage on the device.

Item Symbol Min. Max. Unit Note


Power supply voltage VDD -0.3 14.0 V (1)
Temperature for storage
TSTG -20 65 C
(Temperature of glass surface) (2), (4)
Humidity for storage HSTG 5 90 %RH
Operating temperature TOPR 0 50 C
(2), (5)
Operating humidity HSTG 20 90 %RH
Endurance on static electricity 150 V (3)

Note (1) The power supply voltage at Ta= 25 ± 2 °C


(2) Temperature and the range of relative humidity are shown in the figure below.
a. 90 % RH Max. (Ta ≤ 39 °C)
b. The relative humidity is 90% or less. (Ta >39 °C)
c. No condensation
(3) Keep the static electricity under 150V in process the polarizer is attached on glass.
(4) Storage condition with glass.
(5) Operating condition with assembly
(6) Condition without packing.(Unpacking condition)

Fig. Range for temperature and relative humidity (unpacking condition)

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 5 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

3. OPTICAL CHARACTERISTICS

The optical characteristics should be measured in the dark room or the space surrounded by the similar
setting. Measuring equipment : TOPCON RD-80S, TOPCON SR-3 ,ELDIM EZ-Contrast

Ta = 25 ± 2°C, VDD=12.0V, fv=60Hz, fDCLK=148.5MHz, Light source: D65 Standard Light


Item Symbol Condition Min. Typ. Max. Unit Note
(1)
Contrast Ratio CR 3000 4000 - - SR-3
(2)
Response time G-to-G Tg - - 8 16 msec RD-80S
` (3)
Transmissivity T TBD TBD % SR-3
RX TBD
Red
RY Normal TBD
GX qL,R=0 TBD
Color Green
GY qU,D=0 TYP TBD TYP (4),(5)
Chromaticity SR-3
BX -0.03 TBD +0.03
(CIE) Blue
BY Viewing TBD
WX Angle TBD
White
WY TBD
qL 75 89 -
Hor. (5)
Viewing qR CR  10 75 89 - SR-3
Degrees
Angle qU At center 75 89 - EZ-Contrast
Ver.
qD 75 89 -
Color Gamut - TBD - %
Color Temperature - TBD - K

Notice
(a) Setup for test equipment
The measurement should be executed in a stable, windless, and dark room for 40min and 60min after
operating the panel at the given temperature for stabilization of the standard light. (SDC uses the standard
luminance of the D65media).
This measurement should be measured at the center of screen.
The environment condition: Ta = 25 ± 2 °C

(b) D65media has the general light source.


The temperature of color is 6487K. The coordinate of color is Wx 0.313, Wy 0.329
The luminance of this product is 7217cd/㎡.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 6 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

Photo detector Field

SR-3 2°

RD-80S 1°

(c) The CIE positions D65 as the standard daylight illuminant:


[D65] is intended to represent average daylight and has a correlated color temperature of approximately 6500
K. CIE standard illuminant D65 should be used in all colorimetric calculations requiring representative daylight,
unless there are specific reasons for using a different illuminant.

- Definition of the test point

Note (1) Definition of contrast ratio (C/R)


: The ratio of gray max (Gmax) & gray min (Gmin) at the center point ⑤ of the panel
The measurement goes in ELABO-LS Standard light source

G max
C/R
G min

Gmax : The luminance with all white pixels


Gmin : The luminance with all black pixels

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 7 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–
Note (2) Definition of response time

Display data

The response of
optical instruments

※ G-to-G : Average response time between the whole gray scale to the whole gray scale.

The response time is the value that was measured after it was operated in Samsung's standard BLU for one
hour.( at room temperature)

Note (3) Definition of transmittance.


The transmittance at the center point ⑤
The measurement shall be executed with the standard light source of D65 .

