0% found this document useful (0 votes)
36 views1 page

Lakshmi Ring Travellers (Coimbatore) Private Limited Foundry Division Magnetic Particle Inspection Report

The Magnetic Particle Inspection Report for Lakshmi Ring Travellers (Coimbatore) Private Limited details the inspection of a 20''-150 body made from ASTM A216 Gr.WCB, which was tested after heat treatment on July 19, 2024. The inspection used Magnaflux-9C RED magnetic powder and confirmed that the item is acceptable with no recordable indications. The report includes calibration details for the equipment used and confirms that the inspection was performed in accordance with ASTM E709 and other relevant standards.

Uploaded by

U2 QC
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views1 page

Lakshmi Ring Travellers (Coimbatore) Private Limited Foundry Division Magnetic Particle Inspection Report

The Magnetic Particle Inspection Report for Lakshmi Ring Travellers (Coimbatore) Private Limited details the inspection of a 20''-150 body made from ASTM A216 Gr.WCB, which was tested after heat treatment on July 19, 2024. The inspection used Magnaflux-9C RED magnetic powder and confirmed that the item is acceptable with no recordable indications. The report includes calibration details for the equipment used and confirms that the inspection was performed in accordance with ASTM E709 and other relevant standards.

Uploaded by

U2 QC
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

LAKSHMI RING TRAVELLERS (COIMBATORE) PRIVATE LIMITED

FOUNDRY DIVISION
MAGNETIC PARTICLE INSPECTION REPORT
: LAKSHMI RING TRAVELLERS (COIMBATORE) PRIVATE Report No : LRT/AF/MPI/032/24-25
Customer LIMITED - UNIT-II
ARFLU INDUSTRIAL VALVES Date/ Page No: : 19-07-2024 Page:1 of 1
STO No : 9300003037 Date: 23.05.2024 Magnetizing Current : HWDC

Arflu P.O No. : PC20240397-PV20240054 REV 1 Magnetic Powder : Magnaflux-9C RED Batch No: 23F1043 Mfd-JUN-23

Material : ASTM A216 [Link] Water Conditioner : Magnaflux-WA2B Batch No: 23C35 Mfd-MAY-23

Procedure Reference : ASTM E709 / DIN EN1369 De-Magnetisation : NA


: ASME B16.34 APP-II / AD2000
Acceptance Standard Prod Space (Inches) : 4 - 6''
Table-1
Stage of Test : After heat treatment Current (Ampere) : 450 - 500 Amps

Surface Condition : Pre-Machined stage / After SR Method of Testing : Wet Prod Non-fluorescent
: All Exterior &v Accessible Interior
Extent of Examination Magnetization Field : Circular
Surfaces
Equipment : Magnaflux-P2000 Back Ground Contrast : Grey
Amperage/ Amp
Equipment Calibration Date : 04-03-2024 : NA
Turns Used
Equipment Calibration Due Date : 03-09-2024 Inspection Qty : 01 No
: LX-101A & LUTRON [Link]-
Light Meter Accepted Qty : 01 No
Q872466
Light Intesity : 1100 To 1300 lx Rejected Qty :-

Equipment Calibration Date : 22-03-2024 Date of Test : 19-07-2024

Equipment Calibration Due Date : 21-09-2024

S. No. Item Description Drawing & Rev No. / Part No Heat No MPI No Result

1 20''-150 BODY DP-013434 Rev.1 33225 MP6159T Acceptable

Remark : No Recordable Indications


For LRT Foundry Division Inspected For LRT Foundry Division Approved
Customer
By By

Name: [Link] Name: [Link] Name:

Date: 19-07-2024 Date: 19-07-2024 Date :

Signature : Signature : Signature :

SNT-TC-1A SNT-TC-1A

NDT Level-II MPIDP NDT Level-II MPIDPRTVT