0% found this document useful (0 votes)
84 views1 page

Rica All Drawings-Air Release-Offline

The document outlines specifications for air valve chambers, including materials, dimensions, and compliance with various standards such as IS EN 124 and IS EN 1074. It details the construction requirements for air valve chambers, including the use of ductile iron covers and concrete materials, as well as installation guidelines for valves and thrust blocks. Additionally, it emphasizes the importance of ensuring the location of air valves minimizes contamination risks and adheres to road reinstatement guidelines.

Uploaded by

manzi gratien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views1 page

Rica All Drawings-Air Release-Offline

The document outlines specifications for air valve chambers, including materials, dimensions, and compliance with various standards such as IS EN 124 and IS EN 1074. It details the construction requirements for air valve chambers, including the use of ductile iron covers and concrete materials, as well as installation guidelines for valves and thrust blocks. Additionally, it emphasizes the importance of ensuring the location of air valves minimizes contamination risks and adheres to road reinstatement guidelines.

Uploaded by

manzi gratien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1. ALL DIMENSIONS IN MILLIMETRES (mm) UNLESS NOTED OTHERWISE.

2. AIR VALVE CHAMBERS SHALL BE COVERED WITH APPROVED VENTILATED HEAVY DUTY DUCTILE IRON COVERS TO IS EN 124 RATING
DIAMETER OF MAIN UP TO 250 (mm) 250 TO 350 (mm) D400. COVER AND FRAME SHALL BE SUITABLE FOR ROAD AND TRAFFIC CONDITIONS AND IS SUBJECT TO REVIEW BY WASAC.
3. AIR VALVES SHALL COMPLY WITH THE REQUIREMENTS OF IS EN 1074-4. AIR VALVES SHALL BE DOUBLE ORIFICE TYPE AND SHALL INCLUDE
AN ISOLATING VALVE. THE ISOLATING VALVE SHALL BE EITHER A GATE VALVE CONFORMING TO IS EN 1074-2 & SHALL BE OF A BOLTLESS
DIAMETER OF BRANCH 80mm 100mm BONNET DESIGN, OR A BUTTERFLY VALVE TO IS EN 1074-2.

5. AIR VALVE CHAMBERS TO BE OF IN-SITU CASTED CONCRETE UNITS OR HIGH DENSITY BLOCKWORK. ALTERNATIVE CONCRTE
BORE OF VALVE INLET 80mm 100mm
HOLLW BRICKS CHAMBER UNITS MAY ALSO BE USED.
6. IN-SITU CASTED CONCRETE CHAMBERS SHALL BE SURROUNDED BY A MINIMUM OF 150mm COMPACTED MATERIAL AS PER
200 600 200 STD-W-13.
7. DUCTILE IRON PIPES / FITTINGS AND HDPE PIPES / FITTINGS TO BE IN ACCORDANCE WITH IS EN 545 AND IS EN 12201:2011.
200 8. 200mm ALL AROUND, 100mm DEEP CONCRETE PLINTH AROUND COVERS IN GREEN AREAS.
9. THRUST BLOCKS (NOT SHOWN ON DRAWING), TO BE PROVIDED AS PER STANDARD DRAWING RICA WSS-CD-13 AT ALL TEES, BENDS, TAPERS,
DEAD ENDS AND PIPES AT STEEP SLOPES.
10. ANTI CORROSION TAPE TO BE PROVIDED AROUND BURIED FLANGES.
11. THE LOCATION OF THE AIR VALVE SHALL BE THE SUBJECT OF PARTICULAR AGREEMENT WITH WASAC TO ENSURE THAT THE RISK
OF CONTAMINATION THROUGH THE VALVE IS ELIMINATED.
BULL NOSE 12. ALL CONCRETE TO BE IN ACCORDANCE WITH IS EN 206.
FINISH 13. ANY SPECIAL ROAD REINSTATEMENT AROUND COVER & FRAME SHALL BE TO RTDA'S REQUIREMENTS.
RICA-AV
600

