IMPACT 4.07.
174 21/03/2024
Printed by:Myint Htun
Service
Chassis ID Path
2841/Diagnostics//MID 128 SID 39 Starter motor output
Model Identity
B11R 136747691
Publish date ID/Operation
19/03/2016
Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
1/3
IMPACT 4.07.174 21/03/2024
MID 128 SID 39 Starter motor output
Component number: A14
General fault symptom: Fault code
Adapter at control unit: 9990014
Other: 9998699, 88890074
Type Failure Description: Possible cause: Proposed
of action:
fault:
FMI 0
White information lamp Engine difficult to start
Cold ambient temperature
Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
2/3
IMPACT 4.07.174 21/03/2024
The starter motor cannot be activated for a Battery voltage low No
certain length of time. Starter motor overheated information
The starter motor is deactivated due to overheat available
FMI 3
Yellow warning lamp Wiring harness between the engine Check relay
The starter motor does not rotate electronic control unit and the starter motor Check
relay wiring
Starter motor relay harness
FMI 5
Yellow warning lamp Starter motor relay Check relay
The starter motor does not rotate Wiring harness between the engine Check
electronic control unit and the starter motor wiring
relay harness
Wiring between the starter relay in the
electrical centre and the starter motor relay
Engine Electronic Control Unit (EECU)
FMI 7
The starter motor is deactivated due to that The starter motor is deactivated No
gear box is not in neutral information
available
FMI
10 The starter motor is deactivated due to that the No information available No
cogwheels of the starter and engine are stuck information
available
FMI
14 The starter motor is deactivated due to that the PTO activated when the starter motor is No
PTO switch is active. activated information
available
Note: If starting fails, hold the starter key in the start position for at least 5 seconds to see if the engine control unit sets
a fault code. When this occurs fault tracing can be carried out based on the set fault code.
Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.
3/3