ITSPL2425070-Random Vibration Test r1

The document is a test report (No. ITSPL2425070) from Impact Calibration and Testing Solutions for a Random Vibration Test conducted on a Rugged Panel PC-PPC-04 for M/s. Datasol (B) Private Limited. The test aimed to verify the product's functionality under vibration exposures, and it was conducted from May 15 to May 17, 2024, with no physical abnormalities observed post-test. The report includes detailed sections on test execution, equipment used, and results, and is marked as confidential.

Uploaded by

rakesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views31 pages

ITSPL2425070-Random Vibration Test r1

The document is a test report (No. ITSPL2425070) from Impact Calibration and Testing Solutions for a Random Vibration Test conducted on a Rugged Panel PC-PPC-04 for M/s. Datasol (B) Private Limited. The test aimed to verify the product's functionality under vibration exposures, and it was conducted from May 15 to May 17, 2024, with no physical abnormalities observed post-test. The report includes detailed sections on test execution, equipment used, and results, and is marked as confidential.

Uploaded by

rakesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

M/s.

ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

IMPACTCALIBRATION AND TESTING SOLUTIONS PRIVATE LIMITED


No. B5 2nd Cross, ITI Industrial Estate, Mahadevapura Bangalore 560048
Test report no. – ITSPL2425070
Title – Test Report
Random Vibration Test on “Rugged Panel PC-PPC-04”
Submitted to – M/s. Datasol (B) Private Limited

1.0 Test Summary

1.1 Purpose of Test

To verify the DUT will function in and withstand the vibration exposures of a life cycle.

1.2 Product Details

Sl. no. Product name Serial. No KB. Serial No Part. No Date of Start Date of End
68-2023,116-2024,
23-2023,96-2023,
015,016,017,
73-2023,98-2023,
018,019,020,
Rugged Panel 143-2024,130-2024,
01 021,022,023, XL94141 15th May 2024 17th May 2024
PC-PPC-04 72-2023,102-2023,
024,025,026,
137-2024,94-2023,
027,028,029
86-2023,45-2023,
95-2023

1.3 Test Details

[Link]. Type of Test Quantity Observation Result


No physical abnormalities noticed
01 Random Vibration 15 Test completed
on the sample after test

Prepared by Verified by Authorised by

(Renuka R) (Shreya. S) ([Link] Rao)


Test Engineer Senior Engineer Technical Manager

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 1 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

Table of Contents
Contents
1.0 Test Summary ......................................................................................................................................... 1
1.1 Purpose of Test ................................................................................................................................... 1
1.2 Product Details ................................................................................................................................... 1
1.3 Test Details ......................................................................................................................................... 1
2.0 Amendment details ................................................................................................................................ 5
3.0 Scope of Work ........................................................................................................................................ 5
4.0 General Information ............................................................................................................................... 5
5.0 Information / Data provided by customer ............................................................................................. 5
6.0 Sample Details ........................................................................................................................................ 6
7.0 Details of Equipment and Instruments used .......................................................................................... 6
8.0 Test Execution ........................................................................................................................................ 6
8.1 Random vibration Test ....................................................................................................................... 6
8.2 Before Test Image............................................................................................................................... 7
8.3 Test set up picture .............................................................................................................................. 7
9.0 Test Graph .............................................................................................................................................. 8
9.1 X-Axis (Serial No-015) ......................................................................................................................... 8
9.2 X-Axis (Serial No-016) ......................................................................................................................... 8
9.3 X-Axis (Serial No -017) ........................................................................................................................ 9
9.4 X-Axis (Serial No -018) ........................................................................................................................ 9
9.5 X-Axis (Serial No -019) ...................................................................................................................... 10
9.6 X-Axis (Serial No -020) ...................................................................................................................... 10
9.7 X-Axis (Serial No -021) ...................................................................................................................... 11
9.8 X-Axis (Serial No -022) ...................................................................................................................... 11
9.9 X-Axis (Serial No -023) ...................................................................................................................... 12
9.10 X-Axis (Serial No-024) ....................................................................................................................... 12
9.11 X-Axis (Serial No-025) ....................................................................................................................... 13
9.12 X-Axis (Serial No-026) ....................................................................................................................... 13
9.13 X-Axis (Serial No-027) ....................................................................................................................... 14
9.14 X-Axis (Serial No-028) ....................................................................................................................... 14
9.15 X-Axis (Serial No-029) ....................................................................................................................... 15
This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 2 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.16 Y-Axis (Serial No-015) ....................................................................................................................... 15