Note (4) The definition of chromaticity (CIE 1931)


The color coordinate of red, green, blue and white at the center point ⑤
The measurement shall be executed with the standard light source of D65

Note (5) Definition of viewing angle


: The range of viewing angle (C/R ≥10)
The measurement shall be executed with the standard light source of D65

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 8 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

4. ELECTRICAL CHARACTERISTICS

4.1 TFT LCD MODULE


* Ta = 25 ± 2 °C
Item Symbol Min. Typ. Max. Unit Note
Voltage of power supply VDD 10.8 12.0 13.2 V (1)
Currnet of (a) Black - TBD TBD mA
power (b) White IDD - TBD TBD mA (2),(3)
supply (c) V-stripe - TBD TBD mA
Vsync frequency fV TBD 60 TBD Hz
Hsync frequency fH TBD 67.5 TBD kHz
Main frequency Fdclk TBD 148.5 TBD MHz
Rush current IRUSH - - TBD A (4)

Note (1) The ripple voltage should be controlled fewer than 10% of V DD (Typ.) voltage.
(2) fV=60Hz, fDCLK = 148.5MHz, VDD = 12.0V, DC Current.
(3) Power dissipation check pattern (LCD Module only)

a) Black pattern b) White pattern c) V-stripe

(4) Conditions for measurement

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 9 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

5. INPUT TERMINAL PIN ASSIGNMENT

5.1 INPUT SIGNAL & POWER


Connector : 104234-5117(Molex)
Pin Symbol Description Pin Symbol Description

1 NC NOTE2 26 NC NOTE1

2 NC NOTE2 27 NC NOTE1

3 NC NOTE2 28 Rx2[A]N Even LVDS Signal -

4 NC NOTE1 29 Rx2[A]P Even LVDS Signal +

5 NC NOTE1 30 Rx2[B]N Even LVDS Signal -

6 NC NOTE1 31 Rx2[B]P Even LVDS Signal +

7 NC NOTE1 32 Rx2[C]N Even LVDS Signal -

8 NC NOTE1 33 Rx2[C]P Even LVDS Signal +

9 NC NOTE1 34 GND Ground

10 NC NOTE1 35 Rx2CLK- LVDS Clock -

11 GND Ground 36 Rx2CLK+ LVDS Clock +

12 Rx1[A]N Odd LVDS Signal - 37 GND Ground

13 Rx1[A]P Odd LVDS Signal + 38 Rx2[D]N Even LVDS Signal -

14 Rx1[B]N Odd LVDS Signal - 39 Rx2[D]P Even LVDS Signal +

15 Rx1[B]P Odd LVDS Signal + 40 Rx2[E]N (Note 3) Even LVDS Signal -

16 Rx1[C]N Odd LVDS Signal - 41 Rx2[E]P (Note 3) Even LVDS Signal +

17 Rx1[C]P Odd LVDS Signal + 42 NC NOTE1

18 GND Ground 43 NC NOTE1

19 Rx1CLK- LVDS Clock - 44 GND Ground

20 Rx1CLK+ LVDS Clock + 45 GND Ground

21 GND Ground 46 GND Ground

22 Rx1[D]N Odd LVDS Signal - 47 NC NOTE1

23 Rx1[D]P Odd LVDS Signal + 48 12V DC power supply

24 Rx1[E]N (Note 3) Odd LVDS Signal - 49 12V DC power supply

25 Rx1[E]P (Note 3) Odd LVDS Signal + 50 12V DC power supply

51 12V DC power supply

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 10 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–
Note (1) No connection: These PINS are used only for the product of SAMSUNG.
(DO NOT CONNECT the input device to these pins.)

Note (2) Pin No. 1, 2, 3 are used only for I2C communication in flicker tuning.
(Refer to 10.5 Process Executing Guide)

Note (3) If set input is 8bit LVDS signal, Keep Echannel level ‘0’

Pin No.24 / Pin No.40 : Pull up(3.3V) with 1.5kohm


Pin No.25 / Pin No.41 : Pull down(GND) with 1.5kohm

Note (4) LVDS signal pin have Negative/positive 100ohm as termination resister

Note (5) 100ohm serial damping resister is connected except LVDS signals

Note (6) Optional signal sequence


. On : VDD(T1) → Option → Interface Signal(T2)
. Off : Interface Signal(T3) → Option → VDD

