OPERATING INSTRUCTION FOR
SNR BASIC
PROBING ROUTINES
TASK COMMAND DESCRIPTION
CALIBRATE G54 .SET Z WORK COORDINATE ON SURFACE
PROBE LENGTH .M100C1.Z-10 POSITION THE PROBE 10 MM ABOVE THE
.SURFACE, EXECUTE THE COMMAND
CALIBRATE PROBE M100C1.D45.006 FIND THE CENTER OF THE MASTER RING
OFFSET AND WITH INDICATOR. PLACE THE PROBE IN
EFFECTIVE RADIUS THE CENTER OF THE RING. EXECUTE THE
.COMMAND
M100C200.D45.006 NO EXACT CENTER OF THE MASTER RING
MUST BE FOUND. PLACE THE PROBE
ROUGHLY IN THE CENTER OF THE RING.
EXECUTE THE COMMAND. WHEN ASKED,
RELEASE THE TOOL AND CLAMP AGAIN
ROTATED 180 DEGREES. PROCEED WITH
.THE EXECUTION OF THE COMMAND
MEASURE SURFACE M100X-10.(S54)(I4.) PLACE THE PROBE 10 MM FROM THE
SET WORK M100Y10.(S101)(J-5.) .SURFACE
COORDINATE SYSTEM M100Z-10.(S59)(K4.) EXECUTE THE COMMAND. I, J, K – SHIFT
AMOUNT OF X,Y,Z WORK SYSTEM
MEASURE BORE 4 M100D45.(S54)(I5.)(J4.) PLACE THE PROBE ROUGHLY IN THE
.POINTS CENTER OF THE BORE. EXECUTE THE
SET WORK COMMAND. I, J – SHIFT AMOUNT OF X,Y
COORDINATE SYSTEM .WORK SYSTEM
MEASURE BOSS 4 M100D45.Z-15.(S54)(I5.)(J4.) PLACE THE PROBE ROUGHLY IN THE
.POINTS CENTER ABOVE THE BOSS. Z -
SET WORK INCREMENTAL DISTANCE FROM
COORDINATE SYSTEM STARTING Z POSITION TO THE TOUCH
HEIGHT. EXECUTE THE COMMAND. I, J –
SHIFT AMOUNT OF X,Y WORK SYSTEM
.MEASURE SLOT IN X M100D38.X1.(S55)(I3.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE .OF THE SLOT. EXECUTE THE COMMAND
SYSTEM IN THE I – SHIFT AMOUNT OF X COORDINATE
CENTER SYSTEM
.MEASURE SLOT IN Y M100D38.Y1.(S57)(J4.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE .OF THE SLOT. EXECUTE THE COMMAND
SYSTEM IN THE J – SHIFT AMOUNT OF Y COORDINATE
CENTER .SYSTEM
.MEASURE WEB IN X M100D52.X1.Z-20.(S123)(I5.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE OF THE SLOT. Z - INCREMENTAL
SYSTEM IN THE DISTANCE FROM STARTING Z POSITION
CENTER TO THE TOUCH [Link] THE
COMMAND. I – SHIFT AMOUNT OF X
.COORDINATE SYSTEM
.MEASURE WEB IN Y M100D52.Y1.Z-20.(S123)(J5.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE OF THE WEB. Z - INCREMENTAL
SYSTEM IN THE DISTANCE FROM STARTING Z POSITION
CENTER TO THE TOUCH [Link] THE
COMMAND. J – SHIFT AMOUNT OF Y
.COORDINATE SYSTEM
MEASURE ANGLE .M100Y-10
.M100A0Y-10
PROTECTED MOVE M100B1.X100.Y100.Z20.(F2500)
INPUTS:
SURFACE
Xx – APPROXIMATE DISTANCE AND DIRECTION TO X SURFACE
Yy – APPROXIMATE DISTANCE AND DIRECTION TO Y SURFACE
Zz – APPROXIMATE DISTANCE AND DIRECTION TO Z SURFACE
Qq- OVERTRAVEL. DEFAULT SPECIFIED IN #113 IN O9960
FEATURE
Dd – NOMINAL DIMENSION OF MEASURED FEATURE
X1. – MARKER - THE SLOT/WEB TO BE MEASURED IN X DIRECTION
Y1. – MARKER - THE SLOT/WEB TO BE MEASURED IN Y DIRECTION
Rr – RADIAL DISTANCE BETWEEN THE PROBE AND SIDE OF THE [Link] SPECIFIED IN #114 IN
O9960
Aa – REFERENCE ANGLE IN ANGLE ROUTINE
CALIBRATION
C1. – MARKER – CALIBRATION ROUTINE
Cc – (c>1.) MARKER AND AMOUNT OF Z RISE FOR ROTATION OF THE PROBE IN "CENTERLESS" ROUTINE
GENERAL
Ss – WORK COORDINATE SYSTEM TO BE SET (S54-S59, S101-S148)
Ii - SHIFT OF MESURED WORK CORDINATE SYSTEM IN X
Jj - SHIFT OF MESURED WORK CORDINATE SYSTEM IN Y
Kk - SHIFT OF MESURED WORK CORDINATE SYSTEM IN Z
OUTPUTS:
#135 – X MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#136 – Y MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#137 – Z MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#138 – FEATURE'S MEASURED SIZE
#144 – ANGLE RELATIVE TO REFERENCE Aa
PROGRAM O9022 ASSIGNED IN PARAMETER 6082 TO M100.