9.17 Y-Axis (Serial No-016) ....................................................................................................................... 16
9.18 Y-Axis ( Serial No -017) ..................................................................................................................... 16
9.19 Y-Axis (Serial No -018) ...................................................................................................................... 17
9.20 Y-Axis (Serial No -019) ...................................................................................................................... 17
9.21 Y-Axis (Serial No -020) ...................................................................................................................... 18
9.22 Y-Axis (Serial No -021) ...................................................................................................................... 18
9.23 Y-Axis (Serial No -022) ...................................................................................................................... 19
9.24 Y-Axis (Serial No -023) ...................................................................................................................... 19
9.25 Y-Axis (Serial No -024) ...................................................................................................................... 20
9.26 Y-Axis (Serial No -025) ...................................................................................................................... 20
9.27 Y-Axis (Serial No -026) ...................................................................................................................... 21
9.28 Y-Axis (Serial No -027) ...................................................................................................................... 21
9.29 Y-Axis (Serial No -028) ...................................................................................................................... 22
9.30 Y-Axis (Serial No -029) ...................................................................................................................... 22
9.31 Z-Axis (Serial No -015) ...................................................................................................................... 23
9.32 Z-Axis (Serial No -016) ...................................................................................................................... 23
9.33 Z-Axis (Serial No -017) ...................................................................................................................... 24
9.34 Z-Axis (Serial No -018) ...................................................................................................................... 24
9.35 Z-Axis (Serial No -019) ...................................................................................................................... 25
9.36 Z-Axis (Serial No -020) ...................................................................................................................... 25
9.37 Z-Axis (Serial No -021) ...................................................................................................................... 26
9.38 Z-Axis (Serial No -022) ...................................................................................................................... 26
9.39 Z-Axis (Serial No -023) ...................................................................................................................... 27
9.40 Z-Axis (Serial No -024) ...................................................................................................................... 27
9.41 Z-Axis (Serial No -025) ...................................................................................................................... 28
9.42 Z-Axis (Serial No -026) ...................................................................................................................... 28
9.43 Z-Axis (Serial No -027) ...................................................................................................................... 29
9.44 Z-Axis (Serial No -028) ...................................................................................................................... 29
9.45 Z-Axis (Serial No -029) ...................................................................................................................... 30
9.46 After Test Image ............................................................................................................................... 30
10.0 Test Requirements................................................................................................................................ 30
This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 3 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

11.0 Test Results ........................................................................................................................................... 30


12.0 Opinion or Interpretation if any ........................................................................................................... 31
13.0 Details of Decision rule applied if any .................................................................................................. 31
14.0 Distribution ........................................................................................................................................... 31
15.0 Disclaimer ............................................................................................................................................. 31

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 4 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

2.0 Amendment details

Date Amd. No. Details of Change Reason for Amendment Amended by

- 0 - - -
Table 1 - Amendment Details

3.0 Scope of Work


To perform Random Vibration test on “Rugged Panel PC-PPC-04” for M/s. Datasol (B) Private Limited, as per
customer specification.

4.0 General Information

Name and Address of the customer : M/s. Datasol (B) Private Limited
No 793, Datasol Hose, Veeranna Paalya, behind BEL,
Corporate Office, Nagawara, Bengaluru.