Note (7) Pin number which starts from the left side.

a. Power GND pins should be connected to the LCD’s metal chassis.


b. All power input pins should be connected together.
c. All NC pins should be separated from other signal or power.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 11 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

5.2 LVDS INTERFACE


- LVDS receiver : T-con(merged)
- Data format
LVDS pin JEIDA -DATA

TxIN/RxOUT0 R4

TxIN/RxOUT1 R5

TxIN/RxOUT2 R6

TxOUT/RxIN0 TxIN/RxOUT3 R7

TxIN/RxOUT4 R8

TxIN/RxOUT6 R9

TxIN/RxOUT7 G4

TxIN/RxOUT8 G5

TxIN/RxOUT9 G6

TxIN/RxOUT12 G7

TxOUT/RxIN1 TxIN/RxOUT13 G8

TxIN/RxOUT14 G9

TxIN/RxOUT15 B4

TxIN/RxOUT18 B5

TxIN/RxOUT19 B6

TxIN/RxOUT20 B7

TxIN/RxOUT21 B8

TxOUT/RxIN2 TxIN/RxOUT22 B9

TxIN/RxOUT24 HSYNC

TxIN/RxOUT25 VSYNC

TxIN/RxOUT26 DEN

TxIN/RxOUT27 R2

TxIN/RxOUT5 R3

TxIN/RxOUT10 G2

TxOUT/RxIN3 TxIN/RxOUT11 G3

TxIN/RxOUT16 B2

TxIN/RxOUT17 B3

TxIN/RxOUT23 RESERVED

TxIN/RxOUT28 R0

TxIN/RxOUT29 R1

TxIN/RxOUT30 G0
TxOUT/RxIN4
TxIN/RxOUT31 G1

TxIN/RxOUT32 B0

TxIN/RxOUT33 B1

TxIN/RxOUT34 RESERVED

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 12 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

5.3 INPUT COLOR DATA MAPPING

Note (1) Definition of gray : Rn: Red gray, Gn: Green gray, Bn: Blue gray (n=gray level)
Note (2) Input signal: 0 =Low level voltage, 1=High level voltage

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 13 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

6. INTERFACE TIMING
6.1 TIMING PARAMETERS OF TIMING (Only DE Mode)
Signal Item Symbol Min. Typ. Max. Unit Note
Clock 1/TC TBD 148.5 TBD MHz -
Hsync Frequency FH TBD 67.5 TBD KHz -
Vsync FV TBD 60 TBD Hz -
Term for the Active display
TVD 1080 Lines -
Vertical period
Display Total vertical TV TBD 1125 TBD Lines -
Active display
Term for the THD 1920 Clocks -
Period
Horizontal
Total
Display TH TBD 2200 TBD clocks -
Horizontal
Note) These products don’t have to receive the signal of Hsync & Vsync from the input device.
(1)Key points when testing: TTL controls the signal and the CLK at the input terminal of LVDS Tx of the system.
(2) Internal VDD = 3.3V
(3) Spread spectrum
* The limit of spread spectrum's range of SET : ± TBD %.
Modulation frequency : TBD kHz

6.2 TIMING DIAGRAMS OF INTERFACE SIGNAL

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 14 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

6.3 CHARACTREISTICS OF INPUT DATA OF LVDS


ITEM SYMBOL Min. Typ. Max. UNIT NOTE

Differential input high VTH - - 120 mV VCM=1.2V


threshold voltage

Differential input low VTL -120 - - mV


threshold voltage
Input common mode voltage VCM 0.3 1.2 1.8 V
Differential Input Voltage |VID| 120 - 600 mV

tRSRM - - 400 ps
Input data position FIN=80MHz
tRSLM -400 - - ps

Notice The spread spectrum should be 0% when the skew is measured.


Position of a measurement is T-CON LVDS input pin

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 15 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

6.4 POWER ON/OFF SEQUENCE


To prevent the product from being latched up or the DC in the LCD module from starting an operation, the
order to turn the power on and off should be changed to the order as shown in the diagram below.

