BP030

The document outlines specifications for windows in a townhouse project, including dimensions, types, and energy efficiency requirements. It emphasizes the need for compliance with Australian standards and verification of dimensions on-site by the contractor. Additionally, it includes notes on construction materials and methods to be used, particularly regarding thermal insulation and protection of openings.

Uploaded by

ekhier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

BP030

The document outlines specifications for windows in a townhouse project, including dimensions, types, and energy efficiency requirements. It emphasizes the need for compliance with Australian standards and verification of dimensions on-site by the contractor. Additionally, it includes notes on construction materials and methods to be used, particularly regarding thermal insulation and protection of openings.

Uploaded by

ekhier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1000 550 4450

L1 FL L1 FL L1 FL L1 FL LEGEND
59.850 59.850 59.850 59.850 900 EQ EQ FG - FIXED GLAZING
OS- OPENABLE SASH
GR CL GR CL GR CL GR CL OR 600 FOR 3100 WINDOWS AS- AWNING SASH
DH- DOUBLE HUNG
59.450 59.450 59.450 59.450 OB- OBSCURE GLAZING
SL- SLIDING
L.- OPENABLE LOUVRES
SP SPANDREL PANEL
ALL WINDOWS TO BE POWDERCOATED
GL-02 ALUMINIUM FRAMING UNLESS OTHERWISE

1700
NOTED.
GENERAL NOTES

2200
HOOD/ SCREEN GL-01 ALL GROUND LINES & LEVELS ARE TO BE
IN FRONT OF
VERIFIED ON SITE BY BUILDER.
2700

2700
WINDOWS AS
GL-02
DESIGNED. AS GL-02 400mm CLEARANCE TO UNDERSIDE OF
REFER TO GL-02 GL-01 BEARER IN ACCORDANCE WITH AS-3660.1
ELEVATIONS
TERMITE MANAGEMENT.
FG EAVES TO BE CONSTRUCTED OF NON-
GL-02

1000
COMBUSTIBLE MATERIAL WHERE WITHIN
900mm OF THE BOUNDARY

500
FG FG FG FG SL ENERGY EFFICIENCY NOTES
GR FL GR FL GR FL GR FL DRAWINGS TO BE READ INCONJUNCTION WITH
56.750 56.750 INTERNAL WINDOW 56.750 56.750 ANY RELEVANT ENERGY RATING REPORT

TYPE A TYPE B TYPE C TYPE D NEW CONSTRUCTION:


Refer to the minimum requirements:
- GROUND FLOOR R2.25 ADDED THERMAL
1 : 50 1 : 50 1 : 50 1 : 50 INSULATION
2250
EQ EQ 890 EQ EQ - WALLS R2.8 ADDED THERMAL
INSULATION PLUS SISALATION
L1 FL L1 FL L1 FL - CEILING MINIMUM R5.1 ADDED
59.850 59.850 59.850 THERMAL INSULATION PLUS SARKING
- DOOR SEALS BRUSH SEALS TO UTILITY
GR CL GR CL GR CL ROOM DOORS. SILL SEALS TO
EXTERNAL HINGED DOORS.
59.450 59.450 59.450 - DRAFT EXCLUSION WEATHER SEAL
WITH TAPED HORIZONTAL AND

800
GL-02 VERTICAL JOINTS. SEALED GAPS
AROUND WINDOWS AND EXTERNAL
WINDOW HOOD - FG DOORS.
GL-02

1500
400MM DEPTH, TO MT-01 GL-02 - EXHAUST FANS DRAFT PREVENTION
MATCH WINDOW
FRAME FINISH NOTE:
WINDOW CONFIGURATION AND DIMENSIONS TO BE
CONFIRMED BETWEEN CLIENT AND THE
GL-02 GL-02 SP FG FG
2700

MANUFACTURER PRIOR TO THE COMMENCEMENT


OF WORKS.
4.11

1900
GENERAL NOTE:

1200
UNPROTECTED OPENINGS TO BE
PROTECTED IN ACCORDANCE WITH THE
FG SL
GR FL GR FL GR FL FER. PLEASE ENSURE CONSTRUCTION
56.750 56.750 56.750 REQUIREMENTS ARE INCORPORATED
TYPE E TYPE F TYPE G INTO DOOR/WINDOW SCHEDULE
1 : 50 1 : 50 1 : 50
ACCORDINGLY. INCLUDING ANY WING
900 2090 900
EQ EQ
WALLS THAT MAY BE REQUIRED.
L1 FL L1 FL
L2 FL L2 FL L2 FL
59.850 59.850
62.850 62.850 62.850
GR CL GR CL
L1 CL L1 CL L1 CL
59.450 59.450
62.450 62.450 62.450

650
GL-01

1200
HOOD/ SCREEN IN FRONT
1700

WINDOW HOOD -

1700
OF WINDOWS AS
400MM DEPTH, TO GL-01 GL-01 DESIGNED.
2200

GL-01

800
MATCH WINDOW REFER TO ELEVATIONS
FRAME FINISH GL-01
2700

AS AS
GL-01 GL-01 AS

500
FG FG

AS FG

1000
GL-01 GL-01
1000

900

900
FG
500

FG FG
GR FL GR FL L1 FL L1 FL L1 FL

150
56.750 56.750 59.850 59.850 59.850
TYPE H TYPE I TYPE J TYPE K TYPE L
1 : 50 1 : 50 1 : 50 1 : 50 1 : 50
Rev No. Description Date
Schedule - Windows

4/04/2025 3:06:39 PM
RUIYI AUSTRALIA 1 Prelim Building Permit 19/07/2024
2 Issue for Building Permit 25/07/2024
TOWNHOUSES
BP030
3 Issue for Building Permit 02/04/2025 Project number 23146
Date June 2024
200 SYDNEY ROAD
COBURG, VIC Drawn by EK Revision number BP3
PRELIMINARY BUILDING PERMIT Checked by JD Scale As indicated @A3
This document is copyright and cannot be copied, altered, or reproduced without a written consent of Drake Design. All works to be in accordance with the current NCC and all relative Australian standards.
Contractor must verify all dimensions and levels on site prior to commencement of any works or shop drawings.