Details of customer representative : Mr. Sridhar

Customer Work order Number : NA

DUT Received on : 15th May 2024

Condition of DUT on receipt : Good

Details of DUT : Refer section 6.0

Test Specification : Refer section 8.1

Date of test : 15th May 2024 to 17th May 2024

Test Witnessed by : Mr. Parameswar Reddy

List of Equipment & calibration details : Refer Section 7.0

5.0 Information / Data provided by customer

1. Specification 4. Fixture
2. Requirements 5. Power supply
3. Samples 6. Special Instruction

Special Instruction: NA

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 5 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

6.0 Sample Details

Condition upon
[Link]. Product name Serial Number KB. Serial No Part. No
receipt
68-2023,116-2024,
23-2023,96-2023,
015,016,017,0
73-2023,98-2023,
18,019,020,02
Rugged Panel 143-2024,130-2024,
01 1,022,023,024 XL94141 Good
PC-PPC-04 72-2023,102-2023,
,025,026,027,
137-2024,94-2023,
028,029
86-2023,45-2023,
95-2023
Table 2 - Details of sample

7.0 Details of Equipment and Instruments used

[Link]. Name of the Equipment Equipment / Instrument ID Calibration due on

01 Vibration shaker ITSPL -TE-040 05th Jun 2024


02 Accelerometer ITSPL -TI-126 14th Dec 2024
Table 3 - Details of Equipment and Instruments used

8.0 Test Execution

8.1 Random vibration Test

Test Specification Date of Start Date of End


Frequency(Hz) Acceleration((g)2/Hz)
5 0.00126191
20 0.02
15th May 2024 17th May 2024
50 0.02
500 0.001
Grms - 1.547g
Table 4 – Test Specification

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 6 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

8.2 Before Test Image

Figure 1- Before test image

8.3 Test set up picture

Figure 2-Test setup image Figure 3-Test setup image

Figure 4-Test setup image

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 7 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.0 Test Graph

9.1 X-Axis (Serial No-015)

Graph 1-X Axis Serial No-015

9.2 X-Axis (Serial No-016)

Graph 2 - X Axis Serial No-016

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 8 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.3 X-Axis (Serial No -017)

Serial No:-017
KB. [Link]:- 23-2023

Graph 3- X Axis Serial No-017

9.4 X-Axis (Serial No -018)

Serial No:- 018


KB. Sl. No:- 96-2023
23-2023

Graph 4 X Axis Serial No-018

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 9 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.5 X-Axis (Serial No -019)

Serial No:-019
[Link]:-73-2023

Graph 5- X Axis Serial No-019

9.6 X-Axis (Serial No -020)

Serial No:-020
[Link]:-98-2023

Graph 6- X Axis Serial No-020

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 10 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.7 X-Axis (Serial No -021)

Serial No:-021
[Link]:-143-2024

Graph 7- X Axis Serial No-021

9.8 X-Axis (Serial No -022)

Serial No:-022
[Link]:-130-2024

Graph 8-X Axis Serial No-022

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 11 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.9 X-Axis (Serial No -023)

Serial No:-023
KB. [Link]:-72-2023

Graph 9- X Axis Serial No-023

9.10 X-Axis (Serial No-024)

Serial No:-024
KB. [Link]:-102-2023

Graph 10- X Axis Serial No-024

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 12 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.11 X-Axis (Serial No-025)

Serial No:-025
KB. Sl .No:-137-2024

Graph 11-X Axis Serial No-025

9.12 X-Axis (Serial No-026)

Serial No:-026
KB. Sl .No:-94-2023

Graph 12- X Axis Serial No-026

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 13 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.13 X-Axis (Serial No-027)

Serial No:-027
KB. Sl .No:-86-2023

Graph 13- X Axis Serial No-027

9.14 X-Axis (Serial No-028)

Serial No:-028
KB. Sl .No:-45-2023

Graph 14—X Axis Serial No-028

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 14 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.15 X-Axis (Serial No-029)

