中国港湾(新加坡)工程有限公司

China Harbour (Singapore) Engineering Company Pte Ltd 135T


(ISO 9001:2015, ISO 14001:2015, ISO 45001:2018) Co. Reg No.: 198600104W

Title: Form Identification: TKR-LP-001

Lifting Operation Permit Form Effective Date: 20/3/2024

Lifting Operation Permit Consist of Form A and B) Form B of Lifting Operation Permit Number :

A. Project : 27 Tanjong Kling

B. Date Lifting Plan Submitted : 18/02/2025 Lifting Permit No.:

C. Type of Lift : Routine

1 Parameters of Load

1.1 Load to be lifted : SHEET PILE


1.2 Dimension of Load (LxBxD in meter) : 25M*.6M*.2M

1.3 Centre of gravity : Estimate

1.4 Weight of Load : 3 ton

1.5 Load established by : Supplier OK

2 Particulars of Lifting Machine

2.1 Type of Crane : Crawler Crane Check 2.2 for Out-riggers Extension

2.2 Crane Serial Number GN03-02302

2.3 Out-riggers : N.A. Safe to lift

2.4 Crane Foundation : Steel Plates OK. Keep Sa:RC Ground Slab

2.5 Max Crane SWL : 12 m(R) 41 ton

2.6 Min Crane SWL : 40 m(R) 8 ton

2.7 LM Number : LM092582N LM Issue Date : 09/11/2024 Valid LM Cert

2.8 Data Logger : Yes OK

2 Actual Lifting Radius

2.1 Pick Up Radius, Rp : 20 m 21.9 ton (SWL)

2.2 Install / Unload Radius, Ru : 20 m 21.9 ton (SWL)

2.3 Load Chart Attached : Yes OK

3 Crane Utilisation

3.1 Total Weight of LGs : 0.1 ton

3.2 Weight of Hook Block : 1.2 ton

3.3 Weight of LG & Load : 4.3 ton

20%
Safe to proceed - to obtain PD's approval if crane utilization
3.4 Load versus Crane SWL at Rp :
20% exceeds 85%
Safe to proceed - to obtain PD's approval if crane utilization
3.5 Load versus Crane SWL at Ru :
exceeds 85%
4 Lifting Gears / Accessories Used

4.1 Description of Lifting Gear (1) W LG No. : LGD0104G43 G.R.Shackle


SWL of Lifting Gear : 7.5 ton LG Issue Date: 01/04/2024

Total no. of legs : 1 pcs SWL(per pc) 7.5 ton

4.2 Description of Lifting Gear (2) W LG No. : LGY 2712H50 SHACKE

SWL of Lifting Gear : 8.5 ton LG Issue Date: 27/12/24

Total no. of legs : 1 pcs SWL(per pc) 8.5 ton

4.3 Description of Lifting Gear (3) W LG No. : LGY0601J50-2 8M

SWL of Lifting Gear : 10 ton LG Issue Date: 06/01/2025

Total no. of legs : 1 pcs SWL(per pc) 10 ton

4.4 Description of Lifting Gear (4) W LG No. :

SWL of Lifting Gear : ton LG Issue Date:

Total no. of legs : pcs SWL(per pc) #DIV/0! ton

4.5 Description of Lifting Gear (5) W LG No. :

SWL of Lifting Gear : ton LG Issue Date:

Total no. of legs : pcs SWL(per pc) #DIV/0! ton

4.6 Description of Lifting Gear (6) W LG No. :

SWL of Lifting Gear : ton LG Issue Date:

Total no. of legs : pcs SWL(per pc) #DIV/0! ton

Weakest LG/LA SWL(per pc) : 7.5

5 Lifting Angle / Correction Factor

5.1 No of legs : 1 SWL(per pc) 7.5 ton

5.2 Sling length, Ls : 6 m

5.3 Lifting Point Space, L : 0.1 m

5.4 Lifting Angle, β : 0.76


5.5 Sling Angle, α 89.62 OK >45deg

5.6 Correction Factor : 0.995


5.7 Actual SWL (Ton) 7.46 Total SWL (Ton) 7.46 Safe to lift

Note: Image for illustration & reference purpose only

6 Others

6.1 Strength of unloading area : Others Ensure strength of receiving end

6.2 Obstruction along lifting path : No OK

6.3 Mode of Communication : Walkie Talkie


6.4 Rigging method (To provide sketch) (Reference to Section 3 for details of LG and Accessories)

SHEET PILE

6.5
Conclusion for Lifting Capacity Calucation Check

6.6 Can the lifting operation be carried out? : Yes. Ensure compliance of this plan at site

6.7 a
Prepared By (Lifting Supervisor / Eng): SAHIN Signature:

Designation: LIFTING SUPERVISOR Date: 18/02/2025

7.2b
Checked By(Subcon Competent Person): PARVAG Signature:

Designation: WSHC Date: 18/02/2025

7.2c
Reviewed By (CHEC Safety Assessor): FARUK Signature:

Designation: WSHC Date: 18/02/2025

Comments from CHEC EHS Team (If any):

Comments from CHEC Project Manager / Project Director (If any):