LAKSHMI RING TRAVELLERS (COIMBATORE) PRIVATE LIMITED
FOUNDRY DIVISION
MAGNETIC PARTICLE INSPECTION REPORT
: LAKSHMI RING TRAVELLERS (COIMBATORE) PRIVATE Report No : LRT/AF/MPI/032/24-25
Customer LIMITED - UNIT-II
ARFLU INDUSTRIAL VALVES Date/ Page No: : 19-07-2024 Page:1 of 1
STO No : 9300003037 Date: 23.05.2024 Magnetizing Current : HWDC
Arflu P.O No. : PC20240397-PV20240054 REV 1 Magnetic Powder : Magnaflux-9C RED Batch No: 23F1043 Mfd-JUN-23
Material : ASTM A216 [Link] Water Conditioner : Magnaflux-WA2B Batch No: 23C35 Mfd-MAY-23
Procedure Reference : ASTM E709 / DIN EN1369 De-Magnetisation : NA
: ASME B16.34 APP-II / AD2000
Acceptance Standard Prod Space (Inches) : 4 - 6''
Table-1
Stage of Test : After heat treatment Current (Ampere) : 450 - 500 Amps
Surface Condition : Pre-Machined stage / After SR Method of Testing : Wet Prod Non-fluorescent
: All Exterior &v Accessible Interior
Extent of Examination Magnetization Field : Circular
Surfaces
Equipment : Magnaflux-P2000 Back Ground Contrast : Grey
Amperage/ Amp
Equipment Calibration Date : 04-03-2024 : NA
Turns Used
Equipment Calibration Due Date : 03-09-2024 Inspection Qty : 01 No
: LX-101A & LUTRON [Link]-
Light Meter Accepted Qty : 01 No
Q872466
Light Intesity : 1100 To 1300 lx Rejected Qty :-
Equipment Calibration Date : 22-03-2024 Date of Test : 19-07-2024
Equipment Calibration Due Date : 21-09-2024
S. No. Item Description Drawing & Rev No. / Part No Heat No MPI No Result
1 20''-150 BODY DP-013434 Rev.1 33225 MP6159T Acceptable
Remark : No Recordable Indications
For LRT Foundry Division Inspected For LRT Foundry Division Approved
Customer
By By
Name: [Link] Name: [Link] Name:
Date: 19-07-2024 Date: 19-07-2024 Date :
Signature : Signature : Signature :
SNT-TC-1A SNT-TC-1A
NDT Level-II MPIDP NDT Level-II MPIDPRTVT
F/QA-14, R01