Serial No:-029
KB. Sl .No:-95-2023

Graph 15- X Axis Serial No-028

9.16 Y-Axis (Serial No-015)

Serial No:-015
KB. Sl .No:-68-2023

Graph 16- Y-Axis Serial No-015

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 15 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.17 Y-Axis (Serial No-016)

Serial No:-016
[Link] .No:-116-2024

Graph 17- Y-Axis Serial No-016

9.18 Y-Axis ( Serial No -017)

Serial No:-017
[Link] .No:- 23-2023

Graph 18- Y-Axis Serial No-017

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 16 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.19 Y-Axis (Serial No -018)

Serial No:-018
[Link] .No:-96-2023

Graph 19- Y-Axis Serial No-018

9.20 Y-Axis (Serial No -019)

Serial No:-019
[Link] .No:-73-2023

Graph 20- - Y-Axis Serial No-019

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 17 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.21 Y-Axis (Serial No -020)

Serial No:-020
[Link] .No:-98-2023

Graph 21- Y-Axis Serial No-020

9.22 Y-Axis (Serial No -021)

Serial No:-021
[Link] .No:-143-2024

Graph 22- Y-Axis Serial No-021

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 18 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.23 Y-Axis (Serial No -022)

Serial No:-022
[Link] .No:-130-2024

Graph 23- Y-Axis Serial No-022

9.24 Y-Axis (Serial No -023)

Serial No:-023
KB. Sl .No:-72-2023

Graph 24- Y-Axis Serial No-023

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 19 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.25 Y-Axis (Serial No -024)

Serial No:-024
KB. Sl .No:-102-2023

Graph 25- Y-Axis Serial No-024

9.26 Y-Axis (Serial No -025)

Serial No:-025
KB. Sl .No:-137-2024

Graph 26- Y-Axis Serial No-025

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 20 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.27 Y-Axis (Serial No -026)

Serial No:-026
KB. Sl .No:-94-2023

Graph 27- Y-Axis Serial No-026

9.28 Y-Axis (Serial No -027)

Serial No:-027
KB. Sl .No:-86-2023

Graph 28-- Y-Axis Serial No-027

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 21 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.29 Y-Axis (Serial No -028)

Serial No:-028
KB. Sl .No:-45-2023

Graph 29- Y-Axis Serial No-028

9.30 Y-Axis (Serial No -029)

Serial No:-029
KB. Sl .No:-95-2023

Graph 30- Y-Axis Serial No-029

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 22 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.31 Z-Axis (Serial No -015)

Serial No:-015
KB. Sl .No:-68-2023

Graph 31-Z -Axis Serial No-015

9.32 Z-Axis (Serial No -016)

Serial No:-016
[Link] .No:-116-2024

Graph 32- Z-Axis Serial No-016

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 23 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.33 Z-Axis (Serial No -017)

Serial No:-017
[Link] .No:- 23-2023

Graph 33- Z -Axis Serial No-017

9.34 Z-Axis (Serial No -018)

Serial No:-018
KB. Sl. No:-96-2023

Graph 34- Z-Axis Serial No-018

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 24 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.35 Z-Axis (Serial No -019)

Serial No:-019
KB. Sl. No:-73-2023

Graph 35- Z-Axis Serial No-019

9.36 Z-Axis (Serial No -020)

Serial No:-020
KB. Sl. No:-98-2023

Graph 36- Z-Axis Serial No-020

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 25 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.37 Z-Axis (Serial No -021)

Serial No:-021
KB. Sl. No:-143-2024

Graph 37- Z-Axis Serial No-021

9.38 Z-Axis (Serial No -022)

Serial No:-022
KB. Sl. No:-130-2024

Graph 38 Z - Axis Serial No-022

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 26 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.39 Z-Axis (Serial No -023)