T1 : The VDD rising time from 10% to 90%


T2 : The time from the point which VDD reach to 90% of voltage to the point which the valid data is out when
the power is on.
T3: The time from the point which the valid data is out to the point which V DD reach to the 90% of voltage
when the power is off.
T4: the time from the point which the Vdd decrease to the point which the Vdd increase again for windows to
restart.
T5: The time which takes for B/L to be turned on after the signal is entered when the time is on.
T6 : The time which takes until the signal is out after BL is turned off

 The condition of supply voltage to enter in the module from the external system should have the same
condition as the definition of VDD.
 Apply the voltage for the lamp within the range which the LCD operates. when the back light is turned on before
the LCD is operated or when the LCD is turned off before the back light is turned off, the display may show the
abnormal screen momentarily.
 While the VDD is off level, please keep the level of input signals low or keep a high impedance condition.
 The figure of T4 should be measured after the module has been fully discharged between the periods when the
power is on and off.
 The interface signal must not keep the high impedance condition when the power is on.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 16 of 36 Rev.No. 06-000-G-20150807
ACTIVE CENTER
————————————————————————————————————————————————–

8. PACKING
8.1 CARTON
(1) Packing Form
Corrugated Card board box as shock absorber.
(2) Packing Method

(3) Packing Material

Specification Weight Q’ty/PLT


Item
WxLxH (mm) g pcs
Packing Tray 1110*730*115 TBD TBD

Pallet 1480*1130*132 TBD TBD

LCD 899.6*513.95*1.4 TBD TBD

Tray Top 1110*730*30 TBD TBD

Cushion pad 955.3*611.9*2.3 TBD TBD

Silica gel TBD TBD

Paper Box 1474*1124*1045 TBD TBD

Stack Layer max TBD TBD

Total Size TBD

Total/Weight TBD

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 18 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

8.2 MARKING
A nameplate is affixed to the specified location on each product.

(1) S-PCB (for SDC internal use)

LSC400HN02 – XXX

(2) Pol protection film

LSC400HN02-XXX

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 19 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–
(1)Parts number : LSC400HN02
(2)Revision code : 3 letters
(3)Lot number :X X X X XXX XX X

Panel number
Cell ID
Lot ID
Month
Year
Product Code
Line
th
(4) Weekcode : 1205( ex. 2012 year, 5 week)

(5) Nameplate Indication

LJ94-XXXXXX
LSC400HN02-X
14

(6) Packing box attach

LJ94-XXXXXX
LSC400HN02-X
280

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 20 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

9. GENERAL PRECAUTIONS
9.1 HANDLING

(a) When the panel kit and BLU kit are assembled, the panel kit and BLU kit should be attached to the set
system firmly by combining each mounted holes. Be careful not to give the mechanical stress.

(b) Be careful not to give any extra mechanical stress to the panel when designing the set, and BLU kit.

(c) Be cautious not to give any strong mechanical shock and / or any forces to the panel kit.
Applying the any forces to the panel may cause the abnormal operation or the damage to the panel kit and
the back light unit kit.

(d) Refrain from applying any forces to the source PBA and the drive IC in the process of the handling or
installing to the set. If any forces are applied to the products, it may cause damage or a malfunction in the
panel kit.

(e) Refrain from applying any forces which cause a constant shock to the back side of panel kit, the set
Design and BLU kit. If any forces are applied to the products, it may cause an abnormal display, a functional
failure and etc.

(f) Note that polarizer could be damaged easily.


Do not press or scratch the bare surface with the material which is harder than a HB pencil lead.

(g) Wipe off water droplets or oil immediately. If you leave the droplets for a long time on the product, a
staining or the discoloration may occur.

(h) If the surface of the polarizer is dirty, clean it using the absorbent cotton or the soft cloth.

(i) Desirable cleaners are water or IPA (Isopropyl Alcohol).


Do not use Kenton type materials (ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid or Methyl chloride. These
might cause the permanent damage to the polarizer due to chemical reaction.

