0% found this document useful (0 votes)
60 views5 pages

6ES71426BR000BB0 Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views5 pages

6ES71426BR000BB0 Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Data sheet 6ES7142-6BR00-0BB0

SIMATIC ET 200eco PN, DQ 8x 24 V DC/2A, M12-L, 8x M12, single and double


assignment, source output (PNP,switching to P potential), substitute value output,
channel diagnostics for wire break and short-circuit at the output, shared device
with 2 controllers, 0.25 ms isochronous mode, prioritized startup, MSO, MRP, S2
redundancy, I&M0...3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of
protection IP67 / IP69K

General information
HW functional status FS06
Firmware version V5.1.x
● FW update possible Yes
Vendor identification (VendorID) 002AH
Device identifier (DeviceID) 0306H
Manufacturer ID according to ODVA (VendorID) 04E3H
Device ID according to ODVA (Product code) 0FA7H
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes
● Prioritized startup Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version STEP 7 V17 or higher with HSP 0363
● PROFINET from GSD version/GSD revision GSDML V2.3.x
● Multi Fieldbus Configuration Tool (MFCT) from V1.3 SP1
Operating mode
● DQ Yes
● MSO Yes
Supply voltage
power supply according to NEC Class 2 required No
Load voltage 1L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
● Reverse polarity protection Yes
Load voltage 2L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
● Reverse polarity protection Yes; against destruction
Input current
Current consumption (rated value) 65 mA; without load
from load voltage 1L+ (unswitched voltage) 12 A; Maximum value
from load voltage 2L+, max. 12 A; Maximum value
Power loss
Power loss, typ. 8.2 W
Address area
Address space per module
● Inputs 1 byte for QI information

6ES71426BR000BB0 Subject to change without notice


2/21/2025
Page 1/5 © Copyright Siemens
● Outputs 1 byte
Hardware configuration
Submodules
● Number of configurable submodules, max. 2
Digital outputs
Number of digital outputs 8
Current-sourcing Yes
output characteristic acc. to IEC 61131, type 2 Yes
Short-circuit protection Yes; per channel, electronic
● Response threshold, typ. 4A
Limitation of inductive shutdown voltage to Type -14 V
Controlling a digital input Yes
Switching capacity of the outputs
● with resistive load, max. 2A
● with inductive load, max. 2A
● on lamp load, max. 10 W
Load resistance range
● lower limit 12 Ω
● upper limit 4 kΩ
Output voltage
● for signal "1", min. 2L+ (-0,8 V)
Output current
● for signal "1" rated value 2A
● for signal "1" permissible range, max. 2A
● for signal "0" residual current, max. 0.2 mA
Output delay with resistive load
● "0" to "1", max. 50 µs; at rated load
● "1" to "0", max. 100 µs; at rated load
Parallel switching of two outputs
● for uprating No
● for redundant control of a load Yes
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.5 Hz
● on lamp load, max. 1 Hz
Total current of the outputs
● Current per module, max. 8A
Cable length
● unshielded, max. 30 m
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface type PROFINET with 100 Mbit/s full duplex (100BASE-TX)
Interface types
● M12 port Yes; 2x M12, 4-pin, D-coded
● Number of ports 2
● integrated switch Yes
Protocols
● PROFINET IO Device Yes
● Open IE communication Yes
Interface types
M12 port
● Autonegotiation Yes
● Autocrossing Yes
● Transmission rate, max. 100 Mbit/s
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
EtherNet/IP Yes
Modbus TCP Yes

6ES71426BR000BB0 Subject to change without notice


2/21/2025
Page 2/5 © Copyright Siemens
PROFINET IO Device
Services
— IRT Yes; 250 µs to 4 ms in 125 µs frame
— Prioritized startup Yes
— Shared device Yes
— Number of IO Controllers with shared device, max. 2
Redundancy mode
● PROFINET system redundancy (S2) Yes
— on S7-1500R/H Yes
— on S7-400H Yes
● PROFINET system redundancy (R1) No
● H-Sync forwarding Yes
Media redundancy
— MRP Yes
EtherNet/IP
Services
— CIP Implicit Messaging Yes
— CIP Explicit Messaging Yes
— CIP Safety No
— Shared device Yes; 2x EtherNet/IP Scanner
— Number of scanners with shared device, max. 2
Updating times
— Requested Packet Interval (RPI) 2 ms
Redundancy mode
— DLR (Device Level Ring) No
Address area
— Address space per module, max. 20 byte
— LargeForwardOpen (Class3) No
Modbus TCP
Services
— read coils (code=1) Yes
— read discrete inputs (code=2) Yes
— Read Holding Registers (Code=3) Yes
— write single coil (code=5) Yes
— write multiple coils (code=15) Yes
— Write Multiple Registers (Code=16) Yes
— Parameter change by master No
— Modbus TCP Security Protocol No
Address space per station
— Address space per station, max. 20 byte
— Access-consistent address space 2 byte
Updating time
— I/O request interval 2 ms
Connections
— number of connections per device 12
Open IE communication
● TCP/IP Yes; (only EtherNet/IP or Modbus TCP)
● SNMP Yes
● LLDP Yes
● ARP Yes
Isochronous mode
Equidistance Yes
shortest clock pulse 250 µs
max. cycle 4 ms
Jitter, max. 10 µs
Interrupts/diagnostics/status information
Substitute values connectable Yes
Alarms
● Diagnostic alarm Yes; Parameterizable
● Maintenance interrupt Yes; Parameterizable
Diagnoses

