Altivar Process ATV900/ATV600
Presented by:
Mario Prayogo – Sr. Product Application Engineer
Internal
Important link/source
Catalog Motor Management :
[Link]
[Link]
automation-control/tools/[Link]
Installation manual
[Link] [Link]
Programming Manual [Link]/design
[Link]
FAQ
[Link]
Somove:
[Link]
Youtube
[Link]
TCSMCNAM3M002P
Confidential Property of Schneider Electric | Page 2
Internal
YouTube Playlists - How to videos (Worldwide)
How to: Altivar Soft Starters How to: Altivar Machine ATV320
25 videos 25 videos
[Link] [Link]
ist?list=PLa7UGrWOTyjmo ylist?list=PLa7UGrWOTyj
XYQk91jbn01VFDXnPakF kmuiHyakGthhIvucpha0lY
How to: Altivar Process How to: Altivar Machine ATV340
ATV600/ATV900
52 videos 19 videos
[Link]
[Link] st=PLa7UGrWOTyjkbYmZ2g
vxG0W6Rjlsg_JY-
GrWOTyjmbTYNYk6M6UbPAp1iMsDB
How to: Altivar 25 videos
Building ATV212 [Link]
7UGrWOTyjk6JlnvZOCvHb14iYjVLhHI
Internal
Altivar Process – ATV 660
Schneider Electric - Drives- January 2014 4
General
Altivar Process Modules (APM) Standard module
ATV6A0 / ATV9A0 „Standard“ Solution with diode/thyristor rectifier
400V
690V
Confidential Property of Schneider Electric | Page 5
Internal
Technical Specifications
Control Terminals ATV6xx
● 6 Digital Inputs
● 2 Safe Torque Off (Power removal) Input
● 3 Analogue Inputs
● 3 Relays
● 2 Analogue Outputs
● 1 switch for configuration (Sink/Source)
● 3 RJ 45 connector for communication
● 1 colour per IO group
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 6
General
Technical Specifications
The Control Inputs / Outputs ATV6xx / ATV9xx
● Internal sources
● Protected against short circuit
● + 24VDC (21VDC to 27VDC) – 200mA
To supply STO
● + 24VDC (21VDC to 27VDC) – 200mA
To supply the logic inputs
● + 10VDC (0 / +5%) – 10mA
● External power supply (P24)
● To supply also eventually the logic inputs
and STO
● Protected against over voltage
● + 24VDC (19VDC to 30VDC) – 1,25A max.
● In compliance with IEC 65A-68 standard
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 7
General
Technical Specifications
The Digital Inputs ATV6xx
● 6 Digital inputs DI1, DI2, DI3, DI4, DI5, DI6
● Supply + 24VDC (max. 30V)
● Internal impedance : 3,5 kΩ
● Response Time : 10ms (± 2 ms)
● Compatible with level 1 PLC,
IEC 65A-68 standard
● Source, Sink or Ext configuration
by switch SW1
● Multi assignment still available
● DI5 and DI6 can be used as pulse train : 30 kHz Sink
Int
SW1 Ext
Source
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 8
General
IP Rating and air flow for IP21
Common air flow for Power & Control
• Air inlet via the front door (without filter)
Roof-top fan
Air Outlet • Common air flow for Power & Control
• One air path leads through the power
module, driven by the internal fan,
the other is for the electronic
components
• Both airways come together in the upper
Power Module fan
part of the cabinet and are blown out
together with the external fan through the
roof top extension
Air inlet via the
front door
Confidential Property of Schneider Electric | Page 9
Internal
Base Product Architecture
Air flow management
IP23 IP54
Filter
pads
10%
(filtered)
100%
90%
Confidential Property of Schneider Electric | Page 10
Wiring
Confidential Property of Schneider Electric | Page 11
Internal
Wiring
Confidential Property of Schneider Electric | Page 12
Internal
Wiring
Confidential Property of Schneider Electric | Page 13
Internal
Wiring
Confidential Property of Schneider Electric | Page 14
Internal
Wiring
Confidential Property of Schneider Electric | Page 15
Internal
Wiring
Confidential Property of Schneider Electric | Page 16
Internal
Drive Status
Setting Code / Value Description
[Auto-tuning] tUn Autotuning
[In DC inject.] dCb Injection braking
[Ready] rdY Drive ready
[Freewheel] nSt Freewheel stop control
[Running] rUn Motor in steady state or run command present and zero reference
[Accelerating] ACC Acceleration
[Decelerating] dEC Deceleration
[Current limitation] CLI Current limit
[Fast stop] FSt Fast stop
[Mot. fluxing] FLU Fluxing function is activated
[No Mains Voltage] nLP Control is powered on but the DC bus is not loaded
[STO Active] PrA Power removal function has been activated
[[Link]] CtL Controlled stop
[Dec. adapt.] Obr Adapted deceleration
[Output cut] SOC Stand by output cut
[Undervoltage Warning] USA Undervoltage warning
[TC Mode Active] tC TC indus mode activated
[In autotest] St Self test in progress
[Autotest error] FA Self test detected error
[Autotest OK] YES Self test OK
[EEprom test] EP Self test EEPROM detected error
[“Operating State "Fault“] FLt Product has detected error
[DCP Flashing Mode] dCP DCP flashing mode
[STO Active] StO Safety function STO level
[Energy Saving] IdLE Idle stop and go mode
--F Fault (see the manual for details on fault codes)
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
17
Simply Start
● [Link]
● [Link]
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
18
Motor Nameplate
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
19
THANK YOU
Confidential Property of Schneider Electric | Page 20
Internal
Internal