(j) If the liquid crystal material leaks from the panel, this should be kept away from the eyes or mouth.
If this contacts to hands, legs, or clothes, you must washed it away with soap thoroughly and see a doctor
for the medical examination.

(k) Protect the panel kit and BLU Kit out of the static electricity. Otherwise the circuit IC could be damaged.

- Reference : Process control standard of SDC


No. Item Control standard

1 Ionizer All Equipment should be controlled under 150V.(Typ. 100V)

2 Carrying Roller Carrying Roller should be controlled under 200V.

3 Equipment Ground Resistance All Equipment Ground Should be less than 1ohm.

(l) Remove the stains with finger-stalls wearing soft gloves in order to keep the display clean in the process of
the incoming inspection and the assembly process.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 21 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–
(m) Do not pull or fold the source drive IC which connects to the source PBA and the panel or the gate drive
IC.

(n) Do not pull, fold or bend the source drive IC and the gate drive IC in any processes.
If not, the source drive IC could be bent one time in the process of assembling the panel Kit and the BLU
Kit.

(o) Do not adjust the variable resistor located on the panel kit and BLU kit except when adjusting the flicker.

(p) Do not touch the pins of the interface connector directly with bare hands.

(q) Be cautious not to be peeled off the protection film.

- Make sure to peel off slowly


(It is recommended to peel it off at the speed of more than
8sec. constantly.)
- The peeling direction is shown at the Fig
- Instruct the ground worker to work with the adequate
methods such as the antistatic wrist band.
- Maker sure to be grounded the source PBA while peeling of
the protection film.
- Ionized air should be blown over during the peeling
- The protection film should not t be contacted to the source
drive IC.
- If the adhesive stains remain on the polarizer after the
protection film is peeled off, please move stains with
isopropyl-alcohol liquid.

(r) The protection film for the polarizer on the panel kit should be slowly peeled off just before using so that
the electrostatic charge can be minimized.

(s) The panel kit and BLU kit have high frequency circuits. The sufficient suppression to the EMI should be
done by the set manufacturers.
(t) The set of which the panel is assembled shall not be twisted. If the product is twisted, it may cause the
damage on the product.
(u) Surface Temp. of IC should be controlled less than 100℃, operating over the Temp. can cause the damage
or decrease of lifetime.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 22 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

9.2 STORAGE
The storage condition for packing
ITEM Unit Min. Max.
Storage
(℃) 5 40
Temperature
Storage
(%rH) 35 75
Humidity
Storage life 6 months
(1) The storage room should provide good ventilation and temperature control.
(2) Products should not be placed on the floor, but on the Pallet away from a wall.
(3) Prevent products from direct sunlight, moisture nor water; Be cautious of a buildup of
condensation.
(4) Avoid other hazardous environment while storing goods.
Storage
(5) If products delivered or kept in conditions of the recommended temperature or humidity,
Condition
we recommend you leave them at a circumstance which is shown in the following table.

period 1 month 2 months 3 months 4 months 5 months 6 months

Baking 50℃, 10%


No Baking 50℃, 10%, 48Hr
Condition 24Hr

9.3 OPERATION
(a) Do not connect or disconnect the FFC cable during the "Power On" condition.

(b) Power supply should be always turned on and off by the "Power on/off sequence"

(c) The module has high frequency circuits. The sufficient suppression to the electromagnetic interference
should be done by the system manufacturers. The grounding and shielding methods is important to minimize
the interference.

(d) The cables between TV SET connector and Control PBA interface cable should be connected directly to
have a minimized length. A longer cable between TV SET connector and Control PBA interface cable maybe
operate abnormal display

(e) Recommend to age for over 1 hour at least in the state, which the product is driving initially to stabilize the
characteristic of the initial TFT.