6ES71426BR000BB0 Subject to change without notice


2/21/2025
Page 3/5 © Copyright Siemens
● Diagnostic information readable Yes
● Monitoring the supply voltage Yes
— parameterizable Yes
● Wire-break Yes
● Short-circuit Yes; Outputs to M; channel by channel
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● MAINT LED Yes; Yellow LED
● NS LED Yes; green/red LED
● MS LED Yes; green/red LED
● IO LED Yes; red/green/yellow LEDs
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● For load voltage monitoring Yes; green LED
● Connection display LINK TX/RX Yes; green LED, only link
Potential separation
between the load voltages Yes
between Ethernet and electronics Yes
Potential separation channels
● between the channels No
● between the channels and the power supply of the Yes
electronics
Isolation
tested with
● 24 V DC circuits 707 V DC (type test)
● Test voltage for interface, rms value [Vrms] 1 500 V; According to IEEE 802.3
Degree and class of protection
IP degree of protection IP65/67/69K
Standards, approvals, certificates
Suitable for safety-related tripping of standard modules Yes; From FS02
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 63 kg
— global warming potential, (during production) [CO2 12.7 kg
eq]
— global warming potential, (during operation) [CO2 52.8 kg
eq]
— global warming potential, (after end of life cycle) -2.65 kg
[CO2 eq]
Highest safety class achievable for safety-related tripping of standard modules
● Performance level according to ISO 13849-1 PL d
● Category according to ISO 13849-1 Cat. 3
● SIL acc. to IEC 62061 SIL 2
● remark on safety-oriented shutdown https://support.industry.siemens.com/cs/de/en/view/39198632
Use in hazardous areas
● Explosion protection category for gas ATEX, UKEX, IECEx, CCCEx for Zone 2
● Explosion protection category for dust ATEX, UKEX, IECEx, CCCEx for Zone 22
product functions / security / header
signed firmware update Yes
safely removing data Yes
Ambient conditions
Ambient temperature during operation
● min. -40 °C
● max. 60 °C
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressure-altitude Up to max. 5 000 m, at installation height > 2 000 m additional restrictions
connection method
Design of electrical connection 4/5-pin M12 circular connectors
Design of electrical connection for the inputs and outputs M12, 5-pin, A-coded

6ES71426BR000BB0 Subject to change without notice


2/21/2025
Page 4/5 © Copyright Siemens
Design of electrical connection for supply voltage M12, 4-pin, L-coded
Dimensions
Width 45 mm
Height 200 mm
Depth 48 mm
Weights
Weight, approx. 780 g
Classifications
Version Classification

eClass 14 27-24-26-04
eClass 12 27-24-26-04
eClass 9.1 27-24-26-04
eClass 9 27-24-26-04
eClass 8 27-24-26-04
eClass 7.1 27-24-26-04
eClass 6 27-24-26-04
ETIM 9 EC001599
ETIM 8 EC001599
ETIM 7 EC001599
IDEA 4 3566
UNSPSC 15 32-15-17-05

Approvals / Certificates
For use in hazard-
General Product Approval
ous locations

Manufacturer Declara- CCC-Ex


tion

For use in hazardous locations Marine / Shipping

Miscellaneous

Food, Pharmaceut-
Marine / Shipping
ical, Medical

NK / Nippon Kaiji Ky- CCS (China Classifica- Confirmation


okai tion Society)

Environment Industrial Communication

PROFINET

last modified: 11/22/2024

6ES71426BR000BB0 Subject to change without notice


2/21/2025
Page 5/5 © Copyright Siemens

You might also like