15. EXISTING ROAD REINSTATEMENT TO COMPLY WITH GUIDELINES FOR MANAGING OPENINGS IN PUBLIC ROADS BY RTDA
200

PLINTH DETAIL IN SEE NOTES 13,15


FINISHED GROUND LEVEL GRASS AREA
MAXIMUM

COVER TO BE SET IN CEMENTITIOUS

MAXIMUM
COVER TO BE SET IN CEMENTITIOUS
250

REFER TO NOTE 2 ON RICA WSS-CD-4


EPOXY RESIN/POLYESTER MORTAR EPOXY RESIN/POLYESTER MORTAR

250
30N/mm2 1 TO 2 COURSES OF CLASS B 30N/mm2
SOLID ENGINEERING BRICK
IN-SITU CASTED CONCRETE UNIT SET IN M30 MORTAR
(REFER TO NOTE 6.) 215mm THICK 20N/mm² CONCRETE
TO IS EN 998
BLOCKWORK IN ACCORDANCE
WITH IS EN 771-3
DOUBLE AIR VALVE
900 MIN.
DOUBLE AIR VALVE

ISOLATING VALVE ISOLATING VALVE


D.I. RISER PIPE TO SUIT D.I. RISER PIPE TO SUIT
DEPTH OF COVER TO MAIN & DEPTH OF COVER TO MAIN &
TO ENABLE ROTATION OF TO ENABLE ROTATION OF
100

100

HANDLE (90° DOWNWARDS) HANDLE (90° DOWNWARDS)


WITH ENOUGH CLEARANCE WITH ENOUGH CLEARANCE
LOCALLY

LOCALLY
TO CONCRETE BEARING SLAB TO CONCRETE BEARING SLAB
MIN.

MIN.
REFER TO RICA WSS-CD-4
150

150
(RISER CAN BE PE FITTING). (RISER CAN BE PE FITTING).
FOR BEDDING AND
C25 / 30 PRECAST BACKFILLING DETAILS C25 / 30 PRECAST
CONCRETE BEARING CONCRETE BEARING
SLAB SLAB
HDPE PIPE HDPE PIPE

FUSION WELD FUSION WELD FUSION WELD FUSION WELD


FUSION WELD HDPE TEE FUSION WELD POLYETHYLENE TEE
SECTION WITH FLANGED BRANCH SECTION WITH FLANGED BRANCH
1030
800
600 600

RICA-AV 75mm HIGH


RICA-AV 75mm HIGH
1030
800

600

600

LETTERING LETTERING

HEAVY DUTY DUCTILE IRON


COVER AND FRAME, STAMPED
''RICA-AV'' CLASS D400 (ALL CLASS
D400 COVERS TO HAVE A FRAME
DEPTH OF 150 - 100mm AND OPE
SIZE TO BE 600mm x 600mm)
ROOF PLAN ROOF PLAN

900 50 215 600 215 50


50

50 100 100 50
600
50

215

215mm THICK 20N/mm² CONCRETE


100

IN-SITU CASTED CONCRETE


BLOCKWORK IN ACCORDANCE
UNITS
108
105

WITH IS EN 771-3
180

180

(REFER TO NOTE 6.)

67 67 67
900

600

600

67

DOUBLE DOUBLE
AIR VALVE AIR VALVE
180

180
100

215

SECTION
50

FLOOR PLAN
DOUBLE AIR VALVE
50

FLOOR PLAN
DOUBLE AIR VALVE
(IN-SITU CASTED CONCRETE
(BLOCKWORK CONSTRUCTION)
CONSTRUCTION)

SCALE: 1:50 DATE


RICA WSS-CONSTRUCTION DRAWING DETAILS MAY-2025

TITLE DRAWING No. REV


IN-LINE AIR VALVE RICA WSS-CD-5

(Sheet 1 of 2)
No. Date Drn Chk Description App

You might also like