(f) Response time depends on the temperature.( In Lower temperature, it becomes longer)

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 23 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

9.4 OPERATION CONDITION GUIDE


(a) The LCD product shall be operated under normal conditions.
The normal condition is defined as below;
- Temperature : 20± 15℃
- Humidity : 55± 20%
- Display pattern : continually changing pattern (Not stationary)

(b) If the product will be used under extreme conditions such as under the high temperature, humidity,
display patterns or the operation time etc.., it is strongly recommended to contact SDC for the advice about
the application of engineering . Otherwise, its reliability and the function may not be guaranteed. Extreme
conditions are commonly found at airports, transit stations, banks, stock markets, and controlling systems.

9.5 PROCESS EXECUTING GUIDE


(a) Aging
Be sure to age for over 1 hour at least, which the product is driving initially to stabilize TFT Characteristic.
(b) Flicker Adjustment
(1) Flicker should be adjusted by optimizing the Vcom value in customer LCM Line through the I2C Interface.
(Master & Slave = I2C communication )

Pin. No. Symbol Function Remark


Default : 0V
Vcom tunning : 3.3V
1 TCON_WP EN
(Shouldn’t be communicated with I2C device as output level
“5V”)

2 SCL_I I2C Interface


I2C Bus Interface
3 SDA_I I2C Interface

(2) Flicker should be tuned by correct method according to gamma IC type of each model and
(LSC400HN02 – “PMIC type”)

Type Flicker data saving position Slave Address

Genie Type Gamma IC memory


Write B0 = “0”/Read B0 =”1”
Genie-lite Type T-con EEPROM 1110101 (EEPROM data Address : 8161)

PMIC Type T-con EEPROM 10011111

(3) Flicker should be adjusted the pattern, where are displayed alternately at Sub-1-dot (32/64Gray)

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 24 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

< Flicker Adjust Circuit Block Diagram >

9.6 OTHERS
(a) The ultra-violet ray filter is necessary for the outdoor operation.

(b) Avoid the condensation of water which may result in the improper operation of product or the
disconnection of electrode.

(c) Do not exceed the limit on the absolute maximum rating. (For example, the supply voltage variation, the
input voltage variation, the variation in content of parts and environmental temperature, and so on) If not,
panel may be damaged.

(d) If the module keeps displaying the same pattern for a long period of time, the image may be remained to
the screen. To avoid the image sticking, it is recommended to use a screen saver.

(e) This Panel has its circuitry of PCB's on the rear side, so it should be handled carefully in order for a force
not to be applied.

(f) Please contact the SDC in advance when the same pattern is displayed for a long time

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 25 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

10. SPECIAL PRECAUSTIONS


No Component Expected cause
.

Prevent the panel from breaking by assigning gaps between the panel and the upholding part for panel on the
1 Upholding part for drawing for the upholding part for panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.

The shape of the Design the upholding part for panel to fit to the panel appropriately when designing the BLU since the shape of the
2 upholding part for upholding part for panel may damage the panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.

The edge of Design the edge of panel to have a sufficient space with the upholding part for panel when designing the BLU since
3 upholding part for the edge of the upholding part for panel may damage the panel when assembling the panel and BLU.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.

Place the upholding part for the panel in order for the shape of mold, which contacts with the panel not to interfere
4 Upholding part for with the area of panel.
panel Refer to the (a), (b), (c) of 3-1 for the design of BLU.

Design the BLU in order for the COF not to contain the lead crack resulted from the tensioned COF created when the
5 Drive IC product is twisted if the space between the D-IC COF and the middle mold isn't sufficient.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.

Design the BLU in order for the product not to contain the lead crack resulted from the tensioned COF caused under
6 Drive IC the condition, which the product is twisted by fixing the source PCB.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.

1) The temperature of each part of product suggested by our company and the second vendor shall meet the
IC standard of temperature, which is recommended not to be exceeded by our company when the product is affected
7 component under the various temperature ranges.
Apply over 1mm long separation distance stated in the safety standard between the electric part and each
conductor. (Apply the rated separation distance when insulating.)

8 Thermal pad Apply the thermal pad in a designated size to the product as a measure to lower the temperature of heat in order
for each part to use the rated temperature.
The surrounding area of the POL shall be treated with an electrification treatment since the external ESD may cause
9 POL a phenomenon, which the POL is coming off.
In addition, the GND portion of source PBA shall be grounded.

