0% found this document useful (0 votes)
16 views2 pages

Operating Instruction For F

The document provides operating instructions for SNR Basic probing routines, detailing various commands for calibrating and measuring work coordinate systems. It includes specific commands for tasks such as calibrating the probe, measuring surfaces, and setting work coordinates with associated parameters. Additionally, it outlines input and output specifications for the probing process, ensuring accurate measurements and adjustments during operation.

Uploaded by

Dave Kerr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views2 pages

Operating Instruction For F

The document provides operating instructions for SNR Basic probing routines, detailing various commands for calibrating and measuring work coordinate systems. It includes specific commands for tasks such as calibrating the probe, measuring surfaces, and setting work coordinates with associated parameters. Additionally, it outlines input and output specifications for the probing process, ensuring accurate measurements and adjustments during operation.

Uploaded by

Dave Kerr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd

OPERATING INSTRUCTION FOR

SNR BASIC
PROBING ROUTINES

TASK COMMAND DESCRIPTION


CALIBRATE G54 .SET Z WORK COORDINATE ON SURFACE
PROBE LENGTH .M100C1.Z-10 POSITION THE PROBE 10 MM ABOVE THE
.SURFACE, EXECUTE THE COMMAND
CALIBRATE PROBE M100C1.D45.006 FIND THE CENTER OF THE MASTER RING
OFFSET AND WITH INDICATOR. PLACE THE PROBE IN
EFFECTIVE RADIUS THE CENTER OF THE RING. EXECUTE THE
.COMMAND

M100C200.D45.006 NO EXACT CENTER OF THE MASTER RING


MUST BE FOUND. PLACE THE PROBE
ROUGHLY IN THE CENTER OF THE RING.
EXECUTE THE COMMAND. WHEN ASKED,
RELEASE THE TOOL AND CLAMP AGAIN
ROTATED 180 DEGREES. PROCEED WITH
.THE EXECUTION OF THE COMMAND
MEASURE SURFACE M100X-10.(S54)(I4.) PLACE THE PROBE 10 MM FROM THE
SET WORK M100Y10.(S101)(J-5.) .SURFACE
COORDINATE SYSTEM M100Z-10.(S59)(K4.) EXECUTE THE COMMAND. I, J, K – SHIFT
AMOUNT OF X,Y,Z WORK SYSTEM
MEASURE BORE 4 M100D45.(S54)(I5.)(J4.) PLACE THE PROBE ROUGHLY IN THE
.POINTS CENTER OF THE BORE. EXECUTE THE
SET WORK COMMAND. I, J – SHIFT AMOUNT OF X,Y
COORDINATE SYSTEM .WORK SYSTEM
MEASURE BOSS 4 M100D45.Z-15.(S54)(I5.)(J4.) PLACE THE PROBE ROUGHLY IN THE
.POINTS CENTER ABOVE THE BOSS. Z -
SET WORK INCREMENTAL DISTANCE FROM
COORDINATE SYSTEM STARTING Z POSITION TO THE TOUCH
HEIGHT. EXECUTE THE COMMAND. I, J –
SHIFT AMOUNT OF X,Y WORK SYSTEM
.MEASURE SLOT IN X M100D38.X1.(S55)(I3.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE .OF THE SLOT. EXECUTE THE COMMAND
SYSTEM IN THE I – SHIFT AMOUNT OF X COORDINATE
CENTER SYSTEM
.MEASURE SLOT IN Y M100D38.Y1.(S57)(J4.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE .OF THE SLOT. EXECUTE THE COMMAND
SYSTEM IN THE J – SHIFT AMOUNT OF Y COORDINATE
CENTER .SYSTEM
.MEASURE WEB IN X M100D52.X1.Z-20.(S123)(I5.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE OF THE SLOT. Z - INCREMENTAL
SYSTEM IN THE DISTANCE FROM STARTING Z POSITION
CENTER TO THE TOUCH [Link] THE
COMMAND. I – SHIFT AMOUNT OF X
.COORDINATE SYSTEM
.MEASURE WEB IN Y M100D52.Y1.Z-20.(S123)(J5.) PLACE PROBE ROUGHLY IN THE CENTER
SET WORK CORDINATE OF THE WEB. Z - INCREMENTAL
SYSTEM IN THE DISTANCE FROM STARTING Z POSITION
CENTER TO THE TOUCH [Link] THE
COMMAND. J – SHIFT AMOUNT OF Y
.COORDINATE SYSTEM
MEASURE ANGLE .M100Y-10
.M100A0Y-10
PROTECTED MOVE M100B1.X100.Y100.Z20.(F2500)

INPUTS:
SURFACE
Xx – APPROXIMATE DISTANCE AND DIRECTION TO X SURFACE
Yy – APPROXIMATE DISTANCE AND DIRECTION TO Y SURFACE
Zz – APPROXIMATE DISTANCE AND DIRECTION TO Z SURFACE
Qq- OVERTRAVEL. DEFAULT SPECIFIED IN #113 IN O9960

FEATURE
Dd – NOMINAL DIMENSION OF MEASURED FEATURE
X1. – MARKER - THE SLOT/WEB TO BE MEASURED IN X DIRECTION
Y1. – MARKER - THE SLOT/WEB TO BE MEASURED IN Y DIRECTION
Rr – RADIAL DISTANCE BETWEEN THE PROBE AND SIDE OF THE [Link] SPECIFIED IN #114 IN
O9960
Aa – REFERENCE ANGLE IN ANGLE ROUTINE

CALIBRATION
C1. – MARKER – CALIBRATION ROUTINE
Cc – (c>1.) MARKER AND AMOUNT OF Z RISE FOR ROTATION OF THE PROBE IN "CENTERLESS" ROUTINE

GENERAL
Ss – WORK COORDINATE SYSTEM TO BE SET (S54-S59, S101-S148)
Ii - SHIFT OF MESURED WORK CORDINATE SYSTEM IN X
Jj - SHIFT OF MESURED WORK CORDINATE SYSTEM IN Y
Kk - SHIFT OF MESURED WORK CORDINATE SYSTEM IN Z

OUTPUTS:
#135 – X MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#136 – Y MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#137 – Z MEASURED POSITION IN CURRENT COORDINATE SYSTEM
#138 – FEATURE'S MEASURED SIZE
#144 – ANGLE RELATIVE TO REFERENCE Aa

PROGRAM O9022 ASSIGNED IN PARAMETER 6082 TO M100.