Serial No:-023
KB. Sl. No:-72-2023

Graph 39- Z-Axis Serial No-023

9.40 Z-Axis (Serial No -024)

Serial No:-024
KB. Sl. No:-102-2023

Graph 40-- Z-Axis Serial No-024

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 27 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.41 Z-Axis (Serial No -025)

Serial No:-025
KB. Sl. No:-137-2024

Graph 41- Z-Axis Serial No-025

9.42 Z-Axis (Serial No -026)

Serial No:-026
KB. Sl. No:-94-2023

Graph 42- Z-Axis Serial No -026

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 28 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.43 Z-Axis (Serial No -027)

Serial No:-027
KB. Sl. No:-86-2023

Graph 43- Z-Axis Serial No -027

9.44 Z-Axis (Serial No -028)

Serial No:-028
KB. Sl. No:-45-2023

Graph 44- Z-Axis Serial No -028

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 29 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

9.45 Z-Axis (Serial No -029)

Serial No:-029
KB. Sl. No:-95-2023

Graph 45- Z -Axis Serial No -028

9.46 After Test Image

Figure 5- After test image

10.0 Test Requirements

No physical abnormalities allowed.

11.0 Test Results

No physical abnormalities noticed on the sample after test.

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 30 of 31
agreement will lead to legal proceeding’s
M/s. ImpactCalibration and Testing Solutions Private Limited | B5, 2nd Cross, ITI Industrial Estate, Mahadevapura, Bangalore
Karnataka – 560048, India | Email – contact@[Link] | Website – [Link]

Test report No.- ITSPL2425070


Discipline – Electrical Group – Environmental Test facility

12.0 Opinion or Interpretation if any

NA

13.0 Details of Decision rule applied if any

NA

14.0 Distribution

1. Customer

15.0 Disclaimer

NA

Important Note :

1. The tests were conducted as per the standard and specification given by the customer.
2. The results are indicated based on the observation done at various stages of the test by ITSPL Lab.
3. The test results given in this report shall apply only to the samples tested under the specific conditions and methods specified in this report.
other similar equipment or sample may not necessarily reproduce the same result due to variation in the manufacturing process, tolerances,
testing conditions, measurement uncertainties etc.
4. Any measurement uncertainty indicated in this report are for reference purpose only.
5. The report shall not be reproduced or modified in any way unless it is approved by ITSPL Lab in writing by an authorised person.
6. Any change or modification or update required in this report shall be intimated to the lab within 30 days from the date of issue of the report.
Those changes if appropriate will be done at free of cost, any request for the same after 30 days will be considered on chargeable basis.
7. The information given in this report, such as Name of DUT, Part no, supplier, customer [Link] based on the information received from the
customer, ITSPL lab does not take any responsibility for the authenticity of such information.
8. Customers are requested to quote the report reference number for any queries related to this report.
9. We assume customer knows that this is only a test report, not a test certificate.
10. We request the customer to take their tested samples, fixtures and any of their material back within 30 days from the date of completion of
the test. ITSP lab will not take any responsibility of preserving those items thereafter.
11. Customers are requested to witness the test as they wish during any stage or all the stages of test and raise queries or clarifications at that
stage itself if correction is / are required and found appropriate will be done, we will not entertain any quarrels after completion of the test.
12. We use our own standard report formats only, and we do continuous improvement on our report format time to time. However if customer
request a different report format, the same also can be made at an extra cost based on the complexity of work.
13. We will share the final approved test report only on PDF non editable formats with password protected to customer offcial mail id only.
14. The report has confidential information with respect to customer product and ITSPL lab equipment, procedures and methods, we assume
customer will not share this report to any of our competitors in any manner, appropriate legal action will be taken against such behaviour if
found guilty.
***End of the Report***

This is a confidential report contains M/s. Impact Test and Calibration lab proprietary information and their customer product details, this
Date of Issue Amendment No. - 0
report should not be shared in any form to anyone, without written consent from authorized representative of the Lab, any breach of this
18.05.2024 Page 31 of 31
agreement will lead to legal proceeding’s