10 PBA The GND portion of each PBA shall be contacted with the GND portion of BLU.
Refer to the (a) and (b) of 3-3 for the design of BLU.

11 Circuit The standardized approval from the client is required since the EMI is executed by a client.
Our company can only measure the reference since the client measures the BLU.

12 The height of Design the BLU with considering the maximum height of parts, which our company suggests.
component

13 Between the FFC and Design the instrument with considering the length between the FFC and the control PBA.
the C-PBA (The marginal minimum length of 5mm or 8mm is required.)
The surface temperature of panel shall be maintained within 0℃ and 45℃ when the external ambient temperature is
14 Panel
at 25℃. (Design the BLU with considering the increase of the temperature in the panel by the LED, CCFL, and etc.)

15 Aging Recommend to age for over 1 hour at least in the state, which the product is driving initially to stabilize the
characteristic of the initial TFT.
16 The attachment
gasket
of The additional confirmation by our company is required If the attachment of gasket to the S-PBA of our company is
required.(To fix the S-PBA or the EMI)
Design the top chassis and the driver IC to be contacted by placing the shape of emboss inside the top chassis as a
17 Drive IC measure to prevent the driver IC from heating. The size of emboss shall be designed in larger size than the size of IC
inside the film of the driver IC.
Refer to the (a), (b), (c),(d),(e),(f), and (g)of 3-2 for the design of BLU.
18 The prohibited Design the BLU in order for the BLU not to interfere with the area, where the control PBA and the source PBA are
bandwidth located densely according to the drawing for the BLU from our company.
The material, which contacts with the bottom side of S-PBA which has a pattern shall be non-conducting material or
19 S-PBA shall be insulated.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 26 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

Appendix – RECOMMENDATION FOR THE BLU DESIGN


1. The schematic of panel

Item Symbol Remark

Protector Film ① Removable

Polaroid Film ②

Color Filter Glass ③

TFT Glass ④

Source IC ⑤

Gate IC ⑥

Source PBA ⑦

FFC ⑧

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 27 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

2. The guide for the mechanical design

2.1 The panel guide


(a) When the panel guiding part is made of plastic resin, the gap between the panel and the guiding
structure should be considered at the design process. The shrinkage of the plastic resin under the
temperatures change can cause the light leakage. The gap should be determined to cover the
temperature change from the guarantee condition and the BLU structure. SDC recommends the
total gap between the panel and the guide structure as below, but the suggested dimension does
not guarantee the quality of the products.

(b) It is recommended to follow the dimension and the shape of the guiding structure illustrated as
below since the distortion of the panel can cause the light leakage.

Chamfer
Over 20mm

Round

(c) When the panel guide is designed to be located at the corner of the BLU, the edge point of the
panel shall not be in contact with the panel guide structures to prevent the crack of the panel caused
by the burr at the edge of the glass. The distance larger than 2.5mm as shown in the picture is
recommended.
(※ Suggested dimension does not guarantee the quality of the products.)

Over 2.5mm

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 28 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

(d) It is recommended to keep the distance between the panel guides and other ribs over 1mm. If
the ribs are placed at the same line with the panel guide, panel broken can be happen when the
operator makes the mistake by placing the panel on the top of the ribs.
(※ Suggested dimension does not guarantee the quality of the products.)

Panel Guide

Over 1.0mm

(e) The gap between the panel guide and the front cover (or front chassis) should be zero in z-
direction. If there is gap, the panel is easily stuck into the gap and can be broken by external forces.

Zero Gap
Panel Guide

2.2 The COF and the Drive IC


(a) It is recommended to secure sufficient gap between the COF and the other parts, since the lack
of gap can cause the damage on the COF such as the lead crack, under the vibration and twist
condition.
(※ Over 3.0mm for moving space is recommended, but the suggested dimension does not
guarantee the quality of the products.)

