Plan Showing the proposed Construction of Ground Floor Galvalume Sheet Roofed Commercial Building in [Link].
134/2A1B,
Patta No.1994, Plot No.34, "Royal City" Layout at Zamin Uthukuli Village & Town Panchayat, Pollachi Taluk,
Coimbatore District. (k.t.e.C.,.vz;.70/2008)
Applicant Name: [Link] W/[Link]
Ridge Ventilator
Galvalume Sheet
Steel Truss
PLOT NO.25 N
10.67M [35'-0"]
8.67M [28'-5"]
1.00 1.00
6.53 6.53
6.99
Brick work in C.M. 1:6
R.C.C. Lintel [Link] mix
Scale
8.79M [28'-10"]
Floor finish
Flooring concrete [Link] mix
Plan : 1: 100 N
Earth filling Site Plan : 1: 100
0.61
0.46 GL GL R.R. masonry 1:7 mix
0.46
0.46
P.C.C. [Link] Area details [Link]. Sq.m.
FRONT ELEVATION
0.46
SECTION ON A-A' Area of the site 2100.00 195.09
0.61
8.67 0.76 Area of the G.F Building 1372.50 127.51
16.79M [55'-1"]
0.91
PROPOSED GROUND FLOOR
PLOT NO.22 & 35
0.23 1.82 0.12 6.27 0.23
Area of the Open Space 727.50 67.58
PLOT NO.33
18.29M [60'-0"]
18.29M [60'-0"]
1.50M [4'-11"] BUILDING
Rwh
W
0.23
Area Ground Floor Total Area
Toilet 1.22
V
6'-0" x 6'-0" [Link] 1372.50 1372.50
5.00M [16'-5"]
D1 Sq.m 127.51 127.51
1.22
W
Schedule of Joineries
Rain Water Perculation Pit RS Rolling Shutter 8'-0" x 7'-0" (2.44 x 2.13)
8.33
(Not to Scale)Air Holes 2.00M [6'-7"]
Covering Slab D1 Door 2'-6" x 7'-0" (0.76 x 2.13)
3.00M [9'-10"]
Inlet
W Window 4'-0" x 4'-0" (1.22 x 1.22)
45 mm Hard
(0.61 x 0.91)
4'0"
Godown
1.22
27'-0" x 53'-7"
W Blue Granite Metal V Ventilator 2'-0" x 3'-0"
1.00
5.17M [16'-11"]
A A'
3'0"
Site boundary
16.56 0.23 SECTION C-C'
1.50 1.50 Prop. Building
(Not to Scale)
10.67M [35'-0"] Road
C C'
<<< 23'0" WIDE EAST - WEST ROAD >>> Rain Water Pit (Rwh)
1.22
W
1.22
W
4.77 PLAN Parking Details Nos Size (m)
SITE PLAN Car Parking (CP) 1 5.0 X 2.5
Two Wheeler Parking (TWP) 1 1.8 X 1.0
7.01
0.23 [Link] W/[Link]
1.22
W
1.22
W
2.77
2.4400
2.44
0.23 RS
PROPOSED GROUND FLOOR PLAN
Applicant.
SEPTIC TANK WITH DISPERSION TRENCH ( 250 Gls.,)
SECTION ON - AB
A.C. Ventilating Shaft
R.C.C Slab, 100 mm Thick
8'-0"
Inspection Chamber Ventilating hole 1'-0" 6'-0" 1'-0" 4'-0"
Manhole with air tight cover
Formation Level GL
4'-10"
GL GL 2'-0"
A B
2'-0"
Country roofing pantiles extra
U trap large to cover side space
2'-9"
6" S.W. Inlet pipe 150 tk. Outlet Pipe
S.W. Pipe open jointing Dispersion Trench
and laid to fall 1/100
Septic Tank
Dwarf wall 115 tk. Dwarf wall 115 tk.
Brick Work in C.M 1:6
4.5" 4.5"
300 tk. Soil encrasing all sides
1'-0"
Signature Not 1'-0" 11" 6'-0" 11" 1'-0"
P.C.C. [Link]
Verified 7'-10" PLAN
Signed9'-6"
by: Executive Officer
Location:Coimbatore
Date:2025.05.12 [Link]
Registered Engineer
SHEET _1