COF moving space

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 29 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

(b) The pattern of COF can be damaged at the sharp edge of the press part and the burr of mold
part under the vibration condition. Therefore, it is recommended to avoid placing the gate position
and parting line of the injection mold and sharp structure of metal parts around the COF.

(c) The temperature of the surface of Drive-IC should be less than 125℃.

(d) Sufficient space for the COF and the Drive-IC should be secured to prevent the damage on the
Drive-IC from external forces by adding the ribs around COF. And it is also important to reduce the
gap between the ribs and the front cover as small as possible
Front Cover

Ribs
Ribs

(e) It is recommended to make ribs for protecting Drive-IC as close as possible from the COF,
otherwise forces from outside can deform the front cover and damage to the D-IC.

External Forces

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 30 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

(f) When metal parts are assembled next to the Drive-IC, the metal part should be insulated to avoid
the damage on Drive-IC from electrostatic discharge.

Drive-IC

Insulation
Chassis (Metal)

(g) If the length of COF is designed to be short, the lead crack can be occurred by applying the
tension on the COF due to the drop, vibration and twist of the product.

(h) It is recommended that the source PCB should be easily moved in the direction which is parallel
to the longer side of the panel, in order for the tension not to be applied to the COF under vibrating
condition, such as transportation of the product.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 31 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

(I) It is suggested to make the holding structures of source PCB at the positions which is provided by
SDC. They are marked at the 2D drawing and named as ‘PCB guide area’.

SR Open

Forbidden Area
(PCB Guide Area)
24

2.3 The control PBA and the Source PBA


(a) The gap between the circuit parts of the source PBA (or control PBA) and other parts should be
considered to avoid damage on electrical parts by the static electrostatic discharge, short and
external forces. If the shielding part is made of metal and if there is not enough distance from circuit
parts, adding insulation is recommended. SDC will provide maximum height of circuit parts with 2D
and 3D drawing, each customer can decide the distance under consideration of the material,
thickness and other characteristics.

3D Drawing Circuit Component’s max. height : X.XX mm

2D Drawing

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 32 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

2. 4 The 4-Corner and the cloudy light leakage


(a) SDC recommends to design in a way that the heat from light source should be dissipated
effectively. For example, it is recommended to make the contact area between the heat sink and the
bottom chassis to be maximized. The sharp change of temperature or the large temperature
gradient in the surface of panel can cause the light leakage.

Contact Design

Aluminum Bar

Bottom Chassis (Metal)

(b) The distortion of the panel by the lack of the stiffness of BLU can cause the light leakage and
therefore it is recommended to design strong structure against distortion, such as place the strong
beads at the corner of BLU to control the flatness of the panel.

Bead or Forming

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 33 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

2.5 ESD
(a) This Guide is related to the issue of Line Defect (Vertical & Horizontal).
: Contact design between Panel and Top chassis or Front chassis by conductive rubber.
All four sides of conductive rubber need to be contacted with GND.

(b) This Guide is related to the issue of Block Defect & No display.
: Contact design between Top chassis and Bottom chassis, directly

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 34 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

(c) This Guide is related to the issue of Block Defect & No display. (For prevent the CDM during
assembly procedure)
: Conducted design between S-PBA and Bottom Chassis by conductive rubber.

(d) This Guide is related to the ESD soft-fail by Driving IC latch up.
: Do design minimizing current path close to the Driving IC

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 35 of 36 Rev.No. 06-000-G-20150807
————————————————————————————————————————————————–

2.5 Others
(d) Sharp or the round shape near the panel should be changed to flat shape, such as screw point,
gate point of the injection mold etc. Since the panel can be damaged by the concentrated force of
the convex point when there is external force.

Risk Point

(b) It is recommended to design the temperature of the active area below 50℃ at room temperature for
the protection from abnormalities in the screen due to the deterioration of the liquid crystal. In addition,
each customer needs to consider all the guarantee conditions connected with temperature for this
problem not to happen.

——————————————————————————————————————————————––—
Doc.No. LSC400HN02 Page 36 of 36 Rev.No. 06-000-G-20150807

You might also like